Search PubMed⌕ Search

Biomedical subjects

D R Stanski

Publications and source records attributed to D R Stanski.

At least 19 recordsLinked to original sources

Pharmacodynamics of orally administered sustained- release hydromorphone in humans.

BACKGROUND: The disposition kinetics of hydromorphone generally necessitates oral administration every 4 h of the conventional immediate-release tablet to provide sustained pain relief. This trial examined time course and magnitude of analgesia to experimental pain after administration of sustained-release hydromorphone as compared with that after immediate-release hydromorphone or placebo. METHODS: Using a 4 x 4 Latin square double-blind design, 12 subjects were randomized to receive a single dose of 8, 16, and 32 mg sustained-release hydromorphone and placebo. The same subjects had received 8 mg immediate-release hydromorphone before this study. Using an electrical experimental pain paradigm, analgesic effects were assessed for up to 30 h after administration, and venous hydromorphone plasma concentrations were measured at corresponding times. RESULTS: The hydromorphone plasma concentration peaked significantly later (12.0 h [12.0--18.0] vs. 0.8 h [0.8--1.0]; median and interquartile range) but was maintained significantly longer at greater than 50% of peak concentration (22.7 +/- 8.2 h vs. 1.1 +/- 0.7 h; mean +/- SD) after sustained-release than after immediate-release hydromorphone. Similarly, sustained-release hydromorphone produced analgesic effects that peaked significantly later (9.0 h [9.0--12.0] vs. 1.5 h [1.0--2.0]) but were maintained significantly longer at greater than 50% of peak analgesic effect (13.3 +/- 6.3 h vs. 3.6 +/- 1.7 h). A statistically significant linear relation between the hydromorphone plasma concentration and the analgesic effect on painful stimuli existed. CONCLUSION: A single oral dose of a new sustained-release formulation of hydromorphone provided analgesia to experimental pain beyond 24 h of its administration.

Administration, Oral↗

Lumbar epidural morphine in humans and supraspinal analgesia to experimental heat pain.

BACKGROUND: Epidural administration of morphine is a common analgesic technique to manage pain. Morphine spreads from the epidural space to the cerebrospinal fluid and then rostrally, causing side effects mediated by the brain stem. However, data on the rostral spread of morphine-mediated analgesia are sparse. This study examined the rostral spread of analgesic effects on heat and electrical pain after epidural administration of morphine. METHODS: In a randomized, double-blinded, placebo-controlled, crossover study, 5 mg morphine or saline placebo were injected into the lumbar epidural space in nine healthy volunteers. Correct needle placement was confirmed with fluoroscopy. Analgesia to experimental nociceptive heat and electrical stimuli was measured at lumbar (L4), thoracic (T10), cervical (C2), and trigeminal (V2) levels before and 2, 5, 10, and 24 h after epidural injection. Plasma samples for assaying morphine concentrations were drawn before and after each analgesic evaluation. RESULTS: Epidural morphine significantly attenuated experimental heat pain at all dermatomes tested compared with saline placebo. Analgesic effects were significant at L4 after 2, 5, and 10 h, at T10 after 5, 10, and 24 h, and at V2 after 10 h. Electrical pain was attenuated at the lumbar and thoracic but not at the cervical dermatome. Analgesic effects were significant at L4 after 2, 5, and 10 h and at T10 after 5 and 10 h. Morphine plasma concentrations were below the detection limit (1 ng/ml) in eight of the nine subjects 10 h after epidural injection. CONCLUSIONS: Lumbar epidural injection of morphine attenuated cutaneous heat pain up to the trigeminal dermatome during a 24-h observation period. In a clinical context, this implies that some types of pain may be attenuated up to the supraspinal level after lumbar epidural administration of morphine.

Adult↗

Application of physiologic models to predict the influence of changes in body composition and blood flows on the pharmacokinetics of fentanyl and alfentanil in patients.

BACKGROUND: The influence of changes in the physiologic state of a patient on the disposition of fentanyl and alfentanil is poorly understood. The aims of this study were to determine whether physiologic pharmacokinetic models for fentanyl and alfentanil, based on data from rats, could predict plasma concentrations of these opioids in humans and to determine how changes in physiology would influence the predictions of their disposition. METHODS: The predictions of the models were tested against plasma concentration data from published pharmacokinetic studies. The influences of changes in body composition, cardiac output, and regional blood flows on the disposition of the opioids were simulated. RESULTS: The models could predict independently measured plasma concentrations of the opioids after short infusions in humans. Simulations then predicted that differences in body composition between men and women would have little influence on the pharmacokinetics of the opioids. Changes in cardiac output would affect drug redistribution, and consequently the early decay of the plasma concentrations, but not markedly influence rates of elimination. Further, the clearance of the opioids would decrease and their volumes of distribution increase with the age of the patient, but this would only marginally affect the early disposition of the drugs. Even large fluctuations in peripheral or hepatic blood flows would have modest effects on arterial plasma concentrations of the opioids, and sudden "postoperative" increases in peripheral blood flows would cause minor secondary plasma concentration peaks. CONCLUSIONS: The ability of the physiologic models to predict plasma concentrations of fentanyl and alfentanil in humans was confirmed. When changes in physiologic condition were simulated, effects on the pharmacokinetics of the opioids with possible implications for dosing were obtained only if cardiac output was varied over a wide range.

Adult↗

A comparison of spectral edge, delta power, and bispectral index as EEG measures of alfentanil, propofol, and midazolam drug effect.

BACKGROUND: The effects of anesthetic drugs on electroencephalograms (EEG) have been studied to develop the EEG as a measure of anesthetic depth. Bispectral analysis is a new quantitative technique that measures the consistency of the phase and power relationships and returns a single measure, the bispectral index. The purpose of this study was to compare the performance of the bispectral index, version 1.1, with other spectral analysis EEG measures of drug effect for three commonly used anesthetic drugs. METHODS: The EEG waveforms from 31 adults receiving infusions of alfentanil, propofol, or midazolam were analyzed. The time course of spectral edge (SE95), relative power in delta band, and bispectral index were related to the estimated effect-site concentration with use of a sigmoidal Emax model to estimate the potency (IC50) and the plasma effect-site equilibration rate constant (Ke0) for each measure. The performance of the fitting was assessed by the coefficient of correlation between predicted and observed effect. RESULTS: Alfentanil induced a high-amplitude low-frequency EEG response. Propofol induced a biphasic response. At low concentrations, both frequency and amplitude increased. When the concentration increased, the EEG slowed and the amplitude decreased. High concentration produced burst suppression. Midazolam increased EEG frequency and amplitude. Bispectral index, SE95, and delta power yield similar estimates of IC50 and ke0. Except for alfentanil, the performance of the modeling with the bispectral index was as good that with SE95 or delta power. CONCLUSION: Bispectral analysis can be used as a measure of the EEG effects of anesthetic drugs.

Adult↗

Computer simulation of the effects of alterations in blood flows and body composition on thiopental pharmacokinetics in humans.

BACKGROUND: Understanding the influence of physiological variables on thiopental pharmacokinetics would enhance the scientific basis for the clinical usage of this anesthetic. METHODS: A physiological pharmacokinetic model for thiopental previously developed in rats was scaled to humans by substituting human values for tissue blood flows, tissue masses, and elimination clearance in place of respective rat values. The model was validated with published serum concentration data from 64 subjects. The model was simulated after intravenous thiopental administration, 250 mg, over 1 min, to predict arterial plasma concentrations under conditions of different cardiac outputs, degrees of obesity, gender, or age. RESULTS: The human pharmacokinetic model is characterized by a steady state volume of distribution of 2.2 l/kg, an elimination clearance of 0.22 l/min, and a terminal half-life of 9 h. Measured thiopental concentrations are predicted with an accuracy of 6 +/- 37% (SD). Greater peak arterial concentrations are predicted in subjects with a low versus a high cardiac output (3.1 and 9.4 l/min), and in subjects who are lean versus obese (56 and 135 kg). Acutely, obesity influences concentrations because it affects cardiac output. Prolonged changes are due to differences in fat mass. Changes with gender and age are relatively minor. CONCLUSIONS: The physiological pharmacokinetic model developed in rats predicts thiopental pharmacokinetics in humans. Differences in basal cardiac output may explain much of the variability in early thiopental disposition between subjects.

Adult↗

Pharmacokinetic-pharmacodynamic characterization of the cardiovascular, hypnotic, EEG and ventilatory responses to dexmedetomidine in the rat.

This study characterizes the pharmacokinetic-pharmacodynamic (PK-PD) relationships of the cardiovascular, EEG, hypnotic and ventilatory effects of the alpha-2 adrenergic agonist dexmedetomidine in rats. Dexmedetomidine was administered by a single rapid infusion (n = 6) and by an infusion regimen of gradually increasing rate (n = 8). HR, mean arterial pressure (MAP) and EEG signals were recorded continuously, as was the time at which the rats woke up spontaneously from drug-induced sleep, a measure of hypnosis. Arterial concentrations of dexmedetomidine and blood gases were determined regularly. A sigmoidal Emax model was used to describe the HR, MAP and EEG concentration-effect relationships, with the EEG effect (activity in 0.5-3.5-Hz frequency band) linked to an effect-site model. The PK of dexmedetomidine could be described by a two-compartment model, with similar PK parameters for both infusion regimens. Plasma protein binding was 84.1[0.7]%. Because of complex cardiovascular homeostatic reflex mechanisms, HR and MAP could only be analyzed during gradually increasing infusions. The maximal decrease in HR was 35(2)%, and the maximal increase in MAP was 37(2)%. For both infusion regimens, similar PD parameters were found for the EEG and the hypnotic measure. These data suggest the absence of active metabolites or tolerance of the EEG and hypnotic effects. Judging on the basis of concentrations of dexmedetomidine (mean (S.E. M.)), HR decrease was the most sensitive response [EC50 of 0.65(0. 09) ng/ml], followed by increase in MAP [EC50 of 2.01(0.14) ng/ml], change in EEG activity [EC50 of 2.24(0.16) ng/ml] and the hypnotic measure [Cwake-up of 2.64(0.10) ng/ml]. Ventilatory effects were minor.

Adrenergic alpha-Agonists↗

High-performance liquid chromatographic assay of propofol in human and rat plasma and fourteen rat tissues using electrochemical detection.

This paper describes a sensitive HPLC-electrochemical detection analytical method for determining the concentration of the intravenous anesthetic, propofol, in human or rat plasma or serum and a variety of rat tissues. Internal standard and drug are extracted from serum or plasma and other tissues with pentane. 2,6-tert.-Butylmethylphenol is used as internal standard. It includes a novel steam distillation procedure for separating the highly lipophilic propofol from skin and fat. The plasma/serum assay has a precision of 1-4% (C.V.) in the range 10 ng/ml to 1 microgram/ml and permits the assay of assay of 5 ng/ml from 0.1 ml of plasma/serum. The tissue procedure allows the estimation of 50 ng/g in 0.1 g of tissue for most of the major organs with less than 2% (C.V.) precision. This assay was used to measure propofol concentrations in plasma/serum and tissue samples in support of a project to develop a physiological pharmacokinetic model for propofol in the rat.

Animals↗

Comparative absorption kinetics of intramuscular midazolam and diazepam.

PURPOSE: This study investigates the rate and extent of absorption following intramuscular injection of midazolam and diazepam. METHODS: Four healthy male volunteers were recruited in this randomized three-way cross-over study. On one occasion each subject received simultaneous im injections of 5 mg midazolam and 10 mg diazepam in separate deltoid muscles. On two other separate occasions each subject received an iv infusion of 7.5 mg midazolam and 30 mg diazepam over five minutes. Frequent arterial blood samples were collected for up to two hours and venous blood samples were collected for up to 24 hours for midazolam and ten days for diazepam. A gas chromatography assay was used to determine the plasma concentrations of midazolam and diazepam. The im absorption profiles were estimated using constrained least-squares deconvolution. RESULTS: There were substantial intersubject variabilities in the estimated pharmacokinetic parameters (volume and clearances) of intravenous midazolam and diazepam. The mean (+/-sd) time to peak plasma concentration (Cmax) was shorter for im midazolam (17.5 +/- 6.5 min) relative to diazepam (33.8 +/- 7.5 min). The mean (+sd) time to peak absorption rate was also shorter for midazolam (9 +/- 2 vs 13.8 +/- 7.5 min). The peak rate of absorption was identical (0.18 mg. min-1) and bioavailability was 1.0 for both drugs. CONCLUSIONS: We conclude that midazolam has more rapid absorption than diazepam following im administration.

Absorption↗

Population pharmacodynamic model for ketorolac analgesia.

OBJECTIVE: To derive a population pharmacokinetic-pharmacodynamic model that characterizes the distribution of pain relief scores and remedication times observed in patients receiving intramuscular ketorolac for the treatment of moderate to severe postoperative pain. BACKGROUND: The data analysis approach deals with the complexities of analyzing analgesic trial data: (1) repeated measurements, (2) ordered categorical response variables, and (3) nonrandom censoring because the patients can take a rescue medication if their pain relief is insufficient. METHODS: Patients (n = 522) received a single oral or intramuscular administration of placebo or a single intramuscular dose of 10, 30, 60, or 90 mg ketorolac for postoperative pain relief. Pain relief was measured periodically with use of a five-category ordinal scale up to 6 hours after dosing. In this period, 288 patients received additional medication because of insufficient pain relief. Pharmacokinetic data was available for 85 subjects. Models were fitted to the data with the NONMEM program. RESULTS: The pharmacokinetic data was best described by a two-compartment model with first-order absorption. Pain relief was found to be a function of drug concentration (Emax model), time (waxing and waning of placebo effect), and an individual random effect. The drug concentration at half-maximal effect (EC50) and the first-order rate constant (keo) half-life for pain relief were 0.37 mg/L and 24 minutes. The probability of remedication was found to be a function of the observed level of pain relief and was found to increase with time. Monte Carlo simulations showed that adequate pain relief was achieved in 50% of the patients at 41, 27, 23, and 21 minutes after 10, 30, 60, or 90 mg of intramuscular ketorolac. Adequate pain relief was maintained up to 6 hours in 50%, 70%, 78%, and 81% of patients after these four doses. Only 25% of the patients achieved adequate pain relief with placebo. CONCLUSIONS: A population pharmacokinetic-pharmacodynamic model for the analgesic efficacy of intramuscular ketorolac was derived. The simulated relationship between dose, time, and percentage of patients with adequate pain relief suggested that 30 mg intramuscular ketorolac was the optimal initial dose for postoperative pain relief.

Administration, Oral↗

Characterization and validation of a pharmacokinetic model for controlled-release oxycodone.

1. Oxycodone is a strong opioid agonist that is currently available in immediate-release (IR) formulations for the treatment of moderate to severe pain. Recently, controlled-release (CR) oxycodone tablets were developed to provide the benefits of twice-a-day dosing to patients treated with oxycodone. The purpose of this investigation was to develop and validate a pharmacokinetic model for CR oxycodone tablets in comparison with IR oxycodone solution. 2. Twenty-four normal male volunteers were enrolled in a single-dose, randomized, analytically blinded, two-way crossover study designed to compare the pharmacokinetics of two 10 mg CR oxycodone tablets with 20 mg IR oxycodone oral solution. Pharmacokinetic models describing the oxycodone plasma concentration vs time profiles of CR tablets and IR solution were derived using NONMEM version IV. The predictive performance of the models was assessed by comparison of predicted oxycodone plasma concentrations with actual oxycodone plasma concentrations observed in a separate group of 21 volunteers who received repeated doses of IR and CR oxycodone for 4 days. 3. The unit impulse disposition function of oxycodone was best described by a one-compartment model. Absorption rate of the IR solution was best described by a mono-exponential model with a lag time, whereas absorption rate of the CR tablet was best described using a bi-exponential model. The absorption profile of the CR tablets was characterized by a rapid absorption component (t1/2abs = 37 min) accounting for 38% of the available dose and a slow absorption phase (t1/2abs = 6.2 h) accounting for 62% of the available dose. Two 10 mg tablets of oral CR oxycodone hydrochloride were 102.7% bioavailable relative to 20 mg of IR oxycodone hydrochloride oral solution. The population model derived after administration of a single dose accurately predicted both the mean and range of oxycodone concentrations observed during 4 days of repeated dosing. The mean prediction error was 2.7% with a coefficient of variation of 54%. 4. The absorption characteristics of CR oxycodone tablets should allow effective plasma concentrations of oxycodone to be reached quickly and for effective concentrations to be maintained for a longer period after dosing compared with the IR oral solution. The CR dosage form has pharmacokinetic characteristics that permit 12 hourly dosing.

Adult↗

Quantitation of depth of thiopental anesthesia in the rat.

BACKGROUND: In contrast to that of inhalational anesthetics, quantitation of anesthetic depth for intravenous agents has not been well defined. In this study, using rodents, the relationship between the constant plasma thiopental concentrations and the clinical response to multiple nociceptive stimuli were investigated characterizing the anesthetic state from light sedation to deep anesthesia and correlated to the degree of electroencephalogram (EEG) drug effect. METHODS: Thirty rats were instrumented with chronically implanted EEG electrodes, arterial and venous catheters. A computer-driven infusion pump was used to rapidly attain and then maintain constant, target plasma thiopental concentrations ranging from 7 to 100 micrograms/ml. Three different target plasma thiopental concentrations were achieved in each rat. Electroencephalographic effects were monitored with aperiodic waveform analysis. The following nociceptive stimuli were applied: (1) unprovoked righting reflex, (2) provoked righting reflex, (3) noise stimulus, (4) tail clamping with an alligator clip, (5) constant tail pressure with an analgesiameter, (6) corneal reflex, and (7) tracheal intubation. For tail clamping, tail pressure, and intubation, either purposeful extremity movement or abdominal muscle contraction response was noted to be present or absent. The clinical responses (present or absent) were modeled using logistic regression to estimate the Cp50, the plasma thiopental concentration with a 50% probability of no response. RESULTS: The following mean Cp50 values (95% confidence interval) were obtained: unprovoked righting reflex, 15.9 (15.1-16.6) micrograms/ml; provoked righting reflex, 21.4 (20.2-22.7) micrograms/ml; noise stimuli, 31.3 (29.7-33.0) micrograms/ml; tail clamp and limb movement, 38.3 (36.1-40.4) micrograms/ml; tail pressure and limb movement, 39.2 (37.1-41.3) micrograms/ml; tail pressure and abdominal muscle contraction, 52.5 (50.0- 55) micrograms/ml; tail clamping and abdominal muscle contraction, 56.1 (50.0-56.2) micrograms/ml; corneal reflex, 60.0 (56.6-63.4) micrograms/ml; and limb movement or muscle abdominal contraction response to intubation, 67.7 (59.2-76.1) micrograms/ml. At an EEG-effect of 9.1 and 2.2 waves/s, there was a 50% chance of limb movement response to tail clamping and tracheal intubation, respectively. There was a poor relationship between the plasma thiopental concentration and the percent increase of either heart rate or mean arterial blood pressure after applying either tail pressure or tail clamp stimuli. CONCLUSIONS: A range of nociceptive stimuli and their observed clinical responses can be used to quantitate thiopental anesthetic depth, ranging from light sedation to deep anesthesia (isoelectric EEG and unresponsive to intubation) in the rodent. Clinical response can be mapped to surrogate EEG measures.

Anesthesia, Inhalation↗

Effects of thiopental on regional blood flows in the rat.

BACKGROUND: The goal of this investigation was to characterize the effects of thiopental on cardia output and regional blood flows in the rat. Blood flows influence thiopental pharmacokinetics. Acquisition of these data may ultimately permit evaluation of the contribution of thiopental-induced alterations in regional blood flows to the disposition and hypnotic effect of this drug. METHODS: Chronically instrumented unrestrained Wistar rats (n=20) aged 3-4 months received either a dose of thiopental sufficient to induce a brief period of unconsciousness (20 mg.kg(-1)) or a larger dose achieving electroencephalographic burst suppression (45 mg.kg(-1)). Cardiac output and blood flows to 14 tissues were determined at 4 times in each rat for a period of 420 min using injections of radioactive microspheres (expressed as mean +/- SD). Mean arterial pressure, heart rate, and blood gas tensions were determined at all measurement times. Arterial plasma concentrations were sampled at postinfusion times. RESULTS: No important changes in systemic cardiovascular measurements were detected after the smaller dose of thiopental. One minute after the larger dose, cardiac output decreased from baseline (123 +/- 14 to 84 +/- ml.min (-1), P< 0.01), flow to muscle and fat decreased, and muscle and fat resistance increased. At 5 min, compared to baseline, no difference in cardiac output was detected (123 +/- vs. 119 +/- ml.min (-1)), intestinal flows increased and intestinal resistances decreased. Cardiac output was again depressed at 30, 90, and 180 min. Brain blood flow decreased 25 +/- 19 % (P< 0.01) from baseline for the duration of the study. CONCLUSIONS: Thiopental acutely decreases cardiac output, and blood flows to muscle and fat tissue. The temporary return of cardiac output to baseline may be related to intestinal vasodilation. These blood flow alterations may influence the pharmacokinetics of thiopental.

Anesthetics, Intravenous↗

Thiopental uncouples hippocampal and cortical synchronized electroencephalographic activity.

BACKGROUND: Thiopental produces a concentration-dependent continuum of effects on the cortical electroencephalogram (EEG) that has been linked to behavioral measures of anesthetic depth. The complexity of the response, however, limits a clear insight into the neurophysiologic actions of thiopental. The current study investigated thiopental actions on cortical EEG and hippocampal electrical activity, to determine whether similar effects occur on both structures and to compare synchronized activity between these structures. METHODS: Thiopental was administered intravenously via an implanted catheter in freely moving rats. Arterial blood oxygen/carbon dioxide concentration, thiopental concentrations, and temperature were monitored and controlled. Neocortical EEG was recorded from implanted dural surface electrodes and hippocampal neuron electrical activity was recorded from stereotaxically placed microelectrodes. Pharmacokinetic models were used to determine effect site concentrations. RESULTS: Thiopental produced an increase in EEG frequency and amplitude at low concentrations (15-20 micrograms/ml total plasma, approximately 10 microM unbound), which produced a loss of righting reflex. This was followed by a frequency decrease and burst suppression activity at higher concentrations (50-80 micrograms/ml, approximately 60 microM), which produced a loss of tail pinch and corneal reflexes. Higher concentrations of thiopental ( > 60 micrograms/ml) uncoupled synchronized burst discharges recorded in hippocampus and cortex. Isoelectric EEG activity was associated with concentrations of 70-90 micrograms/ml (approximately 80 microM) and a deep level of anesthesia; motor reflexes were abolished, although cardiovascular reflexes remained. In all frequency bands, similar concentration-EEG effect relationships were observed for cortical and hippocampal signals, only differing in the magnitude of response. A reversed progression of effects was observed on recovery. CONCLUSIONS: The results confirm earlier findings in humans and animals and demonstrate that both the hippocampus and neocortex exhibit burst suppression and isoelectric activity during thiopental anesthesia. Thiopental-induced synchronized burst activity was depressed by progressively higher concentrations. The lost synchronization suggests a depression of synaptic coupling between cortical structures contributes to anesthesia.

Anesthetics, Intravenous↗

Pharmacodynamic modeling of the electroencephalographic effects of flumazenil in healthy volunteers sedated with midazolam.

The purpose of this study was to model pharmacodynamically the reversal of midazolam sedation with flumazenil. Ten human volunteers underwent four different sessions. In session 1, individual midazolam pharmacokinetics and electroencephalographic pharmacodynamics were determined. In sessions 2 and 3, a computer-controlled infusion of midazolam with individual volunteer pharmacokinetic data was administered, targeting a plasma concentration corresponding to a light or deep level of sedation (20% or 80% of the maximal midazolam electroencephalographic effect) for a period of 210 minutes. After obtaining a stable electroencephalographic effect and constant midazolam plasma concentrations, a zero-order infusion of flumazenil was started until complete reversal of midazolam electroencephalographic effect was obtained. The flumazenil infusion was then stopped and the volunteer was allowed to resedate because of the constant midazolam drug effect. The electroencephalographic response was measured during a 180-minute period and analyzed by aperiodic analysis and fast-Fourier transforms. In session 4, a midazolam plasma concentration corresponding to a deep level of sedation was targeted for 210 minutes to examine for the possible development of acute tolerance. No flumazenil was given in session 4. For a light sedation level, with a mean midazolam plasma concentration of 160 +/- 64 ng/ml, the mean half-life of the equilibration rate constant of flumazenil reversal is 5.0 +/- 2.5 minutes, and the mean effect site concentration causing 50% of Emax is 13.7 +/- 5.8 ng/ml. For a deep level of sedation, with a mean midazolam plasma concentration of 551 +/- 196 ng/ml, the mean half-life of the equilibration rate constant is 3.9 +/- 1.5 minutes, and the mean effect site concentration causing 50% of Emax is 20.6 +/- 6.8 ng/ml. This study provides an estimate of the magnitude of the blood/central nervous system equilibration delay for flumazenil antagonism of midazolam sedation and further defines the usefulness of the electroencephalogram as a measure of midazolam pharmacodynamic effect.

Adult↗

A PC-based graphical simulator for physiological pharmacokinetic models.

Since many intravenous anesthetic drugs alter blood flows, physiologically-based pharmacokinetic models describing drug disposition may be time-varying. Using the commercially available programming software MATLAB, a platform to simulate time-varying physiological pharmacokinetic models was developed. The platform is based upon a library of pharmacokinetic blocks which mimic physiological structure. The blocks can be linked together flexibly to form models for different drugs. Because of MATLAB's additional numerical capabilities (e.g. non-linear optimization), the platform provides a complete graphical microcomputer-based tool for physiologic pharmacokinetic modeling.

Anesthetics↗

Pharmacokinetic/dynamic assessment in drug development: application to the investigational opioid mirfentanil.

The safety, pharmacokinetics, and pharmacodynamics of the investigational partial opioid agonist, mirfentanil, were determined in a dose-escalating, Phase 1 study in healthy male volunteers. Hemodynamic, central nervous system, and respiratory monitoring were used for safety assessment. The electroencephalogram (EEG) was evaluated as a surrogate measure of drug effect. Butorphanol was chosen as the control drug. In the mirfentanil group (n = 8) the dose was increased in sequential subjects from 25 micrograms.kg-1.min-1 for 30 min to 450 micrograms.kg-1.min-1 for 15 min, and in the butorphanol group (n = 10) from 2 micrograms.kg-1.min-1 for 30 min to 25 micrograms.kg-1.min-1 for 15 min. In the mirfentanil group, serious side effects were observed at plasma concentrations more than 2000 ng/mL: heart rates exceeded 130 bpm (n = 2), epileptiform EEG potentials (n = 2), and a convulsion (n = 1). The clearance of mirfentanil was high (5.8-7.2 L/min), and the volume of distribution large (247-348 L). The EEG of the subjects receiving mirfentanil showed no changes typical for opioids. Butorphanol however, caused intermittent slowing in the delta and theta ranges. The results of our study define the upper limit of safe plasma concentrations in future mirfentanil studies.

Adult↗