Search PubMed⌕ Search

Biomedical subjects

D J Newman

Publications and source records attributed to D J Newman.

At least 73 records · Page 4Linked to original sources

Coral reefs, forests, and thermal vents: the worldwide exploration of nature for novel antitumor agents.

Nature has been a source of medicinal treatments for thousands of years, and plant-based systems continue to play an essential role in the primary health care of 80% of the world's population. Nature has provided many of the effective anticancer agents in current use, such as the microbially derived drugs, dactinomycin, bleomycin, and doxorubicin, and the plant-derived drugs vinblastine, irinotecan, topotecan, etoposide, and paclitaxel. The search for novel antitumor agents from natural sources continues with botanists, marine biologists, and microbiologists teaming up with chemists, pharmacologists, toxicologists, and clinicians in the investigation of coral reefs, rainforests, and deep subsurface thermal vents for novel bioactive compounds. The wealth of anticancer drugs of natural origin and critical aspects of the ongoing discovery and development process are discussed.

Animals↗

Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephelometer systems (BNA, BN II).

Serum cystatin C has been suggested as a new marker of glomerular filtration rate (GFR). We describe a fully automated and rapid particle-enhanced nephelometric immunoassay (PENIA) for measuring serum cystatin C on the Behring nephelometer systems (BNA, BN II). Each sample is analyzed in 6 min with as many as 75 samples per batch. The assay covers the range 0.23-7.25 mg/L, up to seven times the upper limit of normal. The intra- and interassay imprecision are < 3.3% and < 4.5%, respectively. There is absolute linearity across the assay range (r2 = 0.997), with analytical recovery by cystatin C addition between 95% and 109% (mean 102%). Hemoglobin (< or = 8.0 g/L), bilirubin (< or = 488 microL), triglycerides (< or = 23 mmol/L), rheumatoid factor (< or = 2000 kIU/L), and myeloma paraprotein (< or = 41 g/L) do not interfere with the assay. This assay agreed well with an in-house particle-enhanced turbidimetric immunoassay (PETIA) (mean difference = 1.73 +/- 2.10) and a commercial PETIA (mean difference = 1.13 +/- 0.86). This is a new assay by which cystatin C may be effectively used as a marker of GFR estimation.

Animals↗

Kinetics and proposed mechanism of the reaction of an immunoinhibition, particle-enhanced immunoassay.

We report kinetic studies on the reaction of a latex agglutination immunoassay used to quantify phenytoin in serum. In this assay, polystyrene particles with a covalently attached analog of phenytoin react with an antiphenytoin monoclonal antibody to form light-scattering aggregates, with the rate of this reaction being decreased by addition of phenytoin from sample. In the absence of free (sample) phenytoin, this reaction did not exhibit a maximum rate of agglutination in the presence of excess antibody, i.e., an equivalence point. Furthermore, agglutination was inhibitable by free phenytoin even when the latter was added after agglutination of particles with antibody had begun. Most significantly, the immunoagglutination proceeded in an identical fashion with monovalent F(ab) fragment. These data are consistent with low-affinity immunospecific particle-antibody complexation, which then induces colloidal aggregation, without requiring immunospecific bridging by antibody molecules. The described mechanism is not generalizable to all latex agglutination immunoassays, although disturbance of colloidal stability may be a component in most assays.

Antibodies, Monoclonal↗

The use of the Micral-Test strip to identify the presence of microalbuminuria in people with insulin dependent diabetes mellitus (IDDM) participating in the EUCLID study.

In IDDM, microalbuminuria (urinary albumin excretion rate (AER) of 20-200 micrograms/min) is a predictor of persistent proteinuria and diabetic nephropathy. Early intervention may prevent or reduce the rate of progression of renal complications. The Micral-Test strip can be used to establish a semi-quantitative estimate of AER. We assessed the field performance of the Micral-Test strip in detecting microalbuminuria in the EUCLID study, an European wide, 18 centre study of 530 IDDM participants, aged 20 to 59 years. People with macroalbuminuria were excluded. On entry, all participants had albumin concentrations from two overnight urine collections measured by a central laboratory, and the corresponding Micral-Test performed on the two collections locally. a cut off of > or = mg/l albumin from the first Micral-Test, to detect a centrally measured albumin concentration > or = 20 mg/l, yielded 29 (5.8%) false negative results and 58 (11.6%) false positive results (sensitivity 70%, specificity 87%). The mean AER, from two collections, was compared with the corresponding 'pooled' Micral-Test results (mean of the two readings). Receiver Operating Characteristic (ROC) curves were used to assess if there was a suitable 'pooled' Micral-Test result for screening microalbuminuria. A 'pooled' Micral-Test result (> or = 15 mg/l) was used to detect mean AER > or = 20 micrograms/min (sensitivity 78%, specificity 77%). This 'pooled cut-off' had already been used for screening on to the study and led to an over-estimate (154 vs. 77) of the true number of microalbuminuric participants on the study. In conclusion, our findings suggest that the Micral-Test strip is not an effective screening tool for microalbuminuria, using the 'pooled' result from two measurements did not improve the sensitivity of the test.

Adult↗

Molecular aspects of design of immunoassays for drugs.

An understanding of the molecular structure of the antibody binding site, the epitope complementary to the antibody, and the intermolecular forces that determine the affinity and specificity of the interaction of antibody and epitope is fundamental to the design of immunoassays. This is particularly important for haptens because their small size results in small changes in substituent functional groups, e.g., optical rotation and carboxyl substitution for amide resulting in large changes in binding affinity. It should be possible to predict the effect of haptenic structure on binding affinity by considering the resulting changes in balance between the different intermolecular forces. This information can be used in designing immunogens and modifying the reaction conditions used during assay optimization, such as pH or ionic strength, that enhance the predominant intermolecular forces to increase the binding affinity but leave minimal matrix effects. Improved understanding of the molecular aspects of the immunological interaction can facilitate more rapid and economic immunoassay development.

Drug Design↗

Immunosensors: technology and opportunities in laboratory medicine.

An immunosensor is a device comprising an antigen or antibody species coupled to a signal transducer, which detects the binding of the complementary species. An indirect immunosensor uses a separate labeled species that is detected after binding by, e.g., fluorescence or luminescence (i.e., a heterogeneous immunoassay). A direct device detects the binding by a change in potential difference, current, resistance, mass, heat, or optical properties (i.e., a homogeneous immunoassay). Although indirect sensors may encounter fewer problems due to nonspecific binding effects, the direct sensors are capable of real-time monitoring of the antigen-antibody reaction. A wide range of molecules can be detected with detection limits ranging between 10(-9) and 10(-13) mol/L. However, there are only a few successful commercial applications of direct immunosensors, these being of the optical type. This review describes the principles underlying the technologies, their merits, limitations, and applications.

Biosensing Techniques↗

Validation of a particle enhanced immunoturbidimetric assay for serum beta 2-microglobulin on the Dade aca.

We describe the development and validation of a fully automated homogeneous immunoassay for serum beta 2-microglobulin on the Dade aca clinical analyzer. The assay employs latex enhanced immunoturbidimetry, with an affinity purified polyclonal antibody covalently coupled to a 40 nm latex particle. The assay working range is < 0.5 to 20 mg/l with no evidence of loss of signal due to antigen excess at concentrations up to 120 mg/l. The assay sensitivity is 0.2 mg/l; within run and between run imprecision showed coefficients of variations of < 7%, across the assay range 1-20 mg/l. A method comparison with an established RIA procedure gave a regression equation of (aca) = 1.14 (RIA)-0.26, r = 0.996, n = 109. Good analytical recovery (98-101%), no evidence of a lack of parallelism and no interference from rheumatoid factor (tested up to 1.2 x 10(6) U/l) were observed. The low method to be considered as an effective means of monitoring seroconversion in HIV infected subjects and treatment of patients with myelomatosis.

Arthritis, Rheumatoid↗

A novel phorbol ester from Excoecaria agallocha.

The novel phorbol ester 12-deoxyphorbol 13-(3E,5E-decadienoate) [1] was isolated as the anti-HIV principle of Excoecaria agallocha leaves and stems collected in northwest Australia. The structure was determined by spectral means. Compound 1 was also a potent displacer of [3H]-phorbol dibutyrate from rat brain membranes.

Animals↗

Serum cystatin C measured by automated immunoassay: a more sensitive marker of changes in GFR than serum creatinine.

Serum cystatin C has been suggested as a new marker of GFR. For the introduction of this marker into clinical use a rapid and automated method is required. We have developed and validated an assay for serum cystatin C using latex particle-enhanced immunoturbidimetry. Intra- and inter-assay precision were < 3% and < 5% across the assay range. Analytical recovery was 93 +/- 3.8% and no lack of parallelism was demonstrated. Regression analysis of a method comparison with an enzyme-enhanced radial-immunodiffusion method, gave PETIA = 0.074 + 0.93 x SRID, r = 0.98, N = 100. Inter-assay precision profiles showed cystatin C was measured with two-fold better precision than creatinine on the same analyzer. Cystatin C measurement was neither interfered with by icterus nor by hemolysis. 1/cystatin C versus 1/creatinine concentrations gave r = 0.67, N = 469. Comparison of Cr EDTA GFR with 1/cystatin C and 1/creatinine gave r = 0.81 and 0.50, respectively, N = 206. Calculating diagnostic sensitivity for abnormal GFR showed cystatin C to be significantly (P < 0.05) more sensitive than creatinine (71.4 vs. 52.4%). Cystatin C measurement using PETIA technology can be automated on the same instruments used routinely for the measurement of creatinine and offers better analytical performance and probably improved clinical sensitivity as a screening test for early renal damage.

Biomarkers↗

Automated dibucaine number measurement with DuPont Dimension ES and AR analyzers.

We report a fully automated method for determining dibucaine number (DN) in a single-run procedure involving Dimension cholinesterase (CHE) Flex pseudo-(P)CHE reagents. The method was developed and optimized with the "open channels" and "kinetic" software facilities of the Dimension-ES instrument, where the DN is calculated automatically by an algorithm from the ratio of the uninhibited and inhibited rates, measured bichromatically, from a single analysis. The protocol was satisfactorily assessed for substrate depletion, linearity, reagent stability. and the effects of different dibucaine concentrations. Validation was performed across a range of CHE activities (1.5-22 kU/L) representing the three main genotypes, UU, UA, and AA. The respective DNs (mean +/- SD), determined on the Dimension-ES, were 82.0 +/- 1.6 (n = 32), 71.0 +/- 3.1 (n = 10), and 23.0 +/- 2.7 (n = 14), with corresponding imprecisions (CV) of 0.3%, 0.6%, and 5.2% (intraassay) and 0.7%, 0.7%, and 8.6% (interassay). Comparisons with reference (x) laboratory values and the DuPont aca (x') procedure (n = 53) gave regression equations of: y = 0.88x + 11.2, r = 0.99, and y = 0.85x' + 11.9, r = 0.99. A separate trial conducted with a Dimension-AR instrument gave similar performances. We conclude that the new DN method is fast, efficient, and appropriate for clinical use.

Autoanalysis↗

Use of urine albumin measurement as a replacement for total protein.

We have investigated the replacement of urine total protein estimations for the assessment of glomerular permeability, by the measurement of urine albumin excretion using a latex particle enhanced immunoturbidimetric assay. An initial screen was performed using Albustix to assess the sample pre-dilution necessary for immunoanalysis. A total of 167 24-hour urine samples were analysed and urine albumin concentration correlated well with that of urine total protein (r = 0.93) over the range 0-16,800 mg/l. This protocol provides a more cost effective and analytically valid assessment of glomerular permeability.

Albuminuria↗

Ethnobotany and drug discovery: the experience of the US National Cancer Institute.

Between 1960 and 1981 the National Cancer Institute (NCI) screened 114,000 extracts of 35,000 plants, mainly collected in temperate regions. Of the three clinically active anticancer drugs so far discovered in that programme, none was isolated from a plant collected on an ethnobotanical basis, though various Taxus species, which are the source of taxol, are reported to have been used medicinally. Since 1986, the NCI has focused its collections in tropical and subtropical regions worldwide; collections cover a broad taxonomic range, though priority is given to medicinal plants when relevant information is available. As of August 1993, 21,881 extracts derived from over 10,500 samples had been tested in a screen for activity against the human immunodeficiency virus (HIV); 2320 of these extracts were of medicinal plant origin. Approximately 18% of both the total number of extracts and the medicinal plant-derived extracts showed significant anti-HIV activity; in each instance about 90% of the active extracts were aqueous. The activity of the aqueous extracts has been attributed mainly to the presence of polysaccharides or tannins. Four plant-derived compounds are in preclinical development at the NCI; only one of the four sources plants, obtained from a noncontract source, was collected on an ethnobotanical basis. At this stage the results indicate that the current NCI collection policy offers the best chances for the discovery and development of agents for the treatment of AIDS (acquired immune deficiency syndrome) and cancer.

Drug Screening Assays, Antitumor↗

The influence of glycation on the peroxidase activity of haemoglobin.

The peroxidase activity of haemoglobin A was characterized for non-glycated and glycated haemoglobin (HbA1) within the pH range 4.5 to 6.0, by measuring the rate of oxidation of 5-aminosalicylic acid following the degradation of H2O2. Glycation was found to significantly lower the pH activity of haemoglobin peroxidase throughout the pH range. However, in the presence of 100 mmol/l sorbitol the pH activity profile of glycated haemoglobin was significantly elevated whilst that of non-glycated haemoglobin remained unchanged.

Aminosalicylic Acids↗

Energetics and mechanics for partial gravity locomotion.

The role of gravitational acceleration on human locomotion is not clearly understood. It is hypothesized that the mechanics and energetics of locomotion depend upon the prevailing gravity level. A unique human-rated underwater treadmill and an adjustable ballasting harness were used to stimulate partial gravity environments. This study has two research aspects, biomechanics and energetics. Vertical forces which are exerted by subjects on the treadmill-mounted, split-plate force platform show that peak vertical force and stride frequency significantly decrease (p < 0.05) as the gravity level is reduced, while ground contact time is independent of gravity level. A loping gait is employed over a wide range of speeds (approximately 1.5 m/s to approximately 2.3 m/s) suggesting a change in the mechanics for lunar (1/6 G) and Martian (3/8 G) locomotion. As theory predicts, locomotion energy requirements for partial gravity levels are significantly less than at 1 G (p < 0.05).

Adult↗

Human locomotion and workload for simulated lunar and Martian environments.

Human locomotion in simulated lunar and Martian environments is investigated. A unique human-rated underwater treadmill and an adjustable ballasting harness simulate partial gravity in order to better understand how gravity determines the biomechanics and energetics of human locomotion. This study has two research aspects, biomechanics and energetics. The fundamental biomechanics measurements are continuously recorded vertical forces as exerted by subjects of the treadmill which is instrumented with a force platform. Experimental results indicate that peak vertical force and stride frequency decrease as the gravity level is reduced. Foot contact time is independent of gravity level. Oxygen uptake measurements, VO2, constitute the energetics, or workload, data for this study. As theory predicts, locomotion energy requirements for lunar (1/6-g) and Martian (3/8-g) gravity levels are significantly less than at 1-g. The observed variation in workload with gravity level is nonmonotonic, however, in over half the subject population. The hypothesis is offered that energy expenditure increases for lunar, as compared with Martian, locomotion due to the subject "wasting energy" for stability and posture control in simulated lunar gravity. Biomechanics data could influence advanced spacesuit design and planetary habitat design, while workload data will help define oxygen requirements for planetary life support systems.

Adult↗

Development of a rapid latex enhanced turbidimetric assay for retinol binding protein in urine.

We describe a simple, rapid and sensitive homogeneous immunoassay for urinary retinol-binding protein (RBP) using latex particle-enhanced turbidimetric immunoassay. Rabbit anti-human RBP is covalently coupled to 40 nm latex particles and the assay performed on the IL Monarch 2000 centrifugal analyser, with a 20 microL sample volume and the reaction monitored at 340 nm over an 8 min period. The assay range is 0-6 mg/L with a detection limit of 25 micrograms/L. The within and between assay coefficients of variation are less than 1.5% and less than 2.5%, respectively. Comparison with radioimmunoassay for RBP showed good agreement.

Immunoassay↗