Search PubMed⌕ Search

Biomedical subjects

D J Sahn

Publications and source records attributed to D J Sahn.

At least 145 records · Page 8Linked to original sources

Correlation of patent ductus arteriosus shunting with plasma atrial natriuretic factor concentration in preterm infants with respiratory distress syndrome.

The concentration of plasma atrial natriuretic factor (ANF) and the mechanism for its secretion were investigated in 17 preterm infants with respiratory distress. Their mean gestational age was 29 wk and wt 1250 g. The infants were followed during the first week of life by sequential Doppler ultrasound studies. Ductal openness versus closure and amount of ductal flow were correlated with plasma ANF concentrations. In a subset of 10 infants, sequential Doppler color flow mapping was used to quantify the ductal flow. During the first 72 h, plasma ANF was high, 361 pg/mL; it decreased to 96 pg/mL by the end of the 1st wk. The ANF level was significantly higher when the ductus was open than closed (393 versus 123 pg/mL, p less than 0.05). In patients with open ductus and bidirectional foramen ovale shunting (n = 3) ANF was 567 pg/mL and in those with left-to-right shunt 355 pg/mL (n 15, NS). The left atrial size, i.e. the left atrial to aortic root ratio, correlated with the amount of ductal shunting (r = 0.63, p less than 0.01) and with ANF concentration (r = 0.46, p less than 0.02). The correlation of ANF values and the magnitude of left-to-right ductal shunting assessed by color flow mapping was highly significant (r = 0.66, p less than 0.001). In these patients, the elevation of ANF is reflective of ductal flow.

Age Factors↗

Instantaneous transmitral flow using Doppler and M-mode echocardiography: comparison with radionuclide ventriculography.

To improve the accuracy of Doppler echocardiographic indices of left ventricular filling, we derived two indices of instantaneous transmitral flow with the use of Doppler velocities and M-mode echocardiography. These indices were calculated from the product of pulsed Doppler mitral velocities and either the excursion of the anterior mitral leaflet or the separation of both mitral leaflets as measures of the changing mitral orifice area. The derived flow indices and the mitral velocities alone were compared to left ventricular filling as determined by radionuclide ventriculography in 24 patients. When compared as areas under the matched decile divisions of the derived filling sequences by linear regression analysis, the relationship for combined Doppler and M-mode versus radionuclide left ventricular filling was closer to the line of identity (slope = 0.98 and 0.94 using the anterior mitral leaflet and both mitral leaflets, respectively, both p = NS versus the line of identity) than was the relationship for mitral velocities alone versus radionuclide left ventricular filling (slope = 0.74, p less than 0.05 versus the line of identity). The instantaneous mitral volume flow indices more closely resemble the time course and shape of radionuclide left ventricular filling curves than do mitral velocities alone, and the application of these indices should assist the quantitative description by Doppler echocardiography of left ventricular filling.

Aged↗

Doppler color flow mapping studies of jet formation and spatial orientation in obstructive hypertrophic cardiomyopathy.

To help clarify the mechanism of outflow tract obstruction and systolic anterior motion of the anterior leaflet of the mitral valve and their relation to the geometry of the left ventricle, we studied left ventricular outflow tract flow in 20 patients with hypertrophic cardiomyopathy (HCM) using two-dimensional Doppler flow mapping. We compared our results with outflow tract flow in 10 patients with isolated valvular aortic stenosis, (AS) and with those in 10 healthy volunteers. In HCM, a 94- to 145-degree angle (mean 111.4 +/- 11.9 degrees) developed between the direction of left ventricular outflow tract flow acceleration and aortic valve outflow, resulting in posterolaterally directed left ventricular outflow jets. The angle of the outflow jet and the peak velocity of the jet measured with continuous wave Doppler (as an indicator of the severity of obstruction) correlated well (r = -0.81, SEE = 7.8 degrees). Jet narrowing during ejection measured just proximal to the point of systolic anterior motion was 42 +/- 11% in HCM and was weakly correlated with peak jet velocity (r = 0.61, SEE = 8.9 degrees). Aliasing of left ventricular outflow occurred proximal to systolic anterior motion of the mitral valve, and color M-mode demonstrated temporal and spatial flow acceleration proximal to systolic anterior motion, providing evidence for obstruction at that site. In AS, left ventricular outflow tract jets were more parallel to the axis of aortic outflow (129 to 153 degree, 138.4 +/- 8.1 degrees). Jet narrowing was only 8 +/- 5% compared to HCM (both p less than 0.05), and flow acceleration occurred proximal to the stenotic valve.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Human fetal tricuspid and mitral deceleration time: changes with normal pregnancy and intrauterine growth retardation.

Studies in instrumented adults have shown an association between Doppler echocardiography-derived atrioventricular valve deceleration times and ventricular function. To determine how gestational age affects deceleration time in the tricuspid and mitral valve, pulsed Doppler ultrasonographic examinations were performed in 54 normal human fetuses. In addition, 26 fetuses with growth retardation and the absence of end-diastolic Doppler velocities in the umbilical artery were examined. Measurements were obtained from strip chart recordings; between three and five beats were used to obtain an average heart rate, ratio of peak velocity at atrial contraction to peak velocity in early diastole, and deceleration time in early diastole. Deceleration times increased during gestation from 86 +/- 27 to 116 +/- 18 msec in the tricuspid valve and from 98 +/- 25 to 132 +/- 21 msec in the mitral valve. Fetuses with growth retardation and the absence of end-diastolic Doppler velocities in the umbilical artery had longer deceleration times than those of normal fetuses (p less than 0.01). The increase in deceleration time across both atrioventricular valves in normal fetuses may be related to heart rate, an increased rate of ventricular relaxation, or an increase in ventricular compliance. The fetuses with intrauterine growth retardation and the absence of end-diastolic velocities in the umbilical artery have abnormally increased deceleration times; in the abnormal fetus this may be a result of impaired ventricular relaxation or decreased ventricular compliance.

Blood Flow Velocity↗

Experimental ductus arteriosus: the relationships of atrial pressure, dilatation and flow with ANF secretion.

The design of the study was to determine whether an increased blood flow as seen in shunt lesions could serve as a stimulus for the secretion of atrial natriuretic factor (ANF). Since atrial pressure, flow, and dilatation are closely related, an experimental ductus arteriosus model was utilized, in which acute changes of flow are assumed not to dilate the left atrium. In six dogs, a Dacron graft was constructed between the main pulmonary artery and the innominate artery. Constricting and releasing the tape around the graft adjusted the amount of "ductal" shunting. The total pulmonary flow and the shunt flow were measured by electromagnetic-flow transducers around the aortic root and around the graft. Plasma ANF concentration was measured from both cardiac atria. The size of the left atrium was determined from echocardiographic measurements made from a short-axis view. The total pulmonary flow varied between 1.2 and 5.8 1/min. The highest measured ANF was 396 pg/ml, and this was from the left atrium when the pressure was 18 mmHg, the highest left atrial pressure recorded. The highest right atrial pressure (5 mmHg) also correlated with the highest right-atrial level of ANF (366 pg/ml). The right atrial pressure had a significant correlation with plasma ANF concentration (R = 0.43, p less than 0.05). Pulmonary flow and plasma ANF concentration did not correlate; neither did left atrial size and ANF levels in 16 flow states where the size was measured. In the absence of atrial dilatation there was minimal stimulus for ANF secretion. A transient increase of left atrial pressure, without a concomitant significant atrial dilatation, did not serve as a significant stimulus for ANF secretion.

Animals↗

Elucidation of the natural history of ventricular septal defects by serial Doppler color flow mapping studies.

Two-dimensional echocardiography has provided information to aid in the diagnosis and management of infants with ventricular septal defect, but its inability to resolve very small ventricular septal defects and problems with defining ventricular septal defect orifice size (because of overlying muscle or tricuspid tissue) have made it unsuitable as a standard for defining the natural history of ventricular septal defect. In this study, 114 serial two-dimensional Doppler color flow mapping studies were performed to define ventricular septal defect anatomy, location and color flow diameter as an indicator of shunt size in 66 patients (over a 40 month period). Twenty-five patients first studied at 6 months of age (mean age at most recent study 15.9 months) had congestive heart failure and 41 (mean age 45 months) did not. In the congestive heart failure group, there were 24 perimembranous and 1 muscular ventricular septal defect and aneurysm formation was present in 17. Mean (+/- SD) color flow diameter was 8.2 +/- 1.9 mm and color flow diameter/aortic root diameter ratio was 0.63. In the 30 patients who underwent cardiac catheterization, color flow diameter bore a close relation to angiographic diameter (r = 0.96) and pulmonary/systemic flow ratio (Qp/Qs) (r = 0.88). In the patients with congestive heart failure, 4 of the 25 ventricular septal defects, all with aneurysm present or positioned adjacent to the tricuspid valve, became smaller but none closed. Of the 41 patients without congestive heart failure, 21 had a perimembranous defect (15 with aneurysm), 18 had a muscular ventricular septal defect and 2 had a supracristal ventricular septal defect.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Doppler color flow mapping of simulated in vitro regurgitant jets: evaluation of the effects of orifice size and hemodynamic variables.

The spatial distribution of simulated regurgitant jets imaged by Doppler color flow mapping was evaluated under constant flow and pulsatile flow conditions. Jets were simulated through latex tubings of 3.2, 4.8, 6.35 and 7.9 mm by varying flow rates from 137 to 1,260 cc/min. Color jet area was linearly related to flow rate at each orifice (r = 0.96, SEE = 3.4; r = 0.99, SEE = 1.6; r = 0.97, SEE = 2.3; r = 0.97, SEE = 3.2, respectively), but significantly higher flow rates were required to maintain the same maximal spatial distribution of the jet at the larger regurgitant orifices. Constant flow jets were also simulated through needle orifices of 0.2, 0.5 and 1 mm, with a known total volume (5 cc) injected at varying flow rates and with differing absolute volumes injected at the same flow rate (0.2, 1.0 and 2.0 cc/s, respectively). Again, maximal color jet area was linearly related to flow rate at each orifice (r = 0.97, SEE = 2.3; r = 0.97, SEE = 2.4; r = 0.92, SEE = 3.9, respectively), but was not related to the absolute volume of regurgitation. Color encoding of regurgitant jets on Doppler color flow maps was demonstrated to be highly dependent on velocity and, hence, driving pressure, such that color encoding was obtained from a constant flow jet injected at a velocity of 4 m/s through an orifice of 0.04 mm diameter with flow rates as low as 0.008 cc/s. Mitral regurgitant jets were also simulated in a physiologic in vitro pulsatile flow model through three prosthetic valves with known regurgitant orifice sizes (0.2, 0.6 and 2.0 mm2). For each regurgitant orifice size, color jet area at each was linearly related to a regurgitant pressure drop (r = 0.98, SEE = 0.15; r = 0.97, SEE = 0.20; r = 0.97, SEE = 0.23, respectively), regurgitant stroke volume (r = 0.77, SEE = 0.55; r = 0.94, SEE = 0.30; r = 0.91, SEE = 0.41, respectively) and peak regurgitant flow rate (r = 0.98, SEE = 0.16; r = 0.97, SEE = 0.21; r = 0.93, SEE = 0.37, respectively), but the spatial distribution of the regurgitant jets was most highly dependent on the regurgitant pressure drop. Jet kinetic energy calculated from the summation of the individual pixel intensities integrated over the jet area was closely related to driving pressure (r = 0.84), but integration of the power mode area times pixel intensities provided the best estimation of regurgitant stroke volume (r = 0.80).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Sources of variability for Doppler color flow mapping of regurgitant jets in an animal model of mitral regurgitation.

To determine whether Doppler color flow mapping could be used to quantify changing levels of regurgitant flow and define the technical variables that influence the size of color flow images of regurgitant jets, nine stable hemodynamic states of mitral insufficiency were studied in four open chest sheep with regurgitant orifices of known size. The magnitude of mitral regurgitation was altered by phenylephrine infusion. Several technical variables, including the type of color flow instrument (Irex Aloka 880 versus Toshiba SSH65A), transducer frequency, pulse repetition frequency and gain level, were studied. Significant increases in the color flow area, but not in color jet width measurements, were seen after phenylephrine infusion for each regurgitant orifice. For matched levels of mitral regurgitation, an increase in gain resulted in a 125% increase in color flow area. An increase in the pulse repetition and transducer frequencies resulted in a 36% reduction and a 28% increase in color flow area, respectively. Jet area for matched regurgitant volumes was larger on the Toshiba compared with the Aloka instrument (5.2 +/- 3.1 versus 3.2 +/- 1.2 cm2, p less than 0.05). Color flow imaging of mitral regurgitant jets is dependent on various technical factors and the magnitude of regurgitation. Once these are standardized for a given patient, the measurement of color flow jet area may provide a means of making serial estimates of the severity of mitral insufficiency.

Animals↗

Factors influencing the structure and shape of stenotic and regurgitant jets: an in vitro investigation using Doppler color flow mapping and optical flow visualization.

To evaluate factors influencing the structure and shape of stenotic and regurgitant jets, Doppler color flow mapping and optical flow visualization studies were performed with use of a syringe model with a constant rate of ejection to simulate jets of valvular regurgitation and a pulsatile flow model of the right heart chambers to simulate jets of mild, moderate and severe valvular pulmonary stenosis. Ink-(0 to 40%) glycerol-water jets (viscosity 1 to 3.5 centiPoise) were produced by injecting the fluid at a constant rate into a 10 gallon rectangular reservoir of the same still fluid through 1.4 and 3.4 mm needles. The Doppler color flow scanners imaged the laminar jet length within 3 mm of actual jet length (2 to 6 cm) and the jet width within 2 to 3 mm of the actual jet width. Jet flows with Reynolds numbers ranging from 230 to 1,200 injected into still fluid yielded jet length/width ratios that decreased with increasing Reynolds numbers and leveled off to a length/width ratio of 5-6:1 at a Reynolds number near 600. When the fluid reservoir was swirled to better mimic the effect of flow entering the same cardiac chamber from a second source, the jets showed diminution of the jet length/width ratio and a clearly defined zone of turbulence. Studies of the pulsatile flow model were performed at cardiac outputs of 1 to 6 liters/min for the normal and each stenotic valve. Mild stenosis had an orifice area of 2.8 cm2, moderate stenosis an area of 1.0 cm2 and severe stenosis an area of 0.5 cm2. Laminar jet length represented the length of the total jet, which had a symmetric width and was measured from the valve opening to a region where the jet exhibited a spray effect. Laminar jet lengths (0.2 to 1.1 cm) were imaged by Doppler color flow mapping and optical visualization only in the moderate and severely stenotic valves and only at flows less than or equal to 3 liters/min (mean Reynolds numbers less than or equal to 3,470). Beyond this flow rate the jets exhibited a spray effect. Laminar jet length/width ratio approached unity with an increased amount of valvular stenosis and higher flow volumes (cardiac output). Proximal aliasing was present in each valve studied. the length of aliasing (0 to 3.2 cm) proximal to the valve was longer with increased flow rates and increased amounts of stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Blood Flow Velocity↗

Spatial velocity distribution and acceleration in serial subvalve tunnel and valvular obstructions: an in vitro study using Doppler color flow mapping.

To evaluate the spatial distribution of flow velocities, turbulence and spatial acceleration in serial tunnel-valve obstruction, Doppler color flow mapping was performed in a pulsatile flow model with a tunnel obstruction (1.0 or 1.5 cm2) inserted at 2, 20 and 40 mm proximal to a mildly stenotic bioprosthetic valve studied at flow rates of 1, 2.7 and 4.9 liters/min. Measured pressure gradients were consistently higher across the tunnel (mean +/- SD 32.7 +/- 26.5 mm Hg) than across the tunnel plus valve (28.8 +/- 26.9 mm Hg, p less than 0.01). Doppler color flow map images were analyzed using a Sony RGB video-digitizing computer, providing numerical velocity assignments for the blue, red and green (variance) pixel components to allow the flow maps to be constructed into digital velocity maps and pseudo three-dimensional velocity maps. The maximal velocity stream extended distal to the tunnel (2 to 19 mm), and the length of this extension correlated well with the pressure gradient measured across the tunnel (r = 0.89), with a rapidly decelerating and turbulent spray area seen immediately distal to the valve. Pressure gradient calculated from the maximal velocity derived from the color flow map, which could only be estimated from the velocity maps for the 1.5 cm2 tunnel, correlated well with the gradient measured across the tunnel (18.0 +/- 14.1 versus 19.2 +/- 14.5 mm Hg, respectively, r = 0.98). Acceleration was seen proximal to both tunnels.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

A new method for estimating left ventricular dP/dt by continuous wave Doppler-echocardiography. Validation studies at cardiac catheterization.

In this study, we explored the use of continuous wave Doppler-echocardiography guided by color Doppler flow-mapping as a method for noninvasively calculating the rate of pressure rise (RPR) in the left ventricle. Continuous wave Doppler determination of the velocities in mitral regurgitant jets allows calculation of instantaneous pressure gradients between the left ventricle and the left atrium. Left atrial pressure variations in early systole can be considered negligible; therefore, the rising segment of the mitral regurgitation velocity curve should reflect left ventricular pressure increase. We studied 50 patients (mean age, 51 years; range, 25-66 years) in normal sinus rhythm with color Doppler-proven mitral regurgitation and compared the Doppler-derived left ventricular RPR with peak dP/dt obtained at cardiac catheterization. Doppler studies were performed simultaneously with cardiac catheterization in 11 patients and immediately before in the remaining cases. Two points were arbitrarily selected on the steepest rising segment of the continuous wave mitral regurgitation velocity curve (point A, 1 m/sec, point B, 3 m/sec), and the time interval (t) between them was measured. Following the Bernoulli relation, the pressure rise between points A and B is 32 mm Hg (4vB2-4vA2) and the RPR is 32 mm Hg/t. Results showed a linear correlation between the Doppler RPR and peak dP/dt (r = 0.87, SEE = 316 mm Hg/sec). The RPR in the left ventricle can be derived from the continuous wave Doppler mitral regurgitation velocity curve.

Blood Flow Velocity↗

Closure of the ductus arteriosus and mechanics of breathing in preterm infants after surfactant replacement therapy.

Treatment of premature infants with exogenous surfactant is thought to increase the incidence of the patent ductus arteriosus (PDA) due to improved mechanics of breathing and the resultant reduced pulmonary vascular resistance. As part of a prospective, blinded, controlled study of human amniotic fluid-derived surfactant, we assessed the time of closure of the PDA, defined by Doppler echocardiographic studies, performed at 6-h intervals, and the mechanics of breathing at 6, 18, and 30 h of age in 61 infants (gestational age, 25-29 wk, and birth wt, 450-1580 g). All infants had respiratory distress syndrome as confirmed by immature surfactant phospholipid profiles determined on either amniotic fluid and/or tracheal aspirate analysis, and chest radiograph, and all had a PDA at 6 h of age. Surfactant treatment was associated with more frequent clinically determined need for treatment of the PDA, but did not prolong the patency of the ductus in infants with spontaneous closure or in those requiring treatment with indomethacin. Infants with spontaneous closure of the PDA had significantly higher dynamic lung compliances and lower oxygen requirements and were treated with lower mean airway pressures than those requiring PDA treatment, although their arterial blood gas status was the same. The dynamic lung compliance of infants with right to left ductal shunting was significantly lower than those with left to right shunting at 6 and 18 h but was not different thereafter. This study suggests that the maturity of the ductus arteriosus, reflected by its tendency to close spontaneously, parallels the maturity of the lungs, reflected by their mechanical stability, and that ductal closing is not significantly altered by surfactant therapy.

Clinical Trials as Topic↗

Cardiac function, substrate utilization, and myocardial energy metabolism studied with 31-P NMR spectroscopy during acute hypoglycemia and hyperketonemia.

Whether severe hypoglycemia alone or in combination with hyperketonemia might cause deterioration of cardiac function has been controversial. Therefore, the influence of acute hypoglycemia (mean 33 mg/dL) with and without hyperketonemia (mean 1.3 and 3.3 mM) on cardiac function, substrate utilization, and myocardial high energy phosphate levels was studied in 10 mongrel dogs. After 45 min of hypoglycemia, mean aortic pressure, total peripheral resistance, and myocardial oxygen consumption had increased significantly, but other hemodynamic parameters and regional myocardial function had not changed. Additional infusion of 3-hydroxybutyrate did not affect hemodynamic variables significantly. During both metabolic interventions in vivo phosphorus-31 nuclear magnetic resonance spectroscopy showed stable levels of myocardial phosphocreatinine, ATP, as well as the phosphocreatinine/ATP (3.0-3.2) ratio. Biochemical measurements revealed that hyperketonemia led to significant alterations in arterial concentrations and arteriocoronary venous differences of selected citric acid cycle intermediates, thus confirming previous reports which suggested a blockade of the 2-oxoglutarate-dehydrogenase reaction induced by ketone body oxidation. However, despite this blockade, the energy supply to the heart was not impaired as shown by normal nuclear magnetic resonance spectroscopy and cardiac performance. It is speculated, that the blockade might be due to an enhanced NADH/NAD ratio.

Adenosine Triphosphate↗

Applications of color flow mapping in pediatric cardiology.

Our approach to the application of flow mapping in pediatric cardiology has been to attempt to define, in technical terms, the relationship between the nature of the imaging technology and the nature of the questions to be asked about flow. The late William Rashkind, to whom this issue of Cardiology Clinics is dedicated, set an important example to me in the early stages of my training about the understanding of defined clinical problems and the development of technologies to adapt to those specific problems. In this way, using his ingenuity, his energy, and his love both of good times and difficult problems, he pioneered new and unexplored areas of our field and set an important example for us to follow. The applications of color flow mapping, a new and rapidly evolving technology, are still in their infancy, and it behooves the pediatric cardiologist to evolve in his expertise along with the evolution of the instrumentation toward new and important impacts which these imaging methods will have in the health care of children with heart disease.

Aortic Coarctation↗

Calculating cardiac output from transmitral volume flow using Doppler and M-mode echocardiography.

To simplify transmitral volume flow determination by Doppler echocardiography, a formula for calculating mean mitral valve orifice area using M-mode echocardiography without any 2-dimensional measurements was developed and evaluated in this study. The maximal mitral orifice area was assumed to be circular and its diameter was calculated from the maximal M-mode mitral leaflet separation. The maximal area was multiplied by the mean to maximal anterior mitral leaflet excursion ratio to correct for phasic changes in flow orifice area during ventricular filling. This measurement had a high correlation (r = 0.97, standard error of the estimate + 0.26 cm2) with mean mitral valve orifice area calculated from frame-by-frame analysis of short-axis 2-dimensional echoes in a select group of 10 normal volunteers and 10 patients with cardiomyopathy who had very high quality images of the mitral valve leaflet tips. Cardiac output calculated using the new method for orifice area estimation combined with apex view mitral valve Doppler velocities was then validated in 48 consecutive patients undergoing thermodilution cardiac output determinations with a close correlation between Doppler and thermodilution cardiac output (2.3 to 6.1 liter/min, r = 0.93, standard error of the estimate = 362 ml). The correlation improved when 12 patients with mild mitral insufficiency were excluded (r = 0.95). The M-mode echocardiogram-derived mitral valve orifice method combined with Doppler mitral valve velocities is accurate, easy to perform, has a high success rate and should increase the applicability of Doppler echocardiography for estimation of cardiac output.

Adult↗