Evolving indications for permanent pacing.

Indications for permanent pacemakers have expanded in recent years. The American College of Cardiology (ACC) and American Heart Association (AHA) guidelines for implantation of cardiac pacemakers were recently updated and now include several of the newer indications. Greatest interest about newer applications of pacemaker therapy focuses on hypertrophic obstructive cardiomyopathy, dilated cardiomyopathy, and pacing for the prevention of atrial fibrillation. Pacing for neurocardiogenic syncope remains controversial despite emerging data. Pacing for long QT syndrome, pacing after cardiac transplantation, and pacing for hemodynamic improvement in the occasional patient with first-degree atrioventricular block and hemodynamic compromise also warrant attention. Available clinical data are discussed in the context of the recent ACC and AHA guidelines.

Arrhythmias, Cardiac↗

A stepwise testing protocol for modern implantable cardioverter-defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions.

Current use of newer implantable cardioverter-defibrillators (ICDs) has changed the spectrum of pacemaker-ICD interactions and provided new tools for testing and understanding those interactions. Testing for pacemaker-ICD interactions was performed in 31 procedures involving 22 patients. The protocol included: (1) evaluation of pacemaker stimulus artifact amplitude and its ratio to that of the evoked ventricular electrogram, (2) testing for inhibition of ventricular fibrillation (VF) detection by the ICD during asynchronous pacing at maximum output, (3) evaluation by pacemaker event marker recordings of pacemaker sensing behavior while programmed to nonasynchronous mode during ventricular tachycardia (VT) or VF, and (4) evaluation of postshock interactions. Inhibition of detection of VT/VF was found in 6 of 22 patients (27.2%). Large stimulus artifact amplitude (>2 mV) or stimulus artifact:evoked QRS ratio > 1/3 had a positive predictive accuracy of 18% and 14.4%, respectively, and a negative predictive accuracy of 100% and 92.3%, respectively, for clinically significant interaction. Asynchronous pacing occurred in 16 of 31 procedures (51.6%), and was due to underdetection by the pacemaker in 4 of 16 (25%) and noise reversion in 12 of 16 (75%). Postshock phenomena occurred in 6 cases, 3 of which were clinically significant. Overall, 11 of 22 patients (50%) had clinically significant interactions discovered by this protocol, which led to system revisions in 6 and to pacemaker output reprogramming in 5. Thus, pacemaker-ICD interactions are frequently detected using a thorough and systematic protocol. Most cases can be managed by system revision or pacemaker reprogramming.

Artifacts↗

Relation between mode of pacing and long-term survival in the very elderly.

OBJECTIVES: This study analyzes the relationship between pacing mode and long-term survival in a large group of very elderly patients (> or = 80 years old). BACKGROUND: The relationship between pacing mode and long-term survival is not clear. Because the number of very elderly who are candidates for pacing is increasing, issues related to pacemaker (PM) use in the elderly have important clinical and economic implications. METHODS: We retrospectively reviewed 432 patients (mean age, 84.5+/-3.9 years) who received their initial PM (ventricular in 310 and dual chamber in 122) between 1980 and 1992. Follow-up was complete (3.5+/-2.6 years). Observed survival was estimated by the Kaplan-Meier method. Age- and gender-matched cohorts from the Minnesota population were used for expected survival. Log-rank test and Cox regression hazard model were used for univariate and multivariate analyses. RESULTS: Patients with ventricular PMs appeared to have poor overall survival compared with those with dual-chamber PMs. Observed survival after PM implantation in high grade atrioventricular block (AVB) patients was significantly worse than expected survival of the age- and gender-matched population (p < 0.0001), whereas observed survival of patients with sinus node dysfunction was not significantly different from expected survival of the matched population (p = 0.413). By univariate analysis, ventricular pacing in patients with AVB appeared to be associated with poor survival compared with dual-chamber pacing (hazard ratio [HR] 2.08; 95% confidence interval [CI] 1.33 to 3.33). After multivariate analysis, this difference was no longer significant (HR 1.41; 95% CI 0.88 to 2.27). Independent predictors of all-cause mortality were number of comorbid illnesses, New York Heart Association functional class, left ventricular depression and older age at implant. Pacing mode was not an independent predictor of overall survival. Older age at implantation, diabetes mellitus, dementia, history of paroxysmal atrial fibrillation and earlier year of implantation were independent predictors of ventricular pacemaker selection. CONCLUSIONS: After PM implantation, long-term survival among very elderly patients was not affected by pacing mode after correction of baseline differences. Selection bias was present in pacing mode in the very elderly, with ventricular pacing selected for sicker and older patients, perhaps partly explaining the apparent "beneficial impact on survival" observed with dual-chamber pacing.

Aged↗

Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.

OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of pacemaker lead extraction with the excimer sheath in comparison to nonlaser lead extraction. BACKGROUND: Fibrotic attachments that develop between chronically implanted pacemaker leads and to the venous, valvular and cardiac structures are the major obstacles to safe and consistent lead extraction. Locking stylets and telescoping sheaths produce a technically demanding but effective technique of mechanically disrupting the fibrosis. However, ultraviolet excimer laser light dissolves instead of tearing the tissue attachments. METHODS: A randomized trial of lead extraction was conducted in 301 patients with 465 chronically implanted pacemaker leads. The laser group patients had the leads removed with identical tools as the nonlaser group with the exception that the inner telescoping sheath was replaced with the 12-F excimer laser sheath. Success for both groups was defined as complete lead removal with the randomized therapy without complications. RESULTS: Complete lead removal rate was 94% in the laser group and 64% in the nonlaser group (p = 0.001). Failed nonlaser extraction was completed with the laser tools 88% of the time. The mean time to achieve a successful lead extraction was significantly reduced for patients randomized to the laser tools, 10.1 +/- 11.5 min compared with 12.9 +/- 19.2 min for patients randomized to nonlaser techniques (p < 0.04). Potentially life-threatening complications occurred in none of the nonlaser and three of the laser patients, including one death (p = NS). CONCLUSIONS: Laser-assisted pacemaker lead extraction has significant clinical advantages over extraction without laser tools and is associated with significant risks.

Aged↗

The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators.

UNLABELLED: Bradycardia support by ICDs has been limited to fixed rate, ventricular pacing. Concomitant placement of a pacemaker and an ICD exposes a patient to potentially life-threatening device interactions. ICDs capable of dual chamber pacing have recently become available. The number of ICD recipients who stand to benefit from the addition of dual chamber pacing is debated, but no data have addressed this question. This retrospective study analyzed all patients who received nonthoractomy ICD system placement at the Mayo Clinic in Rochester, MN between March 1991 and October 1996 in order to determine the proportion of patients in whom a dual chamber pacing ICD may be indicated. DEFINITIONS: (1) Definitely indicated = pacemaker present at ICD implant or NASPE Class I pacing indication; (2) Probably indicated = NASPE Class II pacing indication, NYHA Functional Class III or IV, or history of systolic congestive heart failure; (3) Possibly indicated = history of paroxysmal atrial fibrillation or an ejection fraction < or = 20%. The results were that nonthoracotomy ICDs were placed in 253 patients. A dual chamber ICD would have been definitely indicated in 11% of the study group, probably indicated in 28%, and possibly indicated in 14%. Chronic atrial fibrillation was present at ICD implant in 6.7% of patients and developed in 0.9%/yr during follow-up. The addition of dual chamber pacing to ICDs stands to potentially benefit approximately half (53%) of ICD recipients. These data do not address all patients who may benefit from dual chamber sensing.

Adolescent↗

Clinical surveillance of a tined, bipolar, steroid-eluting, silicone-insulated ventricular pacing lead.

Since 1990, 1,068 Medtronic 5024 bipolar, silicone-insulated, tined, steroid-eluting ventricular leads have been implanted at the Mayo Clinic (Rochester, MN) and Midelfort Clinic (Eau Claire, WI). Implantation data were favorable: median pacing thresholds of 0.5 V at 0.5 ms, median R wave of 13.4 mV, and median impedance of 593 omega. Of the 2.1% acute lead-related complications (dislodgment, microdislocation, diaphragmatic pacing, and undersensing), 1.2% necessitated reoperation. This rate is lower than that in most published series of other leads. During a median follow-up of 23 months (up to 76 months), 12 (1.1%) chronic lead-related complications (high thresholds, loss of capture, and undersensing) and no instances of definite or suspected lead material failure occurred. This rate is much lower than that in studies of other leads. Thus, the 5024 lead combines the reliability of silicone insulation with a low rate of chronic complications that is probably the result of its steroid elution. No evidence of failure of lead material has appeared up to 6 years after implantation.

Adolescent↗

Clinical surveillance of a tined, bipolar, J-shaped, steroid-eluting, silicone-insulated atrial pacing lead.

Since 1990, 558 Medtronic 5524 bipolar, silicone-insulated, J-shaped, tined, steroid-eluting atrial leads have been implanted at the Mayo Clinic (Rochester, MN, USA) and the Midelfort Clinic (Eau Claire, WI, USA). Implantation data were favorable, with pacing thresholds at implantation (median threshold, 0.6 V) better than most published data on other atrial leads. The rate of acute lead-related complications (dislodgment and diaphragmatic pacing) necessitating reoperation or electrical abandonment of the atrial lead was 0.9%. This rate is lower than that in most published series of atrial leads. Over a median follow-up time of 17.5 months (up to 69 months), there were no chronic lead-related complications and no definite or suspected failures of lead material. This rate is much lower than that with other atrial leads studied previously. We conclude that the Medtronic 5524 atrial lead combines the reliability of silicone insulation with a lack of chronic complications and high thresholds due to its steroid elution and with stability in the atrium due to its J shape despite a passive fixation mechanism. There is no evidence of lead material failure during up to 6 years of follow-up.

Administration, Topical↗

Permanent pacing in patients with univentricular heart.

Patients with one of several varieties of malformation designated as "univentricular hearts" may be especially challenging when permanent pacing is required. Our objective was to review our experience in this subset of patients that had undergone permanent pacing and thus determine the optimal approach. A retrospective chart review was done of 32 patients with some variety of "univentricular" malformation who had required permanent pacing at our institution. Although technically challenging, permanent pacing in this group of patients can be successful through several approaches. The various approaches, as well as consideration of the differences that exist between patients undergoing septation and those undergoing a Fontan procedure are discussed. Although long-term permanent pacing is possible in this group of patients, before pacing begins, a thorough understanding of the anatomy and prior surgical procedures is necessary. Use of a combined atrial transvenous and ventricular epicardial pacing system may work well for some patients. With the development of newer and more reliable coronary sinus leads, dual chamber transvenous pacing with ventricular stimulation via the coronary sinus could become the approach of choice in some patients with "univentricular hearts."

Adolescent↗

Digoxin, hypercalcaemia, and cardiac conduction.

The cardiac effects of hypercalcaemia are usually manifest as a shortening of the QT-interval. Hypercalcaemia is infrequently associated with a clinically manifest arrhythmia. However, concomitant therapy with digoxin or underlying cardiac disease can potentiate the arrhythmogenic effects of hypercalcaemia, leading to a symptomatic rhythm disorder. We describe a symptomatic arrhythmia, which developed in a patient with hypercalcaemia secondary to squamous cell carcinoma of the bronchus. The patient was on digoxin therapy at the time. The arrhythmia did not recur after discontinuation of digoxin therapy and correction of the hypercalcaemia. Because of its effect on cardiac conduction, hypercalcaemia should be considered in the evaluation of any patient with an unexplained bradyarrhythmia. Conversely, patients with hypercalcaemia should discontinue digoxin therapy and be evaluated for the presence of rhythm disorders while receiving appropriate treatment for hypercalcaemia.

Aged↗

Evolving indications for permanent cardiac pacing: an appraisal of the 1998 American College of Cardiology/American Heart Association Guidelines.

Concise and complete guidelines of indications for permanent pacemakers are critical for the clinician involved in permanent pacing. A critical appraisal of the American College of Cardiology/American Heart Association 1998 guidelines on indications for permanent pacing clarifies inconsistencies and expands on information within the current guidelines.

Cardiac Pacing, Artificial↗

Importance of pacemaker noise reversion as a potential mechanism of pacemaker-ICD interactions.

Numerous types of interactions between pacemakers and implantable cardioverter defibrillators (ICDs) have been described. Pacemaker outputs preventing appropriate detection of ventricular tachycardia or ventricular fibrillation by the ICD is one of the more serious. Asynchronous pacemaker activity during ventricular arrhythmias may be caused by either nonsensing of the arrhythmia or by noise reversion, which is an algorithm that causes the pacemaker to switch to asynchronous pacing when repetitive sensing at a high rate occurs. We analyzed the mechanisms underlying asynchronous pacemaker activity in ventricular arrhythmias using pacemaker telemetry during the arrhythmia. Thirty-nine induced arrhythmias from 26 different procedures in 19 patients with both pacemakers and ICDs were analyzed. Of the 39 arrhythmias, asynchronous pacemaker activity occurred in 16. The underlying mechanism was nonsensing in 4 episodes and noise reversion in 12 episodes. Clinically significant interference with detection arose on three occasions. Conditions favoring the occurrence of noise reversion include specific pacemaker models, arrhythmia cycle lengths in the range causing noise reversion of the individual pacemaker model, long noise sampling periods, and VVI pacing mode. Noise reversion can be diagnosed by telemetering the pacemaker marker channel during ventricular arrhythmias as a part of routine pacemaker-ICD interaction evaluation. It can be prevented or minimized by programming short ventricular refractory periods or using pacemakers with short retriggerable refractory periods.

Bradycardia↗

Randomized prospective pilot study of long-term dual-site atrial pacing for prevention of atrial fibrillation.

OBJECTIVE: To determine whether dual-site atrial pacing is feasible, safe, and effective. DESIGN: We undertook a randomized prospective single-blind crossover study. MATERIAL AND METHODS: Nine patients with at least two episodes per month of symptomatic paroxysmal atrial fibrillation participated in a randomized crossover study involving three separate 3-month blocks of single-site atrial pacing, dual-site atrial pacing, and control (support-only) pacing. RESULTS: Dual-site atrial pacing resulted in shorter P wave duration (81 +/- 14 ms) than did single-site pacing (111 +/- 12 ms) or control sinus rhythm (123 +/- 9 ms) (P<0.0001) and in fewer premature atrial complexes on Holter monitoring (P = 0.06). The arrhythmia-free interval was longer with dual-site pacing (67 +/- 17 days) than with single-site (62 +/- 30 days) or support-only (49 +/- 34 days) pacing (P = 0.10). This pilot study was not statistically powered to detect a difference between pacing modes. CONCLUSION: (1) Dual-site atrial pacing is feasible and safe; (2) it shortens the P wave duration and tends to decrease premature atrial complexes on Holter monitoring; (3) any atrial pacing tends to prolong the arrhythmia-free interval; and (4) this pilot study enrolled too few patients to determine whether a significant difference in pacing modes exists and supports the need for a larger study.

Adult↗

Symptomatic conduction system disease in cardiac amyloidosis.

Symptomatic conduction system disease in cardiac amyloidosis and its management has been reported infrequently. We report our experience of patients with amyloidosis having symptomatic conduction system disease requiring permanent pacemaker implantation.

Aged↗

Indications, effectiveness, and long-term dependency in permanent pacing after cardiac surgery.

The purposes of this study were to define predictors of long-term pacemaker dependency in patients having permanent pacemakers implanted shortly after cardiac surgery, and to evaluate short- and long-term results and survival in this population. Data from 120 adult patients with implantation since 1980 were retrospectively analyzed. Acute and chronic complication rates (4.2% and 16.6%, respectively) were not higher than those expected in the general paced population. In addition, continuous rhythm was evaluated by use of pacemaker inhibition in a subgroup of 20 patients to verify the validity of clinical criteria for pacemaker dependency. Of the patients evaluated for dependency, 41% eventually became nondependent. Prolonged monitoring with an inhibited pacemaker confirmed the accuracy of our method of clinical evaluation of pacemaker dependency. Significant predictors of long-term pacemaker dependency were complete atrioventricular block as the indication and bypass time of > 120 minutes (by multivariate and univariate analyses, respectively). Postoperative complete atrioventricular block is the most important predictor of pacemaker dependency, enabling an earlier decision on permanent pacemaker implantation (no later than the sixth and the ninth postoperative days for wide-complex and narrow-complex escape, respectively). Further prospective studies are needed to define optimal implantation times for indications other than complete atrioventricular block.

Adult↗

Interference with cardiac pacemakers by cellular telephones.

BACKGROUND: A growing body of evidence suggests that electromagnetic interference may occur between cardiac pacemakers and wireless hand-held (cellular) telephones, posing a potential public health problem. Electromagnetic interference may occur when the pacemaker is exposed to an electromagnetic field generated by the cellular telephone. METHODS: In this multicenter, prospective, crossover study, we tested 980 patients with cardiac pacemakers with five types of telephones (one analogue and four digital) to assess the potential for interference. Telephones were tested in a test mode and were programmed to transmit at the maximal power, simulating the worst-case scenario; in addition, one telephone was tested during actual transmission to simulate actual use. Patients were electrocardiographically monitored while the telephones were tested at the ipsilateral ear and in a series of maneuvers directly over the pacemaker. Interference was classified according to the type and clinical significance of the effect. RESULTS: The incidence of any type of interference was 20 percent in the 5533 tests, and the incidence of symptoms was 7.2 percent. The incidence of clinically significant interference was 6.6 percent. There was no clinically significant interference when the telephone was placed in the normal position over the ear. Interference that was definitely clinically significant occurred in only 1.7 percent of tests, and only when the telephone was held over the pacemaker. Interference was more frequent with dual-chamber pacemakers (25.3 percent) than with single-chamber pacemakers (6.8 percent, P<0.001) and more frequent with pacemakers without feed-through filters (28.9 to 55.8 percent) than with those with such filters (0.4 to 0.8 percent, P=0.01). CONCLUSIONS: Cellular telephones can interfere with the function of implanted cardiac pacemakers. However, when telephones are placed over the ear, the normal position, this interference does not pose a health risk.

Adolescent↗

Dual-chamber pacing for hypertrophic cardiomyopathy: a randomized, double-blind, crossover trial.

OBJECTIVES: In a double-blind, randomized, crossover trial we sought to evaluate the effect of dual-chamber pacing in patients with severe symptoms of hypertrophic obstructive cardiomyopathy. BACKGROUND: Recently, several cohort trials showed that implantation of a dual-chamber pacemaker in patients with severely symptomatic hypertrophic obstructive cardiomyopathy can relieve symptoms and decrease the severity of the left ventricular outflow tract gradient. However, the outcome of dual-chamber pacing has not been compared with that of standard therapy in a randomized, double-blind trial. METHODS: Twenty-one patients with severely symptomatic hypertrophic obstructive cardiomyopathy were entered into this trial after baseline studies consisting of Minnesota quality-of-life assessment, two-dimensional and Doppler echocardiography and cardiopulmonary exercise tests. Nineteen patients completed the protocol and underwent double-blind randomization to either DDD pacing for 3 months followed by backup AAI pacing for 3 months, or the same study arms in reverse order. RESULTS: Left ventricular outflow tract gradient decreased significantly to 55 +/- 38 mm Hg after DDD pacing compared with the baseline gradient of 76 +/- 61 mm Hg (p < 0.05) and the gradient of 83 +/- 59 mm Hg after AAI pacing (p < 0.05). Quality-of-life score and exercise duration were significantly improved from the baseline state after the DDD arm but were not significantly different between the DDD arm and the backup AAI arm. Peak oxygen consumption did not significantly differ among the three periods. Overall, 63% of patients had symptomatic improvement during the DDD arm, but 42% also had symptomatic improvement during the AAI backup arm. In addition, 31% had no change and 5% had deterioration of symptoms during the DDD pacing arm. CONCLUSIONS: Dual-chamber pacing may relieve symptoms and decrease gradient in patients with hypertrophic obstructive cardiomyopathy. In some patients, however, symptoms do not change or even become worse with dual-chamber pacing. Subjective symptomatic improvement can also occur from implantation of the pacemaker without its hemodynamic benefit, suggesting the role of a placebo effect. Long-term follow-up of a large number of patients in randomized trials is necessary before dual-chamber pacing can be recommended for all patients with severely symptomatic hypertrophic obstructive cardiomyopathy.

Adult↗

Pacing mode and long-term survival in elderly patients with congestive heart failure: 1980-1985.

Dual-chamber pacing may improve short-term hemodynamics and functional class in some patients with congestive heart failure, even in the absence of conventional indications for pacemaker implantation. However, the impact of different pacing modes on survival of patients with congestive heart failure is controversial. In this retrospective study we analyzed survival data from 546 elderly patients, aged 70 years and older, who underwent implantation of a permanent dual-chamber (DDD, n = 62, DVI, n = 102) or single-chamber (VVI) pacemaker (n = 382) between 1980 and 1985. Survival was further analyzed according to the presence of absence of congestive heart failure, and pacemaker mode (DDD vs. DVI vs. VVI). Overall, dual-chamber pacing (DDD and DVI) was associated with a more favorable long-term outcome when compared with single-chamber ventricular pacing, although differences were only significant for DDD pacing (P = 0.002). When patients with and without preexisting congestive heart failure were analyzed separately, survival following dual-chamber pacing (DDD and DVI) was significantly better than survival following single-chamber pacing in patients without congestive heart failure (P = 0.03), but not in patients with preexisting heart failure (P = 0.139). When patients were analyzed according to the electrophysiological indication for pacemaker implantation, overall survival of patients with AV block (P = 0.0025) but not sinus node dysfunction (P = 0.346) was improved with dual-chamber pacing. This survival advantage in patients with AV block following dual-chamber pacing was lost in the presence of heart failure (P = 0.11). These findings suggest that dual-chamber pacing, in particular DDD pacing, improves the survival in elderly patients without preexisting congestive heart failure. In contrast to the short-term hemodynamic improvement observed in selected patients with congestive heart failure, dual-chamber pacing in elderly patients with congestive heart failure, paced for conventional indications, is not associated with improved survival when compared with single-chamber ventricular pacing.

Aged↗