Search PubMedSearch

Biomedical subjects

D J Kitchiner

Publications and source records attributed to D J Kitchiner.

7 recordsLinked to original sources

Comparison of the Sideris and Amplatzer septal occlusion devices.

The results of transcatheter atrial septal defect (ASD) occlusion with 2 different devices (Sideris adjustable buttoned device vs Amplatzer Septal Occluder) were compared in 2 consecutive series of patients. Comparative outcomes were assessed by whether a device was implanted or not, by complications and fluoroscopy time of implantation, and by the incidence of residual shunting on transthoracic echocardiography at follow-up. The patient and defect characteristics were similar in both groups. Twenty-eight of 33 Sideris devices and 37 of 39 Amplatzer devices were implanted. The fluoroscopy time for the Amplatzer implants was 13.4 minutes (range 8 to 41) compared with 23.7 minutes (range 11 to 60.6) for the Sideris implants (p <0.001). The complete occlusion rate for the Amplatzer device was 93% compared with 44% for the Sideris device at 1 year (p <0.001). In conclusion, the Amplatzer device produces higher occlusion rates of ASDs with shorter fluoroscopy times.

Adolescent

Clinical pathways.

Explore the source record for details and available documents.

Critical Pathways

Balloon expandable stents for systemic venous pathway stenosis late after Mustard's operation.

OBJECTIVES: Description and evaluation of current experience with the use of balloon expandable stents for the relief of systemic venous pathway stenosis late after Mustard's operation. DESIGN: Retrospective observational study of technical procedures, angiographic, and haemodynamic findings. PATIENTS: Twenty long term survivors of Mustard's operation for transposition of the great arteries (TGA) with angiographic evidence of systemic venous pathway narrowing. INTERVENTION: Systemic venous pathway stenoses were stented using balloon expandable Palmaz stents. RESULTS: Twenty seven stents were deployed across 24 stenoses. Seventeen stents were placed in the inferior baffle (16 patients), with an increase in mean (range) minimum diameter from 9.6 (4.5-15.9) to 16.5 (11.9-22.2) mm (p = 0.007), and a reduction in mean pressure gradient from 3.1 (0-8) to 0.67 (0-3) mm Hg (p = 0.002). Eight stents were placed in the superior pathways of eight patients, with diameters widened from 9.1 (3.5-14.1) to 15.2 (8.7-19.2) mm (p = 0.018), and gradients reduced from 6.4 (2-11) to 0.9 (0-2) mm Hg (p = 0.02). Two badly deployed stents were safely withdrawn from their intracardiac positions and redeployed in the iliac vein. Transvenous pacemaker insertion was facilitated by prior stent insertion. CONCLUSIONS: The use of balloon expandable stents for late systemic pathway narrowing after Mustard's operation is safe and effective. The beneficial effects of stenting are likely to be more durable than those of balloon angioplasty alone, but longer term follow up is required.

Adolescent

Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils.

OBJECTIVE: To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. DESIGN: Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. SETTING: Tertiary centres for paediatric cardiology. PATIENTS: 71 consecutive patients, aged 1.2-22 years, with a patent ductus arteriosus (PDA) underwent elective transcatheter closure. 45 had native PDAs (group A) with a minimum diameter of 1.0 mm-5.0 mm (median 2.0 mm). A further 26 had undergone one or more previous occlusion attempts (group B). INTERVENTIONS: A total of 133 detachable (Cook) spring coils were successfully implanted in 70 patients. The procedure was performed transvenously in 51 patients, retrograde arterially in 13, and by both routes in a further 6 patients. One 5 mm coil migrated but was successfully retrieved. MAIN OUTCOME MEASURES: In group A colour flow Doppler echocardiography showed that complete occlusion was achieved in 40/45 (89%) at 24 hours, 41/45 (91%) at 1 month, and 44/45 (98%) by 6 months post procedure. Occlusion rates in residual PDAs were 22/25 (88%) occluded at 24 hours, 23/25 (92%) at 1 month, and 24/25 (96%) at 6 months follow up. CONCLUSIONS: Transcatheter occlusion using detachable (Cook) spring coils is a safe and effective alternative to presently available devices. The delivery system allows full retrieval of the coil until a satisfactory position is obtained.

Adolescent

Incidence and prognosis of congenital aortic valve stenosis in Liverpool (1960-1990).

OBJECTIVE: To determine the incidence and prognosis of congenital aortic valve stenosis in the five Health Districts of Liverpool that make up the Merseyside area. DESIGN: The records of the Liverpool Congenital Malformations Registry and the Royal Liverpool Children's Hospital identified 239 patients (155 male, 84 female) born with aortic valve stenosis between 1960 and 1990. Patients were traced to assess the severity of stenosis at follow up. Information on the severity at presentation and all subsequent events was obtained. RESULTS: Congenital aortic valve stenosis occurred in 5.7% of patients with congenital heart disease born in the Merseyside area. The median age at presentation was 16 months (range 0-20 years). Stenosis was mild at presentation in 145 patients, moderate in 33, severe in one and critical in 21 and 39 had a bicuspid valve without stenosis. Additional cardiac lesions were significantly more common in children presenting under one year of age and in those with critical stenosis. The median duration of follow up was 9.2 years (range 1-28 years) and seven patients were lost to follow up. 81 operations were performed in 60 patients. The reoperation rate was 28.3% after a median duration of 8.7 years (range 2.5-18 years). 15% of patients who presented with mild stenosis subsequently required operation compared with 67% of those with moderate stenosis. There were no sudden unexpected deaths and no deaths after aortic valvotomy, except in those presenting with critical stenosis. Mortality was 16.7% but patients presenting with critical aortic stenosis had a much worse prognosis. Actuarial and hazard analysis showed that the survival and absence of serious events (aortic valve surgery or balloon dilatation, endocarditis, or death) were significantly better in patients who presented with mild aortic stenosis than in those who presented with moderate aortic stenosis. 75% of patients presenting with mild stenosis had not progressed to moderate stenosis after 10 years of follow up. CONCLUSIONS: Congenital aortic valve stenosis may be progressive even when it is mild at presentation. Patients presenting with mild stenosis, however, have a significantly better prognosis than those presenting with moderate stenosis. An accurate clinical and echocardiographic assessment of the severity of aortic valve stenosis at presentation provides a good guide to prognosis into early adult life.

Actuarial Analysis