Search PubMed⌕ Search

Biomedical subjects

D R Jordan

Publications and source records attributed to D R Jordan.

At least 37 records · Page 2Linked to original sources

Epithelioid hemangioma of the orbit.

OBJECTIVE: To describe the histopathologic features of two cases of epithelioid hemangioma occurring in the orbit and to distinguish this condition from Kimura's disease and from other vascular lesions of proliferated endothelium. DESIGN: Two interventional case reports. INTERVENTION: Treatment consisted of orbitotomy with excision of the tumor. MAIN OUTCOME MEASURES: Histopathologic examination including light microscopy, immunohistochemistry, and electron microscopy and clinical follow-up. RESULTS: In one case, there was no local recurrence after 2 years of follow-up. In the other case, local recurrence required re-excision 2 years after surgery with no apparent recurrence 16 years later. Histopathologic examination of both tumors disclosed an epithelioid hemangioma. A characteristic finding was the presence of peculiar plump vacuolated endothelial cells lining the vascular lumina. CONCLUSIONS: Epithelioid hemangioma is an uncommon benign vascular tumor that can occur in the orbit, and surgical excision is usually required. It is the same condition as angiolymphoid hyperplasia with eosinophilia. There are distinct clinical and histopathologic characteristics to distinguish epithelioid hemangioma from Kimura's disease and from other vascular tumors.

Aged↗

Mucoepidermoid carcinoma of the conjunctiva: a series of three cases.

OBJECTIVE: To detail the clinical presentation and outcomes of currently available treatments for mucoepidermoid carcinoma of the conjunctiva (MCC). DESIGN: Retrospective noncomparative case series. PARTICIPANTS: Three patients ranging from 40 to 63 years of age with MCC participated. INTERVENTION: Excisional biopsies and various therapies were performed. MAIN OUTCOME MEASURES: Clinical and surgical outcomes were measured. RESULTS: Patient 1 is a 55-year-old man with right temporal MCC. He underwent two local excisions with adjuvant cryotherapy and has had no recurrence at 31 months follow-up. Patient 2 is a 63-year-old man with right temporal MCC who underwent fractionated iodine 125 plaque radiotherapy. He had a recurrence approximately 8 months after plaque treatment and subsequently underwent enucleation of the right eye. Clinical follow-up examinations revealed no further recurrence at 17 months. Patient 3 is a 40-year-old woman treated for right MCC with carbon dioxide laser with recurrence at 3 weeks. She subsequently underwent radiation treatment with the development of regional lymph node metastases 16 months later. CONCLUSIONS: MCC is a rare neoplasm that displays an extraordinary capacity for aggressive local invasion. This series of three case reports demonstrates the high recurrence rate of MCC and the response of this tumor to different current modalities of treatment. Extended follow-up is required with this tumor because distant metastases can occur very late.

Adult↗

Hydroxyapatite implant wrapping materials: analysis of fibrovascular ingrowth in an animal model.

PURPOSE: To compare the influence of seven currently available spherical orbital implant wraps on host fibrovascularization of a hydroxyapatite (HA) orbital implant. METHODS: Five groups of 3 (15 total) adult male New Zealand albino rabbits underwent enucleation with placement of a 12-mm HA implant wrapped in high-porosity expanded polytetrafluoroethylene (e-PTFE), processed bovine pericardium, or processed human pericardium, sclera, or fascia lata. Magnetic resonance imaging before and after the intravenous administration of gadolinium-diethylenetriamine pentaacetic acid (DTPA, 0.1 mol/kg) was performed immediately before exenteration. Five rabbits (one with each of the different implant wraps) were killed at 4, 8, and 12 weeks, and the operated socket was exenterated. Histopathologic sections of the implants were then compared with the results of our previous study using polyglactin 910 mesh and autologous sclera as HA orbital implant wraps. RESULTS: Complete fibrovascularization of all the implants occurred by 12 weeks; however, HA implants wrapped with sclera, polyglactin mesh, and e-PTFE appeared to undergo more rapid fibrovascularization than spheres wrapped with other materials. CONCLUSIONS: Although all of the implant wraps studied may be suitable substitutes for donor sclera, we prefer polyglactin mesh because it is readily available, inexpensive, and without risk of transmissible diseases.

Animals↗

The bioceramic orbital implant: a new generation of porous implants.

PURPOSE: The authors describe a new generation of porous orbital implant made of aluminum oxide (Al2O3) and compare it with the hydroxyapatite orbital implants (Bio-Eye and FCI hydroxyapatite). METHODS: The authors examined the new implant macroscopically, with chemical analysis and microscopically with scanning electron microscopy. Animal implantation studies were performed using six adult male New Zealand albino rabbits. Implant vascularization was evaluated by means of magnetic resonance imaging and histopathologic sectioning. RESULTS: The Bioceramic orbital implant was found to have very uniform pore structure with an average pore size of 500 microm. The implant was 99.9% aluminum oxide on x-ray diffraction. Magnetic resonance imaging in vivo vascularization studies demonstrated enhancement of the implant to its center by 4 weeks after implantation in the rabbit. Histopathologically, fibrovascularization occurred uniformly throughout the implant and was noted by 4 weeks. CONCLUSIONS: The Bioceramic orbital implant represents a new porous orbital implant that has a very regular and extensive interconnected pore system, is as biocompatible as hydroxyapatite, is easy to manufacture, structurally strong, and free of contaminants. It is manufactured with no disruption to marine life ecosystems as may occur in the harvesting of coral for other orbital implants. It is less expensive than currently available hydroxyapatite implants and was approved by the U.S. Food and Drug Administration in April 2000.

Aluminum Oxide↗

The Molteno M-Sphere.

PURPOSE: To analyze a mammalian hydroxyapatite (HA) implant known as the Molteno M-Sphere, recently approved by the Food and Drug Administration of the United States. METHODS: The authors examined the implant macroscopically, with chemical analysis (x-ray powder diffraction, x-ray fluorescence spectrophotometry), and microscopically with scanning electron microscopy. Animal implantation of six Molteno M-Spheres was carried out in six adult male New Zealand albino rabbits. Implant vascularization was evaluated by means of magnetic resonance imaging and histopathologic sectioning. RESULTS: The M-Sphere was found to have multiple interconnected pores throughout with an average pore size of 300 microm to 600 microm. This implant was very light-weight (0.31 g) and fragile. It was made up of pure HA. Magnetic resonance imaging studies showed implant enhancement to its center by 4 weeks after implantation. Histopathologically, fibrovascularization occurred uniformly throughout the 4, 8, and 12-week rabbit implants. CONCLUSIONS: The M-Sphere is an alternative type of HA implant that recently has been reintroduced into the United States for use after enucleation, evisceration, or as a secondary implant. It has multiple interconnected pores allowing central fibrovascularization as early as 4 weeks in a rabbit model. Its light weight and fine trabecular framework, however, are associated with increased implant fragility when compared with other available HA implants (BioEye and FCI3 synthetic HA). The implant requires careful handling because routine handling may damage the implant. The implant is currently approved by the United States Food and Drug Administration.

Animals↗

Brazilian hydroxyapatite implant.

PURPOSE: To evaluate a synthetic hydroxyapatite (HA) (manufactured in Brazil) in a rabbit model. METHODS: Nine New Zealand white rabbits underwent enucleation of one eye followed by implantation of either a 12-mm Brazilian synthetic HA implant or a 12-mm BioEye, wrapped in polyglactin 910 mesh. Magnetic resonance imaging was performed to assess fibrovascular ingrowth 4, 8, and 12 weeks after implantation. Three animals were killed at each of the times for histopathologic examination. The Brazilian implant was also examined chemically and by scanning electron microscopy. RESULTS: The Brazilian HA was found to be heavier than either the BioEye or synthetic FCI3 HA implants. It did not have a visible, regularly arranged interconnected porous architecture. Rather, it had randomly appearing channels apparent on its external and internal surface in addition to large cystic areas within the body of the implant. Scanning electron microscopy revealed the implant to have a microporous architecture in addition to the large channels and cystic cavities. Histopathologically, central vascularization occurred by 4 weeks and was also present at 8 and 12 weeks. In three Brazilian implants an unrecognizable, nonbirefringent material was identified. The cause of it was unclear. Chemical analysis confirmed the implant to consist of pure HA. CONCLUSION: The Brazilian implant is pure HA that appears solid but has randomly arranged channels as well as a microporous architecture that allows vascularization to its center. It is heavier than other available HA implants and has the presence of an unidentified foreign material within it. Although this implant is less expensive and does not require a costly manufacturing process, the structural characteristics of the material do not offer any theoretical or clinical advantages. The implant is only available in Brazil at this time.

Animals↗

A new titanium peg system for hydroxyapatite orbital implants.

PURPOSE: To evaluate a new hydroxyapatite-coated titanium sleeve and titanium peg system for HA orbital implants. METHODS: The authors followed 54 patients receiving an HA-coated titanium sleeve and peg system and analyzed the complications associated with this peg system. The following data were recorded: type of surgery performed, size of implant used, type of HA used, time of pegging, follow-up duration, problems encountered, and treatment. RESULTS: Fifty-seven patients received the HA-coated titanium peg and sleeve system. The average duration of follow-up was 15 months (range, 3-30 months). Three patients were lost to follow-up after 1 month. Complications associated with peg placement in 54 patients included: discharge (9.2%), pyogenic granulomas (14.8%), peg falling out during prosthesis removal (9.2%), poor transfer of movement (1.8%), clicking (3.7%), conjunctiva overgrowing peg (1.8%), part of sleeve shaft visible (9.2%), peg drilled on an angle (1.8%), HA visible around peg hole (3.7%), and loose sleeve (3.7%). CONCLUSION: The HA-coated titanium sleeve and titanium peg is a new peg system available for HA orbital implants. Many of the complications associated with this peg system are similar to the commonly used polycarbonate peg system. Pyogenic granulomas and discharge, however, appear to be less frequently encountered with this new system. The HA-coated titanium sleeve and titanium pegs were well tolerated and appeared quieter in the socket than most polycarbonate pegs.

Adult↗

Cerebrospinal fluid leakage during endscopic forehead lifting.

PURPOSE: To report a case of endoscopic brow lift in which cerebrospinal fluid leakage was encountered. METHOD: A 69-year-old otherwise healthy man underwent endoscopic forehead lifting. RESULTS: An area of strong adherence was encountered in the area of the left superior paracentral scalp incision. As the adherence was released, clear fluid extruded (cerebrospinal fluid) and a burr hole was discovered. Absorbable gelatin sponge was placed over the dural defect and burr hole, and closure of the endoscopic scalp incisions was accomplished. CONCLUSION: Caution is suggested in performing this procedure when a patient has any history of a head trauma.

Aged↗

Unilateral proptosis in an immunocompetent man as the initial clinical manifestation of systemic Hodgkin disease.

OBJECTIVE: Orbital involvement in Hodgkin disease (HD) is rare. Previously reported cases of HD in patients without the acquired immunodeficiency syndrome have been diagnosed late in the course of established systemic disease. The authors describe an immunocompetent man with orbital infiltration as the initial manifestation of systemic HD. DESIGN: Case report. PARTICIPANTS: A 47-year-old man with acute progressive, painless proptosis of the left eye is described. INTERVENTION: A well-defined, homogeneous soft tissue mass of the superior left orbit was evident on computed tomography, and an incisional biopsy of the nontender mass was performed. RESULTS: The histopathologic findings were characteristic of HD. Systemic investigations showed clinical stage 3A HD. Ten months after completion of hybrid chemotherapy, the patient remained in complete remission from his HD. CONCLUSION: Hodgkin disease presenting initially in the orbit of a patient with the acquired immunodeficiency syndrome has been described previously. The patient presented in this report is the first case of HD in the recent English literature with the initial manifestation in the orbit of an otherwise immunocompetent patient.

Acute Disease↗

Complications associated with pegging hydroxyapatite orbital implants.

OBJECTIVE: Prior studies of hydroxyapatite orbital implant complications have primarily focused on complications of the implant itself with only occasional mention of the complications associated with the peg system. This in part may be because of a low rate of pegging and, thus, a small sample size to evaluate. Therefore, a full range of complications that can occur with pegging has not been presented. The objective of this study was to determine the complications associated with pegging and to discuss ways to manage them. DESIGN: Retrospective, noncomparative case series. PARTICIPANTS/INTERVENTION: The authors analyzed all of the complications associated with pegging 165 of a possible 275 hydroxyapatite implants implanted by 2 surgeons over 7 years. MAIN OUTCOME MEASURES: The following data were recorded: type of surgery performed, size of implant used, type of hydroxyapatite used, peg system used, time of pegging, follow-up duration, problems encountered, and treatment. RESULTS: Sixty-two (37.5%) of the 165 patients who had pegged implants were found to have problems with their pegs. Twenty-one (33.8%) of the 62 patients with peg problems had more than 1 peg-related problem. Complications associated with pegging included discharge (37%; 23 of 62), pyogenic granulomas (30.6%; 19 of 62), peg falling out (29%; 18 of 62), poor transfer of movement (11.2%; 7 of 62), clicking (11.2%; 7 of 62), conjunctiva overgrowing peg (4.8%; 3 of 62), poor-fitting sleeve (4.8%; 3 of 62), part of sleeve shaft visible (4.8%; 3 of 62), peg drilled on an angle (4.8%; 3 of 62), hydroxyapatite visible around peg hole (3.2%; 2 of 62), peg drilled off-center (3.2%; 2 of 62), popping peg (3.2%; 2 of 62), and excess movement of peg (3.2%; 2 of 62). The most serious complication occurring in two individuals (3.2%) was implant infection requiring implant removal. CONCLUSION: There are several potential complications that can occur after pegging the hydroxyapatite implant. These problems are generally of a minor nature but often require additional patient visits that would not ordinarily have been required if the peg was not in place. The most serious peg problem is implant infection, which may necessitate implant removal. These potential peg problems should be reviewed with the patient before the procedure is performed.

Adolescent↗

Congenital, paradoxical lower eyelid retraction on upgaze.

PURPOSE: Active lower eyelid retraction on upgaze is a rarely described finding. The purpose of this study is to describe the clinical and operative findings in two patients with this unique eyelid movement disorder. METHODS: The authors identified active, unilateral lower eyelid retraction on upgaze in two patients who had no other ocular or systemic abnormalities. RESULTS: Surgical extirpation of the lower eyelid retractor complex was carried out in both cases. During one of the procedures, performed under local anesthesia, the lower eyelid retractors were observed to retract actively on upgaze. Postoperatively, lower eyelid retraction on upgaze was not present in either case. CONCLUSIONS: The authors are aware of only one other case report describing active, paradoxical lower eyelid retraction on upgaze. The mechanism of eyelid retraction in this previous report and in the two patients described herein is not known. The authors postulate that these unique cases may represent a previously unrecognized form of congenital, aberrant innervation of the oculomotor nerve.

Adolescent↗

A new variety of hydroxyapatite: the Chinese implant.

PURPOSE: This study was designed to evaluate a new type of hydroxyapatite (HA) implant (produced in China) in a rabbit model. METHODS: Three New Zealand white rabbits underwent enucleation of one eye followed by implantation of a 12-mm Chinese HA implant wrapped in Vicryl mesh (polyglactin 910). Magnetic resonance imaging was performed to assess host fibrovascularization of the implant 4, 8, and 12 weeks after implantation. One animal was sacrificed at each of these times for histopathologic examination. The Chinese implant was also examined chemically and by scanning electron microscopy. It was compared to the original BioEye and the third generation synthetic HA implant produced in France by FCI (FCI3). RESULTS: This new variety of HA implant from China is heavier than the FCI3 implant but lighter than the original BioEye. The Chinese implant was easy to work with and not fragile. The pore size was more uniform than the FCI3 implant and similar to the BioEye implant clinically and by scanning electron microscopy. The pores in this implant are unidirectional. Analysis for impurities revealed a calcium oxide (CaO) content of 4.4%. Histopathologically, central vascularization occurred by 4 weeks and was similar in extent to the vascularization seen with the FCI3 implant and the BioEye. CONCLUSIONS: The Chinese implant is less expensive then the BioEye and the FCI3 implants, and appears to be a viable alternative to the BioEye. Further refinements are in progress to eliminate the CaO contaminant.

Animals↗

The ocular complications of periocular laser surgery.

Laser periocular surgery has achieved an increased popularity, especially since recent technical developments in the carbon dioxide and erbium:yttrium-aluminum-garnet lasers. Despite the relative safety of these procedures in experienced hands, postoperative complications affecting the periocular region, and the eye itself, may follow laser surgery. Common complications include persistent erythema, hyper- and hypopigmentation, and hypertrophic scarring. Skin infection (viral, bacterial, or fungal) may also jeopardize the postoperative period after periocular laser treatment. Severe burns, transitory or permanent, lower lid ectropion, and even corneal injuries or ocular perforation are among the most severe hazards. A thorough preoperative evaluation, appropriate training, and a cautious and conservative approach are reinforced to minimize such problems.

Eyelid Diseases↗