Search PubMed⌕ Search

Biomedical subjects

D R Hose

Publications and source records attributed to D R Hose.

25 records · Page 2Linked to original sources

The epitheliome: agent-based modelling of the social behaviour of cells.

We have developed a new computational modelling paradigm for predicting the emergent behaviour resulting from the interaction of cells in epithelial tissue. As proof-of-concept, an agent-based model, in which there is a one-to-one correspondence between biological cells and software agents, has been coupled to a simple physical model. Behaviour of the computational model is compared with the growth characteristics of epithelial cells in monolayer culture, using growth media with low and physiological calcium concentrations. Results show a qualitative fit between the growth characteristics produced by the simulation and the in vitro cell models.

Algorithms↗

Development of an ex vivo model to investigate the effects of altered haemodynamics on human bypass grafts.

The insertion of vein grafts into the arterial circulation may contribute to vessel wall thickening and accelerated atherosclerosis, a common feature of late vein graft failure. We aimed to develop a model suitable for investigation of the effects of altered haemodynamics on human saphenous vein following its implantation into the arterial circulation. Segments of human saphenous vein obtained from patients undergoing coronary artery bypass surgery were sutured at each end to PTFE and placed into a flow system. Pressure and flow rates to stimulate the arterial and venous systems were achieved. A theoretical model of the flow chamber was created and computational fluid dynamics software (FLOTRAN, Swanson Analysis Systems) was used to determine the flow profile within the model. In summary, a flow model has been developed to investigate the effect of altered haemodynamics on the molecular and pathological changes that occur in vein grafts incorporated into the arterial circulation.

Blood Flow Velocity↗

Fluid-solid interaction: benchmarking of an external coupling of ANSYS with CFX for cardiovascular applications.

Fluid-solid interaction is a primary feature of cardiovascular flows. There is increasing interest in the numerical solution of these systems as the extensive computational resource required for such studies becomes available. One form of coupling is an external weak coupling of separate solid and fluid mechanics codes. Information about the stress tensor and displacement vector at the wetted boundary is passed between the codes, and an iterative scheme is employed to move towards convergence of these parameters at each time step. This approach has the attraction that separate codes with the most extensive functionality for each of the separate phases can be selected, which might be important in the context of the complex rheology and contact mechanics that often feature in cardiovascular systems. Penrose and Staples describe a weak coupling of CFX for computational fluid mechanics to ANSYS for solid mechanics, based on a simple Jacobi iteration scheme. It is important to validate the coupled numerical solutions. An extensive analytical study of flow in elastic-walled tubes was carried out by Womersley in the late 1950s. This paper describes the performance of the coupling software for the straight elastic-walled tube, and compares the results with Womersley's analytical solutions. It also presents preliminary results demonstrating the application of the coupled software in the context of a stented vessel.

Arteries↗

Measurement of the symmetry of in vitro stent expansion: a stereo-photogrammetric approach.

Balloon-expandable stents are used routinely in the treatment of coronary artery disease. Their effectiveness is limited by the occurrence of restenosis. Previous studies have suggested that the level of restenosis may be related to the deployed stent geometry, and in particular to the symmetry of the deployment profile. It is suggested that the symmetry of deployment might be influenced by the folding pattern of the balloon on which the stent is delivered. This paper describes a stereo-photogrammetric system for the three-dimensional reconstruction of stent geometry during expansion, including appropriate specification and calibration procedures. Calibration testing of the system indicated an accuracy of +/-0.05 mm in the reconstruction of the position of a point on the stent surface. Methods for processing the 3D data are described, including a technique for quantitatively differentiating between results from two alternative balloon folding patterns. This study may aid future balloon and stent design with respect to the optimization of stent deployment characteristics.

Biomechanical Phenomena↗

Automatic segmentation of medical images using image registration: diagnostic and simulation applications.

Automatic identification of the boundaries of significant structure (segmentation) within a medical image is an are of ongoing research. Various approaches have been proposed but only two methods have achieved widespread use: manual delineation of boundaries and segmentation using intensity values. In this paper we describe an approach based on image registration. A reference image is prepared and segmented, by hand or otherwise. A patient image is registered to the reference image and the mapping then applied to ther reference segmentation to map it back to the patient image. In general a high-resolution nonlinear mapping is required to achieve accurate segmentation. This paper describes an algorithm that can efficiently generate such mappings, and outlines the uses of this tool in two relevant applications. An important feature of the approach described in this paper is that the algorithm is independent of the segmentation problem being addresses. All knowledge about the problem at hand is contained in files of reference data. A secondary benefit is that the continuous three-dimensional mapping generated is well suited to the generation of patient-specific numerical models (e.g. finite element meshes) from the library models. Smoothness constraints in the morphing algorithm tend to maintain the geometric quality of the reference mesh.

Algorithms↗

The origin and significance of secondary flows in the aortic arch.

This paper comprises a study of the secondary flow patterns that can develop in the human aortic arch. Clinical evidence of these secondary flows has been obtained by Kilner et al. using magnetic resonance velocity mapping techniques. Some of their results are presented for comparison in this paper. Four difference parametric models of the aortic arch have been analysed using computational fluid dynamic techniques. Both steady and transient flow conditions have been considered and two different commercially available software packages were used, namely FIDAP and FLOTRAN. A satisfactory comparison of the theoretical analysis with the results, both in vivo and in vitro, obtained by Kilner et al. for their out-of-plane inlet model was found. The theoretical analysis can now be extended to analyse the effect of different configurations and orientations of artificial aortic valves on the resulting aortic arch flow patterns.

Aorta, Thoracic↗

An examination of one-piece metacarpophalangeal joint implants using finite element analysis.

Reconstruction of the rheumatoid metacarpophalangeal (MCP) joint is generally achieved by means of implantation of a hinged silastic prosthesis. These implants reduce the pain in joint and restore some degree of mobility. However, they are prone to failure after a relatively short life-span. In this study, two popular designs of MCP implant, the Swanson and the Sutter, were compared by means of three-dimensional finite element analysis. The aim was to examine how the differing geometry effected their relative stiffness as replacement joints, and whether they were inherently prone to high stress concentrations during flexion. Although the Swanson design implant exhibited relatively greater resistance to flexion, both designs showed regions of high stress concentration and it was noted that neither was without its limitations. The use of the finite element technique was found to be an excellent way to provide preliminary design evaluation information, allowing further evolution before clinical trials.

Arthritis, Rheumatoid↗