Search PubMed⌕ Search

Biomedical subjects

D Koutsouris

Publications and source records attributed to D Koutsouris.

43 records · Page 3Linked to original sources

Thermal transitions of red blood cell deformability. Correlation with membrane rheological properties.

Red blood cell deformability has been studied by the initial filtration flow rate as a function of temperature. The well-known transition at 49-50 degrees C (probably due to spectrin denaturation) is shown. Another transition is demonstrated around 18 degrees C (the cell becomes stiffer below this temperature range). The erythrocyte membranes prepared by a mild dialysis technique have the same deformability as intact erythrocytes at room temperature; they also show the same low-temperature transition. No such transition has been found for hemoglobin solutions of viscosity 30 g X dl-1. It is interesting to compare these results with those obtained by other methods which measure the properties of natural or artificial lipid membranes and which also demonstrate a thermal transition at 15-20 degrees C. Therefore, the deformability of intact normal erythrocytes seems to depend mainly on the rheological properties of the membrane.

Erythrocyte Membrane↗

Determination of erythrocytes transit times through a 5 mu "nuclepore" filter.

Filtration experiments through 5 or 3 mu Nuclepore membranes are often performed in order to assess the so-called erythrocyte deformability. The relation between this parameter and the RBC filterability is not straightforward. A simple theoretical treatment relating filtration index (as determined by the initial flow rate method) to the average RBC flow resistance through an average pore is presented. In order to deduce the average RBC transit time through the membrane from the initial flow rate data, the suspension hematocrit change after filtration has been determined. The calculated average transit time is comparable to experimental values, as determined by KIESEWETTER et al. with the single pore technique.

Erythrocytes↗

In vitro estimation of red blood cells' aggregation using ultrasound Doppler techniques.

Aggregation of red blood cells (RBCs) is one of the principal hemorheological factors which plays an important role in capillary circulation. In order to study RBC's aggregation, an ultrasound Doppler in vitro technique, using pulsed wave monoelement pencil 4 MHz probes, was designed. A hydraulic pump system has been implemented, using an electric step motor that establishes in a certain distance, a laminar blood flow profile into a rectangular cross-section plexiglass tube. Blood coming from blood collection bags was used and following certain typical measuring protocols, red blood cells' samples of various parameters and conditions were acquired. Adding dextrans to the blood samples, red blood cells aggregation was achieved and observed for various hematocrit values. Both the emitted and the backscattered signals were driven to a system containing a multi-channel digital oscilloscope--of high sampling rate and processing capabilities--and a powerful PC with a high acquisition A/D card and special control software. The estimation of mean aggregates size--by measuring the mean ultrasonic intensity scattered by the blood sample--led us to a qualitative, in vitro ultrasonic method.

Dextrans↗