Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET.

High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.

Algorithms↗

Statistical pixelwise inference models for planar data analysis: an application to gamma-camera uniformity monitoring.

In this paper two tests based on statistical models are presented and used to assess, quantify and provide positional information of the existence of bias and/or variations between planar images acquired at different times but under similar conditions. In the first test a linear regression model is fitted to the data in a pixelwise fashion, using three mathematical operators. In the second test a comparison using z-scoring is used based on the assumption that Poisson statistics are valid. For both tests the underlying assumptions are as simple and few as possible. The results are presented as parametric maps of either the three operators or the z-score. The z-score maps can then be thresholded to show the parts of the images which demonstrate change. Three different thresholding methods (naive, adaptive and multiple) are presented: together they cover almost all the needs for separating the signal from the background in the z-score maps. Where the expected size of the signal is known or can be estimated, a spatial correction technique (referred to as the reef correction) can be applied. These tests were applied to flood images used for the quality control of gamma camera uniformity. Simulated data were used to check the validity of the methods. Real data were acquired from four different cameras from two different institutions using a variety of acquisition parameters. The regression model found the bias in all five simulated cases and it also found patterns of unstable regions in real data where visual inspection of the flood images did not show any problems. In comparison the z-map revealed the differences in the simulated images from as low as 1.8 standard deviations from the mean, corresponding to a differential uniformity of 2.2% over the central field of view. In all cases studied, the reef correction increased significantly the sensitivity of the method and in most cases the specificity as well. The two proposed tests can be used either separately or in combination and are capable of showing trends and/or the magnitude of difference between images acquired under similar conditions with high positional and statistical precision. In addition to gamma camera quality control, they could be applied to any pair (or set) of registered planar images to detect subtle changes, e.g. a set of scintigrams or conventional radiographs of a patient before, during and after treatment.

Computer Simulation↗

Evaluation of the Cockroft-Gault, Jelliffe and Wright formulae in estimating renal function in elderly cancer patients.

BACKGROUND: More elderly patients are being treated with chemotherapy. Reliable and accurate measures of renal function are needed to obtain predictable, safe and effective exposure to renally excreted drugs. The Jelliffe, Cockroft-Gault and Wright formulae have been used to evaluate renal function, although they have not been validated in elderly oncology patients. We performed a retrospective evaluation of these formulae using the [51Cr]-ethylenediamine tetraacetic acid ([51Cr]-EDTA) method of measuring glomerular filtration rate (GFR) as the 'gold standard'. PATIENTS AND METHODS: Inclusion criteria were age > or = 70 years and serum creatinine <250 micromol/l, performed within 4 weeks of glomerular filtration rate (GFR) measurement. Creatinine clearance was calculated using the Cockroft-Gault, Jelliffe and Wright formulae. The precision and accuracy of the three formulae were compared with the gold standard. RESULTS: Two hundred and twenty-five patients were evaluated: median age, 74 years (range 70-89); males, 108; females, 117; median creatinine, 84 micromol/l (range 44-186). Correlation coefficients of the Jelliffe, Cockroft-Gault and Wright formulae were similar. In the specific GFR ranges of 50-70, 70-90 and 90-120 ml/min, the bias [mean percentage error (MPE)] was +8%, -4% and -13%, respectively. The degree of bias was greater with the Cockroft-Gault and Jelliffe formulae across the same range of GFR with the MPE being -15%, -25%, -32% and -12%, -19% and -23%, respectively. All three formulae have reduced precision and greater bias at the extremes of GFR. CONCLUSIONS: The Wright formula is the most accurate, precise and least biased formula for the calculation of GFR in elderly patients with a GFR >50 ml/min. These results allow the physician to make a decision regarding the use of the formula based on an expected degree of bias.

Aged↗

Comparison of myocardial gated single photon emission computerised tomography, planar radionuclide ventriculography and echocardiography in evaluating left ventricular ejection fraction, wall thickening and wall motion.

Left ventricular ejection fraction (LVEF) and wall thickening are fundamental aspects of cardiac function. Recently, gated single photon emission computerised tomography (GSPECT) and anatomical M-mode echocardiography are new techniques, which have been introduced for the evaluation of left ventricular wall thickening and ejection fraction. These, however, have not been evaluated against established techniques, including equilibrium radionuclide ventriculography (ERNV), which remains the current gold standard for the evaluation of LVEF. We examined the concordance between LVEF, wall motion and wall thickening scores derived from GSPECT, echocardiography and ERNV, in a group of 16 patients with suspected ischaemic heart disease. Estimated ejection fraction correlated better between ERNV and gated SPECT (R2 = 0.93) than between echocardiography and either gated SPECT (R2 = 0.62) or ERNV (R2 = 0.71). There was poor correlation between gated SPECT and anatomical M-mode echocardiography in the assessment of wall thickening (83/150, 56%; kappa= 0.31, p < 0.05) and similar correlation (100/150, 66%; kappa = 0.29, p < 0.01) for wall motion analysis. In conclusion, estimations of ejection fraction by all the three studied modalities agreed to a degree sufficient for routine clinical practice. However, estimates of wall thickening from echocardiography cannot be used interchangeably with those derived from gated myocardial perfusion SPECT.

Adult↗

Scaling images using their background ratio. An application in statistical comparisons of images.

Comparison of two medical images often requires image scaling as a pre-processing step. This is usually done with the scaling-to-the-mean or scaling-to-the-maximum techniques which, under certain circumstances, in quantitative applications may contribute a significant amount of bias. In this paper, we present a simple scaling method which assumes only that the most predominant values in the corresponding images belong to their background structure. The ratio of the two images to be compared is calculated and its frequency histogram is plotted. The scaling factor is given by the position of the peak in this histogram which belongs to the background structure. The method was tested against the traditional scaling-to-the-mean technique on simulated planar gamma-camera images which were compared using pixelwise statistical parametric tests. Both sensitivity and specificity for each condition were measured over a range of different contrasts and sizes of inhomogeneity for the two scaling techniques. The new method was found to preserve sensitivity in all cases while the traditional technique resulted in significant degradation of sensitivity in certain cases.

Algorithms↗

A comparison of the progression of early Parkinson's disease in patients started on ropinirole or L-dopa: an 18F-dopa PET study.

OBJECTIVE: To study the relative rates of progression of early Parkinson's disease (PD) in patients started on a dopamine agonist, ropinirole, or L-dopa. METHODS: A double-blind study of 45 early PD patients [mean age 61 +/- 9.8 SD and mean symptom duration, 26 +/- 16 SD months] randomized 2 : 1 (ropinirole : L-dopa). Supplementary L-dopa was allowed if, during the trial, there was lack of a therapeutic effect. (18)F-dopa PET scans were performed at baseline (n = 45) and 2 years (n = 37). RESULTS: At two years, the mean percentage reduction in putamen (18)F-dopa uptake (Ki(o)) was not significantly different between the two groups (13% ropinirole, n = 28 versus 18% L-dopa, n = 9). CONCLUSIONS: We found no significant overall difference in underlying PD progression, after two years treatment, between patients groups. In summary, (18)F-dopa PET can be employed to objectively evaluate the effect of potential neuroprotective agents on dopaminergic function.

Aged↗

Diamino benzo[b]thiophene derivatives as a novel class of active site directed thrombin inhibitors. 5. Potency, efficacy, and pharmacokinetic properties of modified C-3 side chain derivatives.

A systematic investigation of the structure-activity relationships of the C-3 side chain of the screening hit 1a led to the identification of the potent thrombin inhibitors 23c, 28c, and 31c. Their activities (1240, 903, and 1271 x 10(6) L/mol, respectively) represent 2200- and 2900-fold increases in potency over the starting lead 1a. This activity enhancement was accomplished with an increase of thrombin selectivity. The in vitro anticoagulant profiles of derivatives 28c and 31c were determined, and they compare favorably with the clinical agent H-R-1-[4aS, 8aS]perhydroisoquinolyl-prolyl-arginyl aldehyde (D-Piq-Pro-Arg-H; 32). The more potent members of this series have been studied in an arterial/venous shunt (AV shunt) model of thrombosis and were found to be efficacious in reducing clot formation. However, their efficacy is currently limited by their rapid and extensive distribution following administration.

Animals↗

Physical characteristics of the ECAT EXACT3D positron tomograph.

The 'EXACT3D' positron tomograph, which is now in routine clinical research use, was developed with the aim of achieving unprecedented sensitivity, high spatial and temporal resolution and simplicity of design using proven detector technology. It consists of six rings of standard detector blocks (CTI/Siemens EXACT HR+) with 4.39 mm x 4.05 mm x 30 mm elements, giving an axial field of view (FOV) of 23.4 cm. This extended FOV and the absence of interplane septa and retractable transmission rod sources has allowed greatly simplified gantry and detector cassette design. Operation in exclusive 3D mode requires an alternative to the conventional coincidence method for transmission scanning, and a single photon approach using a hydraulically driven 137Cs point source has been implemented. The tomograph has no other moving parts. A single time frame of data without any compression is very large (> 300 Mbyte) and two approaches are employed to overcome this difficulty: (a) adjacent sinograms can be summed automatically into different combinations and (b) listmode (event-by-event) acquisition has been instituted, which is both storage efficient (particularly for acquisition of sparse data sets) and maximizes temporal resolution. The high-speed I/O and computing hardware can maintain a sustained acquisition rate of about 4 million coincidence events per second. A disadvantage of the large axial FOV in 3D is the increased sensitivity to activity outside the coincidence FOV. However, this can be minimized by additional side shielding. The mean spatial resolution is 4.8 +/- 0.2 mm FWHM (transaxial, 1 cm off-axis) and 5.6 +/- 0.5 mm (axial, on-axis). Its absolute efficiency is 5.8% for a line source in air (just spanning the axial FOV) and 10% for a central point source (with thresholds of 350-650 keV). For a uniform 20 cm diameter cylinder, the efficiency is 69 kcps kBq(-1) ml(-1) (after subtraction of a scatter fraction of 42%). Sensitivity relative to the EXACT HR+ (with four rings of blocks) is 2.5 (3D) and 12 (2D) times respectively. The rate of random events in blood flow studies in the brain and body, using 15O-labelled water, can be controlled by limiting the administered dose and inserting additional side shielding.

Cesium Radioisotopes↗

Regional mucociliary clearance in patients with cystic fibrosis.

This paper reports on a large retrospective analysis of mucociliary clearance (MCC) studies in a group of 59 patients with cystic fibrosis (CF) and 17 age-matched healthy subjects. As many of the CF patients were studied on multiple occasions, a total of 184 patient studies are presented. MCC was measured using a radioaerosol and gamma camera technique. In addition to whole lung clearance, MCC was measured from the central, intermediate, peripheral, basal, mid and apical regions of the lung. MCC was markedly decreased in the CF patient group. Not only was whole lung clearance (14.2 +/- 1.4% vs. 28.0 +/- 3.7%) impaired, but also clearance from the central (19.1 +/- 1.9% vs. 35.6 +/- 4.3%), intermediate (10.7 +/- 1.6% vs. 25.5 +/- 3.7%), apical (12.4 +/- 2.6% vs. 31.6 +/- 4.6%) and mid (14.0 +/- 1.9% vs. 30.4 +/- 4.0%) regions. Attempts were made to identify factors that may have influenced MCC in both the normal subjects and CF patients. Age, gender, body mass index, patient genotype, penetration index, spontaneous cough, and various lung function parameters were entered into a stepwise multiple regression model, but none of the factors proved to be statistically important in determining MCC. Both intrasubject repeatability and intersubject variability estimates are presented for the patients and normal subjects that had multiple studies. The values were found to be remarkably similar for both CF patients and normal subjects and for both intra- and intersubject repeatability. With marked deviation from normal ranges and good repeatability, the measurement of MCC in CF patients would seem to be a valuable outcome measure for clinical trials involving new pharmaceuticals and physical therapy designed to improve removal of secretions from the airways.

Adolescent↗

Dibasic benzo[b]thiophene derivatives as a novel class of active site directed thrombin inhibitors: 2. Sidechain optimization and demonstration of in vivo efficacy.

Potent, subnanomolar thrombin inhibitors 4, 5, and 6 are developed through side chain optimization of novel, benzo[b]thiophene-based small organic entities 2 and 3 and through SAR additivity studies of the new structural elements identified. X-ray crystallographic studies of 4b-thrombin complex revealed a hydrophobic and an electrostatic interaction of these new elements with thrombin at the S2 and S3 binding sites. In vitro and in vivo pharmacological studies showed that 4, 5, and 6 are potent anticoagulants in human plasma with demonstrated antithrombotic efficacy in a rat model of thrombosis.

Animals↗

A dimeric form of Escherichia coli succinyl-CoA synthetase produced by site-directed mutagenesis.

Succinyl-CoA synthetase (SCS) catalyzes the substrate-level phosphorylation step of the citric acid cycle. The enzyme from Escherichia coli is an (alphabeta)2-heterotetramer with two active sites, one in each alphabeta-dimer. To determine whether the two active sites could function independently, mutations were made to split the tetramer into alphabeta-dimers. Because two choices for the tetramer (I and II) were possible from the X-ray crystallographic analyses, mutations were made at two different interfaces. All mutations based on tetramer I resulted in an intact tetramer. Of the two mutants based on tetramer II, one was insoluble and the other, where M156beta, Y158beta, R161beta and E162beta were changed to D, D, E and R, respectively, was a dimer. This quaternary structure was confirmed by fast protein liquid chromatography, blue native PAGE and ultracentrifugation. The DDER mutant has kinetic parameters similar to the tetrameric E. coli enzyme. Like the tetrameric enzyme, it shows ATP-facilitated dethiophosphorylation, proving that this property is a single-site effect. The ATP-facilitated dethiophosphorylation is inhibited by phosphate. It is concluded that dimerization of alphabeta-dimers is not a prerequisite for catalytic competency nor for alternating sites cooperativity in the tetramer. The rationale behind the dimer-of-dimers in E. coli SCS is still not known, but increased solubility, increased stability and in vivo interactions of the tetramer with other proteins are still possibilities.

Amino Acid Sequence↗

Randoms variance reduction in 3D PET.

In positron emission tomography (PET), random coincidence events must be removed from the measured signal in order to obtain quantitatively accurate data. The most widely implemented technique for estimating the number of random coincidences on a particular line of response is the delayed coincidence channel method. Estimates obtained in this way are subject to Poisson noise, which then propagates into the final image when the estimates are subtracted from the prompt signal. However, this noise may be reduced if variance reduction techniques similar to those used in normalization of PET detectors are applied to the randoms estimates prior to use. We have investigated the effects of randoms variance reduction on noise-equivalent count (NEC) rates on a whole-body PET camera operating in 3D mode. NEC rates were calculated using a range of phantoms representative of situations that might be encountered clinically. We have also investigated the properties of three randoms variance reduction methods (based on algorithms previously used for normalization) in terms of their systematic accuracy and their variance reduction efficacy, both in phantom studies and in vivo. Those algorithms investigated that do not make assumptions about the spatial distribution of random coincidences give the best estimates of the randoms distribution. With the camera used, which has a limited axial extent (10.8 cm) and a large ring diameter (102 cm), the gains in image signal-to-noise ratio obtained with this technique ranged from approximately 5% to approximately 15%, depending on object size, activity distribution and the amount of activity in the field of view. Larger gains would be expected if this technique were to be employed on cameras of greater axial extent and smaller ring diameter.

Algorithms↗

Frontal, midbrain and striatal dopaminergic function in early and advanced Parkinson's disease A 3D [(18)F]dopa-PET study.

We have studied focal changes in dopaminergic function throughout the brain volume in early and advanced Parkinson's disease by applying statistical parametric mapping (SPM) to 3D [(18)F]dopa-PET. Data from seven early hemi-Parkinson's disease and seven advanced bilateral Parkinson's disease patients were compared with that from 12 normal controls. Parametric images of [(18)F]dopa influx rate constant (K(i)(o)) were generated for each subject from dynamic 3D [(18)F]dopa datasets and transformed into standard stereotactic space. Significant changes in mean voxel [(18)F]dopa K(i)(o) values between the normal control group and each Parkinson's disease group were localized with SPM. Conventional region of interest analysis was also applied to comparable regions on the untransformed image datasets. In early left hemi-Parkinson's disease, significant extrastriatal increases in [(18)F]dopa K(i)(o) were observed in the left anterior cingulate gyrus and the dorsal midbrain region (P < 0.05, corrected) along with decreases in striatal [(18)F]dopa K(i)(o). In advanced Parkinson's disease, significant extrastriatal decreases in [(18)F]dopa K(i)(o) were observed in the ventral and dorsal midbrain regions (P < 0.05, corrected). No significant changes in [(18)F]dopa K(i)(o) were observed in the anterior cingulate region. In a direct comparison between the early and late Parkinson's disease groups, we observed relative [(18)F]dopa K(i)(o) reductions in ventral and dorsal midbrain, and dorsal pontine regions along with striatal [(18)F]dopa K(i)(o) reductions. Similiar results were found with a region of interest approach, on non-transformed data, except for the focal midbrain [(18)F]dopa K(i)(o) increase seen in early Parkinson's disease. In conclusion, using SPM with [(18)F]dopa-PET, we have objectively localized changes in extrastriatal, pre-synaptic dopaminergic function in Parkinson's disease. The significance of the increased dopaminergic activity of anterior cingulate in early Parkinson's disease remains unclear, but may be compensatory. The [(18)F]dopa signal in dorsal midbrain and pontine regions suggests that [(18)F]dopa is taken up by serotonergic and noradrenergic neurons which also degenerate in advanced Parkinson's disease. This suggests, therefore, that Parkinson's disease is a monoaminergic neurodegenerative disorder.

Biological Transport↗

Statistical parametric mapping with 18F-dopa PET shows bilaterally reduced striatal and nigral dopaminergic function in early Parkinson's disease.

OBJECTIVE: To apply statistical parametric mapping to 18F-dopa PET data sets, to examine the regional distribution of changes in dopaminergic metabolism in early asymmetric Parkinson's disease. METHODS: Thirteen normal volunteers (age 57.7 (SD 16.5) years; four women, nine men ) and six patients (age 50.3 (SD 13.5) years; three women, three men) with asymmetric (right sided) Parkinson's disease were studied. Images from each dynamic dopa PET dataset were aligned and parametric images of 18F-dopa influx (Ki) were created for each subject. The Ki images were transformed into standard stereotactic space. The Ki values of the caudate and putamen on spatially normalised images were compared with the Ki values before normalisation. The application of statistical parametric mapping (SPM) allowed statistical comparison of regional Ki values on a voxel by voxel basis between healthy volunteers and patients with Parkinson's disease. RESULTS: There was a strong correlation between the Ki values before and after spatial normalisation (r=0.898, p=0.0001). Significant decreases in the Ki values were found for the Parkinson's desease group throughout the entire left putamen (p< 0.001) and focally in the dorsal right putamen (p<0.001). Decreased Ki values were also shown bilaterally in the substantia nigra (p< 0.01). CONCLUSION: Using (SPM) and 18F-dopa PET, reductions in both striatal and nigral brain dopaminergic function could be demonstrated in early Parkinson's disease.

Adult↗

Transmission scanning in emission tomography.

Attenuation correction in single-photon (SPET) and positron emission (PET) tomography is now accepted as a vital component for the production of artefact-free, quantitative data. The most accurate attenuation correction methods are based on measured transmission scans acquired before, during, or after the emission scan. Alternative methods use segmented images, assumed attenuation coefficients or consistency criteria to compensate for photon attenuation in reconstructed images. This review examines the methods of acquiring transmission scans in both SPET and PET and the manner in which these data are used. While attenuation correction gives an exact correction in PET, as opposed to an approximate one in SPET, the magnitude of the correction factors required in PET is far greater than in SPET. Transmission scans also have a number of other potential applications in emission tomography apart from attenuation correction, such as scatter correction, inter-study spatial co-registration and alignment, and motion detection and correction. The ability to acquire high-quality transmission data in a practical clinical protocol is now an essential part of the practice of nuclear medicine.

Algorithms↗

Parametric image reconstruction using spectral analysis of PET projection data.

Spectral analysis is a general modelling approach that enables calculation of parametric images from reconstructed tracer kinetic data independent of an assumed compartmental structure. We investigated the validity of applying spectral analysis directly to projection data motivated by the advantages that: (i) the number of reconstructions is reduced by an order of magnitude and (ii) iterative reconstruction becomes practical which may improve signal-to-noise ratio (SNR). A dynamic software phantom with typical 2-[11C]thymidine kinetics was used to compare projection-based and image-based methods and to assess bias-variance trade-offs using iterative expectation maximization (EM) reconstruction. We found that the two approaches are not exactly equivalent due to properties of the non-negative least-squares algorithm. However, the differences are small (< 5%) and mainly affect parameters related to early and late time points on the impulse response function (K1 and, to a lesser extent, VD). The optimal number of EM iteration was 15-30 with up to a two-fold improvement in SNR over filtered back projection. We conclude that projection-based spectral analysis with EM reconstruction yields accurate parametric images with high SNR and has potential application to a wide range of positron emission tomography ligands.

Algorithms↗