Search PubMed⌕ Search

Biomedical subjects

D R Staskin

Publications and source records attributed to D R Staskin.

At least 19 recordsLinked to original sources

Prospective randomized controlled trial of extended-release oxybutynin chloride and tolterodine tartrate in the treatment of overactive bladder: results of the OBJECT Study.

OBJECTIVE: To compare the efficacy and tolerability of extended-release oxybutynin chloride and tolterodine tartrate at 12 weeks in participants with overactive bladder. SUBJECTS AND METHODS: The OBJECT (Overactive Bladder: Judging Effective Control and Treatment) study was a prospective, randomized, double-blind, parallel-group study conducted between March and October 2000 at 37 US study sites. Participants who had between 7 and 50 episodes of urge incontinence per week and 10 or more voids in 24 hours received extended-release oxybutynin, 10 mg/d, or tolterodine, 2 mg twice daily. The outcome measures were the number of episodes of urge incontinence, total incontinence, and micturition frequency at 12 weeks adjusted for baseline. RESULTS: A total of 315 women and 63 men were randomized and treated, and 332 participants (276 women, 56 men) completed the study. At the end of the study, extended-release oxybutynin was significantly more effective than tolterodine in each of the main outcome measures: weekly urge incontinence (P=.03), total incontinence (P=.02), and micturition frequency episodes (P=.02) adjusted for baseline. Both drugs improved symptoms of overactive bladder significantly from baseline to the end of the study as assessed by the 3 main outcome measures (P<.001). Dry mouth, the most common adverse event, was reported by 28.1% and 33.2% of participants taking extended-release oxybutynin and tolterodine, respectively (P=.32). Rates of central nervous system and other adverse events were low and similar in both groups. CONCLUSIONS: Extended-release oxybutynin was more effective than tolterodine as measured by end-of-study urge incontinence, total incontinence, and micturition frequency episodes. Both groups had similar rates of dry mouth and other adverse events.

Aged↗

Hydronephrosis and renal deterioration in the elderly due to abnormalities of the lower urinary tract and ureterovesical junction.

The geriatric population presents a unique challenge to the health care provider. The incidence of common lower urinary tract disorders, such as benign prostatic hypertrophy (BPH), prostate cancer and incontinence increase dramatically with aging. In their more severe forms, these disorders may predispose to hydronephrosis and ultimately to renal deterioration. This review of lower urinary tract and ureterovesical junction (UVJ) physiology and pathophysiology, will focus on: (1) anatomic UVJ obstruction from prostate cancer, or severe bladder hypertrophy, (2) functional obstruction from compression or stretching of the UVJ during bladder distention from urinary retention, and (3) bladder decompensation in the female. We will present a diagnostic and treatment algorithm and discuss future trends in the geriatric population. Clearly, the geriatric health care provider always must consider the lower urinary tract when confronted with acute renal deterioration, because prompt diagnosis and treatment of significant, lower-urinary-tract disease can maximize recovery of renal function.

Age Factors↗

Gore-Tex patch sling: 7 years later.

OBJECTIVES: To assess the long-term results of a transvaginal endoscopic Gore-Tex patch sling in women with genuine stress urinary incontinence due to urethral hypermobility and/or intrinsic sphincter deficiency, with or without coexistent urge incontinence. METHODS: Between December 1989 and June 1994, we performed a Gore-Tex patch sling procedure in 141 consecutive women. All patients had documented stress urinary incontinence on preoperative videourodynamic testing. We conducted outcomes analysis using the information from postoperative office visits, detailed chart reviews, patient questionnaires, and telephone surveys. RESULTS: A complete follow-up was available in 90 patients. The mean follow-up was 51 months (range 27 to 84). Their mean age was 54.2 years (range 32 to 86). Stress incontinence was completely cured in 80 (88.9%) of 90 patients. Pure stress incontinence persisted in 4 (4.4%) of 90 patients. Mixed incontinence occurred in 6 (6.7%) of 90 patients. Pure urge incontinence was experienced by 16 (17.8%) of 90 patients. Six patients required incision of the Gore-Tex patch for obstruction or retention; 3 remain continent. Five patients developed vaginal granulation tissue requiring Gore-Tex patch removal; 1 remains continent. There was no bladder or urethral erosion. CONCLUSIONS: The transvaginal Gore-Tex patch sling has provided durable efficacy with minimal morbidity for the treatment of stress urinary incontinence due to anatomic urethral hypermobility and/or intrinsic sphincter deficiency.

Adult↗

A provocative maneuver to elicit cystometric instability: measuring instability at maximum infusion.

PURPOSE: We identify a provocative maneuver to enhance the sensitivity of cystometry in detecting detrusor instability when urge incontinence is suspected based on clinical history. MATERIALS AND METHODS: A total of 134 consecutive women with clinical urge incontinence underwent carbon dioxide cystometry between August 1995 and October 1996. The bladder was filled to maximal capacity with the patient supine. Six provocative maneuvers were performed consecutively to evoke detrusor instability, including lying supine, rising to a seated position, walking toward the bathroom, handwashing, coughing and sitting on the toilet with instructions not to void. Subjects were divided into 2 groups depending on the order of maneuvers. Sitting on the toilet was the last maneuver for group 1 (80 patients) and was in the middle of the sequence for group 2 (54). RESULTS: Sitting on the toilet evoked detrusor instability in 37.5% of group 1 and 53.8% of group 2. This maneuver with instructions not to void was the most provocative stimulus in eliciting detrusor instability with a detection rate of 68.4% for all subjects. CONCLUSIONS: Sitting on the toilet with the bladder at maximal capacity is the most provocative maneuver for detecting detrusor instability. The incidence of suspected detrusor instability is enhanced by using this test during routine cystometry.

Female↗

Cues to action: pelvic floor muscle exercise compliance in women with stress urinary incontinence.

Pelvic floor muscle exercises are recommended as an initial treatment to women with stress urinary incontinence. This treatment is often unsuccessful because of patient noncompliance. A post-test, experimental control group design was used to examine Pender's (1992) concept of an external cue to action, an audiocassette tape, to enhance patient compliance to pelvic floor exercises. Eighty-six women with urodynamically evaluated stress urinary incontinence participated through a Pelvic Floor Exercise Unit at a large teaching hospital. Patients received biofeedback training and written information to reinforce pelvic floor muscle exercises during a 45-min appointment with a nurse. Patients were instructed to perform the exercises for 10 min twice daily. Forty-three women randomly assigned to an experimental group received an audiocassette tape. Four to 6 weeks later all patients completed a researcher-developed questionnaire that was validity and reliability tested assessing pelvic floor exercise compliance. The 43 patients (100%) who received the audiocassette tape reported compliance with "routine" exercises. Twenty-two of 34 patients (65%) who did not receive the tape were compliant (P = 0.0003). Thirty-four of 41 patients (83%) who received the tape reported exercise compliance twice a day, while 4 of 34 patients (12%) in the control group were similarly compliant (P = 0.0000). The findings suggest adding an audiocassette tape to a pelvic floor exercise program enhances patient compliance for incontinent women compared to verbal and written instruction combined with biofeedback.

Adult↗

The Gore-tex sling procedure for female sphincteric incontinence: indications, technique, and results.

We constructed a pubovaginal sling using the Gore-tex Soft Tissue Patch and 2-0 polytetrafluoroethylene (PTFE) suspension suture and placed it in 122 consecutive incontinent women with urethral hypermobility and/or intrinsic sphincter deficiency. We performed a retrospective outcome analysis using a questionnaire-based telephone survey. The mean follow-up period was 24.4 months. Stress incontinence was cured in 88% of patients (equally effective in type II and type III incontinence), de novo postoperative urinary frequency occurred in 32% of cases, and preoperative urinary frequency resolved postoperatively in 51% of patients. Significant urinary obstruction occurred in 5% of patients. Vaginal granulation tissue with exposed sling occurred in 4% of patients. There was no urethral or bladder erosion. The treatment of female stress incontinence with a PTFE sling is effective and durable with minimal complications. Furthermore, this technique addresses many of the presumed technical shortcomings of endoscopic needle suspensions.

Female↗

Clinical usefulness of urinary control urethral insert devices.

Urinary control urethral insert devices have been introduced as a non-surgical remedy to treat female urinary incontinence. Several early clinical trials have demonstrated the degrees of safety and efficacy, and have defined the morbidity and complications of these urethral inserts. This is a descriptive review of urethral insert devices in clinical use or currently undergoing clinical investigation.

Female↗

Pelvic floor electrical stimulation for the treatment of urge and mixed urinary incontinence in women.

OBJECTIVES: To determine the efficacy of daily or every-other-day electrical stimulation in treating detrusor instability (urge) or urge plus genuine stress (mixed) urinary incontinence in women. METHODS: A multicenter, prospective, nonrandomized study enrolled subjects with urge and mixed urinary incontinence assigned to daily or every-other-day treatments (15 minutes twice daily) using pelvic floor stimulation. Outcome measures assessed were (1) leakage episodes, nocturnal episodes, voiding frequency, total voids, and pad count, and (2) patient subjective assessment and quality of life. RESULTS: Seventy-two subjects were enrolled. Sixty-eight subjects completed the 20-week protocol: 33 treated daily and 35 treated every other day. The entire study group (n = 68) experienced a significant decrease in total leaks (P < 0.001), nocturnal episodes (P = 0.001), pad count (P = 0.002), and total voids (P = 0.003) and on visual analog scales. Sixty-nine percent (n = 46) of subjects with urge or mixed incontinence were cured or improved by at least 50%, with 28% (n = 19) being cured. There were no significant differences between daily and every-other-day users. Nonresponse was correlated with number of previous therapies (P < 0.001) and number of vaginal deliveries (P = 0.007). Overall, subjects were 93% compliant with device use, and 72% (n = 47) were satisfied with the therapy. CONCLUSIONS: Twenty weeks of pelvic floor electrical stimulation therapy is effective in treating urge and mixed urinary incontinence, regardless of daily or every-other-day treatments.

Adult↗

Patient satisfaction with a reusable undergarment for urinary incontinence.

PURPOSE: We investigated patient satisfaction with a reusable undergarment for urinary incontinence. SUBJECTS AND SETTING: One hundred seventy-five participants with reported urinary incontinence from two urology-based clinics at large teaching hospitals and one prostate cancer support group participated in the study. METHODOLOGY: Each participant was given a minimum of one reusable undergarment for urinary incontinence. Participants used the undergarment for an average of 10 days (range 1 to 60 days). During the trial period, subjects alternated the reusable undergarment with their previous urine-containment devices, usually disposable pads, while the undergarment was being washed. Patient satisfaction was evaluated with a questionnaire. PRIMARY OUTCOME MEASURES: Patient satisfaction with the reusable undergarment was measured for six categories: (1) physical comfort, (2) ability to keep skin dry, (3) ability to prevent wet spots, (4) discretion, (5) odor control, and (6) confidence when wearing the garment versus previously used containment devices. RESULTS: Of the 175 subjects, 126 (33% female and 67% male) completed and returned the 7-page questionnaire. All respondents reported at least one urinary incontinent episode while wearing the reusable undergarment. Occurrence and degree of leakage by self-report varied from light leakage (33%) to moderate leakage (48%) and heavy leakage (17%). Patient satisfaction was measured as follows: (1) 83% rated the overall comfort of the undergarment as very good or excellent; (2) 52% said they felt very dry or dry when wearing the product after an incontinent episodes; (3) 75% rated the ability to prevent wet spots on outer clothing as adequate or excellent; (4) 75% rated the discretion of this product as excellent; (5) 80% rated the ability to control odor as adequate or excellent; and (6) 67% felt more confidence with this reusable undergarment than with other products with which they were familiar. CONCLUSION: The reusable garment provided effective containment from urine loss among this group of incontinent women and men.

Adult↗

Artificial urinary sphincter: evolution and development.

The first hydraulic artificial urinary sphincter came into clinical use in 1972. The original prototype has undergone many modifications resulting from advances in mechanical design, applications of new technology, and clinical experience. This evolutionary process has culminated in the AS800, the most frequently used hydraulic artificial urinary sphincter in the U.S. today. Although the AS800 device most closely approximates the biological urinary sphincter, clinical demands for an ever more ideal urinary sphincter require the ongoing improvement of this device.

Equipment Design↗

Urinary incontinence: steps to evaluation, diagnosis, and treatment.

In this era of rapid, scientific medical advances, we still live with the myth that urinary incontinence should be accepted as a normal part of aging. Urinary incontinence, however, should not be considered a disease but rather a symptom or sign of an underlying problem. Patients with urinary incontinence now have many places to turn for advice and medical treatment. In addition to urologists, gynecologists, and geriatricians, nurses are actively involved in the evaluation and management of patients with urinary incontinence. The purpose of this article is to outline a systematic nursing approach to the evaluation, diagnosis, and treatment of patients with urinary incontinence in an office setting.

Adult↗

Pelvic floor electrical stimulation: a comparison of daily and every-other-day therapy for genuine stress incontinence.

OBJECTIVES: To compare the effectiveness of daily and every-other-day electrical stimulation in treating genuine stress incontinence. METHODS: Subjects with genuine stress incontinence were enrolled in a multicenter, prospective, nonrandomized study and underwent daily or every-other-day pelvic floor stimulation treatments for 15 minutes twice a day. Outcome measures assessed were (1) leakage episodes and pad count; (2) leakage amount, and (3) subject subjective assessment and quality of life. Thirteen subjects treated daily and 15 treated every other day completed the 20-week protocol. One-year follow-up data were available for 21 subjects. RESULTS: No significant differences in primary outcome variables were found between the groups. Subjects treated every other day had significant decreases in total leakage episodes (P = 0.04), pad count (P = 0.04), total voids (P = 0.02), and visual analog scale scores, with stress incontinence cured or improved by 50% in 73% (n = 11). Subjects treated every day had significant decreases in urge episodes (P = 0.03), pad count (P = 0.05), and visual analog scale scores, with 62% (n = 8) cured or improved by 50%. Compliance was higher for subjects treated every other day (P = 0.05). Satisfaction with therapy was 75% (n = 10) for daily treatment and 77% (n = 12) for every-other-day treatment. At 1 year, 70% (n = 7) of subjects who continued device use maintained their cure or improvement status. CONCLUSIONS: Both daily and every-other-day therapy with pelvic floor electrical stimulation are effective in treating genuine stress incontinence. Subjects who continue device use maintain a higher curve or improvement rate.

Electric Stimulation↗

History, physical examination, and classification of neurogenic voiding dysfunction.

Although exceptions exist, clinical and urodynamic findings can be predicted on the basis of the location of the neurologic lesions. Conversely, these findings can be used to predict the location of the lesion. Recognition of similar patterns allows for classification, and classification allows the physician more readily to devise a diagnostic and therapeutic plan. Furthermore, a simple and practical classification system facilitates communication between physicians.

Central Nervous System↗

Use of synthetic material in sling surgery: a minimally invasive approach.

Traditionally, autologous material has been favored over synthetic material in the construction of pubovaginal slings for the treatment of female stress urinary incontinence (SUI). This preference arose largely because of concern about an increased incidence of infection or sling erosion when synthetic materials are used. However, when care is taken to minimize the amount of synthetic material, reduce total operative time, and limit exposure of the material to the operative field, female SUI can be treated effectively with synthetic material with an acceptably low complication rate. Furthermore, utilization of slings constructed with artificial graft material can be minimally invasive, cost effective, and well tolerated.

Biocompatible Materials↗

Pelvic floor electrical stimulation in the treatment of genuine stress incontinence: a multicenter, placebo-controlled trial.

OBJECTIVE: Our purpose was to determine the efficacy of transvaginal electrical stimulation in treating genuine stress incontinence. STUDY DESIGN: This was a multicenter, prospective, randomized, double-blind, placebo-controlled 15-week trial comparing the use of an active pelvic floor stimulator with a sham device. Thirty-five women used an active unit and 17 control subjects used sham devices. Weekly and daily voiding diaries were recorded throughout the trial. Urodynamic testing, including pad test and subtracted cystometry, was done before and at the end of device use. Pelvic muscle strength was measured at baseline and at the end of the trial. Patients scored their symptoms on visual analog scales and completed quality-of-life questionnaires before and after therapy. RESULTS: Significant improvements from baseline were found in patients using active devices but not in controls. Comparisons of changes from baseline between active-device and control patients showed that active-device patients had significantly greater improvement in weekly (p = 0.009) and daily (p = 0.04) leakage episodes, pad testing (p = 0.005), and vaginal muscle strength (p = 0.02) when compared with control subjects. Significantly greater improvement was also found for both visual analog scores of urinary incontinence (p = 0.007) and stress incontinence (p = 0.02), as well as for subjective reporting of frequency of urine loss (p = 0.002), and urine loss with sneezing, coughing, or laughing (p = 0.02), when compared with controls. Pad testing showed that stress incontinence was improved by at least 50% in 62% of patients using an active device compared with only 19% of patients using sham devices (p = 0.01). Voiding diaries showed at least 50% improvement in 48% of active-device patients compared with 13% of women using the sham device (p = 0.02). No irreversible adverse effects were noted in either group. CONCLUSIONS: Transvaginal pelvic floor electrical stimulation was found to be a safe and effective therapy for genuine stress incontinence.

Double-Blind Method↗

Intraperitoneal bladder rupture after normal vaginal delivery.

To our knowledge we report the first case of bladder perforation in a patient with no history of pelvic surgery or delivery. The patient presented 3 days post partum with renal failure and ascites. Paracentesis and cystography confirmed urinary ascites and bladder rupture. After open bladder repair convalescence was uneventful. The literature on intraperitoneal bladder rupture and urinary ascites is reviewed.

Adult↗

Experience with the penile prosthesis and artificial urinary sphincter.

The therapy of two common urologic problems, erectile dysfunction and urinary stress incontinence, has been revolutionized over the last 20 years by the incorporation of principles of hydraulic mechanics into the field of silicone prosthesis implantation. The inflatable penile prosthesis is surgically implanted into men with impotence due to organic or psychogenic etiology. The artificial urinary sphincter has found widespread use in males and females in both the adult and pediatric populations with stress incontinence from a variety of causes. Associated with these popular devices are various complications relating to the anatomic site as well as the host's immunologic response. The use of these implants, as well as the technologic innovations resulting from various adverse effects, are reviewed herein.

Erectile Dysfunction↗

Abnormal detrusor function precipitating hydronephrosis identified by extended voiding cystometry.

Extended voiding cystometry was performed to elucidate the true detrusor function in a patient originally misdiagnosed during standard fill cystometry. This methodology allows for observation of an extended period of bladder activity and eliminates the artifacts of classical fill cystometry, which are detrusor instability and noncompliance. A chronically elevated intravesical pressure between contractions (inter-contraction pressure) representing high pressure residual urine, as well as frequent, high amplitude, long duration detrusor contractions during the storage phase and a large post-void residual urine volume were documented. These urodynamic abnormalities are known to precipitate hydroureteronephrosis in the absence of vesicoureteral reflux.

Adult↗