Search PubMed⌕ Search

Biomedical subjects

D K Stevenson

Publications and source records attributed to D K Stevenson.

At least 127 records · Page 7Linked to original sources

Tomographic time-of-flight optical imaging device.

Time-resolved optical imaging has been used to image phantoms, animals, and humans, and offers the potential for the production of functional images of human tissues, such as the oxygenation of brain during stroke. We had previously reported a transmission scanner, and now give an early report on conversion to a rotational tomographic scanner with a non-parallel ray geometry similar to early CAT scanners. Initial scans show that 1) spatial imaging in turbid media using time-of-flight measurements, non-recursive algorithms, and standard tomographic geometry is possible, 2) separation of absorbance and scattering as an image is attainable, a key step in performing spatially-resolved chemometric analysis, 3) imaging of multiple objects buried within scattering material is feasible, demonstrating that equations derived for homogeneous media can be applied in at least some cases to inhomogeneous media such as tissue-like phantoms, and 4) imaging of brain pathology produces recognizable images with sufficient resolution for diagnostic decisions. We conclude that optical tomography is feasible for clinical use and that conversion of the present mechanically scanning device to a clinical scanner should be possible with retention of the current processing algorithms. Such a clinical scanner should ultimately be able to generate images in a few minutes with centimeter resolution at the center of living human brain.

Algorithms↗

Non-recursive linear algorithms for optical imaging in diffusive media.

Optical imaging has been used to image phantoms, animals, and humans. It offers the potential for the production of functional images of tissues, such as oxygenation of brain during stroke. Fast algorithms are needed to allow diagnostically useful images to be generated under realistic conditions, including the likelihood that transmission geometries will not be possible. We proposed a linear algorithm, while less than ideal, may allow rapid reconstruction of images and avoid the pitfalls of recursive, nonlinear solutions. Such techniques may also facilitate the use of varied but physiologic imaging geometries. We found that linear backprojection tomography is feasible for clinical use. Conversion of the present mechanically scanning device to a clinical scanner should be possible with retention of the current processing algorithms. Such a clinical scanner should ultimately be able to generate images in less than one minute with centimeter resolution at the center of living human brain.

Algorithms↗

Are multiple cesarean sections safe?

To assess the maternal and neonatal risk associated with high-order cesarean sections, a case-control study was carried out in two university affiliated maternity wards. The outcome of 154 pregnancies of women undergoing cesarean section for the 4th time or more was compared with 148 women sectioned for the 2nd or 3rd time and 132 women of similar age and parity after spontaneous birth. The main outcome measures were maternal operative and postoperative morbidity and neonatal prematurity and its complications, Apgar scores, and the need for intensive care. Women undergoing multiple (> or = 4) cesarean sections had significantly more intra-abdominal adhesions (P < 0.0001) than women sectioned for the 2nd or 3rd time. However, the time interval from incision to delivery and the total duration of operation were similar. The postoperative course was not adversely affected by multiple cesarean sections. A high incidence (16.2%) of preterm cesarean deliveries was noted in the study group. This was due to non-elective repeat cesarean delivery rather than to poor timing of scheduled cesarean sections. The significantly increased (P < 0.05) need for neonatal intensive care was explained by the higher occurrence of prematurity. Low Apgar scores (< or = 7) at 1 and 5 min were significantly (P < 0.01) related to multiple cesarean sections, even after controlling for the effect of gestational age. We conclude that multiple cesarean sections pose little risk for the mother, but may be associated with increased neonatal risk, attributed mainly to preterm non-elective cesarean sections.

Adult↗

Maternal transmission of human immunodeficiency virus-1.

The dramatic increase in the number of women of childbearing age infected with human immunodeficiency virus (HIV) has led to the revelation of another terrible consequence of the human immunodeficiency virus (HIV) pandemic; maternal transmission of HIV to the fetus. Over 90 per cent of the children who are infected with HIV contract the virus from their mother. Viral transmission may occur in utero, during labor when the newborn is exposed to maternal blood and body fluids or postnatally, mainly via breast-feeding. However, the risk of infection for a baby whose mother is an HIV carrier is not yet clear. The determination of the HIV status of the newborn remains a major diagnostic problem as the routine test, which detects antibodies to HIV, is of limited value in evaluating newborns. A summary of all of the large prospective long-term follow-up studies reported to date, shows an overall transmission rate of 22.4 per cent, with a 95 per cent confidence interval of 20.5 to 24.0 per cent. However, it is difficult to refer to the wide range of reported transmission rates, from 9.1 to 55.0 per cent, as they are confounded by the differing distribution of risk factors. The risk of maternal to newborn transmission must, therefore, be determined according to the specific characteristics of each parturient population.

Female↗

The effect of nutritional additives on anti-infective factors in human milk.

It has become a common practice to supplement human milk with a variety of additives to improve the nutritive content of the feeding for the premature infant. Twenty-two freshly frozen human milk samples were measured for lysozyme activity, total IgA, and specific IgA to Escherichia coli serotypes 01, 04, and 06. One mL aliquots were mixed with the following: 1 mL of Similac, Similac Special Care, Enfamil, Enfamil Premature Formula, and sterile water; 33 mL of Poly-Vi-Sol, 33 mg of Moducal, and 38 mg of breast-milk fortifier, and then reanalyzed. Significant decreases (41% to 74%) in lysozyme activity were seen with the addition of all formulas; breast-milk fortifier reduced activity by 19%, while no differences were seen with Moducal, sterile water, or Poly-Vi-Sol. No differences were seen in total IgA content, but some decreases were seen in specific IgA to E. coli serotypes 04 and 06. E. coli growth was determined after 3 1/2 hours of incubation at 37 degrees C after mixing. All cow-milk formulas enhanced E. coli growth; soy formulas and other additives preserved inhibition of bacterial growth. Nutritional additives can impair anti-infective properties of human milk, and such interplay should be considered in the decision on the feeding regimen of premature infants.

Adult↗

Direct relationship of fetal carboxyhemoglobin with hemolysis in alloimmunized pregnancies.

Because carbon monoxide (CO) is a byproduct of heme degradation and because placental diffusing capacity of CO is limited, we hypothesized that the concentration of CO transported in fetal blood as carboxyhemoglobin (HbCO) would correlate with the severity of fetal hemolytic disease. Fetal blood was obtained by cordocentesis and HbCO was measured by gas chromatography. The two primary study groups included control fetuses (n = 26) and fetuses of Coombs-positive mothers before in utero transfusion (n = 15). Compared with controls, fetuses with hemolytic disease had higher HbCO levels (0.0111 +/- 0.0014 versus 0.0159 +/- 0.0072 fraction of total Hb, mean +/- SD, p < 0.002). In contrast, HbCO levels in simultaneously sampled maternal blood samples were not different in the control and alloimmune groups [0.0110 +/- 0.0025 (n = 20) versus 0.0115 +/- 0.0021 (n = 11)]. There was a significant inverse correlation observed between fetal HbCO and Hb concentrations in the group with hemolytic disease (r = -0.73, p < 0.002) but not in controls. In fetuses with hemolytic disease, HbCO and bilirubin were highly correlated (r = 0.88, p < 0.0001). Data from four anemic fetuses who were Coombs negative, three of whom had no evidence of hemolysis, indicated normal HbCO and normal plasma bilirubin levels. A fourth fetus with anemia had viral sepsis and elevated HbCO and plasma bilirubin levels. We conclude that elevated HbCO levels detected in fetuses of nonsmoking mothers with erythrocyte alloimmunization are likely the result of accelerated hemolysis.

Bilirubin↗

Carboxyhemoglobin determined in neonatal blood with a CO-oximeter unaffected by fetal oxyhemoglobin.

Measurements of carboxyhemoglobin (COHb) for clinical purposes are routinely made with CO-oximeters. However, fetal hemoglobin (HbF) interferes with this spectrophotometric method. The manufacturer (Ciba Corning Diagnostics) of a new CO-oximeter (CCD 270) claims that COHb measurements with this instrument are insignificantly affected by HbF. We examined this claim through CO-oximeter analysis of cord blood/adult blood mixtures and compared the results with those obtained by gas chromatography (GC). We also studied the influence of oxygen and bilirubin concentrations. Measurements of COHb with CCD 270 were significantly lower than the GC measurements, but the differences were not clinically important. Linear regression analysis of HbF and COHb measurements (n = 68) showed significant correlation (P < 0.0001) between the two factors for the older CCD 2500 CO-oximeter (R2 = 0.56), but not for the CCD 270 (R2 = 0.06) or GC (R2 = 0.02). Bilirubin concentrations, which affected COHb measurements with CCD 2500, did not significantly affect CCD 270 measurements. We conclude that COHb measurements with CCD 270 CO-oximeter are not affected by HbF or bilirubin concentrations.

Bilirubin↗

Semiportable electrochemical instrument for determining carbon monoxide in breath.

Measurements of carbon monoxide (CO) in breath can be used for the diagnosis of hemolytic disease. A small, semiportable, easy-to-operate CO instrument was developed at Stanford University and tested at 12 Neonatal Research Network Centers of the National Institute of Child Health and Human Development. A syringe pump delivers 7.7 mL of sample per minute through an activate carbon filter to an electrochemical (EC) sensor having a sensitivity of 0.10 +/- 0.01 V per 1 microL/L CO in air. The electronically processed sensor signal is displayed on a digital multimeter. For a typical end-tidal CO measurement, corrected for inhaled CO, three 10- to 12-mL breath and room air samples are manually or mechanically collected and analyzed. CO determination in breath samples from 108 healthy, 1-day-old infants of nonsmoking mothers compared favorably with determinations by gas chromatography (GC), 1.3 +/- 0.8 vs 1.2 +/- 0.8 (mean +/- SD), respectively, with a regression equation of EC = 0.95 GC+0.13 (r2 = 0.98). The results demonstrate that the EC-CO instrument yields results that are comparable with those obtained by the more difficult to perform GC assay.

Breath Tests↗

Bilirubin production in healthy term infants as measured by carbon monoxide in breath.

To describe total bilirubin production in healthy term infants, we measured the end-tidal breath CO, corrected for ambient CO (ETCOc), with an automated sampler and electrochemical (EC) CO instrument. For infants of mothers with a negative Coombs' test, the ETCOc was 1.3 +/- 0.7 microL/L (n = 397) and the serum bilirubin on day 3 postpartum was 73 +/- 35 mg/L (n = 381). In contrast, the ETCOc for infants with ABO or Rh incompatibility, a positive direct Coombs' test, and bilirubin > 130 mg/L (n = 9) was significantly higher, 1.8 +/- 0.8 microL/L, than for those who had a positive Coombs' test result but whose bilirubin was < or = 130 mg/L (n = 12), 1.0 +/- 0.5 microL/L (P < 0.05). At 2 to 8 h postpartum seven term babies from mothers with insulin-dependent diabetes had ETCOc of 1.8 +/- 0.7 microL/L, significantly higher than that in the other term infants [1.3 +/- 0.7 microL/L (n = 390), P < 0.04]. Their bilirubin concentration at 72 +/- 12 h was also higher: 121 +/- 45 mg/L (n = 7) vs 73 +/- 34 mg/L (n = 374; P = 0.03). We conclude that ETCOc measurements may be helpful in understanding the mechanisms of jaundice in healthy term infants in a variety of conditions.

Asian↗

Sources of carbon monoxide (CO) in biological systems and applications of CO detection technologies.

Carbon monoxide is produced from a variety of sources in biological systems. Heme oxygenase and heme oxygenase-like activity is the predominant source in mammals, and may be equally important in plants and lower animals. The enzyme appears to be ubiquitous, highly conserved throughout phylogeny, and tightly regulated during development. This and other evidence suggests that heme oxygenase has an important physiological role, of which CO production may be a part. Other minor sources of CO include the oxidation of organic molecules. This includes the following: (1) auto-oxidation of phenols, flavenoids, and halomethanes; (2) photo-oxidation of organic compounds; and (3) lipid peroxidation of membrane lipids. No longer thought of as a waste product only, recent studies suggest that in the central nervous system cellular CO production can influence cGMP levels through effects on soluble guanylyl cyclase activity. Cellular CO production may also be linked to cell-cell interactions, and may be important in the cell's response to environmental changes. Whether CO will have a place similar to nitric oxide in cellular metabolism is still unclear, but it is apparent that these metabolic relationships will become increasingly complex. Cellular heme oxygenase activity results in the equimolar production of CO and bilirubin for each molecule of heme degraded. The CO thus formed diffuses into the blood, is carried via hemoglobin, and is excreted in the lungs. Therefore, CO production can be assessed clinically by measuring the rate of total body CO excretion, blood COHb levels, and end-tidal CO concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Enhancement of heme oxygenase expression and activity in A431 squamous carcinoma multicellular tumor spheroids.

We have investigated the effects of the growth of A431 human squamous carcinoma cells as three-dimensional aggregates (multicellular tumor spheroids) on the expression and enzyme activity of heme oxygenase (HO). We demonstrate that A431 squamous carcinoma cells grown as day 4 spheroids selectively increase the expression of heme oxygenase 1 (HO-1), caused, directly or indirectly, by three-dimensional cell-cell contact effects. Steady-state levels of both mRNA and protein are significantly enhanced in spheroids compared with day 4 monolayers (approximately 13-fold). Because of the similarity of apparent half-lives between monolayers (2.7 h) and spheroids (2.1 h), it appears that the increases are caused at least partly by altered transcriptional rates. Total HO enzyme activity, measured by carbon monoxide production, is also up-regulated (2.6-fold) in spheroids, compared to that in monolayers. This increase indicates that the up-regulation in HO-1 protein expression corresponds to an increase in functional enzyme levels. We propose that HO may play a more complex role in cellular metabolism than would be evident from studies using two-dimensional monolayer cultures.

Blotting, Northern↗

Optical time-of-flight and absorbance imaging of biologic media.

Imaging the interior of living bodies with light may assist in the diagnosis and treatment of a number of clinical problems, which include the early detection of tumors and hypoxic cerebral injury. An existing picosecond time-of-flight and absorbance (TOFA) optical system has been used to image a model biologic system and a rat. Model measurements confirmed TOFA principles in systems with a high degree of photon scattering; rat images, which were constructed from the variable time delays experienced by a fixed fraction of early-arriving transmitted photons, revealed identifiable internal structure. A combination of light-based quantitative measurement and TOFA localization may have applications in continuous, noninvasive monitoring for structural imaging and spatial chemometric analysis in humans.

Animals↗