Search PubMed⌕ Search

Biomedical subjects

D L Rollins

Publications and source records attributed to D L Rollins.

At least 37 records · Page 2Linked to original sources

Improved defibrillation threshold with a new epicardial carbon electrode compared with a standard epicardial titanium patch.

BACKGROUND: Recent studies show that depending on the type of shock morphology used, 5% to 15% of patients requiring implantable defibrillators cannot be treated with a nonthoracotomy system. In these cases, an epicardial patch-based system becomes necessary. In this study, we investigated a newly developed epicardial carbon electrode as an alternative to a standard epicardial titanium patch. METHODS AND RESULTS: A tubular epicardial braided carbon electrode of 7F diameter and 14-cm length applied in a U-shape to the epicardium was compared with a standard left ventricular epicardial 15-cm2 titanium mesh patch (CPI Inc). As cathode, a CPI endocardial lead, a Medtronic lead, or a carbon-platinum-iridium prototype electrode was used. Ventricular fibrillation was induced with a 60-Hz generator and allowed to continue for 10 seconds before a shock was given. Two different biphasic shock waveforms (3.2/2- and 6/6-millisecond) were delivered by the six electrode configurations. Eight dogs (weight, 24.5 +/- 1.3 kg) underwent an up-down defibrillation protocol. The order of testing the epicardial electrodes, the endocardial cathodes, and the waveform was randomized. With the epicardial carbon electrode, the mean defibrillation threshold (DFT) energy decreased 39% to 56% and the voltage decreased 24% to 35% compared with the titanium patch: from 8.3 +/- 2.5 to 4.9 +/- 3.6 J with the CPI lead and the 3.2/2-millisecond waveform, from 6.2 +/- 2.5 to 2.9 +/- 2.1 J with the carbon-platinum-iridium prototype, and from 6.4 +/- 3.4 J to 3.5 +/- 2.6 J with the Medtronic lead (P < or = .05). The DFT determinations with the 6/6-millisecond biphasic waveform showed a similar trend with slightly higher values. CONCLUSIONS: Compared with a titanium patch, the new braided epicardial electrode significantly decreases the defibrillation energy requirements. This effect can be maximized by using an endocardial carbon-platinum-iridium prototype as cathode and a short duration biphasic waveform.

Animals↗

Influence of malpositioned transvenous leads on defibrillation efficacy with and without a subcutaneous array electrode.

Some patients cannot receive a transvenous lead system because of high defibrillation thresholds (DFTs). We hypothesized that a right ventricular (RV) catheter electrode not extending as far as possible into the RV apex could cause high DFTs. Recently, a subcutaneous array (SQA) electrode has been shown to lower DFTs substantially. We compared the influence of a malpositioned RV catheter electrode on defibrillation efficacy for endocardial lead systems with and without a SQA. In eight anesthetized pigs, defibrillation catheters were placed in the RV apex and near the junction of the superior vena cava (SVC) and right atrium. SQA, formed by three elements, each 20 cm in length, was placed in the left thorax. DFTs were determined for a biphasic waveform using an up/down protocol with the RV catheter at the apex and with it repositioned 1-cm and 2-cm proximal to the apex. The mean DFT energies for the configurations with a SQA were less than those without a SQA for every catheter position. The placement of the RV catheter away from the apex caused an increase in defibrillation energy for the configurations without a SQA (apex: 17.1 +/- 3.8 J [mean +/- SD]; 1 cm: 20.1 +/- 4.6 J; 2 cm: 27.6 +/- 9.5 J; P < 0.05), but not for the configurations with a SQA (apex: 12.2 +/- 2.2 J; 1 cm: 12.3 +/- 2.9 J; 2 cm: 12.1 +/- 0.9 J: P = NS). These results suggest that a malpositioned RV catheter electrode, at the time of implantation or by late dislodgment, significantly elevates DFTs for a total endocardial system but not for a system that includes a SQA.

Animals↗

Responses of the transmembrane potential of myocardial cells during a shock.

INTRODUCTION: The purpose of this investigation was to study the transmembrane potential changes (delta Vm) during extracellular electrical field stimulation. METHODS AND RESULTS: Vm was recorded in seven guinea pig papillary muscles in a tissue bath by a double-barrel microelectrode with one barrel in and the other just outside a cell while shocks were given across the bath. The short distance (15 to 30 microns) between the two microelectrode tips and alignment of the tips parallel to the shock electrodes eliminated the shock artifact. Following ten S1 stimuli, an S2 shock field created by a 10-msec square wave was delivered during the action potential plateau or during diastole through shock electrodes 1 cm on either side of the tissue. Four shock strengths creating field strengths of 1.7 +/- 0.1, 2.9 +/- 0.2, 6.1 +/- 0.6, and 8.8 +/- 0.9 V/cm were given for the same impalement. Both shock polarities were given at each shock strength. For shocks delivered during the action potential plateau, the magnitudes of the peak delta Vm caused by the above four potential gradients were 21.1 +/- 8.2, 33.6 +/- 13.6, 49.9 +/- 24.2, and 52.3 +/- 28.0 mV (P < 0.05 among the four groups) for the shocks causing depolarization and 37.9 +/- 14.2, 56.6 +/- 16.4, 83.1 +/- 19.4, and 92.9 +/- 29.1 mV (P < 0.05 among the four groups) for the shocks causing hyperpolarization. Though delta Vm increased as potential gradients increased, the relationship was not linear. The magnitude of hyperpolarization was 1.9 +/- 0.5 times that of depolarization when the shock polarity was reversed (P < 0.05). As potential gradients increased from 1.7 +/- 0.1 to 8.8 +/- 0.9 V/cm, the time constant of the membrane response decreased significantly from 3.5 +/- 1.8 to 1.6 +/- 0.7 msec for depolarizing shocks and from 6.0 +/- 3.1 to 3.4 +/- 1.9 msec for hyperpolarizing shocks (P < 0.01 vs depolarizing shocks). For shocks delivered during diastole, hyperpolarizing shocks induced triphasic changes in Vm during the shock, i.e., initial hyperpolarization, than depolarization, followed again by hyperpolarization. CONCLUSION: During the action potential plateau, the membrane response cannot be represented by a classic passive RC membrane model. During diastole, activation upstrokes occur even during hyperpolarization caused by shocks creating potential gradients between approximately 2 and 9 V/cm.

Animals↗

Alteration of ventricular fibrillation by propranolol and isoproterenol detected by epicardial mapping with 506 electrodes.

INTRODUCTION: We hypothesized that drugs which alter ventricular refractoriness or excitability produce quantifiable changes in ventricular fibrillation. METHODS AND RESULTS: We used a 528-channel mapping system to quantify the effects of the beta-antagonist, propranolol, and the beta-agonist, isoproterenol, on activation patterns in ventricular fibrillation. A plaque of 506 (22 x 23) electrodes spaced 1.12 mm apart and covering about 5% of the ventricular epicardium was sewn to the anterior right ventricle in 18 pigs (30 kg). Propranolol (0.25 to 0.4 mg/kg) increased the refractory period at a right ventricular epicardial site while isoproterenol (3 to 5 micrograms/min) shortened it. Ventricular fibrillation was induced by programmed stimulation, and unipolar electrograms were recorded from the 506 plaque electrodes for 2 seconds beginning 1, 15, and 30 seconds after the onset of fibrillation. Active epicardial recording sites were identified from the first derivative of the unipolar potentials (dV/dt) detected at each electrode. Then, neighboring active sites were grouped into activation fronts by computer analysis. In six pigs the effect of repeated inductions of ventricular fibrillation was assessed by comparing ventricular fibrillation after saline with a preceding control episode of fibrillation. Each activation front excited 40% +/- 46% of the mapped region before blocking. No changes were observed with saline and multiple inductions of fibrillation. In another six pigs, ventricular fibrillation after propranolol was compared with a preceding control episode of fibrillation. Ventricular fibrillation after propranolol exhibited a decreased activation rate per epicardial recording site and fewer activation fronts per second. There was no change in the amount of tissue excited by each activation front or the number of reentry cycles per activation front compared with control. In addition, there was no change in the maximum negative dV/dt detected per activation at an epicardial site. In six pigs ventricular fibrillation during isoproterenol was compared with control episodes of ventricular fibrillation before and 45 minutes after washout of the drug. The control episodes of fibrillation were not different from each other. Compared with control, ventricular fibrillation during isoproterenol exhibited an increased activation rate per epicardial site, an increased amount of tissue excited by each activation front, and an increased maximum negative dV/dt for each activation. There was no change in the number of activation fronts per second or the number of reentry cycles per activation front compared with control. CONCLUSION: Quantitative analysis revealed that propranolol and isoproterenol do not have symmetrically opposite effects on ventricular fibrillation. Propranolol decreased the number of activation fronts while isoproterenol increased the amount of tissue excited by each activation front. Thus, drugs that alter ventricular refractoriness or excitability alter ventricular fibrillation.

Animals↗

Regional capture of fibrillating ventricular myocardium. Evidence of an excitable gap.

Previous investigations have suggested that during ventricular fibrillation (VF) pacing stimuli are incapable of evoking propagated ventricular activations. To determine whether regional myocardial capture could be achieved during rapid pacing in VF, extracellular unipolar potentials were sampled (2 kHz) and recorded from 506 Ag-AgCl electrodes arranged in a rectangular grid (22 x 23, 1.12-mm spacing) embedded in a plaque overlying two pacing electrodes in the epicardium of the anterobasal right ventricle in pentobarbital-anesthetized pigs (25 to 30 kg, n = 6). During separate episodes of electrically induced VF, two bursts of 40 monophasic stimuli (10 mA, 2-millisecond duration) were asynchronously applied to the stimulating electrodes in either a bipolar, unipolar anodal, or unipolar cathodal mode. Evidence of regional capture was provided by (1) animating the first temporal derivative of the extracellular potentials, (2) analyzing inter-beat interval patterns, and (3) employing the Karhunen-Loeve decomposition method to quantify the repetitiveness of spatio-temporal patterns of activation. Regional capture of ventricular myocardium during VF was observed when pacing stimuli fell late in the local myocardial activation interval and when the pacing cycle length was 80% to 115% of the mean subplaque activation cycle length. When myocardial activations became phase locked to the pacing stimuli, repeatable spatiotemporal patterns of activation followed each stimulus. Poincaré sections at the plaque border revealed that during VF prior to pacing, interbeat intervals were irregular but were driven by pacing to stable fixed values at times corresponding to our qualitative declaration of regional capture. A similar correspondence was demonstrated between the time of capture, defined by direct observation of the activation patterns, and a rise in the power contained in the first two spatial modes of a Karhunen-Loeve decomposition. These data demonstrate that appropriately timed stimuli produce regional capture of fibrillating right ventricular myocardium in the pig and support the existence of an excitable gap during VF in this model.

Animals↗

Effective defibrillation in pigs using interleaved and common phase sequential biphasic shocks.

Previous studies have shown that low internal defibrillation thresholds (DFTs) can be attained by using two pairs of electrodes and combining biphasic shocks with sequential timing. The purpose of this two-part study was to test the defibrillation efficacy of two new shock sequences, an interleaved biphasic, and a common phase sequential biphasic, that utilized two pairs of electrodes and were developed from the concept of sequential biphasic shocks. In the first part, defibrillation catheters were placed in the right ventricle and the superior vena cava of six anesthetized pigs. A small patch electrode was placed on the LV apex through a subxiphoid incision and a cutaneous patch was placed on the left thorax. The mean DFT energies for the interleaved biphasic (5.2 +/- 0.4 J) and the common phase sequential biphasic waveforms (5.4 +/- 0.4 J) were substantially less (P < 0.0001) than those for either the sequential monophasic (10.6 +/- 1.0 J) or single biphasic waveforms (9.0 +/- 1.0 J). In the second study, which used nine anesthetized pigs, the importance of phase reversal was demonstrated by the finding that the DFT energy of a common phase sequential biphasic shock (6.2 +/- 0.4 J) was much less than a common phase sequential monophasic shock (17.9 +/- 1.3 J, P < 0.0001); furthermore, the average DFT for four common phase sequential biphasic configurations (5.7 +/- 0.2 J) was much less than for a configuration that was similar except that current flow was not reversed in one phase so that no biphasic effect was present (19.7 +/- 1.2 J). The efficacy of common phase sequential biphasics was comparable to that of sequential biphasics. The effectiveness of sequential biphasics, interleaved biphasics, and common phase sequential biphasics is possibly due to two mechanisms: (A) an increase in the potential gradient during a later phase in regions that were low during the first phase, and (B) the exposure of most of the myocardium to a biphasic shock that reduces the minimum extracellular potential gradient needed to defibrillate.

Animals↗

Is the second phase of a biphasic defibrillation waveform the defibrillating phase?

Why some biphasic waveforms defibrillate with lower energies than monophasic waveforms of similar duration is unknown. One hypothesis is that the first phase of a biphasic waveform acts as a conditioning, hyperpolarizing prepulse to prepare for defibrillation by a second depolarizing phase. To test whether the second phase of a biphasic waveform is the defibrillating phase, three monophasic waveforms, an ascending ramp (A), a square wave (S), and a descending ramp (D), were compared to three biphasic waveforms with A, S, or D in the first phase (biphasic first phase) and three biphasic waveforms with A, S, or D in the second phase (biphasic second phase). Two defibrillation thresholds for each waveform were performed in 18 open chest pigs and mean defibrillation thresholds were compared. In nine pigs 16-msec monophasic and 16/16-msec biphasic waveforms were ranked by mean current and energy at defibrillation threshold. The ranks were the same for monophasic and biphasic second phase waveforms: for mean current A < S = D and for energy A < S < D. The ranks were different for the biphasic first phase waveforms: for mean current S < A = D and for energy S < A = D. Although ranks for the 16-msec monophasic waveforms matched those for the 16/16-msec biphasic second phase waveforms, the biphasic waveforms had higher mean currents and energies at defibrillation threshold. In nine pigs defibrillation thresholds for 6-msec monophasic and 6/6-msec biphasic waveforms were ranked. For mean current the ranks were monophasic: A < S = D; biphasic first phase: A = S = D; and biphasic second phase: S = D < A. For energy the ranks were monophasic: A = S < D; biphasic first phase: A = S = D; and biphasic second phase: S = D < A. Thus, ranks for the 6-msec monophasic waveforms differed from those for the 6/6-msec biphasic second phase waveforms. For 16/16-msec biphasic waveforms, less effective for defibrillation than corresponding 16-msec monophasic waveforms, these results support the hypothesis that the second phase of a biphasic waveform defibrillates since the defibrillation efficacy of a 16/16-msec biphasic waveform is related to the defibrillation efficacy of its second phase waveshape. However, for clinically useful 6/6-msec biphasic waveforms, more effective for defibrillation than 6-msec monophasic waveforms, the hypothesis is not supported because the ability of a 6/6-msec biphasic waveform to defibrillate is unrelated to the defibrillation efficacy of its second phase waveshape.

Animals↗

Effects of monophasic and biphasic shocks on action potentials during ventricular fibrillation in dogs.

This study determined the response of action potentials during ventricular fibrillation (VF) to timed monophasic and biphasic shocks. A floating glass microelectrode was used to record intracellularly from the anterior right ventricle in 10 open-chest dogs. After 10 seconds of electrically induced VF, 5-millisecond monophasic and 2.5/2.5-millisecond biphasic shocks or 16-millisecond monophasic and 8/8-millisecond biphasic shocks were given via mesh electrodes on either side of the microelectrode. Monophasic and biphasic truncated exponential shocks of 5 V/cm were given with coupling intervals timed from the beginning of a VF action potential to the shock ranging from 50 to 70 milliseconds in 5-millisecond increments. Each coupling interval for each waveform was tested during a different VF episode. The interval between successive activations during VF was 86 +/- 15 milliseconds (mean +/- SD). The refractory period during VF was 61 +/- 5 milliseconds for 5-millisecond monophasic shocks and 66 +/- 6 milliseconds for 2.5/2.5-millisecond biphasic shocks (P < .05). At each coupling interval, action potential duration at 50% repolarization (APD50) was significantly prolonged by the shocks compared with the mean preshock APD50 (P < .05). ADP50 duration increased significantly with increases in the coupling interval (P < .05) for both monophasic and biphasic waveforms. For all coupling intervals together, APD50 prolongation as a percent of the mean preshock APD50 was 170 +/- 55%, 192 +/- 45%, 151 +/- 44%, and 175 +/- 45% for 5- and 16-millisecond monophasic and 2.5/2.5- and 8/8-millisecond biphasic waveforms, respectively. This APD50 prolongation was greater for monophasic than biphasic shocks and was greater for longer than shorter waveforms (P < .05). Thus, during VF, (1) the refractory period for 5-V/cm truncated exponential waveforms lasting 5 milliseconds is approximately 75% of the VF activation interval; (2) the refractory period is shorter for monophasic than for comparable biphasic waveforms; (3) both monophasic and biphasic 5-V/cm shock fields cause prolongation of action potential duration; (4) prolongation of action potential duration increases as the coupling interval increases; and (5) prolongation of action potential duration is greater for monophasic shocks and for longer shock waveforms.

Action Potentials↗

High ligation of the greater saphenous vein for treatment of lower extremity varicosities: the fate of the vein and therapeutic results.

This study was carried out to determine the subsequent fate of the greater saphenous vein and the efficacy of its high ligation along with surgical excision or sclerotherapy of varicosities. From 1988 to 1990, 22 patients underwent high ligation and sclerotherapy, 22 underwent high ligation and varicose vein excision, and four underwent high ligation alone. There were 36 women and 12 men patients. The average patient age was 48. Sixty limbs were scanned by duplex ultrasound pre- and postoperatively to determine the status of the greater saphenous vein. Average follow-up time was 10 months. Patients and surgeons rated the results of therapy for ablation of varicosities and alleviation of symptoms. Surgical complications were evaluated. At postoperative scan, 47 greater saphenous veins (78%) were found to be completely patent, nine (15%) were thrombosed for a short segment (less than 10 cm) and four (7%) were more significantly thrombosed. Those limbs in which high ligation and sclerotherapy were performed had the highest complete patency rate (96%). Patient and surgeon satisfaction was good to excellent in every case. The only complications were three symptomatic greater saphenous vein thromboses. Although follow-up is relatively brief, complete patency of the ligated greater saphenous vein was found in most cases. High ligation allows preservation of a patent greater saphenous vein, which can be used as an arterial conduit at a later date and gives therapeutic results comparable to stripping without the additional morbidity.

Combined Modality Therapy↗

Defibrillation electrode configurations developed from cardiac mapping that combine biphasic shocks with sequential timing.

Previous canine mapping studies of the transvenous defibrillation lead configuration of right ventricle (RV) to left R2 patch (P) revealed regions of low potential gradient in the left ventricular apex (A) and the right ventricular outflow tract (O). Thus 16 new lead configurations were tested in eight dogs, which incorporated electrodes in A and O to raise the gradient. When used in conjunction with two sequential biphasic shocks, the average defibrillation threshold energy from these configurations was 57% lower than that produced by a single biphasic shock delivered through RV-->P (phase 1 cathode-->anode, p < 0.001). Of the 16 configurations tested, the most effective was RV-->P followed by A-->O. When the shocking order of this configuration was reversed in another eight dogs, no difference in defibrillation efficacy was noted. In individual configurations of RV-->P and A-->O that used a single biphasic shock, defibrillation was not effective. Finally, when two sequential biphasic shocks were delivered to the same two electrodes in seven other dogs, the defibrillation efficacy was low. Thus configurations that use two sequential biphasic shocks can produce low defibrillation thresholds when the shocks are delivered to two different sets of electrodes. The high efficacy may be caused by one shock increasing the potential gradient in regions of low potential gradient that are produced by the other shock.

Animals↗

High-current stimuli to the spared epicardium of a large infarct induce ventricular tachycardia.

BACKGROUND: Previous studies have demonstrated that both ventricular tachycardia (VT) and ventricular fibrillation (VF) may begin as figure-eight reentry: VT with a longer cycle length from spared tissue adjacent to an infarct by programmed stimulation and VF with a shorter cycle length from noninfarcted tissue by a large premature S2 stimulus. These results suggest that the type of tissue or cycle length of the arrhythmia rather than the mode of induction determines whether the figure eight becomes sustained VT or degenerates into VF. Thus, a protocol similar to that by which a VF threshold is determined may induce VT rather than VF when performed in the spared tissue over an infarct. METHODS AND RESULTS: In 10 dogs, 4 days after occlusion-reperfusion of the left anterior descending coronary artery, 10 S1 stimuli were delivered from a total of 34 right and left ventricular sites outside the infarct. An epicardial S2 stimulus over the infarct was increased in 10-mA steps and introduced in diastole at decreasing cycle lengths of 5 msec until VT or VF was induced. Sustained monomorphic figure-eight VT was induced from 24 S1 sites and VF from nine (p = 0.03). The mean cycle lengths for the initial six arrhythmic cycles was 152 +/- 33 msec for VT and 115 +/- 13 msec for VF (p less than 0.001). Mean transmural infarct extent was 80% in five dogs with only VT, 63% in three dogs with both VT and VF, and 15% in two dogs with only VF. Different morphologies of VT were induced by changing the S1 site, the S2 strength, or the S1S2 coupling interval. In 25 of the 34 arrhythmias, the central part of the initial figure-eight pathway was oriented opposite the S1 activation sequence in that region. CONCLUSIONS: A large S2 stimulus over a nontransmural infarct induces VT if the spared myocardium is thin. This study introduces a useful technique for inducing sustained monomorphic VT in which the location and direction of the figure-eight pathway are known a priori and in which different morphologies of sustained VT can be produced by changing the S1 site.

Animals↗

Existence of both fast and slow channel activity during the early stages of ventricular fibrillation.

Although sodium channels have been reported to be inactive after 5-10 minutes of ventricular fibrillation (VF), their state during early VF is unknown. In 12 open-chest dogs, a floating glass microelectrode was used to record intracellular action potentials from the right ventricle during pacing and during electrically induced VF. Before any drug was administered, an initial episode of VF was continuously recorded for at least 20 seconds followed by defibrillation. Recordings were made during VF episodes after superfusion for 15 minutes around the microelectrode site by low (2.8 x 10(-5) M) and high (10(-4) M) concentrations of tetrodotoxin (TTX) in five dogs, or by low (4 microM) and high (100 microM) concentrations of verapamil in another four dogs. In three dogs, VF was induced without drugs three times to determine if the effects observed in the previous dogs were caused by the drugs or by successive episodes of VF. Ten consecutive action potentials were analyzed at the onset and after 5, 10, 15, and 20 seconds of VF. Action potential amplitude and duration during paced rhythm or VF were not changed by the local perfusion of either TTX or verapamil. In the TTX group, the maximum upstroke rate of depolarization of an action potential (Vmax) during paced rhythm was 104 +/- 14 V/sec for control cycles before any drug was given, 86 +/- 15 V/sec for the low TTX concentration, and 55 +/- 14 V/sec for the high TTX concentration (p less than 0.05 versus other two). Vmax decreased from 55 +/- 32 V/sec at the beginning of VF to 37 +/- 27 V/sec after 20 seconds of VF for predrug VF, from 39 +/- 20 V/sec to 18 +/- 11 V/sec for low-dose TTX VF, and from 18 +/- 13 V/sec to 12 +/- 7 V/sec for high-dose TTX VF (p less than 0.05 among the three groups). In the dogs receiving verapamil, VF was still inducible with Vmax not significantly different from predrug VF at the onset and after 5 or 20 seconds of VF but with Vmax smaller (p less than 0.05) for verapamil than for predrug VF after 10 or 15 seconds of VF. In three dogs, Vmax was not significantly different during three successive episodes of VF when no drug was given between the episodes.(ABSTRACT TRUNCATED AT 400 WORDS)

Action Potentials↗

Prolongation of repolarization time by electric field stimulation with monophasic and biphasic shocks in open-chest dogs.

Recent studies suggest that 1) electrically induced fibrillation and defibrillation involve prolongation of refractoriness by the shock in addition to stimulation and 2) biphasic waveforms are more efficient for defibrillation than are comparable monophasic waveforms. The purpose of this study was to compare prolongation of action potential duration at 50% repolarization by monophasic and biphasic shocks during paced rhythm. A floating glass microelectrode was used to record intracellularly from the anterior right ventricular epicardium in seven open-chest dogs. After 10 S1 beats paced at an interval of 350 msec, 5-msec and 2.5-msec monophasic shocks and biphasic shocks, with each phase of 2.5 msec, were given via mesh electrodes on either side of the microelectrode. The shock strength was adjusted so that the shock field, measured from eight extracellular electrodes encircling the microelectrode, was about 5 V/cm. Monophasic and biphasic S2 shocks were given starting with an S1-S2 interval of 120 msec, which was increased in 5-msec steps until an action potential was produced by the S2 shock. Both monophasic and biphasic 5 V/cm shock fields caused significant prolongation of action potential duration. The prolongation of action potential duration increased as the S1-S2 interval increased. This prolongation occurred at shorter S1-S2 intervals for 5-msec monophasic shocks than for biphasic shocks.

Action Potentials↗

A comparative review of in situ versus reversed vein grafts in the 1980s.

In patients requiring an infrainguinal bypass who have an ipsilateral intact GSV, the choice between the reversed and in situ vein graft should be determined by the operative findings and the site of the distal anastomosis. When the ipsilateral GSV has either been removed or is of poor quality, ectopic autologous vein should be used in most circumstances and certainly for bypass to the infrapopliteal arteries. In reviewing the results of the two types of vein bypass to the popliteal artery, the results of two prospective, randomized studies and recent retrospective, nonrandomized reports suggest that there is no difference in patency rates between the two techniques. When performing a bypass to this level, the surgeon should not routinely use one method, but tailor the operative management to the individual patient. However, when the two bypass procedures to the infrapopliteal arteries were compared, the results of a prospective, randomized study and recent retrospective, nonrandomized reports furnish strong evidence that ISVGs provide better long term patency rates than RVGs. These results favoring use of distal ISVGs in nonrandomized reports are even more impressive, since the in situ technique was often preferentially chosen over the reversed vein method when only small diameter GSVs were available and when the bypass was performed to the distal tibial or pedal arteries. Many vascular surgeons agree with the conclusion that the ISVG is the bypass of choice for infrapopliteal bypass when an intact GSV is available. Although both the in situ and reversed vein techniques provide excellent long term patency rates for infrainguinal bypasses, and the vascular surgeon should be able to adapt this technique and approach for the individual patient, further randomized, prospective studies with extensive follow-up evaluation and a large number of patients are necessary to definitively resolve which technique provides optimal patency rates for arterial reconstruction of the lower extremity.

Anastomosis, Surgical↗

Strength-duration and probability of success curves for defibrillation with biphasic waveforms.

Certain biphasic waveforms require less energy to defibrillate than do monophasic pulses of equal duration, although the mechanisms of this increased effectiveness remain unclear. This study used strength-duration and percent success curves for defibrillation with monophasic and biphasic truncated exponential waveforms to explore these mechanisms. In part 1, defibrillation thresholds were determined for both high- and low-tilt waveforms. The monophasic pulses tested ranged in duration from 1.0 to 20.0 msec, and the biphasic waveforms had first phases of either 3.5 or 7.0 msec and second phases ranging from 1.0 to 20.0 msec. In part 2, defibrillation percent success curves were constructed for 6.0 msec/6.0 msec biphasic waveforms with a constant phase-one amplitude and with phase-two amplitudes of approximately 21%, 62%, 94%, and 141% of phase one. This study shows that if the first phase of a biphasic waveform is held constant and the second phase is increased in either duration or amplitude, defibrillation efficacy first improves, then declines, and then again improves. For pulse durations of at least 14 msec, the second-phase defibrillation threshold voltage of a high-tilt biphasic waveform is higher than that of a monophasic pulse equal in duration to the biphasic second phase (p less than 0.05), indicating that the previously proposed hypothesis of stimulation by the second phase is not the sole mechanism of biphasic defibrillation. These facts indicate the importance of the degree of tilt for the defibrillation efficacy of biphasic waveforms and suggest at least two mechanisms exist for defibrillation with these waveforms, one that is more effective for smaller second phases and another that becomes more effective as the second phase is increased.

Animals↗

Conduction disturbances caused by high current density electric fields.

During internal defibrillation, potential gradients greater than 100 V/cm occur near defibrillation electrodes. Such strong fields may cause deleterious effects, including arrhythmias. This study determined 1) the effects of such strong fields on the propagation of activation and 2) whether these effects were different for monophasic and biphasic shocks. Voltages and potential gradients during the shock, as well as activation sequences before and after the shock, were mapped from 117 epicardial electrodes placed over a 3 x 3-cm area on the right ventricle in six dogs. Pacing at a cycle length of 350 msec was given from a long narrow electrode on the right side of the mapped area to generate parallel activation isochrones. A monophasic shock, 10 msec in duration, or a biphasic shock with both phases 5 msec in duration was delivered 300 msec after the last paced stimulus via a mesh electrode on the left side of the mapped area as the cathode, with the anode on the right atrium. Shocks of 70-850 V were given, and the potential gradient and current density at each recording electrode were calculated from the measured potentials and fiber orientation by using a finite element method. Pacing was resumed 200 msec after the shock, and activation sequences were mapped for up to 5 minutes. Potential gradients ranged from 1 to 189 V/cm with high fields on the left side and low fields on the right side of the mapped area. Where the potential gradient was weak, the first activation sequence after the shock was similar to that before the shock, but activation blocked without conducting into areas where the gradient was greater than 64 +/- 4 (mean +/- SD) V/cm for monophasic and greater than 71 +/- 6 V/cm for biphasic shocks. These values are significantly different (p less than 0.003). The higher the potential gradient, the longer was the duration of block before conduction returned. Block duration, however, was generally shorter for biphasic than for monophasic waveforms of the same field strength. In conclusion, conduction block can follow either waveform, but biphasic waveforms cause less block than monophasic waveforms. This effect may partially explain the increased defibrillation efficacy of biphasic shocks.

Animals↗

Comparison of the internal defibrillation thresholds for monophasic and double and single capacitor biphasic waveforms.

Implantable cardiac defibrillators are now an accepted form of therapy for patients with life-threatening ventricular arrhythmias that cannot be controlled by antiarrhythmic drugs. These devices could be made even more acceptable if they were smaller, had increased longevity and the surgical procedure for implantation was less invasive. Reducing the energy requirements for internal defibrillation with use of a nonthoracotomy system would make all of these goals achievable. Monophasic and double and single capacitor biphasic waveforms were compared in 14 anesthetized dogs (25.5 +/- 2.2 kg) with use of a nonthoracotomy lead system that has previously been shown to distribute the delivered voltage throughout the heart more equally. Cathodal catheter electrodes were placed in the right ventricular apex and outflow tract. The anodal electrode was a large cutaneous R2 patch placed over the left side of the chest. The mean energy requirement for defibrillation when a single capacitor biphasic waveform was used was significantly less (6.4 +/- 2.6 J) than that for either the double capacitor biphasic or the monophasic waveform (18.0 +/- 8.0 and 17.4 +/- 8.0 J, respectively) of the same duration. Unexpectedly, the leading edge voltage for the phase I of the single capacitor biphasic waveform was significantly less (266 +/- 51 V) than that for either the double capacitor biphasic or the monophasic waveform (336 +/- 76 and 427 +/- 117 V, respectively). In conclusion, in large dogs, defibrillation is possible at low energy levels with a single capacitor biphasic waveform.

Animals↗