Optimal use of directional coronary atherectomy is required to ensure long-term angiographic benefit: a study with matched procedural outcome after atherectomy and angioplasty.

OBJECTIVES: This study was designed to examine whether restenosis is related to the extent or mechanism of lumen improvement and to explore angiographic determinants of optimal atherectomy. BACKGROUND: Directional atherectomy induces a greater extent of immediate gain and late loss but has not been found to yield a better late angiographic lumen than angioplasty in randomized trials. The difference in lumen renarrowing may be related to either the extent or the mechanism of immediate gain. The design of previous studies has precluded the detection of a device-specific effect on restenosis. METHODS: A retrospective analysis was based on matching a prospectively collected series of 80 native coronary arteries successfully treated with atherectomy with a prospectively collected series of 80 native coronary arteries successfully treated with balloon angioplasty. Angiographic analysis was performed in 160 lesions to explore whether a specific device-related effect exists. Multivariate analyses were performed to determine the correlates of minimal lumen diameter at follow-up and late lumen loss and to identify the procedural characteristics for optimal atherectomy. RESULTS: Matching resulted in two comparable groups with equivalent baseline clinical and stenosis characteristics. By study design, atherectomy and angioplasty resulted in similar mean (+/- SD) immediate lumen gain (1.15 +/- 0.44 vs. 1.10 +/- 0.40 mm, p = 0.50). However, lumen loss was more pronounced after atherectomy, and, thus, the minimal lumen diameter at follow-up differed significantly between the two groups (1.78 +/- 0.57 vs. 2.00 +/- 0.56 mm, p = 0.001). Device type was retained in the multivariate analysis as an independent predictor of late minimal lumen diameter and lumen loss. Multivariate analysis identified vessel size and immediate gain as determinants of optimal atherectomy. CONCLUSIONS: Restenosis is a consequence not only of the extent of lumen improvement but also of the mechanism of vessel wall injury (debulking vs. dilating). While performing atherectomy, the operator should strive for an optimal procedural result to accommodate an increased intimal hyperplastic response.

Angioplasty, Balloon↗

Quantitative coronary angiography in the estimation of the functional significance of coronary stenosis: correlations with dobutamine-atropine stress test.

OBJECTIVES: The purpose of this study was to determine the predictive value of quantitative coronary angiography in the assessment of the functional significance of coronary stenosis as judged from the development of left ventricular wall motion abnormalities during dobutamine-atropine stress echocardiography. BACKGROUND: Coronary angiography is the reference method for assessment of the accuracy of noninvasive diagnostic imaging techniques to detect the presence of significant coronary stenosis. However, use of arbitrary cutoff criteria for the interpretation of angiographic data may considerably influence the true diagnostic accuracy of the technique investigated. METHODS: Thirty-four patients without previous myocardial infarction and with single-vessel coronary stenosis were studied with both quantitative angiography and dobutamine-atropine stress echocardiography. Two different techniques of quantitative angiographic analysis--edge detection and videodensitometry--were used for measurement of minimal lumen diameter, percent diameter stenosis and percent area stenosis. Two-dimensional echocardiographic images were collected during incremental doses of intravenous dobutamine and later analyzed using a 16-segment left ventricular model. Angiographic cutoff criteria were derived from receiver-operating curves to define the functional significance of coronary stenosis on the basis of dobutamine-atropine stress echocardiography. RESULTS: The angiographic cutoff values with the best predictive value for the development of left ventricular wall motion abnormalities during dobutamine-atropine stress echocardiography were minimal lumen diameter of 1.07 mm, percent diameter stenosis of 52% and percent area stenosis of 75%. Minimal lumen diameter was found to have the best predictive value for a positive dobutamine stress test (odds ratio 51, sensitivity 94%, specificity 75%). CONCLUSIONS: Automated quantitative angiographic measurement of minimal lumen diameter is a practical and useful index for determining both the anatomic and functional significance of coronary stenosis, and a value of 1.07 mm is the best predictor for a positive dobutamine stress test.

Adult↗

Comparison of biphasic and monophasic waveforms in epicardial atrial defibrillation.

OBJECTIVES: Because biphasic waveforms have previously been shown to be more efficient than monophasic waveforms in defibrillation of the ventricle, we compared the efficiency of the two waveforms in defibrillation of the atria. BACKGROUND: The development of an implantable atrial defibrillator would offer significant advantages over current approaches to the management of atrial fibrillation. Patient tolerance of atrial shocks from such a device, however, would depend critically on the deployment of an efficient waveform. METHODS: Both the monophasic and biphasic shocks were of 8-ms duration, and the biphasic was a dual-capacitor waveform with equal first- and second-phase duration and leading-edge voltage. One hundred randomized atrial shocks were evaluated in 21 patients during cardiopulmonary bypass. Atrial fibrillation was induced by the application of alternating current. Atrial shocks were delivered through customized, contoured epicardial paddles applied to the posterior left atrial wall (surface area 11 cm2) and to the anterior right atrial wall (surface area 26 cm2). RESULTS: For the monophasic waveform the delivered energy (joules) associated with 50% success (E50) was 1.44 J (95% confidence interval [CI] 0 to 11.2) and with 80% (E80) success 3.9 J (95% CI 2.42 to 109.8); for the biphasic waveform 50% success was achieved with 0.37 J (95% CI 0.36 to 0.38) (p = NS) and 80% success with 0.57 J (95% CI 0.56 to 0.58) (p < 0.05). CONCLUSIONS: A biphasic waveform is more efficient than a monophasic waveform in atrial defibrillation. This may have implications for the development of an implantable atrial defibrillator for paroxysmal atrial fibrillation in addition to improvement of elective transthoracic and endocardial cardioversion of chronic atrial fibrillation.

Aged↗

Refusing care to emergency department of patients: evaluation of published triage guidelines.

STUDY OBJECTIVE: To determine whether a set of published triage guidelines identifies patients who can safely be refused emergency department care. DESIGN: Historical cohort study. SETTING: A public hospital ED. TYPE OF PARTICIPANTS: All patients triaged during a one-week period who were not in the most acute triage category. MEASUREMENTS: Two ED nurses, blinded to the study hypothesis, reviewed each triage sheet to determine whether the case met the published guidelines for refusing care. In addition, each ED record was reviewed for appropriateness; a visit was considered appropriate only if predetermined, explicit criteria were met and an emergency physician agreed that a 24-hour delay in care might have worsened the patient's outcome. MAIN RESULTS: Of the 106 patients who would have been refused care according to the triage guidelines, 35 (33%) had appropriate visits. Four were hospitalized. CONCLUSION: When tested in our patient population, the triage guidelines were not sufficiently sensitive to identify patients who needed ED care. Broad application of these guidelines may jeopardize the health of some patients.

Adult↗

Temporal variability and correlation with geometric parameters in vasospastic angina: a quantitative angiographic study.

Long-term changes in vasocontractility were examined in 23 coronary segments from 20 patients with variant angina using computer-based quantitative coronary angiography and ergonovine provocation tests repeated at an interval of 42 +/- 14 months. Measurements of vasospasticity at the sites of fixed stenoses were compared with values predicted by an elementary geometric theory based on the assumption that the cross-sectional area of a vessel wall is constant regardless of its state of vasoconstriction. While all patients were symptomatic initially, only 11 remained symptomatic at follow-up. At the initial provocation test, the response was correctly predicted in four segments, was lower than expected in one, and was stronger in 18. At follow-up, only one of the four segments in which the response had been initially predicted correctly again showed the predicted response and the remaining three showed a response weaker than expected; the one segment which was initially hypocontractile remained hypocontractile at follow-up; and of the 18 segments which were initially hypercontractile, 12 exhibited hypercontractility again, four had the predicted value and the remaining two showed hypocontractility. In only one of 23 segments did the geometric theory predict the behaviour of vasospasticity at the site of fixed stenosis on both tests. Vasospastic responsiveness is a dynamic process demonstrating temporal variability and is not directly predicted by geometric theory.

Angina Pectoris, Variant↗

Impact of pulse characteristics on atrial defibrillation energy requirements.

In summary, many issues pertaining to pulse characteristics and atrial defibrillation remain unsolved. Perhaps the most burning questions are whether a further reduction in atrial defibrillation energy requirements can be achieved by the combination of biphasic waveforms with dual pathway sequential shocks to produce a more homogenous distribution of charge, whether right and left atrial polarity of the first phase of asymmetrical biphasic shocks can reduce energy requirements in individual patients and whether the delivery of very long biphasic shocks (possibly > 20 msec) can reduce the discomfort of shorter shocks by decreasing the peak current density. Only then will the wide-spread acceptance of the implantable atrial defibrillator become closer to reality.

Animals↗

Clinical and angiographic outcome following implantation of the new Less Shortening Wallstent in aortocoronary vein grafts: introduction of a second generation stent in the clinical arena.

One of the factors felt to have contributed to the high rate of stent occlusion in the European registry of the coronary Wallstent in the 1980s was the frequent deployment of more than one stent to cover the target lesion. This resulted from a high degree of shortening of the Wallstent upon expansion. To overcome this limitation the design of the Wallstent was modified to reduce the degree of shortening. We report the results of a study of the first patients to undergo implantation of the new Less Shortening Wallstent. Thirty-five Wallstents were electively deployed in aortocoronary vein grafts in 29 patients. Stent deployment was successful in 35 of 36 attempts in 30 lesions. In five of the 30 lesions, a second stent was required to cover the proximal portion of the lesion. Angiographic success (< 50% residual diameter stenosis as determined by off-line quantitative coronary angiography) was achieved in all 29 patients. During the in-hospital phase, no major adverse cardiac event occurred (reintervention, re-CABG, myocardial infarction, or death) and five patients had hemorrhagic complications. Following hospital discharge, one patient had a subacute stent occlusion associated with symptoms and elevated cardiac enzymes at 11 days, another patient had symptoms and elevated cardiac enzymes (CK 300 U/I) at 22 days with a patent stent, five patients required balloon angioplasty within the 6 month follow-up period (four for restenosis and one for stent occlusion), one patient underwent re-CABG for a native artery stenosis distal to the anastomosis of the patent stented vein graft.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

BACKGROUND: Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. METHODS AND RESULTS: Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. CONCLUSIONS: High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.

Cardiac Catheterization↗

Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions.

Although intracoronary ultrasonography allows detailed tomographic imaging of the arterial wall, it fails to provide data on the structural architecture and longitudinal extent of arterial disease. This information is essential for decision making during therapeutic interventions. Three-dimensional reconstruction techniques offer visualization of the complex longitudinal architecture of atherosclerotic plaques in composite display. Progress in computer hardware and software technology have shortened the reconstruction process and reduced operator interaction considerably, generating three-dimensional images with delineation of mural anatomy and pathology. The indications for intravascular ultrasonography will grow as the technique offers the unique capability of providing ultrasonic histology of the arterial wall, and the need for a three-dimensional display format for comprehensive analysis is increasingly recognized. Consequently, three-dimensional imaging is being rapidly implemented in the catheterization laboratories for guidance of intracoronary interventions and detailed assessment of their results. However exciting the prospects may be, three-dimensional reconstructions at present remain partially artificial because the true spatial position of the imaging catheter tip is not recorded, and shifts in its location and curves of the arterial lumen result in pseudoreconstructions rather than true reconstructions. In this report, we address the principles of three-dimensional reconstruction with a critical review of its limitations. Potential solutions for refinement of this exciting imaging modality are presented.

Algorithms↗

Structural design, clinical experience, and current indications of the coronary Wallstent.

Based on data described previously, the wallstent is a versatile stent that, by virtue of its longitudinal flexibility and low profile, can be deployed with a high degree of success in complex lesions of both native coronary arteries and bypass vein grafts. This article discusses its structural design, the experimental studies of thrombogenicity and polymeric coating, early and late clinical experience with the wallstent, clinical evaluation of the less shortening wallstent, and the current indications of the coronary wallstent

Clinical Trials as Topic↗

Balloon dilatation of a bioprosthetic pulmonary valve.

A 37-year-old man with stenosis of a bioprosthetic pulmonary valve underwent percutaneous balloon valvoplasty. After the procedure the patient had moderate pulmonary regurgitation which has been well tolerated. The patient remains well with good functional capacity on follow-up at 2 years. Percutaneous balloon dilatation may be effective as a palliative procedure in the management of stenosis of a bioprosthetic valve in the pulmonary position.

Adult↗