Investigating intrinsic myocardial mechanics: the role of MR tagging, velocity phase mapping, and diffusion imaging.

Assessment of myocardial mechanics is an integral part of understanding and predicting heart disease. This review covers the two most common magnetic resonance (MR) methods used to measure myocardial motion: myocardial tagging and myocardial velocity mapping. Myocardial tagging has been well established in clinical research, despite its time-consuming postprocessing procedure. Myocardial velocity mapping uses the phase shifts of the spins to encode the velocity into the MR signal. This means that once the myocardial contours have been segmented, the data can be automatically processed to obtain quantitative measurements. Diffusion MR also has found applications in cardiac imaging, with preliminary results of myocardial fiber architecture being obtained recently. These three different MR techniques have provided valuable insights into the assessment of intrinsic cardiac mechanics. J. Magn. Reson. Imaging 2000;12:873-883.

Animals↗

The cardiovascular magnetic resonance machine: hardware and software requirements.

The flexibility of cardiac magnetic resonance imaging (MRI) includes faster imaging for applications such as stress tests, ventricular function, myocardial perfusion and coronary artery imaging. Faster imaging makes greater demands on the hardware and software. Although some cardiac imaging can be performed at 0.5 T, some of the faster techniques demand the higher signal-to-noise ratio of higher main field, and fat suppression in cardiac images is more easily achieved at higher field. Main field inhomogeneity affects rapid imaging and performance in open-access magnets. High gradient performance, low eddy currents and surface receiver coils are essential for fast cardiac imaging and the hardware of these systems including interventional imaging is discussed. The use of ECG signals for prospective and retrospective cardiac synchronization of MRI is examined. Techniques for reducing the major problem of respiratory motion in MRI are surveyed. Flexibility in the computer architecture of the scanner and the electronics generating the pulse sequence and controlling data acquisition is vital in cardiac imaging, for retrospective cardiac gating, respiratory navigator-controlled imaging and "real-time interactive" imaging in a similar manner to ultrasound imaging. Automated measurements from MR images remain under development. The pulse sequences and image display functions a cardiovascular MRI system should support for basic cardiac imaging applications and current clinical research areas are summarized.

Cardiovascular System↗

Transient streamlines: texture synthesis for in vivo flow visualisation.

Magnetic resonance (MR) imaging is a versatile technique for providing detailed information on blood vessel morphology and function. With its ability to acquire multi-dimensional cine flow data, MR is also an important tool for providing insight into blood flow patterns in vivo. The purpose of this paper is to describe the application of texture synthesis for flow visualisation. Two related issues are addressed, one is the removal of image noise from the acquired velocity data to ensure a correct representation of the underlying flow structure, and the other is the formation of transient streamlines through flow texture synthesis. The process of noise removal is achieved by using a convex projection algorithm based on the principle of mass conservation, whereas transient streamlines are formed via an iterative orientated pattern formation and enhancement procedure. The method described provides realistic visualisation of the flow patterns and avoids distortions caused by integration errors associated with conventional streamline tracking techniques. Effectiveness of the method applied to MR flow data acquired in healthy volunteers and patients is demonstrated.

Blood Flow Velocity↗

Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography.

In this Phase I clinical study, a novel ultrasmall superparamagnetic iron oxide contrast agent, NC100150 Injection (Nycomed Imaging, Oslo, Norway, a part of Nycomed Amersham), was used in two-dimensional magnetic resonance coronary angiography (MRCA). Safety and imaging data were acquired from 18 healthy male volunteers at both 0.5 and 1.5 T, before and after the administration of NC100150 Injection. Through-plane and in-plane images of the right coronary artery were analyzed. The postcontrast imaging sequences used prepulses and a high flip angle, to introduce T1 weighting. At 1.5 T (TE 2.6 msec), the through-plane coronary artery signal-to-noise ratio (SNR) (P = 0.04), coronary artery-to-fat signal difference-to-noise ratio (SDNR) (P = 0.001), coronary artery-to-myocardium SDNR (P<0.001), and coronary artery delineation (P<0.001) were improved by the administration of NC100150 Injection. For in-plane imaging, coronary artery delineation improved, but there were no significant changes in the SNR and SDNR. At 0.5 T, with the longer TE (6.7 msec) imaging sequence used, there was a reduction in the SNR (P = 0.01), the fat SDNR (through-plane P = 0.02; in-plane P = 0.25), and the coronary artery diameter (P<0.01 in both imaging planes). There was a trend toward improvement in the myocardial SDNR and coronary artery delineation. In conclusion, NC 100150 Injection was given safely to 18 healthy subjects, with no major adverse reactions. Coronary artery delineation was improved in both imaging planes at 1.5 T, with a trend toward improvement at 0.5 T. At 1.5 T, with a short TE imaging sequence, the marked T1 shortening effects of NC100150 Injection were dominant, leading to an improvement in the quantitative parameters for the through-plane images. At 0.5 T, with a longer TE imaging sequence, the T2* effects of the contrast agent played a role in reducing the quantitative image parameters. With further optimization of imaging sequences, to take advantage of the long-lived intravascular T1 shortening effect of NC100150 Injection, further improvements in MRCA will be possible.

Adult↗

Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography.

Real-time navigator echo (NE)-gated magnetic resonance coronary angiography (MRCA) during free respiration is now possible. However, the mean diaphragm end-expiratory position (DEEP) drifts over time, and this results in a reduction in scanning efficiency and increased artifacts due to the acquisition of data during periods of high diaphragm velocity. To address these problems, a diaphragm monitoring program that follows the mean DEEP over time has been developed. Fifteen subjects with ischemic heart disease underwent continuous NE monitoring of their diaphragm for 30 minutes. Using these diaphragm traces, theoretical MRCA scans were performed. Several diaphragm monitoring algorithms were developed and compared with the simplest case (a stationary 5 mm NE acceptance window placed around the mean DEEP, as measured by NE monitoring at the outset of the scan). An overall scan efficiency was calculated, and the number of completed scans where the mean DEEP lay within the NE acceptance window was recorded. Of the six algorithms considered, the most effective one monitored the mean DEEP and prospectively placed the upper limit of the NE acceptance window on this position for the subsequent acquisition. Using this algorithm in comparison with the simplest stationary scenario, both scan efficiency (47.9% vs. 38.5%, P = 0.01) and the number of completed scans where the mean DEEP lay within the NE acceptance window (71.2 vs. 30.3, P < 0.001) were improved. The implementation of such a monitoring algorithm, in combination with adaptive motion correction techniques, should improve overall scan efficiency while maintaining the end-expiratory position at the top end of the NE acceptance window, to reduce image artifacts.

Adult↗

Differences between normal subjects and patients with coronary artery disease for three different MR coronary angiography respiratory suppression techniques.

A comparison between three magnetic resonance coronary angiography (MRCA) respiratory motion suppression techniques was performed for both normal subjects and patients with coronary artery disease (CAD). MRCA images were acquired in 17 normal subjects and 15 patients with CAD, using conventional breath-hold MRCA, navigator echo (NE)-guided breath-hold MRCA (LED feedback), and NE-gated MRCA during free respiration. Image quality, diaphragm registration, and total acquisition time were assessed. Overall, there was poor diaphragm registration for conventional breath-holding compared with free respiration (P < 0.001). CAD patients found it significantly more difficult to perform a steady breath-hold (P = 0.04) or attain the same diaphragm position over multiple breath-holds than normal subjects (P = 0.02). All normal subjects, but only 3 of the 15 CAD patients, were able to perform the LED feedback technique (P < 0.001). For normal subjects, image quality was similar between the three respiratory suppression techniques (P = 0.3), while for CAD patients there was an improvement in image quality, for images acquired during free respiration (breath-hold vs. free respiration, P < 0.01). There was no significant difference in the total acquisition times between the breath-hold and free respiration techniques (P = 0.2). There were substantial differences in the effectiveness of MRCA respiratory suppression techniques between normal subjects and CAD patients. In patients, only NE-gated MRCA performed well, requiring minimal cooperation with no increase in total acquisition time. Validation of NE-MRCA techniques should always be performed in patients, as well as normal subjects, to ensure correct evaluation of the technique for the target population.

Adult↗

First-pass myocardial perfusion imaging and equilibrium signal changes using the intravascular contrast agent NC100150 injection.

In this phase I clinical study, the new ultrasmall superparamagnetic iron oxide contrast agent, NC100150 Injection (Nycomed AS, Oslo, Norway, a part of Nycomed Amersham), was assessed for first-pass magnetic resonance myocardial perfusion studies and its ability to produce equilibrium signal changes, as a possible indicator of myocardial blood volume. Data were acquired in 18 healthy male volunteers at 0.5 T and 1.5 T. At both field strengths, first-pass studies using T1-weighted sequences were acquired. Long TE spin-echo echoplanar imaging (EPI) was used at 0.5 T and short TE fast low-angle shot (FLASH) imaging at 1.5 T. With both sequences, T1 effects dominated the images for low doses, and time intensity curves potentially suitable for perfusion analysis were generated. At higher doses, T2 and T2* effects were observed. At 1.5 T, these predominantly affected the blood pool signal; however, at 0.5 T the myocardial signal was also involved, reflecting the relative T2 and T2* sensitivity of the spin-echo EPI sequence as a result of the long TE and long readout window, respectively. Equilibrium changes were assessed at both field strengths using T1-weighted FLASH sequences and in addition at 1.5 T using T2*-weighted gradient-echo EPI. With the T1-weighted images at both field strengths, signal changes were observed in all subjects; however, no dose-response relationship could be shown. With the T2*-weighted EPI there was significantly lower signal (P < 0.05) with the 3 and 4 mg/kg doses than with the 2 mg/kg dose. In conclusion, NC100150 Injection is useful for first-pass myocardial perfusion using T1-weighted sequences; however, low doses in combination with short TE sequences are required to minimize sensitivity to T2* effects. Equilibrium signal changes can also be induced in the myocardium. More work is required to optimize the imaging sequences and dose of NC100150 Injection for first-pass studies and also to determine whether the equilibrium signal changes can be used to measure myocardial blood volume changes in ischemic heart disease.

Adult↗

Locally focused 3D coronary imaging using volume-selective RF excitation.

This paper describes a locally focused magnetic resonance (MR) imaging method for three-dimensional (3D) zonal echoplanar coronary angiography using volume-selective radiofrequency (RF) excitation. Spatially variable resolution was used for delineating coronary arteries and reducing the effect of residual signals caused by the imperfect excitation profile of the RF pulse. The use of variable resolution enabled the derivation of basis functions having different spatial characteristics pertaining to regional object details, and a significantly smaller number of phase-encoded signal measurements was needed for image reconstruction. Based on the relative significance of each required phase-encoding step, real-time phase-encode reordering was used to minimize the effect of respiratory motion during coronary imaging. To eliminate Nyquist ghosting in oblique echoplanar imaging, the echoplanar data acquired during forward and reverse echoes were reconstructed separately and then averaged with spatial registration for improving the signal-to-noise ratio. The technique was evaluated with phantom experiments and right coronary artery images of 11 asymptomatic volunteers using a 0.5 T MR system. A marked improvement in image quality has been achieved despite a 30% reduction in imaging time.

Artifacts↗

Coronary artery imaging in a 0.5-Tesla scanner: implementation of real-time, navigator echo-controlled segmented k-space FLASH and interleaved-spiral sequences.

Coronary angiography techniques have been implemented on a 0.5-Tesla scanner with a view to performing coronary artery imaging. Slice-followed, segmented k-space FLASH sequences and interleaved-spiral sequences have been employed with acquisitions under real-time navigator echo control with patient feed back, enabling poor signal-to-noise levels to be overcome by averaging data acquired over multiple, variable-length, reproducible breath holds. Good-quality, millimetre-resolution coronary images were obtained in ten normal subjects with both techniques. The mean percent of data segments or interleaves acquired with the navigator echo within the 5-mm diaphragm acceptance window was 57% [standard deviation (S.D.), 11%; range, 38-85%], and the average image-acquisition times were 123+/-22 sec and 71+/-14 sec for segmented FLASH and interleaved-spiral imaging, respectively. In addition to shorter acquisition times, the interleaved-spiral sequence has superior temporal resolution, allowing the acquisition of limited, multislice data sets. However, the sequence is particularly sensitive to the off-resonance effects of residual epicardial fat surrounding the artery and to field nonuniformities, both of which lead to image blurring and, unlike segmented FLASH acquisitions (which are very robust), the spiral data sets generally require postprocessing.

Adult↗

3D coronary artery imaging with phase reordering for improved scan efficiency.

Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies phase encode reordering to 3D acquisitions, allowing larger navigator acceptance windows to be used, with a consequent reduction in acquisition time. This method is compared with navigator acceptance window methods (the acceptance-rejection algorithm and the diminishing variance algorithm) and the retrospective respiratory gating technique, both in vitro and in vivo. The use of phase reordering with a 10 mm acceptance window provided a significant increase in scan efficiency over a non-reordered 5 mm method (P<0.001) with no significant change in image quality, and a significant increase in image quality compared with a non-reordered image acquired in the same time (P<0.05). A significant improvement in both image quality and scan efficiency was demonstrated over the retrospective respiratory gating method (P<0.05).

Adult↗

Flow distortion and signal loss in spiral imaging.

The effect of in-plane motion on the point spread function (velocity PSF) in spiral imaging is studied experimentally and derived mathematically and is shown to consist of a smoothed, trailing edge and fringes around the leading edge. The velocity PSF remains largely in phase with the static PSF, consistent with the absence of signal loss by motion-related phase shifts in central k space. However, single-shot spiral imaging gives no clear improvement in complex and turbulent flow signal uniformity compared with echo-planar imaging with early, central k-space acquisition, which requires explanation given the spiral's earlier coverage of central k space. Alternate leading-edge fringes of the spiral's velocity PSF are in antiphase to the source, and cancellation may occur when these overlap other in-phase signals. Phase variations toward peripheral k space in turbulent flow also cause distortion. It is concluded that spiral imaging may lose complex and turbulent flow signals because of complex PSF distortion.

Algorithms↗

Motion-selective encoding for fast cine imaging.

In magnetic resonance (MR) cine imaging applications, it is common that only a fraction of the field of view is used for delineating dynamic features whereas surrounding static structures are merely served as landmarks for three-dimensional orientation. This paper presents a method of using motion-selective encoding for fast cine imaging. By the use of a simple RF saturation pulse, the imaging field of view was divided into two areas, one with motion and the other without. This allowed the static material to be imaged by fast ungated acquisition and dynamic structures by reduced phase encoding. Issues related to phase error correction were addressed and the proposed algorithm was validated using images acquired from five normal subjects. The saving in imaging time was dependent on the size of the moving structures and a 35% reduction in imaging time did not cause visually noticeable changes in image quality. The application of the technique is limited to cine images with large surrounding static structures and a theoretical analysis of maximum savings in imaging time in relation to the size of the moving structures within the image field of view is provided. Magn Reson Med 42:430-435, 1999.

Adult↗

Use of the intravascular contrast agent NC100150 injection in spin-echo and gradient-echo imaging of the heart.

This is the first study of the intravascular iron oxide particle contrast agent, NC100150 Injection (Nycomed Imaging AS, Oslo, Norway, a part of Nycomed Amersham) in magnetic resonance imaging of the human heart. Eighteen healthy male volunteers were studied at both 0.5 and 1.5 T before and after the administration of NC100150 Injection. Transaxial spin-echo images were acquired at both field strengths, conventional gradient-echo cine images at 0.5 T, and breathhold Turbo-FLASH cine images at 1.5 T. Optimized cine imaging sequences were used postcontrast, with a high flip angle of 60-70 degrees. In the spin-echo images there was a significant reduction in the blood pool flow artifact at the level of the right atrium (0.5 T, 57%, p < 0.01; 1.5 T, 41%, p = 0.01) and the left ventricle (LV) (0.5 T, 45%, p = 0.01; 1.5 T, 45%, p < 0.01). In the conventional gradient-echo cines at 0.5 T, there was a significant increase in the LV blood pool and myocardial signal difference-to-noise ratio (SDNR) in the diastolic (56%, p = 0.01) and systolic (141%, p < 0.001) frames. There was also a significant increase in the signal intensity (SI) gradient at the LV blood pool-myocardial border in the diastolic and systolic frames (both p < 0.001). At higher doses of NC100150 Injection (3 and 4 mg/kg), a rim of signal void around the LV blood pool was observed, perfectly defining the LV blood pool-myocardial border. In the Turbo-FLASH breathhold cines at 1.5 T, there was a significant increase in the LV blood pool-myocardial SDNR in the diastolic (221%, p < 0.001) and systolic (916%, p < 0.001) frames. Again, there was also a significant increase in the SI gradient at the LV blood pool-myocardial border in the diastolic and systolic frames (both p = 0.003). In conclusion, NC100150 Injection was given safely to 18 healthy subjects. Image quality and LV blood pool-myocardial definition were improved after the administration of NC100150 Injection. These improvements enable better spin-echo anatomical definition, better definition of myocardial wall motion, and should improve the capability of automated edge detection algorithms.

Adult↗

Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography.

There has been conflicting data in the literature regarding the use of wide navigator echo (NE) acceptance windows in combination with adaptive motion correction for magnetic resonance coronary angiography (MRCA). This in part may be due to the use of a fixed correction factor when applying the adaptive motion-correction algorithm, which may potentially result in miscorrection of the imaging slice in subjects whose correction factor differs widely from the mean. We have addressed this issue by measuring the superior/inferior correction factor in 25 subjects and assessing the effect of using a subject-specific correction factor (CFss) for MRCA in comparison with no adaptive motion correction (CF0) and erroneous adaptive motion correction with a correction factor of 1.0 (CF1). There was a wide variation in the correction factor between subjects (proximal right coronary artery, 0.49 +/- 0.15, range 0.20-0.70; proximal left coronary artery, mean 0.59 +/- 0.15, range 0.20-0.85). The subject-specific correction factor was accurately calculated from motion of the aortic root in the coronal plane between expiratory and inspiratory breathhold (correction factor calculated from coronal image versus correction factor calculated after localization of coronary arteries, r = 0.92, p < 0.001). MRCA image quality was improved using a subject-specific correction factor, for both a 6-mm NE acceptance window (CFss versus CF0, p = 0.008; CFss versus CF1, p = 0.02) and a 16-mm NE window (CFss versus CF0, p = 0.01; CFss versus CF1, p = 0.007). Furthermore, image quality was maintained between the two NE windows if the subjects-specific correction factor was used (6 versus 16 mm, p = 0.21), with an improvement in scan efficiency (6 versus 16 mm, 49 +/- 17% versus 81 +/- 22% respectively, p < 0.001). Thus, for adaptive motion correction to be implemented, a subject-specific correction factor should be used and calculated from simple coronal expiratory and inspiratory breathholds. For real-time NE-gated cardiac MR with adaptive motion correction, the NE window can be widened to reduce the acquisition period without loss of image quality.

Adult↗

FID-based lung MRI at 0.5 T: theoretical considerations and practical implications.

Pulse sequences based on FID signals and projection reconstruction (PR) were investigated for lung MRI at 0.5 T and evaluated for artifacts caused by: (1) k-space mismapping due to either delay or distortion of the readout gradient waveform, (2) cardiac motion and pulsatile flow, and (3) respiratory motion. Nonstructured artifacts were described, simulated, and experimentally confirmed for the first time. Nonstructured artifacts did not impair the demonstration of structures of high signal-to-noise ratio (SNR) but generated quantitative errors in the image intensity analysis over the lung parenchyma. The use of FID-based PR techniques for lung MRI is not justified at 0.5 T.

Artifacts↗

Three-dimensional coronary MR angiography using zonal echo planar imaging.

Using an adapted two-dimensional spatially selective RF excitation scheme, a novel yet practical three-dimensional (3D) zonal echo-planar imaging technique for MR coronary angiography has been developed. The robustness of the technique compared with the two-dimensional (2D) segmented fast low angle shot (FLASH) method was evaluated using the right coronary artery images of 16 asymptomatic volunteers with a 0.5-T mobile scanner. Each 3D acquisition required multiple breath-holds, and real-time navigator echoes were used to ensure consistent breath-holding. Advantages of the technique include an improved signal-to-noise ratio, clearer depiction of tortuous coronary vessels due to decreased partial volume effects, and reduced motion blurring by the use of a short echo-planar readout.

Adult↗

Motion and deformation tracking for short-axis echo-planar myocardial perfusion imaging.

The assessment of regional myocardial perfusion during the first-pass of a contrast agent bolus requires tracking of the signal time course for each myocardial segment so that a detailed perfusion map can be derived. To obtain such a map in practice, however, is not trivial because deformation of the shape of the myocardium and respiratory-induced motion render a major difficulty in this process. This study describes an automated approach for motion and deformation tracking of functional myocardial perfusion images. The effectiveness of the described method has been evaluated using a numerical phantom and results are compared with those from existing techniques which use deformable models. Preliminary results from applying our approach to 20 patients are discussed and compared with those from SPECT studies.

Aged↗

Non-breath-hold lung magnetic resonance imaging with real-time navigation.

Magnetic resonance imaging (MRI) with navigating techniques based on consecutive breath-holds demand a level of respiratory control that is often beyond the capability of patients with lung disease. The objectives of this investigation were to develop and evaluate a navigating technique for lung MRI that does not rely on patient cooperation. Navigating techniques were implemented at 0.5 T using conventional imaging techniques of short echo-time and imaging during normal breathing in the diastolic phase of the cardiac cycle. A column of spins, orthogonal to the diaphragm, was excited both immediately before and after the imaging segment. These signals were processed in real time to provide the position of the lung-diaphragm interface. An imaging segment was considered correctly acquired only when the interface position was within the acceptance window both before and after the acquisition of the segment. A distribution of lung-diaphragm interface positions obtained during normal respiration was employed to define the acceptance window. In the case of multislice techniques, the position of the lung-diaphragm interface immediately before the imaging segment was also employed to decide which phase-encoding step to acquire next, therefore reducing the apparent frequency of the respiratory motion. A distribution of interface positions, updated in real time, served as a reference for the allocation of phase-encoding steps according to diaphragm position. The lung images obtained represent a significant advance in image quality, improving further the ability of MR to detect and monitor pulmonary disease. Motion artifacts were reduced, and images reliably demonstrated smaller vessels, which are not normally visible without navigation.

Computer Systems↗