Search PubMed⌕ Search

Biomedical subjects

D P Hanson

Publications and source records attributed to D P Hanson.

10 recordsLinked to original sources

Stress and sleep patterns of college students.

The present study investigated the relationship between stress and sleep. A self-report measure was used to assess three domains: environmental events, personality mediators, and emotional responses. It was hypothesized that one or more of the domains would predict seven different aspects of sleep. 227 college students completed the Derogatis Stress Profile and the Sleep Questionnaire. Analysis indicated that scores on emotional response were the best predictor of five different sleep aspects: depth of sleep, difficulties in waking up, quality and latency of sleep, negative affect in dreams, and sleep irregularity. Presence of environmental events was the best predictor for the length of sleep only. It was concluded that research looking at the effects of stress on sleep must consider all three components of stress and that perhaps the emotional response to stress is the best predictor of sleep complaints.

Adaptation, Psychological↗

Quantitative and clinical analysis of SPECT image registration for epilepsy studies.

UNLABELLED: This study reports quantitative measurements of the accuracy of two popular voxel-based registration algorithms--Woods' automated image registration algorithm and mutual information correlation--and compares these with conventional surface matching (SM) registration. METHODS: The registration algorithms were compared (15 different matches each) for (a) three-dimensional brain phantom images, (b) an ictal SPECT image from a patient with partial epilepsy matched to itself after modification to simulate changes in the cerebral blood flow pattern and (c) ictal/interictal SPECT images from 15 patients with partial epilepsy. Blinded visual ranking and localization of the subtraction images derived from the patient images were also performed. RESULTS: Both voxel-based registration methods were more accurate than SM registration (P < 0.0005). Automated image registration algorithm was more accurate than mutual information correlation for the computer-simulated ictal/interictal images and the patient ictal/interictal studies (P < 0.05). The subtraction SPECTs from SM were poorer in visual ranking more often than the voxel-based methods (P < 0.05). CONCLUSION: Voxel intensity-based registration algorithms provide significant improvement in ictal/interictal SPECT registration accuracy and result in a clinically detectable improvement in the subtraction SPECT images.

Algorithms↗

Sensory motor cortex: correlation of presurgical mapping with functional MR imaging and invasive cortical mapping.

PURPOSE: To describe a clinically useful application of functional magnetic resonance (MR) imaging--presurgical mapping of the sensory motor cortex--and to validate the results with established physiologic techniques. MATERIALS AND METHODS: Functional MR mapping of the sensory motor cortex was performed in two women, aged 24 and 38 years. Both had intractable, simple partial motor seizures due to tumors located in or near the sensory motor cortex. They subsequently underwent invasive cortical mapping--direct cortical stimulation and/or sensory-evoked-potential recording--to localize the affected sensory motor area prior to tumor resection. RESULTS: In both patients, the functional MR study demonstrated task activation of the sensory motor cortex. In both cases, results of cortical functional mapping with invasive techniques matched those obtained with functional MR imaging. CONCLUSION: Presurgical mapping of the sensory motor cortex is a potentially useful clinical application of functional MR imaging.

Adult↗

Imaging of cerebral activation at 1.5 T: optimizing a technique for conventional hardware.

PURPOSE: To empirically optimize a two-dimensional magnetic resonance (MR) imaging technique for detecting changes in signal intensity during cerebral activation with a standard clinical imager. MATERIALS AND METHODS: Visual activation experiments were performed while imaging parameters were manipulated in a serial fashion, to test their effect on the percentage change in signal intensity (PCSI). The parameters tested were section thickness, echo time (TE), field of view (FOV), flip angle, radio-frequency (RF) spoiling, number of readout points, and number of signals averaged. RESULTS: The PCSI for visual activation experiments was typically in the 1%-5% range. The best results were achieved with a small section thickness, long TE, and large FOV. Variations in other acquisition parameters had a negligible influence on the PCSI. CONCLUSION: Good results can be obtained at functional MR imaging with standard 1.5-T hardware. Markedly improved results can be obtained by optimizing several key variables, namely, section thickness, TE, and FOV.

Adult↗

A software system for interactive and quantitative visualization of multidimensional biomedical images.

A comprehensive software system called ANALYZE has been developed which permits detailed investigation and evaluation of 3-D biomedical images. The software can be used with any 2-D or 3-D imaging modality, including x-ray computed tomography, radionuclide emission tomography, ultrasound tomography, magnetic resonance imaging and both light and electron microscopy. The package is unique in its synergistic integration of fully interactive modules for direct display, manipulation and measurement of multidimensional image data. Several original algorithms are included which improve image display efficiency and quality. One of the most versatile and powerful algorithms is interactive volume rendering, which is optimized to be fast without compromising image quality. An important advantage of this technique is to display 3-D images directly from the original data and to provide on-the-fly combinations of selected image transformations and/or volume set operations (union, intersection, difference, etc.). The inclusion of a variety of interactive editing and quantitative mensuration tools significantly extends the usefulness of the software. Any curvilinear path or region-of-interest can be manually specified and/or automatically segmented for numerical determination and statistical analyses of distances, areas, volumes, shapes, densities and textures. ANALYZE is written entirely in "C" and runs on several standard UNIX workstations. It is being used in a variety of applications by over 40 institutions around the world, and has been licensed by Mayo to several imaging companies. The software architecture permits systematic enhancements and upgrades which has fostered development of a readily expandable package. ANALYZE comprises a powerful "visualization workshop" for rapid prototyping of specific application packages, including applications to interactive surgery simulation and radiation treatment planning. ANALYZE offers the potential to accurately and reproducibly examine, from images, the structure and function of any cell, tissue, limb, organ or organ system of the body, much like a surgeon or pathologist might do in real life, but entirely non-invasively, without pain or destruction of tissue. These capabilities promise exciting new insights into the basic processes of life, and major advances in health care delivery through improved diagnosis and treatment of disease.

Computer Graphics↗

Uptake by cells of nucleic acids promoted by compounds sharing the pleiotropic effects of poly(ethylene glycol).

Poly(ethylene glycol) (PEG) is a member of a group of membrane active compounds that have pleiotropic effects on cells, eg, promotion of cell fusion, induction of erythroleukemia cell differentiation, and protection of cells from freezing damage. Since PEG has recently been shown to be an efficient promoter of genetic transformation in bacteria, yeast, and mammalian cells, studies were carried out to determine whether other PEG-related compounds could also promote genetic transformation. In this study, 24 compounds, which behave like PEG in other biological systems, are shown to promote transfection of human cells with isolated poliovirus RNA. That PEG and other commercially important compounds promote transfection indicates that such compounds may represent a biohazard to man.

Drug Synergism↗

High-efficiency polyethylene glycol-mediated transformation of mammalian cells.

A new, high-efficiency method for transformation of mammalian cells with nucleic acids is described which yields 10(5)-10(6) plaques/micrograms poliovirus infectious RNA (iRNA). The optimized procedure consists of two steps: (1) exposure of cells to iRNA in a high ionic-strength buffer followed by (2) a brief exposure to a 35% polyethylene glycol (PEG) solution. Optimized conditions for each variable in the procedure are described. Under optimized conditions for PEG-mediated transformation with RNA, large numbers of transformants are recovered with plasmid DNA as well. The procedure presented is similar to other high-efficiency PEG-mediated methods previously described for the genetic transformation of both nonprotoplasted Escherichia coli and yeast.

Animals↗

A workstation for multi-dimensional display and analysis of biomedical images.

The capability to extract objective and quantitatively accurate information from 3-D radiographic biomedical images has not kept pace with the capabilities to produce the images themselves. This is rather an ironic paradox, since on the one hand the new 3-D and 4-D imaging capabilities promise significant potential for providing greater specificity and sensitivity (i.e. precise objective discrimination and accurate quantitative measurement of body tissue characteristics and function) in clinical diagnostic and basic investigative imaging procedures than ever possible before, but on the other hand, the momentous advances in computer and associated electronic imaging technology which have made these 3-D imaging capabilities possible have not been concomitantly developed for full exploitation of these capabilities. Therefore, we have developed a powerful new microcomputer-based system which permits detailed investigations and evaluation of 3-D and 4-D (dynamic 3-D) biomedical images. The system comprises a special workstation to which all the information in a large 3-D image data base is accessible for rapid display, manipulation, and measurement. The system provides important capabilities for simultaneously representing and analyzing both structural and functional data and their relationships in various organs of the body. This paper provides a detailed description of this system, as well as some of the rationale, background, theoretical concepts, and practical considerations related to system implementation.

Computer Systems↗

Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis.

A comprehensive software package, called ANALYZE, has been developed (1) which permits detailed investigation and evaluation of multidimensional biomedical images. ANALYZE can be used with 3-D imaging modalities based on x-ray computed tomography, radionuclide emission tomography, ultrasound tomography, and magnetic resonance imaging. The software is written entirely in "C" and runs on standard UNIX workstations. The ANALYZE package features integrated, complimentary tools for fully interactive display, manipulation and measurement of multidimensional image data. The software architecture permits systematic enhancements and upgrades which has fostered development of a readily expandable package. It provides an effective shell for custom software prototyping and turnkey applications. This paper provides a general description of this software as well as specific details on the methodology employed to develop it, both conceptual and technical. Applications of the software are illustrated.

Image Processing, Computer-Assisted↗