Highly sensitive glucose sensor based on work function changes measured by an EMOSFET.

In this paper, glucose is potentiometrically measured by using a specific field effect transistor, the EMOSFET. In this device, glucose oxidase is immobilized within a bovine serum albumin matrix, using glutaraldehyde. This layer is deposited on the top of an electroactive Os-polyvinylpyridine layer containing horseradish peroxidase, which is used as the gate material of the FET. The basic principle of the sensor is to measure the glucose concentration by means of measuring the change in the work function of the electroactive gate due to its redox reaction with the H2O2, generated by the reaction between glucose and glucose oxidase. The change in the work function can be detected as a change in the threshold voltage of the FET. Moreover, a measuring mode called "constant current potentiometry" has been applied to improve the sensitivity of the sensor. The sensitivity of the sensor working in this mode is found to be much higher than the Nernstian value. The experimental results show that the detection limit of the sensor can be tuned depending on the value of the applied current and the glucose oxidase concentration in the gate.

Biosensing Techniques↗

A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors.

A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 microm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few microl of an appropriate enzyme solution, an amperometric enzyme sensor results. As the dialysis tubing is impermeable for large molecular species such as enzymes, this approach does not require any immobilization chemistry, and as a consequence the enzyme is present in its natural free form. Based on this principle, amperometric sensors for lactate, glucose, and glutamate were formed by filling cavities, precision machined in Perspex, with buffered solutions containing respectively, lactate-, glucose-, and glutamate-oxidase. All sensors showed a large linear range (0-35 mM for glucose, 0-3 mM for lactate, and 0-5 mM for glutamate) covering the complete physiological range. The lower detection limit was in the order of 15-50 microM. Applicability in flow injection analysis systems is demonstrated.

Biosensing Techniques↗