Three-dimensional spectroscopic imaging with time-varying gradients.

A spectroscopic imaging sequence with a time-varying readout gradient in the slice selection direction is used to image multiple contiguous slices. For a given voxel size, the imaging time and signal-to-noise ratio of the three-dimensional spectroscopic sequence are the same as for a single slice acquisition without the oscillating readout gradient. The data reconstruction employs a gridding algorithm in two dimensions to interpolate the nonuniformly sampled data onto a Cartesian grid, and a fast Fourier transform in four dimensions: three spatial dimensions and the spectral dimension. The method is demonstrated by in vivo imaging of NAA in human brain at 1.5 T with 10 slices of 16 x 16 pixels spectroscopic images acquired in a total scan time of 17 min.

Algorithms↗

Magnetic resonance fluoroscopy using spirals with variable sampling densities.

The imaging of dynamic processes in the body is of considerable interest in interventional examinations as well as kinematic studies, and spiral imaging is a fast magnetic resonance imaging technique ideally suited for such fluoroscopic applications. In this manuscript, magnetic resonance fluoroscopy pulse sequences in which interleaved spirals are used to continuously acquire data and reconstruct one movie frame for each repetition time interval are implemented. For many applications, not all of k-space needs to be updated each frame, and nonuniform k-space sampling can be used to exploit this rapid imaging strategy by allowing variable update rates for different spatial frequencies. Using the appropriate reconstruction algorithm, the temporal updating rate for each spatial frequency is effectively proportional to the corresponding k-space sampling density. Results from a motion phantom as well as in in vivo gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA) bolus tracking studies in a rat model demonstrate the high temporal resolution achievable using these techniques as well as the tradeoffs available with nonuniform sampling densities. This paper focuses on the acquisition of real-time dynamic information, and all images presented are reconstructed retrospectively. The issues of real-time data reconstruction and display are not addressed.

Animals↗

Spiral imaging on a small-bore system at 4.7T.

Spiral imaging has a number of advantages for ultrafast data acquisition. However, implementation on high-field small-bore systems requires carefully addressing the issues of inhomogeneity-induced blurring and gradient hardware constraints. In this paper, spiral imaging on a 40-cm-bore 4.7T CSI Omega System (Bruker Instruments) is discussed. A constant-voltage gradient waveform design algorithm is developed to reduce readout times as well as minimize waveform distortions due to gradient amplifier nonlinearities. Residual errors are then measured and taken into account in the image reconstruction procedure. Multiple spiral interleaves as well as a multifrequency reconstruction algorithm are used to decrease blurring of off-resonance spins. Both phantom and in vivo images demonstrate the performance of the resulting pulse sequences.

Adipose Tissue↗

Incorporating lactate/lipid discrimination into a spectroscopic imaging sequence.

A spectroscopic imaging sequence incorporating a two-shot lactate editing method was used in two human brain studies to image lactate and NAA. The subtractive editing method allows separate images of lactate, NAA, and lipids to be collected during a single study with no SNR penalty. The sequence uses a spectral-spatial excitation for slice selection and water suppression, and employs inversion recovery and an echo time of 136 ms for additional lipid suppression.

Aspartic Acid↗

Magnetic resonance spectroscopic imaging of ethanol in the human brain: a feasibility study.

The in vivo distribution of ethanol in normal human brain following the consumption of a moderate amount of alcohol was measured using magnetic resonance spectroscopic imaging. Three subjects were studied, and the spatial distribution of brain ethanol, 60-min postingestion and measured at a spatial resolution of 1.5 cm, was found to be highly nonuniform with the relative ethanol signal in cerebral spinal fluid, gray matter, and white matter determined to be 1.00, 0.72, and 0.37, respectively. These spectroscopic imaging results indicate that whereas in vivo magnetic resonance studies of ethanol are feasible, quantitative studies of alcohol need to account carefully for the various tissue types within the observed volume.

Alcoholic Intoxication↗

Lipid-suppressed single- and multisection proton spectroscopic imaging of the human brain.

Spectroscopic images of the brain have great potential in disease diagnosis and treatment monitoring. Unfortunately, interfering lipid signals from subcutaneous fat and poor water suppression due to magnetic field inhomogeneities can make such images difficult to obtain. A pulse sequence that uses inversion recovery for lipid suppression and a spectral-spatial refocusing pulse for water suppression is introduced. In contrast to methods that eliminate fat signal by restricting the excited volume to lie completely within the brain, inversion-recovery techniques allow imaging of an entire section without such restrictions. In addition, the spectral-spatial pulse was designed to provide water suppression insensitive to a reasonable range of B0 and B1 inhomogeneities. Several data processing algorithms have also been developed and used in conjunction with the new pulse sequence to produce metabolite maps covering large volumes of the human brain. Images from single- and multisection studies demonstrate the performance of these techniques.

Brain↗

A model for detecting early metabolic changes in neonatal asphyxia by 1H-MRS.

In newborn rabbits, the early cerebral metabolic changes caused by hypoxic-ischemic (H-I) insult was examined by using volume localized 1H-MRS (STEAM). Partial ischemia was caused by unilateral carotid artery ligation, and hypoxia was induced by 10% oxygen inspiration for 150 minutes. Lactate immediately increased after hypoxia induction and almost disappeared 120 to 150 minutes after removal of hypoxia in both H-I and hypoxia-only experiments. Lactate production correlated well with decrease of the blood oxygen saturation. More lactate was produced on ischemic side 50 minutes post-hypoxia induction in H-I study. Ischemia alone did not cause any significant lactate production. Lactate caused by hypoxia can be dynamically monitored by localized 1H-MRS. Existence of regional ischemia can induce greater anaerobic glycolysis and may affect the pattern of brain injury under hypoxia. 1H-MRS is a sensitive tool to detect the acute metabolic change caused by H-I insult.

Animals↗