Kernicterus in a full term infant.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D R Enzmann.
Explore the source record for details and available documents.
Time-of-flight and phase shift methods have both been used for vascular imaging with magnetic resonance. Phase methods, and phase contrast in particular, are well suited to quantitative measurements of velocity and volume flow rate. The most robust methods for measuring flow encode through-plane velocity into phase shift and compute flow by integrating the measured velocity over the vessel lumen. The accuracy of the flow data can be degraded by the effects of acceleration and eddy currents and by partial volume effects, including the effects of finite slice thickness and resolution, pulsatile waveforms, motion, and chemical shift. The reproducibility depends on the signal-to-noise of the data and the strength of the flow encoding and can be degraded by inconsistent definition of the vessel boundary. The adjustable flow sensitivity inherent in this method is a particular asset, allowing phase contrast flow measurement to operate over a dynamic range exceeding 10(5). Recently developed rapid imaging methods are helpful in applications that would be compromised by respiratory motion. With care, excellent quantitative data can be quickly obtained in vivo, and the resulting flow information is valuable for the diagnosis and management of a variety of conditions.
Explore the source record for details and available documents.
PURPOSE: To measure mean blood flow in individual cerebral arteries (carotid, basilar, anterior cerebral, middle cerebral, and posterior cerebral) using a cine phase contrast MR pulse sequence. METHODS: Ten healthy volunteers (22 to 38 years of age) were studied. The cine phase-contrast section was positioned perpendicular to the vessel of interest using oblique scanning planes. This pulse sequence used a velocity encoding range of 60 to 250 cm/sec. From the velocity and area measurements on the cine images, mean blood flow was calculated in milliliters per minute and milliliters per cardiac cycle. In the same subjects, transcranial Doppler measurements of blood velocity in these same vessels were also obtained. RESULTS: There was no difference in blood flow in the paired cerebral arteries. Carotid arteries had mean blood flow in the range of 4.8 +/- 0.4 ml/cycle, the basilar artery 2.4 +/- 0.2 ml/cycle, the middle cerebral artery 1.8 +/- 0.2 ml/cycle, the distal anterior cerebral artery 0.6 +/- 0.1 ml/cycle, and the posterior cerebral artery 0.8 +/- 0.1 ml/cycle. Overall, there was poor correlation between MR-measured and transcranial Doppler-measured peak velocity. CONCLUSION: Although careful attention to technical detail is required, mean blood flow measurements in individual cerebral vessels is feasible using a cine phase-contrast MR pulse sequence.
PURPOSE: To compare lesion enhancement after injection of gadopentetate dimeglumine on spin-echo and gradient-echo T1-weighted images. METHODS: A total of 48 contrast-enhancing intracranial lesions were evaluated using a spin-echo and two gradient-echo T1-weighted pulse sequences. Percent contrast, contrast-to-noise, and signal-to-noise measurements were made on the spin-echo T1-weighted, three-dimensional gradient-echo, and multiplanar gradient-echo sequences. RESULTS: The measurements were somewhat different for the following categories of lesions: extraaxial, intraaxial with edema, and intraaxial without edema. The latter group provided the greatest diagnostic challenge: three of 19 such lesions 1 cm in size or smaller could not be identified on three-dimensional gradient-echo images, and one could not be identified on multi-planar gradient-echo images. The spin-echo T1-weighted sequence demonstrated significantly higher percent contrast (P < .05) and greater contrast to noise (P < .03) than either gradient-echo sequence for these small intraaxial lesions without edema. For extraaxial and intraaxial lesions with edema, percent C was similar for spin-echo T1-weighted and three-dimensional gradient-echo images, while contrast to noise was greater for spin-echo T1-weighted images. This reflected greater tissue noise with gradient-echo sequences. CONCLUSION: The T1-weighted spin-echo sequence was preferred for detecting the full spectrum of contrast-enhancing lesions of the central nervous system.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: Spiral CT allows continuous data to be acquired rapidly, and if a correctly timed IV bolus of contrast material is given, spiral CT angiography can be performed. This study was designed to evaluate spiral CT angiography with maximum-intensity-projection reconstructions for assessing the degree of carotid artery stenosis. SUBJECTS AND METHODS: Spiral CT angiography (of 28 carotid bifurcations in 14 patients) was compared in a blinded fashion with conventional angiography (of 28 bifurcations) and with two-dimensional time-of-flight MR angiography (of 12 bifurcations) to assess degree of stenosis. A nonblinded comparison of the contour of the lumen at the site of stenosis was then made between conventional angiography, spiral CT angiography, and MR angiography. The degree of stenosis was measured in each internal carotid artery and categorized as mild (< 30%), moderate (30-69%), or severe (70-99%) stenosis or as occlusion. Maximum-intensity-projection images were used for the evaluations; however, if calcification was circumferential and the lumen of the carotid artery could not be analyzed in the area of the calcification, the axial source images were used. RESULTS: The results of CT angiography and conventional angiography agreed overall in 25 (89%) of 28 cases (r = .921, p = .05, Spearman rank correlation). The presence of severe stenosis or occlusion was correctly identified in seven of seven cases. In the moderate and mild stenosis categories, 18 (86%) of 21 were correctly identified (r = .802, p = .122). Three internal carotid arteries (11%) had circumferential calcification that necessitated evaluation of the axial source images, and the measurements obtained from the axial images agreed well with angiographic findings. MR angiography correlated well with the various categories of stenosis. However, when we compared MR angiography directly with CT angiography and conventional angiography, we found that the degree of stenosis was overestimated when MR angiography was used. CONCLUSION: Our results show that spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional angiography. The short examination time and clear depiction of arterial caliber in areas of stenosis are significant advantages of spiral CT angiography compared with MR angiography.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Time-of-flight (TOF) angiography based on inflow enhancement is limited by the steady-state signal differences between blood and the surrounding stationary tissues. We present a new TOF sequence in which magnetization transfer contrast is used to supplement wash-in effects. Angiograms demonstrating the superior performance of this technique are presented.
This study evaluated a phase-contrast cine magnetic resonance (MR) imaging technique capable of simultaneously allowing determination of velocity and volume flow rate (VFR) in both carotid arteries and the basilar artery. Forty patients were studied; 24 were neurologically normal, and 16 had intracerebral arteriovenous malformations (AVMs). In the normal group, mean basilar flow was significantly less than mean carotid flow. Mean velocity and VFR showed a significant decline with age in the basilar artery. Carotid artery flow and total cerebral blood flow did not decline with age. In the AVM patients, flow and velocity measurements were significantly elevated in all three arteries. Flow in the carotid artery ipsilateral to the AVM was significantly greater than flow in the contralateral carotid artery. VFR increased in all three arteries with increasing AVM volume. Four patients underwent partial embolization, and a corresponding decrease in flow was observed. Phase-contrast cine MR imaging provides rapid, simultaneous, noninvasive velocity and VFR measurement in the major intracranial arteries.
The authors describe a technique for obtaining angiographic images by means of spiral computed tomography (CT), preprocessing of reconstructed three-dimensional sections to suppress bone, and maximum intensity projection. The technique has some limitations, but preliminary results in 48 patients have shown excellent anatomic correlation with conventional angiography in studies of the abdomen, the circle of Willis in the brain, and the extracranial carotid arteries. With continued development and evaluation, CT angiography may prove useful as a screening tool or replacement for conventional angiography in some patients.
Brain motion during the cardiac cycle was measured prospectively in 10 healthy volunteers by using a phase-contrast cine magnetic resonance (MR) pulse sequence. The major cerebral lobes, diencephalon, brain stem, cerebellum, cerebellar tonsils, and spinal cord were studied. The overall pattern of brain motion showed caudal motion of the central structures (diencephalon, brain stem, and cerebellar tonsils) shortly after carotid systole, with concurrent cephalic motion of the major cerebral lobes and posterior cerebellar hemisphere. Peak brain displacement was in the range of 0.1-0.5 mm for all the structures except the cerebellar tonsils, which had greater displacement (0.4 mm +/- 0.16 [mean +/- standard error of mean]). Caudal motion of the central structures did not occur simultaneously but progressed in a caudal-to-rostral and posterior-to-anterior sequence, being seen first in the cerebellar tonsils and then later in the diencephalon (hypothalamus). Caudal motion of the low brain stem and cerebellar tonsil was simultaneous with caudal motion of cerebrospinal fluid in the cervical subarachnoid space. Oscillatory flow in the aqueduct was delayed compared with brain stem motion.
Fast spin-echo (FSE) magnetic resonance (MR) imaging was compared with conventional, peripherally gated T2-weighted spin-echo (SE) imaging in the detection of high- and low-signal-intensity lesions in the central nervous system. Lesion detectability was determined with percentage of contrast measurements and contrast-to-noise ratios with two different measurements for noise. All three measures of lesion detectability were similar. FSE and SE sequences were quantitatively equivalent in the detection of high-signal-intensity lesions. The SE sequence, however, was superior to the FSE sequence in the detection of small, low-signal-intensity lesions in the central nervous system caused by magnetic susceptibility effects.
Because of great inter-individual variability in the sizes and configurations of monkey brains, consistent intracerebral stereotaxic placements are not possible when a general brain atlas is relied upon to derive placement coordinates. We describe a procedure that allows the determination of brain atlases for individual monkeys using proton magnetic resonance imaging and the translation of image coordinates to stereotaxic coordinates. The latter is accomplished by chronically implanting glass beads filled with copper sulfate into the skull to establish a plane horizontal to the stereotaxic plane and to provide reference points for zeroing stereotaxic carriers during intracerebral implants. The efficacy of this procedure was confirmed experimentally.
A phase-contrast cine magnetic resonance (MR) imaging technique was used to study normal dynamics of cerebrospinal fluid (CSF) in 10 healthy volunteers and four patients with normal MR images. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle (peripheral gating). Flow encoding depicted craniocaudal flow as high signal intensity and caudo-cranial flow as low signal intensity. Sagittal and axial images of the head, cervical spine, and lumbar spine were obtained, and strategic sites were analyzed for quantitative CSF flow. The onset of CSF systole in the subarachnoid space was synchronous with the onset of systole in the carotid artery. CSF systole and diastole at the foramen of Monro and aqueduct were essentially simultaneous. The systolic and diastolic components were different in the subarachnoid space, where systole occupied approximately 40% and diastole 60% of the cardiac cycle, compared with the ventricular system, where they were equal. This difference results in systole in the intracranial and spinal subarachnoid spaces preceding that in the ventricular system; the same is true for diastole. The fourth ventricle and cisterna magna serve as mixing chambers. The high-velocity flow in the cervical spine and essentially no flow in the distal lumbar sac indicate that a portion of the capacitance necessary in this essentially closed system resides in the distal spinal canal.
Phase contrast cine magnetic resonance imaging (MRI) combines the flow-dependent contrast of phase contrast MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. Two pulse sequence types are used for sensitivity to flow in one direction, whereas four are needed for sensitivity in all directions. Several alternatives for synchronization of the data to the cardiac cycle exist. Retrospectively interpolated methods can image the entire cardiac cycle efficiently. Rapid interleaving of the various sequence types ensures immunity to motion misregistration. The technique produces images in which contrast is related to flow velocity as well as magnitude images such as those of conventional cine MRI. The data can be interpreted qualitatively to demonstrate the presence, magnitude, and direction of flow, and quantitatively to provide estimates of flow velocity, volume flow rate, and displaced volumes. Phase contrast cine MRI is helpful in the diagnosis of aortic dissections, in the study of flow distributions in large vessels such as pulmonary arteries, as well as in smaller vessels such as carotid and basilar arteries, and in the evaluation of complex anatomical variants. Future developments are expected to reduce imaging time and expand the quantitative applications.