Snare removal of a telectronics accufix atrial J retention wire.

A voluntary recall of the Telectronics Accufix models 330-801 and 329-701 "J"-shaped atrial pacemaker leads has been issued because of fracture and extrusion of the J-shaped retention wire. Such extrusion can result in laceration of the atrium or surrounding vascular structures. Herein we describe a patient with a fractured and extruded retention wire that was snared and removed percutaneously; the atrial lead was left intact, and pacing function was satisfactory. This unique procedure can be used to avoid the morbidity associated with percutaneous lead extraction or thoracotomy and to prevent potential dislodgment and embolization of the retention wire during lead extraction.

Child↗

Long-term survival after permanent pacemaker implantation for sick sinus syndrome.

In this population-based study, long-term survival and prognostic factors were examined in 148 patients, 55 men and 93 women, from Olmsted County, Minnesota, who had permanent pacemaker implantation for sick sinus syndrome between 1969 and 1991. The overall survival for patients who had received a permanent pacemaker for sick sinus syndrome was significantly worse than that of an age- and sex-matched control population (p < 0.0001). The increased mortality was attributable at least in part to the presence of structural heart disease in patients with sick sinus syndrome who had undergone permanent pacemaker implantation (82 of 148 patients, 55%). Survival of patients with isolated sick sinus syndrome was comparable (p = 0.6729), whereas in patients with structural heart disease it was significantly worse than expected (p < 0.0001). Symptoms were eliminated or improved in 116 patients (78%) after pacemaker implantation. Multivariate analysis identified congestive heart failure, valvular heart disease, history of stroke or transient ischemic attack, and age as independent risk factors for mortality. However, there was a trend toward decreased survival in patients who had received ventricular pacing compared with those who had received dual-chamber pacing, but this difference did not reach statistical significance (p = 0.0556). The mode of pacing was not an independent risk factor (p = 0.23). The observed survival of patients aged < 80 years was significantly worse than expected (p < 0.0001), whereas that of patients aged > or = 80 years was similar to the expected (p = 0.22).

Adult↗

Long-term survival after pacemaker implantation for heart block in patients > or = 65 years.

Permanent pacing can prevent recurrent symptoms and reduce mortality in elderly patients with symptomatic high-degree atrioventricular (AV) block. However, long-term survival with respect to comparable control subjects has not been well defined. In our study, relative long-term survival and prognostic predictors after permanent pacemaker implantation for symptomatic high-degree AV block were assessed among all residents of Olmsted County, Minnesota, who were > or = 65 years old. Of the 154 patients, 77 were men and 77 were women (mean age 80 +/- 7 years). Follow-up was 0.1 to 19.8 years (mean 4.2 +/- 2.8). Sixty-nine patients had isolated AV block and 85 had coexisting heart disease. Observed survival at 1, 3, 5, and 10 years was 85%, 68%, 52%, 21%, and 72%, 50%, 31%, 11% for patients with isolated AV block and patients with coexisting heart disease, respectively (p = 0.006). Observed survival in patients 65 to 79 years old with isolated AV block was comparable to age- and sex-matched cohorts (p = 0.53), but in patients aged > or = 80 years, it was less than that for control subjects (p = 0.014). In patients with coexisting heart disease, observed survival was less than that for control subjects in patients 65 to 79 years old (p < 0.001) and > or = 80 years (p < 0.001). Multivariate analysis identified congestive heart failure, chronic obstructive pulmonary disease, age, syncope, insulin-dependent diabetes mellitus, and male gender as independent predictors of increased mortality.

Age Factors↗

Consistent subcutaneous prepectoral implantation of a new implantable cardioverter defibrillator.

OBJECTIVE: To describe the use of a new implantable cardioverter defibrillator (ICD) that can be placed in the prepectoral region rather than implanted in the abdominal wall. DESIGN: We report the experience of placement of this new ICD in the prepectoral region in 13 patients from Sept. 28, 1993, through Jan. 10, 1994, at the Mayo Clinic. MATERIAL AND METHODS: Thirteen consecutive patients offered this new ICD underwent placement of transvenous defibrillation leads, and the pulse generator was placed in a pocket formed in the subcutaneous, prepectoral space. Testing ensured a defibrillation threshold of 24 J or less. RESULTS: In all 13 patients, the pulse generator could be placed in the subcutaneous, prepectoral space. In all except one patient, acceptable defibrillation thresholds were achieved by using lead systems placed totally transvenously. Only one patient required placement of a subcutaneous patch. All but two patients were dismissed from the hospital within 3 days after the ICD implantation. CONCLUSION: Consistent subcutaneous, prepectoral placement of this new ICD pulse generator is possible. Because the entire procedure can be performed in the pacemaker implantation room, the potential exists for decreasing the duration of the hospitalization and associated costs.

Aged↗

Recent advances in cardiac pacing.

This article reviews recent studies, chapters, and review articles describing advances in cardiac pacing. Initially we discuss expanding and controversial pacing indications, including neurocardiogenic syncope and hypertrophic as well as dilated cardiomyopathies. Recent contributions to the understanding of factors influencing pacing mode selection are then discussed, including survival and atrial fibrillation in the various modes, the hemodynamic importance of atrioventricular synchrony and adaptive atrioventricular intervals, the importance of rate adaptation, the development of pacemaker syndrome, pacemaker response to the development of atrial arrhythmias, and special pacing modes such as VDD and AAIR. Finally, recent advances in rate-adaptive sensors and algorithms are reviewed, including preliminary results with dual sensors.

Bradycardia↗

Report of the NASPE Policy Conference training requirements for permanent pacemaker selection, implantation, and follow-up. North American Society of Pacing and Electrophysiology.

NASPE proposes and supports the concept of a two-tracked training system in cardiac pacing. Track I training will properly train physicians for the prescription of pacemakers and the monitoring of pacemaker patients, and track II training will properly prepare physicians for the implantation of pacemakers. Regardless of specialty (cardiologist or surgeon) or training venue (cardiac pacing fellowship, cardiac electrophysiology and pacing fellowship, sabbatical or mentor sponsored training), it is recommended that these minimum standards be required for hospital credentialing. NASPE also supports the voluntary institution by training program directors of core pacing training in cardiovascular disease and cardiac electrophysiology fellowships. This core training does not in itself constitute proper track I or II training for physicians interested in adequately prescribing, monitoring, or implanting cardiac pacemakers.

Cardiac Pacing, Artificial↗

Clinical surveillance of an active fixation, bipolar, polyurethane insulated pacing lead, Part II: The ventricular lead.

Since 1989, 72 Telectronics 330-201 active fixation, polyurethane insulated ventricular leads (Accufix) have been implanted at the Mayo Clinic. There were four (5.6%) acute lead related complications (perforation, microdislodgment, and macrodislodgment), three of which led to early reoperation. Over a follow-up time of up to 2.7 years (median 9.4 months), there were six (8.3%) chronic lead related complications but no failures of lead material. Most of these complications developed during the first month, and half of them were transient, with documented improvement later. Two patients (2.8%) required reoperation for chronic complications. At follow-up examination of the pacing thresholds, usually performed about 3 months after implantation, 14.3% of the examined patients had high pacing thresholds necessitating high-output programming. The mechanisms and later evolution of this phenomenon should be further evaluated.

Adult↗

Clinical surveillance of an active fixation, bipolar, polyurethane insulated pacing lead, Part I: The atrial lead.

Since 1989, 168 Telectronics model 330-801 active fixation, polyurethane insulated atrial leads (Accufix) have been implanted at the Mayo Clinic. There were four (2.4%) acute lead related complications, (i.e., perforation, microdislodgment, and pericarditis). Over a median follow-up time of 7.6 months (up to 2.7 years), there were 14 (8.3%) chronic complications, including 1 instance (0.6%) of definite lead failure. Most of these complications were early (within the first month) and transient. Four patients (2.4%) required reoperation for chronic complications. During follow-up, 23% of the examined patients had high pacing thresholds, most at about 3 months after implantation, necessitating high-output programming. The exact mechanism and natural history of this phenomenon should be further investigated.

Adolescent↗

Pacemaker malfunction.

The field of cardiac pacing has expanded rapidly in recent years. Engineering improvements and microprocessor technology have resulted in a vast increase in pacemaker technology. The "high-tech" edge of cardiac pacing often discourages all but the pacemaker specialist from approaching a malfunctioning pacemaker. Electrocardiographic signs of pacemaker malfunction can be grouped into four categories: failure to output, failure to capture, undersensing, and inappropriate pacemaker rate. For each of these categories, there may be true malfunctions and pseudomalfunctions. In addition, environmental sources of electromagnetic interference, both within and outside the hospital environment, can result in pacemaker malfunction. Approaching pacemaker malfunction with these categories in mind should help minimize confusion.

Electrocardiography↗

The Dotter retriever and pigtail catheter: efficacy in extraction of chronic transvenous pacemaker leads.

Several techniques exist for percutaneous extraction of chronic pacemaker leads. To establish the efficacy of the Dotter retriever and pigtail catheter, we reviewed the removal of 59 endocardial pacemaker leads in 42 patients (mean age 71 years). The mean duration of lead implantation was 44 months (range 1-169 months). Thirty-two leads were withdrawn with simple traction alone, and five leads were abandoned when traction failed. The remaining 22 leads were manipulated with a Dotter retriever or pigtail catheter, or both. Twelve leads were dislodged from the endocardium with simple traction (10) or with traction transmitted through an entwining pigtail catheter (2), but they could not be fully withdrawn. Eleven of these leads (92%) were then successfully extracted with the Dotter retriever. Seven of the remaining 10 leads were successfully dislodged and removed by the Dotter retriever. Overall, 9 of 12 leads (75%) that could not be dislodged from the endocardium with simple traction were removed with a Dotter retriever or pigtail catheter, or both. Three patients in whom no catheter method worked required thoracotomy for removal of infected leads. No complications resulted from use of the Dotter retriever or pigtail catheter. We conclude that the Dotter retriever and pigtail catheter have moderate efficacy for dislodging chronic endocardial leads. Once mobilized, however, the leads can be withdrawn with great success with the Dotter retriever. Newer technology should not result in the abandonment of this proven technique.

Adolescent↗

Venous complications after insertion of a transvenous pacemaker.

We reviewed the incidence, clinical features, current diagnostic evaluations, and treatments of venous complications that can occur after implantation of a transvenous pacemaker. Of the approximately 80 published articles on the potential venous complications after implantation of a permanent transvenous pacemaker, we selected 63 that addressed the clinical features, diagnosis, and treatment of pacemaker lead-induced venous thrombosis, which occurs in approximately 30 to 45% of patients early or late after implantation of a transvenous pacemaker. Most patients with chronic deep venous thrombosis remain asymptomatic because of the development of an adequate venous collateral circulation. Clinical features of pacemaker lead-induced deep venous thrombosis, although rare, are easily recognized. They should be sought routinely during follow-up of all patients with transvenous pacemaker leads because venous obstruction can interfere with intravenously administered therapy, monitoring of central venous pressure, and revision of a pacemaker lead. Acute deep venous thrombosis is likely to be symptomatic. Early recognition and treatment of acute deep venous thrombosis may help to decrease the potential morbidity and mortality. The definitive diagnosis of pacemaker lead-induced venous thrombosis necessitates contrast-enhanced or digital subtraction venography. Management includes anticoagulation, thrombolytic therapy, surgical intervention, and, recently, percutaneous transluminal balloon venoplasty and depends on the duration, extent, and site of venous occlusion as well as the accompanying symptoms.

Cardiac Pacing, Artificial↗

The next 5 years in cardiac pacemakers: a preview.

Advances in cardiac pacing continue at an astounding rate, and, occasionally, technologic capabilities are developed almost faster than they can be implemented clinically. The development and implementation of single- and dual-chamber rate-adaptive pacemakers have been the major thrusts in cardiac pacing in recent years. Rate-adaptive pacing will continue to be of primary interest in the future as investigators search for the perfect "sensor" and attempt to develop rate-adaptive pacemakers with multiple sensors. The "smart" pacemaker--that is, an autoprogramming, autodiagnostic device--will also be refined. The ultimate "smart" pacemaker would be capable of automatically adjusting output and sensing factors as well as altering the rate-adaptive variables and even changing the pacing mode in response to variations in the underlying rhythm. Other aspects of cardiac pacing that will be actively investigated include new low-threshold pacing lead designs, refinements of the single-lead pacing system capable of P-synchronous pacing, and diagnostic information that can be derived from sensors used for rate-adaptive pacing.

Cardiac Pacing, Artificial↗

Follow-up of a minute ventilation rate adaptive pacemaker.

Although rate adaptive pacemakers are now frequently prescribed, there is limited information regarding long-term follow-up of patients with a pacemaker capable of rate adaptation. We have examined our patients in whom a pacemaker capable of rate adaptation via a sensor that determines minute ventilation has been implanted. After following a group of 42 patients for a mean of 13.2 months we have found this to be a reliable rate adaptive pacing system. The sensor was reliable long term, the system is easy to program, and sensor settings were changed infrequently.

Aged↗

Evaluation of an in-line bipolar polyurethane ventricular pacing lead.

A study was undertaken to evaluate the performance of the Medtronic 4012 polyurethane in-line bipolar pacing electrode. One hundred twenty six patients implanted with the 4012 lead were followed by our clinic with 116 of these leads implanted at our institution. Patients were followed a minimum of every 4 months. Testing included the performance of stimulation thresholds, sensing thresholds, and provocative maneuvers to evaluate for myopotential inhibition testing a minimum of every eight months. There were 12 documented lead failures of the total 126 patients. Further analysis was limited to the ten failures occurring in the 116 leads implanted at our center. All ten failed leads utilized the suture anchoring sleeve. Six of the leads were left cephalic implants, three were right cephalic, and one was right subclavian. Manifestations of failure included: seven oversensing abnormalities, three undersensing, four loss of ventricular capture, one premature end of service, four lead impedance decreases to < 250 omega and some presentations in combination. No leads were explanted for evaluation. The Kaplan-Meier product limit method was used to estimate the time to lead failure. The probability of not experiencing a lead failure within the first 4 years of implant is estimated to be 0.9103 (SE = 0.0338). Pacemaker dependent patients implanted with the 4012 lead should be given special consideration for prophylactic replacement.

Actuarial Analysis↗