The Longitudinal Assessment of Imaging and Disability of the Back (LAIDBack) Study: baseline data.

STUDY DESIGN: Prospective cohort study of randomly selected Veterans Affairs (VA) outpatients. OBJECTIVE: To determine the prevalence of magnetic resonance imaging (MRI) findings in the lumbar spine among persons without current low back pain or sciatica and to examine which findings are related to age or previous back symptoms. SUMMARY OF BACKGROUND INFORMATION: Previous studies of patients without low back pain have not explored the possible association of various MRI findings to past symptoms. METHODS: We randomly selected an age-stratified sample of subjects without low back pain in the past 4 months from clinics at a VA hospital. We collected information on demographics, comorbidity, functional status, and quality of life. MR images were obtained using a standardized protocol through each of the five lumbar disc levels. RESULTS: Of 148 subjects, 69 (46%) had never experienced low back pain. There were 123 subjects (83%) with moderate to severe desiccation of one or more discs, 95 (64%) with one or more bulging discs, and 83 (56%) with loss of disc height. Forty-eight subjects (32%) had at least one disc protrusion and 9 (6%) had one or more disc extrusions. CONCLUSION: Many MR imaging findings have a high prevalence in subjects without low back pain. These findings are therefore of limited diagnostic use. The less common findings of moderate or severe central stenosis, root compression, and extrusions are likely to be diagnostically and clinically relevant.

Adult↗

Image acquisition: ultrasound, computed tomography, and magnetic resonance imaging.

As the transition toward total digital image acquisition continues, radiology is transcending the current standard of two-dimensional (2-D) cross-sectional anatomic imaging to more complex models. Among these are three-dimensional (3-D) anatomic images, constructed either from a synthesis of traditional 2-D data sets, or directly from volumetrically acquired data. However, current trends are moving beyond mere anatomic imaging to include physiological data once mainly obtained via nuclear medicine. Recent magnetic resonance pulse sequences, in addition to Doppler and harmonic ultrasound methods, are providing insight into blood flow, oxygenation, and metabolite concentrations non-invasively. Through image registration techniques, these data (even from differing modalities) are being assembled into 2-D and 3-D "fusion" images that promise to revolutionize diagnosis. Furthermore, with improvements in miniaturization, reliability, speed, built-in intelligence, and ease of use, these new developments are finding their way into use by nonspecialists. For instance, a new hand-held ultrasound unit will likely become a common tool among emergency medical teams, military medical teams, and in NASA's manned space program. Portable computed tomography (CT) scanners are already being used in the operating room. The increasing sophistication of imaging instruments will bring about a complementary increase in ease of use for both scanning and data interpretation, bringing diagnostic imaging and therapeutic capabilities closer to the patient, rather than the converse.

Diagnostic Imaging↗

A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer.

We have developed a fast calibration method for computing the position and orientation of 2-D ultrasound (US) images in 3-D space where a position sensor is mounted on the US probe. This calibration is required in the fields of 3-D ultrasound and registration of ultrasound with other imaging modalities. Most of the existing calibration methods require a complex and tedious experimental procedure. Our method is simple and it is based on a custom-built phantom. Thirty N-fiducials (markers in the shape of the letter "N") embedded in the phantom provide the basis for our calibration procedure. We calibrated a 3.5-MHz sector phased-array probe with a magnetic position sensor, and we studied the accuracy and precision of our method. A typical calibration procedure requires approximately 2 min. We conclude that we can achieve accurate and precise calibration using a single US image, provided that a large number (approximately ten) of N-fiducials are captured within the US image, enabling a representative sampling of the imaging plane.

Calibration↗

Validating clustering for gene expression data.

MOTIVATION: Many clustering algorithms have been proposed for the analysis of gene expression data, but little guidance is available to help choose among them. We provide a systematic framework for assessing the results of clustering algorithms. Clustering algorithms attempt to partition the genes into groups exhibiting similar patterns of variation in expression level. Our methodology is to apply a clustering algorithm to the data from all but one experimental condition. The remaining condition is used to assess the predictive power of the resulting clusters-meaningful clusters should exhibit less variation in the remaining condition than clusters formed by chance. RESULTS: We successfully applied our methodology to compare six clustering algorithms on four gene expression data sets. We found our quantitative measures of cluster quality to be positively correlated with external standards of cluster quality.

Algorithms↗

An investigation of the importance of myocardial anisotropy in finite-element modeling of the heart: methodology and application to the estimation of defibrillation efficacy.

Finite-element (FE) modeling has been widely used in studies of bioelectric phenomena of tissues, including ventricular defibrillation. Most FE models, whether built from anatomical atlases or subject-specific tomographic images, treat the myocardium as an isotropic tissue. However, myocardium has been experimentally shown to have significant anisotropy in its resistivities, although myocardial fiber directions are difficult to measure on a subject-specific basis. In this paper, we: 1). propose a method to incorporate a widely known myocardial fiber direction model to a specific individual and 2). assess the effects of myocardial anisotropy on myocardial voltage gradients computed for a study of implantable defibrillators. The thoracic FE model was built from CT images of a young pig, and the myocardial fiber structures were incorporated via elastic mapping. Our results demonstrate a good mapping of geometry between the source and target hearts with an average root-mean-square error of less than 2.3 mm and a mapped fiber pattern similar to those known to exist in vivo. With the mapped fiber information, we showed that the estimated minimal myocardial voltage gradient over 80% of the myocardium differs by less than 10% between using an isotropic and anisotropic myocardial models. Thus, myocardial anisotropy is expected to have only a small effect on estimates of defibrillation threshold obtained from computed voltage gradients. On the other hand, anisotropy may be essential if defibrillation efficacy is analyzed by transmembrane voltage of the myocardial cells.

Animals↗

A finite-element study of the effects of electrode position on the measured impedance change in impedance cardiography.

Traditional impedance cardiography (ICG) technique uses band electrodes both for delivering current to and measuring impedance change in the thorax. The use of spot electrodes increases the ease of electrode placement and comfort level for patients. Research has shown that changes in thoracic impedance can have multiple causes. In this study, we used finite element modeling to investigate the sources of impedance change for both band-electrode and spot-electrode ICG, and focused on how differences in electrode location affect the contribution of different sources to changes in impedance. The ultimate purpose is to identify the optimal electrode type and placement for the sensing of stroke volume (SV). Our models were built on sets of end-diastolic and end-systolic magnetic resonance images of a healthy human subject. The results showed that the effect of ventricular contraction is opposite to that of the other changes in systole: the expansion of major vessels, decrease in blood resistivity due to increased blood flow velocity, and decrease in lung resistivity due to increased blood perfusion. Ventricular contraction, the only factor that tends to increase systolic impedance, has a larger effect than any of the other factors. When spot electrodes are placed on the anterior chest wall near the heart, ventricular contraction is so dominant that the measured impedance increases from end-diastole to end-systole, and the change represents 82% of the contribution from ventricular contraction. When using the common band-electrode configuration, the change in measured impedance is a more balanced combination of the four effects, and ventricular contraction is overcome by the other three factors so that the impedance decreases. These results suggest that the belief that ICG can be used to directly measure SV based on the change in the whole thoracic impedance may be invalid, and that spot electrodes may be more useful for understanding local physiological events such as ventricular volume change. These findings are supported by previously reported experimental observations.

Adult↗

Ghost imaging for targeting breast masses with MR imaging: a phantom study.

RATIONALE AND OBJECTIVES: The purpose of this study was to test the accuracy of ghost magnetic resonance (MR) imaging for guiding core biopsies of simulated breast masses in a tissue phantom. MATERIALS AND METHODS: A tissue MR phantom implanted with 20 grapes as targets was placed into an interventional breast MR coil. The locations of the centers of the targets were determined, recorded, and saved as ghost images. A nonmagnetic phantom needle was constructed to avoid imprecision secondary to magnetic field inhomogeneity and was used to determine the three-dimensional location of the needle tip in the center of each grape on the ghost image. Once the positions were determined, the true needle was placed and biopsy specimens were taken. The needle was inspected for the presence of pulp after each pass. Each grape was inspected to determine the location of the needle track in relation to the center of the grape. The duration of the procedure was recorded. RESULTS: All grapes were hit by the biopsy needle, as demonstrated either by pulp within the needle or by a needle track within the grape. Seventeen of the 20 grapes (85%) were hit centrally. Three were sampled eccentrically, up to 5-6 mm from the center. Each biopsy took approximately 1 hour. CONCLUSION: These results suggest that ghost imaging may be ideal for needle guidance in core biopsy or preoperative localization, as it extends the period of visibility after a bolus injection of contrast material. Additionally, using a phantom needle for localization appears to overcome imprecision due to magnetic field inhomogeneity of the needle.

Animals↗

Edge-guided boundary delineation in prostate ultrasound images.

Accurate detection of prostate boundaries is required in many diagnostic and treatment procedures for prostate disease. In this paper, a new paradigm for guided edge delineation is described, which involves presenting automatically detected prostate edges as a visual guide to the observer, followed by manual editing. This approach enables robust delineation of the prostate boundaries, making it suitable for routine clinical use. The edge-detection algorithm is comprised of three stages. An algorithm called sticks is used to enhance contrast and at the same time reduce speckle in the transrectal ultrasound prostate image. The resulting image is further smoothed using an anisotropic diffusion filter. In the third stage, some basic prior knowledge of the prostate, such as shape and echo pattern, is used to detect the most probable edges describing the prostate. Finally, patient-specific anatomic information is integrated during manual linking of the detected edges. The algorithm was tested on 125 images from 16 patients. The performance of the algorithm was statistically evaluated by employing five expert observers. Based on this study, we found that consistency in prostate delineation increases when automatically detected edges are used as visual guide during outlining, while the accuracy of the detected edges was found to be at least as good as those of the human observers. The use of edge guidance for boundary delineation can also be extended to other applications in medical imaging where poor contrast in the images and the complexity in the anatomy limit the clinical usability of fully automatic edge-detection techniques.

Algorithms↗

Analysis of defibrillation efficacy from myocardial voltage gradients with finite element modeling.

Increasing defibrillation efficacy by lowering the defibrillation threshold (DFT) is an important goal in positioning implantable cardioverter-defibrillator electrodes. Clinically, the DFT is difficult to estimate noninvasively. It has been suggested that the DFT relates to the myocardial voltage gradient distribution, but this relation has not been quantitatively demonstrated. We analyzed the relation between the experimentally measured DFT's and the simulated myocardial voltage gradients provided by finite element modeling. We performed a series of experiments in 11 pigs to measure the DFT's, and created and solved three-dimensional subject-specific finite element models to assess the correlation between the computed myocardial voltage gradient histograms and the DFT's. Our data show a statistically significant correlation between the DFT and the left ventricular voltage gradient distribution, with the septal region being more significant (correlation coefficient of 0.74) than other myocardial regions. The correlation between the DFT and the right ventricular and the atrial voltage gradient, on the other hand, is not significant.

Animals↗

Interactive 3-D registration of ultrasound and magnetic resonance images based on a magnetic position sensor.

The use of stereotactic systems has been one of the main approaches for image-based guidance of the surgical tool within the brain. The main limitation of stereotactic systems is that they are based on preoperative images that might become outdated and invalid during the course of surgery. Ultrasound (US) is considered the most practical and cost-effective intraoperative imaging modality, but US images inherently have a low signal-to-noise ratio. Integrating intraoperative US with stereotactic systems has recently been attempted. In this paper, we present a new system for interactively registering two-dimensional US and three-dimensional magnetic resonance (MR) images. This registration is based on tracking the US probe with a dc magnetic position sensor. We have performed an extensive analysis of the errors of our system by using a custom-built phantom. The registration error between the MR and the position sensor space was found to have a mean value of 1.78 mm and a standard deviation of 0.18 mm. The registration error between US and MR space was dependent on the distance of the target point from the US probe face. For a 3.5-MHz phased one-dimensional array transducer and a depth of 6 cm, the mean value of the registration error was 2.00 mm and the standard deviation was 0.75 mm. The registered MR images were reconstructed using either zeroth-order or first-order interpolation. The ease of use and the interactive nature of our system (approximately 6.5 frames/s for 344 x 310 images and first-order interpolation on a Pentium II 450 MHz) demonstrates its potential to be used in the operating room.

Algorithms↗

Differential attenuation method for simultaneous estimation of activity and attenuation in multiemission single photon emission computed tomography.

A penalized weighted least squares reconstruction algorithm is described that simultaneously estimates activity and attenuation distributions from emission sinogram data alone. This estimation technique is based on differential attenuation information and is applicable to any single photon emission computed tomography imaging isotope with emissions at two or more distinct energies, after accurate compensation for Compton scatter. A rotation-based forward projector is used to efficiently model photon attenuation at multiple emission energies, as well as distance-dependent spatial resolution. The algorithm was tested using simulated scatter-free 201T1 projection data from a single-slice numerical cardiac phantom with and without cold myocardial defects. Poisson noise was added to the projection data to mimic clinically realistic count densities. The activity estimates resulting from the proposed method had fewer artifacts and were substantially more accurate than images reconstructed with filtered backprojection without compensation for attenuation. Several techniques were employed to reduce the time required for the iterative routine to converge and to reduce the sensitivity of the solution to noise in the projection data. These included: (1) a preconditioning image variable transformation; (2) a coarse-to-fine grid initialization schedule; and (3) a convex hull image mask determined directly from the data. The combined effect of these techniques substantially reduced the compute time required for the reconstruction.

Algorithms↗

MR contrast media in neuroimaging: a critical review of the literature.

BACKGROUND AND PURPOSE: MR contrast media are commonly used but do not have evidence-based guidelines for their application. This investigation seeks to define specific methodological problems in the MR contrast media literature and to suggest guidelines for an improved study design. METHODS: To evaluate the reported clinical efficacy of MR contrast media in neuroimaging, we performed a critical review of the literature. From 728 clinical studies retrieved via MEDLINE, we identified 108 articles that evaluated contrast media efficacy for a minimum of 20 patients per study. The articles were randomly assigned to four readers (a fifth reader reviewed all of the articles) who were blinded to article titles, authors, institutions, and journals of publication. The readers applied objective, well-established methodological criteria to assign each article a rating of A, B, C, or D. RESULTS: One hundred one of 108 articles received a D rating, six received a C rating, and one received a B rating. In general, the Methods sections of the evaluated articles did not contain details that would allow the reader to calculate reliable measures of diagnostic accuracy, such as sensitivity and specificity. Specifically, a common problem was failure to establish and uniformly apply an acceptable standard of reference. In addition, images were not always interpreted independently from the reference standard. Radiologists and clinicians need to determine the applicability of any published study to their own practices. Unfortunately, the studies we reviewed commonly lacked clear descriptions of patient demographics, the spectrum of symptomatology, and the procedure for assembling the study cohort. Finally, small sample sizes with inadequate controls were presented in almost all of the articles. CONCLUSION: Although MR contrast media are widely used and play an essential role in lesion detection and confidence of interpretation, no rigorous studies exist to establish valid sensitivity and specificity estimates for their application. On the basis of this review, we herein describe basic methods to document improvements in technology. Such studies are essential to devise measures of diagnostic accuracy, which can form the basis for further studies that will assess diagnostic and therapeutic impact and, ultimately, patient outcomes.

Cohort Studies↗

Geometric effects on resistivity measurements with four-electrode probes in isotropic and anisotropic tissues.

We studied via computer simulation the effects of electrode diameter, electrode length, interelectrode spacing, and tissue size on the accuracy of measured tissue resistivities and anisotropy ratios obtained with the widely used four-electrode technique. Such measurements commonly assume an ideal situation in which the four electrodes are infinitesimally small and the tissue is semi-infinite. Our study shows that these geometric factors can significantly affect measured resistivities, particularly for anisotropic tissues. The measured anisotropy ratio is decreased by either 1) increasing the electrode diameter or length relative to the interelectrode spacing of the probe or 2) decreasing tissue size. We have provided an equation for estimating errors in the measured anisotropy ratio from the parameters of electrode and tissue geometries. The simulation findings are supported by our in vitro experimental results.

Animals↗

Sensitivity of transvenous defibrillation models to adaptive mesh density and resolution: the potential for interactive solution times.

The voltage gradients induced in ventricular myocardium by an electric shock have been shown to correlate to the probability of the shock producing a successful defibrillation. Finite element modeling is one method for computing these voltage gradients, although the meshing of complex biomedical domains is difficult on a patient-specific basis. We recently described an adaptive algorithm that automates the generation of finite element meshes for complex 3-D domains from bitmapped images. This article examines the sensitivity of the computed distribution of ventricular voltage gradients to the resolution of the images and to the adapted density of the mesh. The results allow us to establish an adaptation stopping criterion and a minimum input image resolution for modeling transvenous defibrillation. The sensitivity to adapted mesh density was analyzed by comparing voltage gradient histograms from successively finer meshes to histograms from a uniform mesh at the maximum possible density. Comparisons were made using the Kolmogorov-Smirnov test with the number of samples required to detect a 5% difference in the histograms at the 0.05 significance level. Adaptation to a global current density error estimate of 5% or less was required in order to achieve acceptance of the null hypothesis that the distributions were the same in all cases. Defibrillation efficacy, however, is predicted from the voltage gradient in the first quartile, and the results suggest that this region of the cumulative histogram converges faster during mesh adaptation than the histogram as a whole. We also compared histograms from models generated from successively finer input images. The histogram of each model was compared with the histogram obtained from the finest possible resolution. In all cases, the null hypothesis of no difference was accepted at resolutions of 2.3 x 2.3 x 3.0 mm. The average time required to build and adapt models to a 5% accuracy at the first quartile at this resolution was 1.8 min. on a common workstation. We believe that this demonstrates a potential for the eventual synthesis of finite element computations into interactive electrode placement tools on a subject-specific basis.

Algorithms↗

Rapid MR imaging versus plain radiography in patients with low back pain: initial results of a randomized study.

PURPOSE: To demonstrate the feasibility of a randomized trial to compare rapid magnetic resonance (MR) imaging with plain radiography as the initial imaging study in patients with low back pain, to test measures of the decision-making process and patient outcomes, and to offer a model for using randomized clinical trials to evaluate diagnostic tests. MATERIALS AND METHODS: The authors randomly selected 62 patients with low back pain to undergo either rapid MR imaging or plain radiography. The authors measured functional status, satisfaction, and general health status at baseline and at 3 months. The modified Roland scale was the primary outcome measure. In addition, the authors examined diagnostic and therapeutic decision making and resources used by each group. RESULTS: There were no statistically significant differences between the two patient groups with respect to outcome (Roland score: MR imaging = 12.5, radiography = 12.1). MR imaging provided more useful information to clinicians and resulted in greater patient reassurance. CONCLUSION: Randomly selecting patients to undergo imaging examinations and measuring outcomes is feasible; however, a larger, multicenter study is necessary to determine whether rapid MR imaging is a cost-effective replacement for plain radiography in patients with low back pain.

Adult↗

Object-free adaptive meshing in highly heterogeneous 3-D domains.

Traditional approaches to the generation of finite element meshes are well suited for modeling the homogeneous or mildly heterogeneous domains presented by man-made objects, but are difficult to apply to the complex 3-D domains encountered in some biomedical applications. In this paper, we describe an adaptive algorithm that automates the modeling of these domains. The method differs from traditional approaches in that no explicit description is required of the boundaries between objects with dissimilar material properties. The algorithm uses images of the tissue class to build irregular meshes, and continuity is enforced by constraining the solution at irregular nodes. Local estimates of the error in the flux solution are used to refine the mesh. For an analytic problem with a rapid change along a spherical boundary, the adaptive method converges to a 1% voltage error using 25% of the degrees of freedom required by a uniform refinement, and to a 5% voltage gradient error using 11% of the degrees of freedom. For a defibrillation model in a pig thorax, the voltage gradient solution in the ventricles of the heart converges to within 5% of a uniform mesh solution using less than 8% of the memory and processing resources required by a uniform mesh, which has been the only practical alternative for subject-specific modeling.

Algorithms↗

Automatic fetal head measurements from sonographic images.

RATIONALE AND OBJECTIVES: We designed an image processing technique to automatically measure the biparietal diameter (BPD) and head circumference (HC) from prenatal sonograms. We evaluated the performance of the algorithm by comparing the resulting measurements with those made by experienced sonographers. METHODS: Thirty-five digitized sonograms of the fetal head were obtained during routine imaging. The BPD and HC were automatically computed by detecting the inner and outer boundaries of the fetal skull using the computer vision technique known as the "active contour model." Six experienced sonographers also measured the BPD and HC on these images. RESULTS: The algorithm failed to locate the boundaries in two of the 35 cases. For the remaining cases, the mean absolute difference between the automated measurements and the average of the six observers was 1.4% for BPD and 2.9% for HC. The correlations were .999 for the BPD and .994 for the HC. The computer's measurements were no different from the six observers' measurements than the observers' measurements were from one another. CONCLUSION: The tested algorithm effectively and accurately measures BPD and HC automatically. We are currently in the process of integrating this algorithm into an ultrasound machine.

Algorithms↗

Interreader reliability for a new classification of lumbar disk disease.

RATIONALE AND OBJECTIVES: The nomenclature that divides disk herniations into protrusions and extrusions may increase the specificity of magnetic resonance (MR) imaging for clinically important lesions. Our goal was to determine this terminology's interreader reliability. METHODS: Three readers who were unaware of patients' histories independently read MR images of 34 consecutive patients with back pain. Readers classified disks at the lowest three lumbar levels as normal, bulging, protruded, or extruded. Kappa and weighted kappa values were the primary measures of agreement. RESULTS: Weighted kappa values showed fair-to-moderate agreement. Kappas for the dichotomous decision of extrusion present or absent were more variable, ranging from 0 to .78. Major disagreements (greater than a single category) occurred with 6.2% of all comparisons and in 10 of 34 volunteers; five involved extrusions. CONCLUSION: Overall, readers achieved moderate agreement for this new nomenclature. However, agreement for the presence or absence of an extrusion was less reliable.

Adult↗