Search PubMed⌕ Search

Biomedical subjects

D L King

Publications and source records attributed to D L King.

At least 37 records · Page 2Linked to original sources

A dotted line assimilates in visibility to a solid line.

This study tested the theory that a context-produced increase in visibility of a target is due to its assimilation in visibility to the context. A context + target and a context are discriminated better than are a target and background. This occurs for two different context + targets in which the context is a solid line and the target is a dotted line. But it does not occur when solid lines replace these dotted lines. The dotted lines are much less visible than the solid lines. Therefore, the dotted lines increase in similarity in visibility to the solid lines, which is assimilation, but for visibility, rather than for a typical part. Assimilation does not occur between perceptually equal parts. Consequently, the reason why the two context + targets with only solid lines do not result in increases in visibility may be that these lines are sufficiently equal in visibility that assimilation in visibility is precluded. So, the theory is supported. This theory is consistent with evidence that one group (phenomenal whole) is associated with both assimilation and an increase in visibility. Accordingly, a stimulus with a relatively large distance between its solid and dotted lines is apprehended as a relatively weak group, and does not result in an increase in visibility.

Adult↗

Discrimination learning decreases perceived similarity according to an objective measure.

UNLABELLED: Initial identification discriminations between two sizes and between two slants produced better overall performances on subsequent size and slant same-different discriminations, respectively. This size- and slant-specific transfer was due to an improvement on only the different pairs. Time-duration identification discriminations with the identical stimuli and response assignments improved neither overall same-different performances nor performances on different pairs. A good performance on different pairs relative to same pairs should indicate a low perceived similarity. The literature indicates that A-X and B-Y pairings produce a positive transfer on an A-versus-B discrimination when X and Y are relatively low in similarity, and also indicates that a low perceived (not physical) similarity improves discrimination learning. An increase in salience should have also improved performance on the same pairs. THE CONCLUSION: the initial discriminations decreased the perceived similarity of parts (size or slant). This decrease resembles perceptual contrast. A discrimination between two parts also seems to increase the extent to which each part is apprehended as a separate group. Therefore, the conclusion accords with the position that two groups are associated with contrast, including for visibility.

Adult↗

Immediately preceding stimuli increase the detection of a less detectable but not a more detectable stimulus.

Both a small (S) and a large (L) stimulus occurred individually and randomly over trials. The task was to make the same speeded response to either stimulus. LSSS sequences on trials N-3, N-2, N-1, and N, respectively, resulted in a faster RT to S on trial N than to S on trial N-2. However, SLLL sequences did not produce a corresponding increase in detection. Also, overall, S was less detectable than L. Suppose that the physical S on trial N was lower in detectability-memorability than a memorial S produced by S on the immediately preceding trials N-1 and N-2. If so, the physical S may have assimilated in detectability-memorability to the memorial S. explaining why its detectability increased. In contrast, the physical L may have been sufficiently high in detectability-memorability to preclude a comparable assimilation. The theory: assimilation underlies detectability, regardless of whether two components are both physical (previous research), or whether one is physical and the other is memorial (the present research).

Adult↗

Validation of three-dimensional echocardiography for quantifying the extent of dyssynergy in canine acute myocardial infarction: comparison with two-dimensional echocardiography.

OBJECTIVES: This study was designed to compare the accuracy of three- and two-dimensional echocardiography for quantifying the extent of abnormal wall motion in experimental acute myocardial infarction, as correlated with the pathologic determination of infarct size. BACKGROUND: Two-dimensional echocardiographic estimations of the fraction of myocardium showing abnormal wall motion are often used as an index of infarct size even though they rely on image plane positioning and geometric assumptions that may not be valid. Three-dimensional echocardiographic reconstruction of the endocardial surface eliminates the need for these assumptions and may improve echocardiographic estimates of infarct size. METHODS: Coronary ligation was performed in 14 open chest dogs, and echocardiographic imaging of the ventricle was performed 6 h later. Three-dimensional echocardiography used seven or eight spatially registered short-axis images to measure percent of endocardial surface and mass showing abnormal wall motion. Three two-dimensional echocardiographic methods using multiple, nonpatially registered images were evaluated. One method used seven or eight-axis slices and a summation of discs algorithm for computing surface area. The second method used the same images and a conical model for the left ventricle. The third used basal, middle and apical short-axis plus apical four- and two-chamber views comparing summed endocardial lengths showing abnormal wall motion with the total of the endocardial dimensions, expressed as percent. The percent of left ventricular mass and surface area infarcted was determined by staining with triphenyltetrazolium chloride. RESULTS: Three-dimensional echocardiographic measurements of endocardial surface and correlated more closely with infarct mass (r = 0.94, SEE +/- 3.6%) than did the two-dimensional method using the summation of discs algorithm (r = 0.85, SEE +/- 6.6%), he summation of conical sections algorithm (r = 0.82, SEE +/- 5.4%) or the method using summed endocardial lengths (r = 0.79, SEE +/- 7.4%). Limits of agreement analysis comparing mass showing abnormal wall motion with anatomic infarct mass surface area showing abnormal wall motion with anatomic infarct surface area showed the smallest limits for three-dimensional echocardiography. CONCLUSIONS: Three-dimensional echocardiography is a more accurate means of noninvasively estimating myocardial infarct size in this canine model than two-dimensional echocardiography.

Animals↗

Three-dimensional echocardiography compared to two-dimensional echocardiography for measurement of left ventricular mass anatomic validation in an open chest canine model.

A three-dimensional echocardiographic system has been developed that can accurately compute left ventricular mass in vitro. This study was designed to validate the new echocardiographic system for the measurement of left ventricular mass in vivo and to compare the accuracy of three-dimensional echocardiography to the accuracy of conventional two-dimensional echocardiography for measuring left ventricular mass. Echocardiographic imaging was performed 6 h following coronary ligation in 20 open chest dogs, at which time the heart was excised and the left ventricle weighed. Three-dimensional echocardiography used multiple short axis sections and polyhedral surface reconstruction to compute myocardial volume. The two dimensional methods employed the truncated ellipsoid model and the area-length model. Myocardial volume was multiplied by 1.05 g/cc and echocardiographic mass estimates were compared to the true left ventricular weight. Three-dimensional echocardiography provided the best correlation (r = 0.96, upsilon r = 0.88 and r = 0.83 for the truncated-ellipsoid and area-length methods, respectively), and the lowest standard error of the estimate for the regression equation (+/- 5.5 g upsilon +/- 11.0 and +/- 14.6 g, respectively). Three dimensional echocardiography also had the lowest standard deviation for the echo-true mass differences (+/- 5.8 g upsilon +/- 10.7 g and +/- 14.2 g) and a lower root mean square percent error (6.8%) upsilon 12.6% and 12.7%). In this open chest canine model, three-dimensional echocardiography is more accurate than standard two-dimensional echocardiographic methods for measuring left ventricular mass.

Animals↗

Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: comparison with cross sectional echocardiography and magnetic resonance imaging.

OBJECTIVE: To evaluate the accuracy of quantitative three dimensional echocardiography in patients with deformed left ventricles. DESIGN: Three dimensional and cross sectional echocardiographic estimates of left ventricular volume and ejection fraction were prospectively compared to those obtained from magnetic resonance imaging. SETTING: Echocardiography laboratory of a university hospital. PATIENTS: 26 patients (9 months to 42 years, median age 11 years) with pulmonary hypertension and fixed reversal of normal interventricular septal curvature. MAIN OUTCOME MEASURES: Left ventricular end diastolic and end systolic volumes and ejection fraction. RESULTS: Three dimensional echocardiographic comparison to magnetic resonance imaging (MRI) yielded r values of 0.94 and 0.87 with a bias of -6.9 (SD 6.9) ml and -16 (11.2) ml for systolic and diastolic volumes respectively. Inter-observer variability was minimal (8.3% and 7.6% respectively). Cross sectional echocardiography gave correlation coefficients of 0.62 and 0.80 and bias of 3.1 (14.1) ml and 16.3 (18.3) ml for systolic and diastolic volumes respectively. Ejection fraction by three dimensional echocardiography also had closer agreement with MRI (bias = 1.1 (7.7)%) than cross sectional echocardiography (bias = 4.4 (13.9)%). CONCLUSIONS: Three dimensional echocardiography provides reliable estimates of left ventricular volumes and ejection fraction, comparable to magnetic resonance imaging in pulmonary hypertension patients with compressed ventricular geometry. Because it eliminates the need for geometric assumptions it shows closer agreement with magnetic resonance imaging in that setting than cross sectional echocardiography.

Adolescent↗

Supernumerary and congenitally absent teeth: a literature review.

This review article examines supernumerary teeth as to prevalence, location, clinical and radiographic appearance, etiology, complications and management of supernumerary teeth; congenital absence of teeth as to prevalence and location, clinical features and complications, etiology, treatment considerations, and coexistance of supernumeraries and congenital absence of teeth.

Anodontia↗

Posterior crossbites in children.

Posterior crossbite, the most common malocclusion in young children, can be caused by a variety of skeletal, muscular, or dental factors. This condition produces insufficient maxillary arch width and is frequently associated with various oral sucking and postural habits. If left untreated, this problem can result in adverse skeletal growth changes. Various mechanical treatment modalities designed to expand the posterior maxillary arch width are available to correct this problem. The appropriate treatment method depends on the patient's age and level of cooperation as well as the determined etiology of the constriction.

Child↗

Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods.

BACKGROUND: Reliable, serial, noninvasive quantitative estimation of left ventricular ejection fraction is essential for selecting and timing therapeutic interventions in patients with heart disease. Equilibrium radionuclide angiography is widely used for this purpose but has well-recognized limitations. Advantages of echocardiography over equilibrium radionuclide angiography include assessment of wall motion, valvular pathology, and cardiac hemodynamics, in addition to portability, lack of radiation exposure, and substantially lower cost. However, conventional echocardiographic techniques are limited by geometric assumptions, image positioning errors, and use of subjective visual methods. To overcome these limitations, a three-dimensional echocardiographic method was developed. This study compares ejection fraction by three-dimensional echocardiography, quantitative two-dimensional echocardiography, and subjective two-dimensional echocardiographic visual estimation with that by equilibrium radionuclide angiography. METHODS AND RESULTS: Fifty-one unselected patients with suspected heart disease underwent left ventricular ejection fraction determination by equilibrium radionuclide angiography and three-dimensional echocardiography using an interactive line-of-intersection display and a new algorithm, ventricular surface reconstruction, for volume computation. In 44 patients, ejection fractions were also estimated visually by experienced observers from two-dimensional echocardiography and by quantitative two-dimensional echocardiography using an apical biplane summation-of-disks algorithm. An excellent correlation was obtained between three-dimensional echocardiography and equilibrium radionuclide angiography (r = .94 to .97, SEE = 3.64% to 5.35%; limits of agreement, 10.3% to 13.3%) without significant underestimation or overestimation. SEE values and limits of agreement were twofold to threefold lower than corresponding values for all two-dimensional echocardiographic techniques. In addition, interobserver variability was significantly lower for the three-dimensional echocardiographic method (10.2%) than for the apical biplane summation-of-disks method (26.1%) and subjective visual estimation (33.3%). CONCLUSIONS: Determination of ejection fraction by three-dimensional echocardiography yields results comparable to those obtained by equilibrium radionuclide angiography and is substantially superior to all two-dimensional echocardiographic methods. Therefore, three-dimensional echocardiography may be used for accurate serial quantification of left ventricular function as an alternative to equilibrium radionuclide angiography.

Adolescent↗

The association of assimilation and an increase in visibility in perceptual grouping.

Subjects performed a series of forced-choice discriminations to determine whether both group-assimilation and group-visibility associations could be obtained from nearly identical strong and weak group patterns. The discrimination between the context+target square and the context [symbol: see text] was better than between the target- and background, as was the case for --, whose context and target components were its left and right halves, but not for [symbol: see text]. Square and -- produced a better performance when their lines (halves) were the same in color, and a poorer performance when their lines were different in color, but [symbol: see text] produced the reverse. Likewise, only square and -- produced a better performance when closed, and a poorer performance when open. These context+target etc., same-different, and closure results argue that square and -- produced a greater increase in visibility of their component --, more assimilation among their parts, and a stronger group than did [symbol: see text]. This evidence of a group-assimilation-visibility association cannot be attributed to the fortuitous occurrence of an increase in visibility with one object, assimilation with a second, and closure with a third, unlike previous evidence. This association cannot be explained by feature-based theories. Therefore, a superordinate unit is the cause of this association.

Choice Behavior↗

One line decreases the visibility of a simultaneous identical distant second line.

A top line decreased the visibility of a simultaneous, identical, distant bottom line. This context-produced decrease in visibility (DV) occurred when the bottom line was masked by flanking lines and hence was less visible than the top line. It continued when the top line was three times as far from the bottom line. It disappeared without the mask. There was a hint of an opposing context-produced increase in visibility (IV) when the lines were close together. The DV is not accounted for by numerous extant phenomena and theories. It means that the top line decreased the similarity in visibility between it and the bottom line, a contrast effect for visibility, rather than for a typical attribute. Contrast does not occur between two attributes that are perceptually equal. Therefore, the reason why two distant equally visible objects fail to result in a DV may be that their equal visibility precludes the occurrence of contrast. This DV-as-contrast theory is consistent with evidence that two groups (phenomenal wholes) are associated with both contrast and DVs, and thus also with evidence that one group is associated with both assimilation and IVs.

Attention↗

Effect of slope variation and skating technique on velocity in cross-country skiing.

The purpose of the present study was to investigate the effect of slope variations upon the maximal velocity attainable by cross-country ski racers using three skating techniques (V-1, V-2, and Gunde). Nine (2 females, 7 males) junior ski racers (16.0 +/- 0.4 yr of age, mean +/- SEM) exhibiting strong technical skills participated in the study. The subjects were required to skate at maximal velocity over five different courses (length 120-200 m) with mean slopes of -1, 0, 6, 9, and 12%. Video analysis was used to determine skiing velocity, cycle length, and cycle rate. Heart rate was monitored to verify intensity of exertion. Results indicated that intensities were similar to those observed while racing. Velocities for the three techniques were not different for -1, 0, and 6% slopes. However V-1 was significantly faster (P < 0.01) at 9% and 12% inclines. Velocity was highly correlated to cycle length (P < 0.01) but unrelated to cycle rate. Cycle length was significantly different between techniques (P < 0.01) and varied across slopes. Cycle rate was significantly different between techniques (P < 0.01) but did not vary across slopes. Thus, our results indicate that any of the three techniques is adequate on flat and rolling terrain, but V-1 should be used at slopes of 9% and above. It is also concluded that during short trials skied at maximal velocity, skiing velocity is highly dependent on cycle length and independent of cycle rate.

Adolescent↗

Three-dimensional echocardiography: in vitro and in vivo validation of left ventricular mass and comparison with conventional echocardiographic methods.

OBJECTIVES: This study aimed to validate a method for mass computation in vitro and in vivo and to compare it with conventional methods. BACKGROUND: Conventional echocardiographic methods of determining left ventricular mass are limited by assumptions of ventricular geometry and image plane positioning. To improve accuracy, we developed a three-dimensional echocardiographic method that uses nonparallel, nonintersecting short-axis planes and a polyhedral surface reconstruction algorithm for mass computation. METHODS: Eleven fixed hearts were imaged by three-dimensional echocardiography, and mass was determined in vitro by multiplying the myocardial volume by the density of each heart and comparing it with the true mass. Mass at diastole and systole by three-dimensional echocardiography and magnetic resonance imaging (MRI) was compared in vivo in 15 normal subjects. Ten subjects also underwent imaging by one- and two-dimensional echocardiography, and mass was determined by Penn convention, area-length and truncated ellipsoid algorithms. RESULTS: In vitro results were r = 0.995, SEE 2.91 g, accuracy 3.47%. In vivo interobserver variability for systole and diastole was 16.7% to 27%, 14% to 18.1% and 6.3% to 12.8%, respectively, for one-, two- and three-dimensional echocardiography and was 7.5% for MRI at end-diastole. The latter two agreed closely with regard to diastolic mass (r = 0.895, SEE 11.1 g) and systolic mass (r = 0.926, SEE 9.2 g). These results were significantly better than correlations between MRI and the Penn convention (r = 0.725, SEE 25.6 g for diastole; r = 0.788, SEE 28.7 g for systole), area-length (r = 0.694, SEE 24.2 g for diastole; r = 0.717, SEE 28.2 g for systole) and truncated ellipsoid algorithms (r = 0.687, SEE 21.8 g for diastole; r = 0.710, SEE 24.5 g for systole). CONCLUSIONS: Image plane positioning guidance and elimination of geometric assumptions by three-dimensional echocardiography achieve high accuracy for left ventricular mass determination in vitro. It is associated with higher correlations and lower standard errors than conventional methods in vivo.

Adult↗

Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients.

OBJECTIVES: We compared two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. BACKGROUND: Three-dimensional echocardiography has been shown to be highly accurate and superior to two-dimensional echocardiography in measuring left ventricular volume in vitro. However, there has been little comparison of the two methods in patients. METHODS: Two- and three-dimensional echocardiography were performed in 35 patients (mean age 48 years) 1 to 3 h before left ventricular cineventriculography. Three-dimensional echocardiography used an acoustic spatial locator to register image position. Volume was computed using a polyhedral surface reconstruction algorithm based on multiple nonparallel, unevenly spaced short-axis cross sections. Two-dimensional echocardiography used the apical biplane summation of disks method. Single-plane cineventriculographic volumes were calculated using the summation of disks algorithm. The methods were compared by linear regression and a limits of agreement analysis. For the latter, systematic error was assessed by the mean of the differences (cineventriculography minus echocardiography), and the limits of agreement were defined as +/- 2 SD from the mean difference. RESULTS: Three-dimensional echocardiographic volumes demonstrated excellent correlation (end-diastole r = 0.97; end-systole r = 0.98) with cineventriculography. Standard errors of the estimate were approximately half of those of two-dimensional echocardiography (end-diastole +/- 11.0 ml vs. +/- 21.5 ml; end-systole +/- 10.2 ml vs. +/- 17.0 ml). By limits of agreement analysis the end-diastolic mean differences for two- and three-dimensional echocardiography were 21.1 and 12.9 ml, respectively. The limits of agreement (+/- 2 SD) were +/- 54.0 and +/- 24.8 ml, respectively. For end-systole, comparable improvement was obtained by three-dimensional echocardiography. Results for ejection fraction by the two methods were similar. CONCLUSIONS: Three-dimensional echocardiography correlates highly with cineventriculography for estimation of ventricular volumes in patients and has approximately half the variability of two-dimensional echocardiography for these measurements. On the basis of this study, three-dimensional echocardiography is the preferred echocardiographic technique for measurement of ventricular volume. Three-dimensional echocardiography is equivalent to two-dimensional echocardiography for measuring ejection fraction.

Adult↗