Temporary restorative materials: properties and uses.

Various materials used for temporary restorations are reviewed, with reference to their chemical and physical properties. Research and standard specifications should be instituted in order to standardize and improve the many products now available to the profession. Knowledge of the materials and their properties will enable the dentist to arrive at correct selection of the material for each case, thus promoting more successful clinical procedures.

Acetates↗

Rationalization of electric pulp-testing methods.

A new electric pulp-testing system, the Testark, was developed in order to assess the potential of a different way of testing pulp sensitivity, thus making this electric pulp test more dependable than the conventional electric pulp-testing method. A study was conducted to evaluate the potential of the Testark system in comparison with a commercially available pulp tester. This pilot study consisted of application of three different desensitizing agents (sodium fluoride, test product. 'A', and test product 'B') to the cervical areas of hypersensitive teeth. The results were recorded with both the Testark and the conventional pulp tester simultaneously, and the sodium fluoride and test product 'B' proved to yield a beneficial effect by desensitizing the teeth after a single application. The level of desensitization with these agents was higher than the level obtained with the test product 'A' paste, which was utilized daily for 14 days. The results obtained with the conventional pulp tester differed by way of interpretation from those obtained with the Testark system. The Testark system proved to be easy to use and highly accurate in the data readings because of its high resolution. The Testark systemwas found to be more dependable than the commerical pulp tester, since it reduced the subjective errors which are inevitable when a commerical pulp tester is used. The Testark system is being developed further, and more studies are being conducted at the present time, in order to assess the full potential of the instrument.

Adult↗

Laser evaluation of handpiece contamination.

Six different models of ultra-high speed handpieces were evaluated in regard to debris accumulation following cutting through tooth structure. A weight-load machine and a laser particle detector were utilized to evaluate the amount of the debris retained. Amounts of debris accumulated after dry and wet cutting were also evaluated. The effect of simple wiping of the handpieces with alcohol guaze was assessed. The results obtained show that the longer the cutting time, the larger the amounts of debris retained on the handpieces. Dry cutting resulted in smaller amounts of debris entrapped than following wet cutting. The cleaning by wiping with alcohol gauze reduced the amounts of the debris, but is insufficient and cannot be utilized as a single procedure for decontaminating handpieces. The external head design is a cardinal factor in retention of debris: larger but smoother surfaces will retain less debris than smaller but more complicated surfaces. External tubings are debris retention foci.

Clinical Trials as Topic↗