Optical fiber design and the trapping of Cerenkov radiation.

Cerenkov radiation is generated in optical fibers immersed in radiation fields and can interfere with signal transmission. We develop a theory for predicting the intensity of Cerenkov radiation generated within the core of a multimode optical fiber by using a ray optic approach and use it to make predictions of the intensity of radiation transmitted down the fiber in propagating modes. The intensity transmitted down the fiber is found to be dominated by bound rays with a contribution from tunneling rays. It is confirmed that for relativistic particles the intensity of the radiation that is transmitted along the fiber is a function of the angle between the particle beam and the fiber axis. The angle of peak intensity is found to be a function of the fiber refractive index difference as well as the core refractive index, with larger refractive index differences shifting the peak significantly toward lower angles. The angular range of the distribution is also significantly increased in both directions by increasing the fiber refractive index difference. The intensity of the radiation is found to be proportional to the cube of the fiber core radius in addition to its dependence on refractive index difference. As the particle energy is reduced into the nonrelativistic range the entire distribution is shifted toward lower angles. Recommendations on minimizing the quantity of Cerenkov light transmitted in the fiber optic system in a radiation field are given.

Journal Article↗

A plastic scintillation dosimeter for high dose rate brachytherapy.

In vivo dose verification in brachytherapy requires a small insertable dosimeter with a real-time readout capability. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are one of the most promising dosimeters for this application. We have developed two sizes of the BrachyFOD scintillation dosimeter which have external diameters of 2.2 mm and 1 mm and have determined their important dosimetric characteristics (depth dose relation, angular dependence, temperature dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries using an (192)Ir source from an HDR brachytherapy unit. The dosimeter design enables readout at less than 0.5 s intervals. The BrachyFOD satisfies the need for a real-time in vivo brachytherapy dosimeter.

Brachytherapy↗

Intrafractional motion during proton beam scanning.

Patient and internal organ motion during treatment with a scanned proton beam can introduce unplanned heterogeneities in the dose distribution throughout the irradiated volume. With static beam techniques, a margin around the target volume is added to compensate for patient and organ motion. This margin may not provide the solution with dynamic beam scanning. Intrafractional motion parallel and perpendicular to the beam axis is studied using two different scanning methods on a cubic water phantom. The direction of motion relative to the beam scanning direction as well as the method of scanning the proton beam across the target has a significant effect on the resulting dose distribution within the target volume. In the extreme cases studied here up to 100% of the target receives a dose outside the recommended limits, with a minimum dose as low as 34% of the prescribed dose.

Algorithms↗

Real-time verification of HDR brachytherapy source location: implementation of detector redundancy.

Independent treatment verification for high dose rate (HDR) brachytherapy is needed to ensure that the treatment proceeds as prescribed. In this paper, we investigate the feasibility of a proposed real-time source position verification process. This process provides immediate confirmation of the source position during the treatment, so that the treatment can be aborted and modified if necessary. We show that an array of dosimeters placed on the patient's skin can independently verify the position in three dimensions. This verification was demonstrated by using a diamond detector placed in several locations on the surface of an anthropomorphic phantom. A mathematical algorithm was constructed to estimate the location of the source given a measured data set in the presence of tissue heterogeneity. The accuracy of the source localization was found to increase with the number of detectors used to compute the estimation of the source position. The resolution to which the 12 detectors can identify the location of the source was within 3 mm.

Algorithms↗

Phosphine dissociation on the Si(001) surface.

Density functional calculations are performed to identify features observed in STM experiments after phosphine (PH3) dosing of the Si(001) surface. On the basis of a comprehensive survey of possible structures, energetics, and simulated STM images, three prominent STM features are assigned to structures containing surface bound PH2, PH, and P, respectively. Collectively, the assigned features outline for the first time a detailed mechanism of PH3 dissociation and P incorporation on Si(001).

Journal Article↗

Apparatus for exposing cell membranes to rapid temperature transients.

We seek to determine whether cell membranes contain sensors that trigger a downstream response to temperature excursions. To do this, we have developed a novel apparatus for exposing a cell membrane to an extremely rapid temperature excursion in the nanosecond range. Cells are plated on a gold surface that is back-heated by a pulsed laser and cooled by conduction of heat into the glass substrate and the liquid medium. Analysis using the heat diffusion equation shows that the greatest temperature rise is localized within a region tens of nanometres thick, suitable for specifically heating a cell membrane without heating the remainder of a cell. We refer to this device as a nanosecond hotplate.

Cell Culture Techniques↗

High dose-rate brachytherapy source localization: positional resolution using a diamond detector.

A potential real-time source position verification process for high dose-rate (HDR) brachytherapy treatment is described. This process is intended to provide immediate confirmation that a treatment is proceeding according to plan, so that corrective action can be taken if necessary. We show that three dosimeters are in principle sufficient and demonstrate the feasibility of the process using a diamond detector and an Ir-192 source. An error analysis including all identified sources of error shows that this detector is capable of locating the distance to the source to within 2 mm for distances up to 12 cm. This positional accuracy is less than the diameter of typical HDR catheters indicating that a diamond detector can be used to accurately determine the distance to the source. The uncertainty in the distance is found to increase with distance.

Algorithms↗

Electron tomography and computer visualisation of a three-dimensional 'photonic' crystal in a butterfly wing-scale.

A combination of transmission electron tomography and computer modelling has been used to determine the three-dimensional structure of the photonic crystals found in the wing-scales of the Kaiser-I-Hind butterfly (Teinopalpus imperialis). These scales presented challenges for electron microscopy because the periodicity of the structure was comparable to the thickness of a section and because of the complex connectivity of the object. The structure obtained has been confirmed by taking slices of the three-dimensional computer model constructed from the tomography and comparing these with transmission electron microscope (TEM) images of microtomed sections of the actual scale. The crystal was found to have chiral tetrahedral repeating units packed in a triclinic lattice.

Animals↗

An efficient ab initio calculation of powder diffraction intensity using Debye's equation.

The Debye equation gives the spherically averaged diffracted intensity from a group of atoms and is exact under the first Born, or kinematic, approximation. Algebraic simplifications are developed for calculating multiplicities in the double summation and are used in a new algorithm for implementing this equation. The results for cubic, body-centred cubic and face-centred cubic systems agree exactly with previous methods while achieving substantial computational advantage.

Journal Article↗

Photonic engineering. Aphrodite's iridescence.

The most intense colours displayed in nature result from either multilayer reflectors or linear diffraction gratings. Here we investigate the spectacular iridescence of a spine (notoseta) from the sea mouse Aphrodita sp. (Polychaeta: Aphroditidae). The spine normally appears to be deep red in colour, but when light is incident perpendicular to the axis of the spine, different colours are seen as stripes running parallel to the axis of the spine; over a range of smaller incident angles, the complete visible spectrum is reflected with a reflectivity of 100% to the human eye. The simple structure responsible for this effect is a remarkable example of photonic engineering by a living organism.

Animals↗

Mobile phones, heat shock proteins and cancer.

There are several reports which indicate that electromagnetic radiation (such as from mobile phones) at non-thermal levels may elicit a biological effect in target cells or tissues. Whether or not these biological effects lead to adverse health effects, including cancer, is unclear. To date there is limited scientific evidence of health issues, and no mechanism by which mobile phone radiation could influence cancer development. In this paper, we develop a theoretical mechanism by which radiofrequency radiation from mobile phones could induce cancer, via the chronic activation of the heat shock response. Upregulation of heat shock proteins (Hsps) is a normal defence response to a cellular stress. However, chronic expression of Hsps is known to induce or promote oncogenesis, metastasis and/or resistance to anticancer drugs. We propose that repeated exposure to mobile phone radiation acts as a repetitive stress leading to continuous expression of Hsps in exposed cells and tissues, which in turn affects their normal regulation, and cancer results. This hypothesis provides the possibility of a direct association between mobile phone use and cancer, and thus provides an important focus for future experimentation.

Animals↗

Effects of fexofenadine, diphenhydramine, and alcohol on driving performance. A randomized, placebo-controlled trial in the Iowa driving simulator.

BACKGROUND: Sedating antihistamines may impair driving performance as seriously as alcohol. OBJECTIVE: To compare the effects of fexofenadine, diphenhydramine, alcohol, and placebo on driving performance. DESIGN: Randomized, double-blind, double-dummy, four-treatment, four-period crossover trial. SETTING: The Iowa Driving Simulator. PARTICIPANTS: 40 licensed drivers with seasonal allergic rhinitis who were 25 to 44 years of age. INTERVENTION: One dose of fexofenadine (60 mg), diphenhydramine (50 mg), alcohol (approximately 0.1% blood alcohol concentration), or placebo, given at weekly intervals before participants drove for 1 hour in the Iowa Driving Simulator. MEASUREMENTS: The primary end point was coherence, a continuous measure of participants' ability to match the varying speed of a vehicle that they were following. Secondary end points were drowsiness and other driving measures, including lane keeping and response to a vehicle that unexpectedly blocked the lane ahead. RESULTS: Participants had significantly better coherence after taking alcohol or fexofenadine than after taking diphenhydramine. Lane keeping (steering instability and crossing the center line) was impaired after alcohol and diphenhydramine use compared with fexofenadine use. Mean response time to the blocking vehicle was slowest after alcohol use (2.21 seconds) compared with fexofenadine use (1.95 seconds). Self-reported drowsiness did not predict lack of coherence and was weakly associated with minimum following distance, steering instability, and leftlane excursion. CONCLUSIONS: Participants had similar performance when treated with fexofenadine or placebo. After alcohol use, participants performed the primary task well but not the secondary tasks; as a result, overall driving performance was poorer. After participants took diphenhydramine, driving performance was poorest, indicating that diphenhydramine had a greater impact on driving than alcohol did. Drowsiness ratings were not a good predictor of impairment, suggesting that drivers cannot use drowsiness to indicate when they should not drive.

Adult↗

Effect of ion modification of commonly used orthopedic materials on the attachment of human bone-derived cells.

Biomaterials which combine optimum properties of strength and biocompatibility are desirable in improving the long-term performance of implantable medical devices. Our study is aimed at developing technology designed to alter the outer atomic layers of a material to give the desired compatibility with the tissue while retaining the properties of the bulk substratum. Materials used in this study were titanium vanadium alloy (Ti-6Al-4V) and cobalt chromium molybdenum alloy (Co-Cr). Soda lime glass discs and polyethylene terephthalate (PET) acted as controls. A cathode of either Ti-6Al-4V or Co-Cr was used to simultaneously deposit and implant identified substrata. The attachment of human bone-derived cells (HBDC) to various materials was determined using radiolabeling or colorimetric assays. Results show that HBDC adhere preferentially to the unmodified surfaces of Ti-6Al-4V and Ti-6Al-4V on glass compared to the unmodified Co-Cr surfaces and to that of the Co-Cr on glass. Depositing Ti-6Al-4V on Co-Cr gives significantly better attachment of HBDC than when depositing Co-Cr onto Ti-6Al-4V. While cellular attachment to the created surfaces reflects that of the cathodic materials, it is not identical to these materials. Ion deposition/implantation is capable of creating permanent surfaces which reflect the adhesion of source materials not bulk substrata.

Alloys↗

Childhood incidence of acute lymphoblastic leukaemia and exposure to broadcast radiation in Sydney--a second look.

INTRODUCTION: Recent findings of an apparent association between incidence of childhood leukaemia and radio frequency radiation (RFR) from television transmission antennas in Sydney, NSW, are examined. METHODS: Incidence of childhood (0-14 years) acute lymphoblastic leukaemia (ALL) at the local government area (LGA) level is related to estimated exposure levels of RFR from television transmission antennas, using Poisson regression techniques. RESULTS: Most of the association between ALL incidence and television transmission RFR is shown to be the result of an influential observation: one of the highly exposed LGAs contributes all the excess, while in a similarly exposed LGA childhood ALL incidence was found to be no higher than the rate expected for NSW. With the influential observation excluded from the analysis, no positive correlation between exposure to RFR and leukaemia is evident. Conversely, under the assumption of an association with RFR, the low probability of the observed incident cases in LGAs under conditions of relatively high exposure to RFR conflicts with the assumption of an effect. CONCLUSION: The apparent association between childhood ALL incidence and RFR radiation from television towers is weaker when an LGA-level analysis is conducted.

Adolescent↗

Effects of exposure to electromagnetic radiation at 835 MHz on growth, morphology and secretory characteristics of a mast cell analogue, RBL-2H3.

A mast cell line, RBL-2H3, was exposed to 835 MHz for 20 minutes, three times per day for 7 days at a power density of 8.1 +/- 3 mW/cm2. From day 4 onwards, it was observed that the rate of DNA synthesis and cell replication increased, that actin distribution and cell morphology became altered, and the amount of beta-hexosaminidase (a marker of granule secretion) released in response to a calcium ionophore was significantly enhanced, in comparison to unexposed cultures. There were no effects seen on levels of cytoskeletal protein synthesis or of beta-actin mRNA. Morphological changes persisted following subculture for at least 7 days in the absence of further exposure. It is hypothesized that effects of exposure to an electromagnetic field at 835 MHz may be mediated via a signal transduction pathway.

Actins↗

Perinatal factors predicting severe intracranial hemorrhage.

The objective of this paper is to determine the importance of perinatal factors predicting occurrence of severe intracranial hemorrhage (ICH) in premature newborns. A post-hoc analysis of a previously published randomized, double-blinded, prospective trial was performed. Logistic regression analysis was used to assess the importance of obstetrical variables and umbilical cord blood coagulation studies and acid-base status in predicting severe ICH (grades 3 and 4). The trial lasted 42 months; 401 pregnant women were invited to participate and 48 declined. The most important predictors of severe ICH in order of decreasing significance were: gestational age at delivery (p=0.0001), duration of painful labor (p=0.0077), duration of antenatal antibiotic therapy (p=0.0203), maternal age (p=0.0247), and factor X activity in umbilical cord blood (p=0.0302). Mode of delivery, cord blood acid-base, and coagulation status did not correlate with severe ICH. The majority of severe ICHs were late in onset; only two of 31 were known to have occurred in the first 24 hr of life. Gestational age, duration of painful labor, duration of antibiotic therapy, and maternal age were the most important predictors of severe ICH.

Adult↗