Search PubMed⌕ Search

Biomedical subjects

D K Blood

Publications and source records attributed to D K Blood.

23 records · Page 2Linked to original sources

Cardiac sinus node dysfunction during lithium treatment.

Lithium treatment has been associated with a wide range of cardiac complications. The authors report three additional cases of cardiac sinus node dysfunction due to lithium. Two of the three cases were documented to be lithium dependent by the use of Holter monitoring of cardiac rhythm. On the basis of this finding as well as other reports in the literature the authors recommend careful monitoring of the pulse of patients taking lithium as well as ECG monitoring of patients who are over the age of 50 or who have a history of cardiac disease.

Aged↗

Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction.

Thallium-201 myocardial perfusion scintigraphy was performed after exercise, 4 hours after exercise (redistribution) and after a separate rest injection in 87 patients undergoing coronary arteriography. Significant coronary lesions were present in 62 of the patients. Interpretation of the rest and redistribution scintiscans was the same in 69 patients, 45 of whom had coronary artery disease (CAD). In 16 of the 17 patients with CAD and differing interpretations, defects were present on redistribution scintiscans but not on rest scintiscans; 11 of these patients had evidence of prior transmural myocardial infarction and the other five had an occluded coronary artery supplying the region of the defect. Redistribution scintiscans were more sensitive than rest scintiscans for the detection of prior myocardial infarction (93% vs 54%; P less than 0.01). The increased sensitivity was confined to the detection of prior inferior myocardial infarctions. In 36 of 38 patients with persistent perfusion defects on 4-hour redistribution scintiscans, either a prior infarction or an occluded coronary vessel was present. Exercise scintiscans were compared with rest scintiscans or with redistribution scintiscans for the detection of CAD. The sensitivity was not significantly different with either technique (90% and 89%, respectively), but both scintigraphic techniques were more sensitive than exercise electrocardiography (66%, P less than 0.01). These data demonstrate that redistribution thallium-201 scintiscans may be substituted for conventional rest scintiscans, resulting in reduced cost and radiation exposure to the patient.

Adult↗

Feasibility of a two-dimensional echocardiographic method for the clinical assessment of right ventricular volume and function in children.

The relative ease of acquisition and safety of two-dimensional echocardiography has established it as the mainstay for routine cardiac imaging. Translation of imaging data into useful quantitative information, however, requires fitting the ventricle to a specific geometric model. Because of its complex shape and anterior position, many attempts at right ventricular quantitation by two-dimensional echocardiography have been criticized as impractical and not reproducible. A simple method incorporating subcostal and apical imaging was introduced in 1984. This approach appeared to combine accuracy and practicability but was never validated in a clinical setting because of the difficulties of subcostal imaging in adults. This study assessed the feasibility and accuracy of this technique in the pediatric population. Results of volume comparison to values derived by magnetic resonance imaging were r = 0.96, standard error of the estimate (SEE) = 19.3 ml, and mean difference = 15 +/- 19.4 ml and r = 0.97, SEE = 12.3 ml, and bias = 5 +/- 11.8 ml for diastolic and systolic volumes, respectively. Comparison of estimates of ejection fraction with magnetic resonance imaging demonstrated r = 0.90, SEE = 5.9%, and bias = 3% +/- 5.7%. Interobserver and intraobserver variability was 9.9% and 8.2%, respectively, for systolic volumes and 11.5% and 8.9%, respectively, for diastolic volumes. Evaluation of right ventricular size and function by this approach is comparable to determinations by magnetic resonance imaging and may be clinically useful in the management of pediatric patients.

Adolescent↗

Failure of right precordial electrocardiography during stress testing to identify coronary artery disease.

BACKGROUND: It has been reported that the use of right precordial leads results in the same diagnostic accuracy as thallium-201 exercise scintigraphy for the detection of coronary artery disease (CAD). The aim of this study was to evaluate the utility of right precordial leads in the detection of CAD. METHODS AND RESULTS: We evaluated 900 consecutive patients (514 men, 386 women) ranging in age from 39 to 84 years (mean +/- SD, 64 +/- 11 years). Seven hundred forty patients underwent treadmill exercise testing, and 160 underwent pharmacologic stress testing for the diagnosis of chest pain or dyspnea. All received either Tl-201 or technetium-99m sestamibi during stress. During stress testing, the ECG was recorded every minute with 12 limb and left precordial leads and 3 right precordial leads (V(3)R, V(4)R, and V(5)R). The electrocardiogram was considered positive when the ST segment was either elevated or depressed by at least 0.1 mV at 80 ms after the J point, and results were also compared with single photon emission computed tomography myocardial perfusion imaging results. Of the 900 patients, 158 had significant positive changes in the limb or left precordial leads. Only 4 patients had positive changes in the right precordial leads (Fisher exact test, P <.001). Of the patients who had positive electrocardiographic changes, 95 (60%) had abnormal myocardial perfusion scans, with 91 in patients with normal right precordial leads. All 4 patients with ischemic changes in the right precordial leads had abnormal scans, but the left leads were also positive. Three hundred seventy-three of 900 patients (41%) had abnormal scans with no electrocardiographic evidence of ischemia. CONCLUSIONS: Our experience is far different than that published and suggests that the use of right precordial leads during stress testing fails to provide the same diagnostic accuracy as either the standard left-sided electrocardiography or myocardial perfusion imaging for the detection of CAD.

Adult↗

Myocardial perfusion scintigraphy in heart transplant recipients with and without allograft atherosclerosis: a comparison of thallium-201 and technetium 99m sestamibi.

Our objectives were to assess the comparative value of thallium-201 and technetium 99m sestamibi for the detection of cardiac allograft atherosclerosis and the left ventricular ejection fraction response to exercise in heart transplant recipients with and without allograft atherosclerosis. Allograft atherosclerosis is the critical factor limiting long-term survival in heart transplant recipients. Annual coronary angiography is invasive and expensive. A noninvasive test to detect allograft atherosclerosis would be clinically useful. Treadmill exercise testing followed by myocardial perfusion single-photon computed tomographic imaging was performed in 25 heart transplant recipients. All patients underwent coronary angiography. Group 1 (13 patients) had angiographic coronary artery disease; group 2 (12 patients) did not. Eighteen patients underwent two exercise tests to equivalent work loads with thallium-201 and technetium 99m sestamibi; seven patients underwent only thallium-201 imaging. First-pass left ventricular ejection fraction was measured during injection of technetium 99m sestamibi. In group 1, 10 of 13 patients had abnormal thallium-201 scans. There was no significant difference in the number of patients who had abnormal thallium-201 (7/10) and technetium 99m sestamibi scans (6/10). Fifty-two percent (12/23) of discordantly scored segments were reversible on thallium-201 and fixed on technetium 99m sestamibi imaging compared with the opposite (0%; 0/23) (p < 0.01). All patients in group 2 had normal perfusion scans. There were no false-positive scans.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗