Search PubMed⌕ Search

Biomedical subjects

D J Sahn

Publications and source records attributed to D J Sahn.

At least 73 records · Page 4Linked to original sources

Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta.

BACKGROUND: Impaired aortic pulsatility has been demonstrated by angiography in children and in studies of experimental animals with coarctation of the aorta. OBJECTIVES: The purpose of this study was to assess regional aortic stiffness, distensibility, and compliance before and after balloon dilation in patients with coarctation of the aorta. METHODS AND RESULTS: Intravascular ultrasound examination was performed in 13 pediatric patients with the diagnosis of coarctation of the aorta to yield aortic diameter. Area transverse sections at both systolic and diastolic period were measured at three aortic levels: the proximal, distal, and coarctation segments. Balloon dilation was also performed in eight of 13 patients. By using pressures measured in the same areas, an aortic stiffness index (beta) was calculated as In(Ps/Pd)/(Ds-Dd), where In is natural logarithm, Ps is systolic pressure, Pd is diastolic pressure, Ds is systolic diameter, and Dd is diastolic diameter. Aortic distensibility and an estimation of aortic compliance were also calculated. The beta stiffness index of the coarctation and the proximal segments of the aorta were significantly greater than that of the distal segment of the aorta (p < 0.01). The aortic wall stiffness beta index did not acutely change after successful balloon dilation, but the distensibility and compliance of distal aorta were nonetheless significantly decreased after balloon dilation (p < 0.01, p < 0.05) as a function of changes of pulsatility of flow. CONCLUSIONS: Abnormal proximal aortic stiffness may be a strong contributing factor that promotes the genesis of hypertension in patients with coarctation even after successful repair or balloon angioplasty.

Adolescent↗

Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation.

OBJECTIVES: The aim of the present study was to quantitate aortic regurgitant volume and regurgitant fraction in a chronic animal model with surgically created aortic regurgitation using a new semiautomated color Doppler flow calculation method. BACKGROUND: The conventional noninvasive methods for evaluating the severity of aortic regurgitation have not been accepted widely nor compared with truly quantitative reference standards. METHODS: Eight to 20 weeks after aortic regurgitation was surgically induced in six sheep, a total of 22 hemodynamic states were studied. Electromagnetic flow probes and meters provided reference flow data. Epicardial color Doppler echocardiographic studies were performed to image left ventricular outflow tract forward and aortic regurgitant blood flows. The new method digitally integrated spatial and temporal color flow velocity data for left ventricular outflow tract forward flow and ascending aortic regurgitant flow. The pulsed Doppler method using the velocity-time integral was also used to obtain regurgitant volumes and regurgitant fractions. RESULTS: Regurgitant volumes and regurgitant fractions by the new method agreed well with those obtained electromagnetically, whereas the pulsed Doppler method overestimated these reference data (mean [+/-SD] difference 0.23 +/- 2.9 ml vs. 11 +/- 5.8 ml, p < 0.0001 for regurgitant volume; mean difference 1.2 +/- 7.6% vs. 19 +/- 13%, p < 0.0001 for regurgitant fraction). CONCLUSIONS: This animal study, using strictly quantified aortic regurgitant volumes, demonstrated that the digital color Doppler method provides accurate aortic regurgitant volumes and regurgitant fractions without cumbersome measurements.

Animals↗

Two-dimensional echocardiographic evaluation of ventricular systolic function in human fetuses with ductal constriction.

Ventricular systolic function was assessed in fetuses, 18 with and 18 without constriction of the ductus arteriosus by serial two-dimensional and Doppler echocardiographic studies. Ductal constriction was defined as maximum systolic velocity of > 140 cm/s and diastolic flow velocity of > 30 cm/s. Ventricular end-diastolic and end-systolic areas were measured from a four-chamber view and area shortening fraction (SF) was calculated: area SF = (area in end-diastole--area in end-systole)/area in end-diastole. In fetuses with ductal constriction, right ventricular end-diastolic and end-systolic areas were significantly increased and right ventricular area SF decreased significantly compared with those values in fetuses without ductal constriction (186 +/- 48 vs. 150 +/- 30 mm2, 112 +/- 34 vs. 81 +/- 19 mm2 and 0.40 +/- 0.05 vs. 0.47 +/- 0.03, respectively, p < 0.01) without any significant changes in left ventricular area SF. Serial studies were available in eight ductal constriction fetuses before and during indomethacin administration, and after withdrawal of the drug for a mean of 24 h. Both systolic and diastolic ductal flow velocities in all fetuses returned to normal range after discontinuation of the drug. During ductal constriction during indomethacin therapy, right ventricular end-diastolic and end-systolic cavity areas were significantly larger and area SF was significantly less than those values before and after the therapy (179 +/- 38 vs. 157 +/- 30 and 154 +/- 27 mm2, 108 +/- 33 vs. 82 +/- 15 and 83 +/- 15 mm2 and 0.40 +/- 0.07 vs. 0.48 +/- 0.03 and 0.46 +/- 0.03, respectively, p < 0.01). This study suggests that ductal constriction influences right ventricular systolic performance.

Blood Flow Velocity↗

Ultrasound-mediated destruction of contrast agents. Effect of ultrasound intensity, exposure, and frequency.

RATIONALE AND OBJECTIVES: Although ultrasound contrast microbubbles theoretically could serve as tracers for the noninvasive quantification of blood flow, results have been inconsistent. Accurate quantification may be limited by ultrasound energy-mediated microbubble destruction. This study examined the effect of different ultrasound delivery parameters on microbubble destruction. METHODS: Experiments were performed in an in vitro hydraulic perfusion model consisting of a thin-walled rubber tube encased in agar. Ultrasonic parameters tested during different parts of the experiment were (1) intensity, (2) duration, and (3) frequency. Four ultrasound contrast agents: Aerosomes MRX115 (ImaRx Pharmaceuticals Corp., Tucson, AZ), Imagent AF0150 US (Alliance Pharmaceutical Corp., San Diego, CA), Levovist (Berlex Laboratories, Wayne, NJ), and Echogen (Sonus Pharmaceuticals, Bothel, WA) were imaged with three different ultrasound systems: ATL Ultramark AM-9 HDI, Vingmed 800 and Hewlett-Packard 2500. RESULTS: Microbubble destruction and reductions in reflectivity were noted in all agents tested. Although no significant reductions in counts or reflectivity occurred at 0.3 W/cm2 with any agent, exposure to 25 W/cm2 produced more than 80% reductions in both microbubble counts (P < 0.0001) and reflectivity (P < 0.0001). Declines in reflectivity were increased by longer exposure to ultrasound (P < 0.0001); slower flow through an ultrasound beam (P < 0.0001); continuous, rather than intermittent, imaging (P = 0.0002); use of a higher pulse repetition rate (P < 0.0001); and exposure to 2.5 MHz, rather than 7.5 MHz, ultrasound (P < 0.0001). CONCLUSIONS: Ultrasound energy-mediated destruction of contrast microbubbles is a function of many factors, including ultrasound intensity, duration, and frequency. Optimization of ultrasound delivery parameters may be used to maximize or minimize the destruction of ultrasound contrast agents.

Contrast Media↗

Preoperative gadolinium-enhanced magnetic resonance pulmonary venography in an adolescent with atrial septal defect.

The conventional preoperative evaluation of congenital heart disease in the adult using only echocardiography and cardiac catheterization is frequently limited. We report a case in which newer magnetic resonance imaging with gadolinium angiographic techniques proved helpful by conclusively documenting normal pulmonary venous return in a patient with secundum [corrected] atrial septal defect. This evaluation obviated the need for referral to a more specialized tertiary-care center for congenital heart disease and dramatized the value of an interdisciplinary approach to the adult patient with newly diagnosed congenital heart disease.

Adolescent↗

Left ventricular stroke work in mitral regurgitation: an animal experimental study.

BACKGROUND AND AIMS OF THE STUDY: Most studies on mitral regurgitation have focused on evaluating the regurgitant volume. The effects of mitral regurgitation and its associated cardiac workload on left ventricular function and mechanics may be equally important both in assessing the impact of regurgitation as well as in planning and evaluating therapy. The present study was undertaken to investigate the interrelationships of the regurgitant volume, hemodynamics and left ventricular work in an experimental animal model of chronic mitral regurgitation in which the regurgitant volume could be measured directly with electromagnetic flow probes. METHODS: A total of 21 hemodynamic states were studied in six sheep with surgically created mitral regurgitation. Regurgitant flow rates were obtained from electromagnetic flow meters. Left ventricular and atrial pressures were recorded using high-fidelity catheters. Regurgitant jet velocity was recorded by continuous wave Doppler. Left ventricular stroke work and energy losses due to the regurgitation were calculated. RESULTS: There was a close correlation between left ventricular stroke work and both jet energy and left atrial systolic pressure rise (r = 0.81, p = 0.0001 and r = 0.92, p = 0.0001, respectively). A moderate correlation to the regurgitant volume was found (r = 0.52, p = 0.01). CONCLUSIONS: The regurgitant volume itself is only one of the determinants of left ventricular stroke work in mitral regurgitation. Other factors such as left atrial mechanical properties and the regurgitant kinetic jet energy are at least as important for assessing cardiac work in patients with mitral regurgitation.

Animals↗

Intraoperative transesophageal echocardiography using high-resolution biplane 7.5 MHz probes with continuous-wave Doppler capability in infants and children with tetralogy of Fallot.

This study reports the role of biplane transesophageal echocardiography in monitoring surgical repairs of tetralogy of Fallot. In our patients, 3 repairs were revised based on transesophageal echocardiography and continuous-wave Doppler results, and intraoperative management was altered in 2 others.

Adolescent↗

Effective regurgitant orifice area by the color Doppler flow convergence method for evaluating the severity of chronic aortic regurgitation. An animal study.

BACKGROUND: The aim of the present study was to evaluate dynamic changes in aortic regurgitant (AR) orifice area with the use of calibrated electromagnetic (EM) flowmeters and to validate a color Doppler flow convergence (FC) method for evaluating effective AR orifice area and regurgitant volume. METHODS AND RESULTS: In 6 sheep, 8 to 20 weeks after surgically induced AR, 22 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary EM flowmeters balanced against each other. Instantaneous AR orifice areas were determined by dividing these actual AR flow rates by the corresponding continuous wave velocities (over 25 to 40 points during each diastole) matched for each steady state. Echo studies were performed to obtain maximal aliasing distances of the FC in a low range (0.20 to 0.32 m/s) and a high range (0.70 to 0.89 m/s) of aliasing velocities; the corresponding maximal AR flow rates were calculated using the hemispheric flow convergence assumption for the FC isovelocity surface. AR orifice areas were derived by dividing the maximal flow rates by the maximal continuous wave Doppler velocities. AR orifice sizes obtained with the use of EM flowmeters showed little change during diastole. Maximal and time-averaged AR orifice areas during diastole obtained by EM flowmeters ranged from 0.06 to 0.44 cm2 (mean, 0.24 +/- 0.11 cm2) and from 0.05 to 0.43 cm2 (mean, 0.21 +/- 0.06 cm2), respectively. Maximal AR orifice areas by FC using low aliasing velocities overestimated reference EM orifice areas; however, at high AV, FC predicted the reference areas more reliably (0.25 +/- 0.16 cm2, r = .82, difference = 0.04 +/- 0.07 cm2). The product of the maximal orifice area obtained by the FC method using high AV and the velocity time integral of the regurgitant orifice velocity showed good agreement with regurgitant volumes per beat (r = .81, difference = 0.9 +/- 7.9 mL/beat). CONCLUSIONS: This study, using strictly quantified AR volume, demonstrated little change in AR orifice size during diastole. When high aliasing velocities are chosen, the FC method can be useful for determining effective AR orifice size and regurgitant volume.

Animals↗

Evaluation of aortic regurgitation with digitally determined color Doppler-imaged flow convergence acceleration: a quantitative study in sheep.

OBJECTIVES: The aim of the present study was to validate a digital color Doppler-based centerline velocity/distance acceleration profile method for evaluating the severity of aortic regurgitation. BACKGROUND: Clinical and in vivo experimental applications of the flow convergence axial centerline velocity/distance profile method have recently been used to estimate regurgitant flow rates and regurgitant volumes in the presence of mitral regurgitation. METHODS: In six sheep, a total of 19 hemodynamic states were obtained pharmacologically 14 weeks after the original operation in which a portion of the aortic noncoronary (n = 3) or right coronary (n = 3) leaflet was excised to produce aortic regurgitation. Echocardiographic studies were performed to obtain complete proximal axial flow acceleration velocity/distance profiles during the time of peak regurgitant flow (usually early in diastole) for each hemodynamic state. For each steady state, the severity of aortic regurgitation was assessed by measurement of the magnitude of the regurgitant flow volume/beat, regurgitant fraction and instantaneous regurgitant flow rates determined by using both aortic and pulmonary artery electromagnetic flow probes. RESULTS: Grade I regurgitation (regurgitant volume/beat < 15 ml, six conditions), grade II regurgitation (regurgitant volume/beat between 16 ml and 30 ml, five conditions) and grade III-IV regurgitation (regurgitant volume/beat > 30 ml, eight conditions) were clearly separated by using the color Doppler centerline velocity/distance profile domain technique. Additionally, an equation for correlating "a" (the coefficient from the multiplicative curve fit for the velocity/distance relation) with the peak regurgitant flow rates (Q [liters/min]) was derived showing a high correlation between calculated peak flow rates by the color Doppler method and the actual peak flow rates (Q = 13a + 1.0, r = 0.95, p < 0.0001, SEE = 0.76 liters/min). CONCLUSIONS: This study, using quantified aortic regurgitation, demonstrates that the flow convergence axial centerline velocity/distance acceleration profile method can be used to evaluate the severity of aortic regurgitation.

Animals↗

Reversed shunting across the ductus arteriosus or atrial septum in utero heralds severe congenital heart disease.

OBJECTIVES: This study was performed to define the significance of Doppler color flow mapping in demonstrating reversal of the direction of the normal physiologic flow across the atrial septum and ductus arteriosus in the human fetus. BACKGROUND: Reversal of the physiologic shunting across the ductus arteriosus or atrial septum in utero (i.e., left to right) can be readily identified by Doppler color flow mapping, complemented by pulsed and continuous wave Doppler information. METHODS: We reviewed echocardiograms recorded at our three institutions from 1988 to 1993, which displayed reversal of flow by Doppler color flow in 53 fetuses of gestational age 18 weeks to term. The diagnoses were confirmed by postnatal echocardiography, operation or autopsy. Reversal of shunting was consistently associated with severe heart disease. RESULTS: Reversed atrial shunting was found with severe left heart obstructive lesions, including 19 with hypoplastic left heart syndrome, 3 with critical aortic stenosis, 2 with double-outlet right ventricle and 1 each with an interrupted aortic arch, atrioventricular septal defect and severe left ventricular dysfunction due to dilated cardiomyopathy. Reversed ductus arteriosus shunting was found with severe right heart obstructive lesions, including nine fetuses with pulmonary atresia, six with severe obstructive tricuspid valve abnormalities, five with severe tetralogy of Fallot, four with Ebstein's anomaly and two with single ventricle and pulmonary stenosis. Associated cardiac lesions were common in both groups. Only 3 of the 15 infants who were delivered alive from the reverse ductus arteriosus shunt group and 4 of 12 from the reverse atrial shunt group still survive. CONCLUSIONS: The finding of reversed flow by Doppler color flow mapping during fetal life provides a key to subsequent accurate diagnosis and denotes a spectrum of diseases with a very poor prognosis.

Ductus Arteriosus↗

Current status of flow convergence for clinical applications: is it a leaning tower of "PISA"?

Spatial appreciation of flow velocities using Doppler color flow mapping has led to quantitative evaluation of the zone of flow convergence proximal to a regurgitant orifice. Based on the theory of conservation of mass, geometric analysis, assuming a series of hemispheric shells of increasing velocity as flow converges on the orifice--the so-called proximal isovelocity surface area (PISA) effect--has yielded methods promising noninvasive measurement of regurgitant flow rate. When combined with conventional Doppler ultrasound to measure orifice velocity, regurgitant orifice area, the major predictor of regurgitation severity, can also be estimated. The high temporal resolution of color M-mode can be used to evaluate dynamic changes in orifice area, as seen in many pathologic conditions, which enhances our appreciation of the pathophysiology of regurgitation. The PISA methodology is potentially applicable to any restrictive orifice and has gained some credibility in the quantitative evaluation of other valve pathology, particularly mitral and tricuspid regurgitation, and in congenital heart disease. Although the current limitations of PISA estimates of regurgitation have tempered its introduction as a valuable clinical tool, considerable efforts in in vitro and clinical research have improved our understanding of the problems and limitations of the PISA methodology and provided a firm platform for continuing research into the accurate quantitative assessment of valve regurgitation and the expanding clinical role of quantitative Doppler color flow mapping.

Blood Flow Velocity↗

Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets: an in vitro quantitative study.

OBJECTIVES: This study sought to investigate the applicability of a current implementation of a three-dimensional echocardiographic reconstruction method for color Doppler flow convergence and regurgitant jet imaging. BACKGROUND: Evaluation of regurgitant flow events, such as flow convergences or regurgitant jets, using two-dimensional imaging ultrasound color flow Doppler systems may not be robust enough to characterize these spatially complex events. METHODS: We studied two in vitro models using steady flow to optimize results. In the first constant-flow model, two different orifices were each mounted to produce flow convergences and free jets--a circular orifice and a rectangular orifice with orifice area of 0.24 cm(2). In another flow model, steady flows through a circular orifice were directed toward a curved surrounding wall to produce wall adherent jets. Video composite data of color Doppler flow images from both free jet and wall jet models were reconstructed and analyzed after computer-controlled 180 degrees rotational acquisition using a TomTec computer. RESULTS: For the free jet model there was an excellent relation between actual flow rates and three-dimensional regurgitant jet volumes for both circular and rectangular orifices (r = 0.99 and r = 0.98, respectively). However, the rectangular orifice produced larger jet volumes than the circular orifice, even at the same flow rates (p < 0.0001). Calculated flow rates by the hemispheric model using one axial measurement of the flow convergence isovelocity surface from two-dimensional color flow images underestimated actual flow rate by 35% for the circular orifice and by 44% for the rectangular orifice, whereas a hemielliptic method implemented using three axial measurements of the flow convergence zone derived using three-dimensional reconstruction correlated well with and underestimated actual flow rate to a lesser degree (22% for the circular orifice, 32% for the rectangular orifice). In the wall jet model, the jets were flattened against and spread along the wall and had reduced regurgitant jet volumes compared with free jets (p < 0.01). CONCLUSIONS: Three-dimensional reconstruction of flow imaged by color Doppler may add quantitative spatial information to aid computation methods that have been used for evaluating valvular regurgitation, especially where they related to complex geometric flow events.

Echocardiography, Doppler, Color↗

Myocardial imaging with a new transpulmonary lipid-fluorocarbon echo contrast agent: experimental studies in pigs.

The development of echo contrast agents that can provide reliable opacification of the myocardium after intravenous injection is an important advancement for the clinical application of contrast echocardiography. In this study, the hemodynamic effects and echocardiographic characteristics of a new lipid-fluorocarbon echo contrast agent, Aerosomes MRX 115 (ImaRx Pharmaceutical Corp., Tucson, Ariz.) were studied in six anesthetized ventilated pigs. Intravenous injection of this new agent in doses ranging from 0.0005 to 0.01 ml/kg produced significant measurable and visible myocardial opacification without any effect on heart rate, systemic pressure, partial pressure of oxygen, or left ventricular systolic function. The two largest doses (0.005 and 0.01 ml/kg), however, resulted in mild reversible increases in mean pulmonary artery pressure of 12 and 16 mm Hg, respectively. In four animals, epicardial images were obtained before and during coronary artery occlusion. Intravenous contrast injection during coronary occlusion permitted delineation of the hypoperfused myocardial segment. This capability may further expand the utility of contrast echocardiography.

Animals↗

Evaluation of eccentric aortic regurgitation by color Doppler jet and color Doppler-imaged vena contracta measurements: an animal study of quantified aortic regurgitation.

To evaluate the utility of measurements of the color Doppler jet area, jet length, and width of the color Doppler-imaged vena contracta (the smallest flow diameter in any part of the flow acceleration field) as methods for quantifying aortic regurgitation (AR), eight sheep with surgically induced AR were studied. AR was quantified as peak and mean regurgitant flow rates, regurgitant stroke volumes, and regurgitant fractions as determined with pulmonary and aortic electromagnetic flow probes and flowmeters balanced against each other. Simple linear regression analysis between the maximal color jet areas, jet length, and flowmeter data showed only moderately good correlation (jet area: 0.42 < or = r < or = 0.57, SEE = 2.85 cm2; jet length: 0.42 < or = r < or = 0.59, SEE = 1.23 cm). In contrast, the width of color Doppler-imaged vena contracta was a better indicator of the severity of AR on the basis of the electromagnetic flowmeter methods (0.73 < or = r < or = 0.90, SEE = 0.15 cm). Therefore the color Doppler jet length and jet area methods have limited use for determining AR, whereas the width of the color Doppler-imaged vena contracta can be used for quantifying the severity of AR.

Animals↗

Pediatric echocardiography: current role and a review of technical advances.

Advances in echocardiography have enhanced our diagnostic imaging capabilities for congenital heart defects. In addition to improved resolution of two-dimensional images, cardiac hemodynamic assessment is possible with the use of Doppler, color Doppler, and stress echocardiography. Transesophageal echocardiography has allowed intraoperative assessment of cardiac repairs, and fetal echocardiography has allowed development of the field of fetal cardiology. The developing areas of intravascular ultrasonography and three-dimensional echocardiography show promise for the future. Echocardiography continues to revolutionize our ability to diagnose congenital heart defects accurately.

Echocardiography↗