Search PubMed⌕ Search

Biomedical subjects

D J Parker

Publications and source records attributed to D J Parker.

At least 19 recordsLinked to original sources

Convection in vibrated annular granular beds.

The response to vibration of a granular bed, consisting of a standard cylindrical geometry but with the addition of a dissipative cylindrical inner wall, has been investigated both experimentally (using positron emission particle tracking) and numerically (using hard sphere molecular dynamics simulation). The packing fraction profiles and granular temperature distributions (in both vertical and horizontal directions) were determined as a function of height and distance from the axis. The two sets of results were in reasonable agreement. The molecular dynamics simulations were used to explore the behavior of the granular bed in the inner wall-outer wall coefficient of restitution phase space. It was observed that one could control the direction of the toroidal convection rolls by manipulating the relative dissipation at the inner and outer walls via the coefficients of restitution, and with several layers of grains it was seen that double convection rolls could also be formed, a result that was subsequently confirmed experimentally.

Journal Article↗

Adsorption kinetics of fluoride on low cost materials.

Adsorption is one important technique in fluoride removal from aqueous solutions. The viability of adsorption techniques is greatly dependent on the development of adsorptive materials. A large number of materials have been tested at a fluoride concentration greater than 2 mg/l, and the lowest limit for fluoride reduction by them is about 2 mg/l. Decreasing the fluoride concentration to less than 2 mg/l, most of the tested materials displayed a very low capacity of fluoride removal. This paper has concentrated on investigating the adsorption kinetics and adsorption capacity of low cost materials at a low initial fluoride concentration. The experiments were carried out at a natural pH, and radioisotope 18F rather than 19F was used since 18F can be rapidly measured by measuring the radioactivity with a resolution of 1 x 10(-13)mg or 0.01 microCi. The tested materials are hydroxyapatite, fluorspar, calcite, quartz and quartz activated by ferric ions. Their adsorption capacities follow the order: Hydroxyapatite>Fluorspar>Quartz activated using ferric ions>Calcite>Quartz. The uptake of fluoride on hydroxyapatite is an ion-exchange procedure and follows the pseudo-first- and second-order equations, while the uptake of fluoride on the others is a surface adsorption and follows the pseudo-second-order equation. Calcite has been seen as a good adsorbent in fluoride removal and has been patented. However, our data suggested that its adsorption capacity is only better than quartz. The external mass transfer is a very slow and rate-determining step during fluoride removal from the aqueous solution. Under static conditions, there was no relative movement between adsorbents and solutions, the fluoride uptake was at a very slow rate and the adsorbent properties did not significantly affect the fluoride uptake. Under shaken conditions, the adsorption of fluoride was controlled by the adsorbent structure and chemical properties.

Adsorption↗

Coexistence of two granular temperatures in binary vibrofluidized beds.

An investigation into the granular temperature distributions of a binary vibrofluidized granular bed has been conducted using positron emission particle tracking. By repeating each experiment with the tracer selected in turn from the two size components, the granular temperature and packing fraction distributions for each phase were determined. It was found that, for a range of size fractions, the granular temperature of the larger particles was higher than that of the smaller diameter grains, a result which was supported by a simple theoretical analysis based on the steady state energy equation.

Journal Article↗

Numerical solution of the Smoluchowski equation for a vibrofluidized granular bed.

A stochastic approach, similar to that used to describe Brownian motion, was used to model the displacement probability of grains in a three-dimensional vibrofluidized granular bed. As neither an analytical description nor measurements of the diffusion coefficients were available, the governing partial differential equation, namely, the Smoluchowski equation, was solved numerically using an iterative procedure, modifying the granular temperature profile at each step. The results of this stochastic model were compared to experimental measurements of the displacement probability density made using positron emission particle tracking. The results indicate that methods based on hard elastic systems such as the Smoluchowski equation are appropriate to granular systems, particularly over timescales greater than the mean collision time.

Journal Article↗

Granular temperature profiles in three-dimensional vibrofluidized granular beds.

The motion of grains in a three-dimensional vibrofluidized granular bed has been measured using the technique of positron emission particle tracking, to provide three-dimensional packing fraction and granular temperature distributions. The mean square fluctuation velocity about the mean was calculated through analysis of the short time mean squared displacement behavior, allowing measurement of the granular temperature at packing fractions of up to eta approximately 0.15. The scaling relationship between the granular temperature, the number of layers of grains, and the base velocity was determined. Deviations between the observed scaling exponents and those predicted by recent theories are attributed to the influence of dissipative grain-sidewall collisions.

Journal Article↗

Convection in highly fluidized three-dimensional granular beds.

Free, buoyancy-driven convection has been observed experimentally in three-dimensional highly fluidized granular flows for the first time. Positron emission particle tracking was used to determine the position of a tracer grain in a vibrofluidized bed, from which packing fraction distributions as well as the velocity fields could be determined. The convection rolls, although small compared to the magnitude of velocity fluctuations (<5%), were consistently observed for a range of grain numbers and shaker amplitudes. Density variations are a signature of free convection and, with negative temperature gradients also present, were interpreted as the mechanism by which the convection rolls were initiated.

Journal Article↗

Use of the 400 Hz period evoked potential in the prediction of loudness discomfort levels in normal hearing adults.

This study investigated normally-hearing adult subjects to establish whether the 400 Hz Period Evoked Potential (PEP) can be used to predict Loudness Discomfort Level (LDL). Parameter-intensity functions were obtained using the response measures (400 Hz components) of amplitude, phase, magnitude squared coherence (MSC) and phase coherence (PC). The best predictor of the subjective LDL was found to be the gradient of the individual's amplitude-intensity function for significant (MSC > 0.264 and/or PC > 0.525) responses only. In this case 82% are predicted within 10 dB and there is a maximum error of 15 dB.

Adult↗

Measures of cochlear travelling wave delay in humans: I. Comparison of three techniques in subjects with normal hearing.

This study was designed to estimate and compare measures of cochlear travelling wave delay and travelling wave velocity in normally-hearing adults. Travelling wave delay and velocity measures were estimated in 23 normally-hearing adults using three different test techniques: i) derived auditory brainstem responses (ABR); ii) derived frequency-following responses (FFR); and iii) tone-burst-evoked otoacoustic emissions (TBEOAE). Estimates from ABR and TBEOAE were comparable to each other in terms of both averaged group values and associated standard deviations. Furthermore, mean cochlear travelling wave velocity estimated from ABR and TBEOAE were comparable to published estimates. Average cochlear delays obtained using the derived FFR were significantly shorter than those obtained from the other two techniques, possibly due to the effect of cochlear microphonic contamination. Among the dependent variables investigated, measures of delay are to be preferred over velocity since the latter are based on uncertain values of cochlear distance.

Acoustic Stimulation↗

A comparison of the accuracy and reproducibility of digital three-dimensional coronary artery reconstructions using edge detection or videodensitometry.

Global quantitative three-dimensional measurements of coronary arteries may be helpful in determining the functional significance of various forms of coronary pathology. A computerized system has been developed that is capable of performing 3-D reconstruction of digitized images obtained from multiple coronary angiographic views using either automated edge detection (AED) or videodensitometric (VD) techniques. To compare the accuracy and reproducibility of measurements obtained from this system using either technique, stationary and moving coronary aluminum 3-D phantoms, each with 13 branches (diameter 0.58-6.35 mm, length 21.5-64.5 mm), were imaged and reconstructed 10 separate times each. Individual branch lengths and diameters were calculated and compared to each other and to known values. Diameter measurements were compared using either AED or VD. Intraclass correlation coefficients between observed values (ICC) for vessel length were r = 0.89 for the stationary and r = 0.97 for the moving phantom. ICCs for vessel diameter were r = 0.93 (AED) and r = 0.95 (VD) for the stationary and r = 0.98 (AED) and r = 0.97 (VD) for the moving phantom. Mean differences (+/-SD) between true and observed values [MDTO(+/-SD)] for vessel length were -1.0 +/- 3.9 mm for the stationary and -3.5 +/- 3.2 mm for the moving phantom. MDTO(+/-SD) for vessel diameter were -0.10 +/- 0.52 mm (AED) and +0.03 +/- 0.30 mm (VD) for the stationary and -0.21 +/- 0. 44 mm (AED) and -0.12 +/- 0.33 (VD) for the moving phantom. We conclude that the quantitative accuracy and reproducibility of measurements obtained by computerized 3-D reconstruction of coronary model phantoms is of high enough quality to warrant further clinical evaluation. VD appears to be more accurate than AED for measuring vessel diameter.

Aluminum↗

An attenuation measurement technique for rotating planar detector positron tomographs.

This paper presents a new attenuation measurement technique suitable for rotating planar detector positron tomographs. Transmission measurements are made using two unshielded positron-emitting line sources, one attached to the front face of each detector. Many of the scattered and accidental coincidences are rejected by including only those coincidences that form a vector passing within a predetermined distance of either line source. Some scattered and accidental coincidences are still included, which reduces the measured linear attenuation: in principle their contribution can be accurately estimated and subtracted, but in practice, when limited statistics are available (as is the case with the multi-wire Birmingham positron camera), this background subtraction unacceptably increases the noise. Instead an attenuation image having the correct features can be reconstructed from the measured projections. For objects containing only a few discrete linear attenuation coefficients, segmentation of this attenuation image reduces noise and allows the correct linear attenuation coefficients to be restored by renormalization. Reprojection through the segmented image may then provide quantitatively correct attenuation correction factors of sufficient statistical quality to correct for attenuation in PET emission images.

Electrons↗

Velocity measurement based on bolus tracking with the aid of three-dimensional reconstruction from digital subtraction angiography.

The problem of blood flow measurement in x-ray angiography using measurements of the leading edge of the contrast bolus as it traverses the vascular bed is considered. A new technique for velocity measurement is presented based upon the ratio of the temporal derivative to the spatial derivative of the contrast bolus in the direction of flow. With the addition of a small correction factor, the value obtained is shown to reflect the transport velocity, or the velocity at which the contrast is transported down the vessel of interest. Most blood flow measurements based on bolus tracking techniques are actually using the contrast transport velocity to represent the blood flow velocity. Because of the streaming that occurs due to laminary flow conditions, the measured transport velocity is found to be somewhere between the average and the peak (central) fluid velocities for measurements taken during the traversal of the bolus leading edge. The spatial and temporal variation of the transport velocity are found to be consistent with the bolus motion expected in the presence of laminar flow. From x-ray images of contrast passage through simple tubes, we find that the derivative method measures the transport velocity during passage of the bolus leading edge. In most cases of laminar blood flow, the leading edge transport velocity can be 20%-40% higher than the average blood velocity.

Angiography, Digital Subtraction↗

Long-term results of coronary artery bypass grafting.

The treatment of ischemic heart disease by coronary artery bypass grafting remains under intense scrutiny. A better understanding of the long-term outcome for particular patient subgroups will allow a more appropriate choice to be made among the options of coronary artery bypass grafting, angioplasty, or continued medical management. Such information would also permit patients to make informed choices when their preferences influence the decision. A clearer understanding of the importance of risk-factor management (in particular lipid reduction by drug treatment) will improve the long-term results for patients undergoing surgical treatment (probably in both late mortality and late clinical events). Such an understanding can also clarify the need for further intervention.

Age Factors↗

Demographic characteristics of patients undergoing aortic valve replacement for stenosis: relation to valve morphology.

OBJECTIVE: To determine the relative importance of the different causes of isolated aortic valve stenosis in a surgical series, and to relate these to patient characteristics including the rate of insertion of bypass grafts for coronary artery disease. DESIGN: Survey of the clinical and pathological data on patients undergoing aortic valve replacement for isolated stenosis. SETTING: Tertiary care cardiothoracic surgical unit. PATIENTS AND METHODS: 465 adult patients undergoing aortic valve replacement representing a consecutive series in one surgical unit. Retrospective review of patients records and classification of cause of aortic stenosis based on pathological examination of excised valve cusps. RESULTS: 63.7% patients had calcific bicuspid valves, 26.9% tricuspid calcific valves, and 5.4% rheumatic, 2.6% mixed pathology and 1.5% unicommissural valves. The ratio of males to females for bicuspid valves was 1.85:1 and for tricuspid calcific valves 0.76:1. The mean age of patients with bicuspid valves was 64.9 years compared with 73.4 years for those with tricuspid valves. Some 22.3% of patients with bicuspid valves and 44.8% of those with tricuspid valves had sufficient coronary artery disease to necessitate insertion of coronary bypass grafts. The differential rate of insertion of coronary bypass grafts was independent of age. CONCLUSIONS: Bicuspid calcified aortic valves are the predominant cause of isolated aortic valve stenosis followed by tricuspid calcified aortic valves. The sex and age distribution of bicuspid and tricuspid calcific aortic valve stenosis is different. The higher rate of insertion of vascular grafts in tricuspid calcific aortic valves may indicate that risk factors for atherosclerosis enhance cusp calcification in these patients.

Adult↗

Planning for coronary angioplasty: guidelines for training and continuing competence. British Cardiac Society (BCS) and British Cardiovascular Intervention Society (BCIS) working group on interventional cardiology.

The following recommendations are made: 1 Existing centres undertaking angioplasty should increase their activity, and the target figure of 400 PTCA procedures per million of the United Kingdom population should be achieved by the end of 1996-97, or immediately thereafter. 2 Angioplasty centres should be appropriately equipped to undertake PTCA safely and effectively and provide a reliable emergency service. They should have a minimum of two trained PTCA operators jointly undertaking a minimum of 200 procedures per year at that centre, and have regular meetings to share experience. 3 Angioplasty operators should ensure that where the need arises patients undergoing PTCA can receive immediate attention from a trained operator at any time until discharge from hospital. 4 Trained operators should undertake at least 1-2 PTCA procedures per week (> 60 procedures per year) to maintain competence, and those undertaking so few procedures should increase their activity over the next three years to more than 100 a year. 5 Trainers should have performed at least 500 procedures before formally training others and should undertake a minimum of 125 procedures a year to maintain accreditation as a trainer. 6 Surgical cover for PTCA procedures should be mandatory and on site cover remains the strongly preferred option. Where surgical cover is provided off site, this should be at a centre less than 30 minutes away by road. Whether provided on or off-site it should be possible to establish cardiopulmonary bypass within 90 minutes of the decision being made to refer the patient for surgery. 7 All operators and interventional centres should audit their activity and results, review these data locally with colleagues, and provide regular audit returns to the national database run by BCIS. This will allow future recommendations concerning standards to take more account of risk stratification and actual outcomes, and not place such emphasis merely on volumes of activity. 8 These recommendations should be reviewed in three years.

Angioplasty, Balloon, Coronary↗

Otoacoustic emission versus ABR screening: the effect of external and middle ear abnormalities in a group of SCBU neonates.

Twenty neonates in a special care baby unit (SCBU) were tested using automated procedures for obtaining auditory brainstem responses (ABR) and transient evoked otoacoustic emissions (TEOAE). All 40 ears passed the initial ABR screen, while the pass rate for the TEOAE screen was only 52.5%. Ears with no external or middle ear abnormalities (group A) had a significantly higher TEOAE pass rate (94.7%) than those with at least one abnormality (group B) as detected by otoscopic examination and tympanometry (14.3%). Other variables, such as age at test, gestational age at birth and birth weight, did not differ significantly between groups A and B. We conclude that external/middle ear abnormalities in this group of neonates had no effect on the ABR screening results, but had a significant effect on the TEOAE screening results.

Acoustic Impedance Tests↗

Training surgeons and safeguarding patients.

Surgical trainees need exposure to a wide variety of operations and a chance to operate under supervision. At the same time there is the over-riding responsibility to do the best for our patients. Cardiac surgery is dominated by coronary bypass surgery and the tendency has been to delegate easy coronary cases to trainees and to neglect their experience in other areas. This paper is an audit of trainee exposure and supervision in a training centre. During a 20-month period, 35.2 per cent of cases were delegated; 20.6 per cent to the senior registrar and 14.6 per cent to the registrars. Senior registrars were assisted by the consultant in 19.1 per cent of their cases and registrars were assisted by more senior colleagues in 28.5 per cent of theirs. Most cases delegated to trainees were of low perioperative risk and operations were performed with commensurate low morbidity and mortality. The delegation of valve surgery was disproportionately low in comparison to overall case mix. On the basis of this study, the delegation of cases is being reviewed in the knowledge that with appropriate selection, trainees can gain valuable operative experience without compromising patient-safety.

Aged↗

Resternotomy for bleeding after cardiac operation: a marker for increased morbidity and mortality.

Over a 2-year period from January 1, 1992, to December 31, 1993, of 2,221 patients undergoing cardiac operations in our unit, 85 (3.8%) were reopened for the control of bleeding (9 patients more than once). The incidence of resternotomy in coronary cases was 2.3%, but resternotomy was more than three times as likely in valve cases (odds ratio, 3.4; 95% confidence interval, 2.1 to 5.4). Previous cardiac operation was more common among resternotomy patients than among the remainder (18% versus 9%, respectively; p = 0.018). An identifiable source of bleeding was found in 57 of the 85 patients (67%), but a concurrent coagulopathy was common (45 patients). Resternotomy patients, as a group, had higher preoperative risk scores (Parsonnet) than did the other patients (p < 0.0001), stayed longer in the intensive care unit (p < 0.0001), and had greater requirements for intraaortic balloon counterpulsation (14% versus 3%) and hemofiltration (9% versus 3%) (p < 0.0001 and p < 0.01, respectively). Nineteen resternotomy patients (22%) died in the hospital, a proportion significantly greater than the risk assigned to this group of patients preoperatively (12.8%) (p = 0.008). In contrast, the observed mortality for the other 2,136 patients (5.5%) was significantly less (8.3%) (p < 0.00006). Multiple forward stepwise logistic-regression analysis confirmed resternotomy for excessive bleeding after cardiac operation to be a significant independent predictor of a prolonged stay in the intensive care unit (p < 0.0001), the need for intraaortic balloon counterpulsation (p < 0.0001), and death (p < 0.0001).

Aged↗

Short-term effects of intra-aortic balloon pumping on renal blood flow and renal oxygen consumption in cardiogenic shock.

Intra-aortic balloon pumping is frequently used in patients with cardiogenic shock when oliguria persists despite maximal pharmacologic support. The objective of this study was to measure the effect of intra-aortic balloon pumping on renal blood flow, renal oxygen delivery, and renal oxygen consumption in such patients. Central hemodynamics, renal blood flow, and oxygen transport were measured in 10 patients in low cardiac output states. Measurements were made with and without intra-aortic balloon counterpulsation. Renal blood flow was measured by continuous renal vein thermodilution. Small improvements were observed in cardiac output (3.1 +/- 0.8 vs 3.5 +/- 0.8 L/min, P < .01) and pulmonary capillary wedge pressure (22 +/- 5.6 vs 19 +/- 5.3 mmHg, P < .05), but mean arterial blood pressure was unchanged (69 +/- 11 vs 69 +/- 5 mmHg, not significant). Baseline renal blood flow was reduced to approximately 37%, renal oxygen delivery to 31%, and renal oxygen consumption to 60% of normal values. No significant improvement was seen in single-kidney renal blood flow (184 +/- 108 vs 193 +/- 107 mL/min), renal oxygen delivery (28 +/- 16 vs 30 +/- 16 mL/min), or renal oxygen consumption (4.9 +/- 2.0 vs 4.7 +/- 2.5 mL/min) in response to 1:1 counterpulsation. In comparison with measurements made during short-term suspension of counterpulsation, 1:1 aortic balloon pumping failed to result in an increase in renal blood flow, oxygen delivery, or oxygen consumption from the low levels observed in these patients.

Adult↗