Search PubMed⌕ Search

Biomedical subjects

D J Conces

Publications and source records attributed to D J Conces.

59 records · Page 4Linked to original sources

CT evaluation of normal interatrial fat thickness.

PURPOSE: This study was performed to determine the normal thickness of fat in the interatrial septum as demonstrated by CT. METHOD: Eighty-seven subjects underwent helical chest CT examination as part of a separate protocol to compare the quantification of coronary artery calcification by CT to coronary angiographic findings, using a slice width of 3 mm, reconstructed every 1.5 mm. The thickness of the interatrial fat in both groups was measured anterior and posterior to the fossa ovalis. The mean and standard deviation were calculated. RESULTS: The mean thickness of interatrial fat anterior and posterior to the fossa ovalis was 4.6 (SD = 2.5) and 3.7 (SD = 3.1) mm, respectively. CONCLUSION: The normal range of thickness of the interatrial fat is 0-9.6 mm anterior to and 0-9.9 mm posterior to the fossa (2 SD above the mean).

Adipose Tissue↗

Multisection CT: scanning techniques and clinical applications.

Multisection computed tomography (CT) was introduced in 1992 with the advent of dual-section-capable scanners and was improved in 1998 following the development of quad-section technology. With a recent increase in gantry speed from one to two revolutions per second, multisection CT scanners are now up to eight times faster than conventional single-section helical CT scanners. The benefits of quad-section CT relative to single-section helical CT are considerable. They include improved temporal resolution, improved spatial resolution in the z axis, increased concentration of intravascular contrast material, decreased image noise, efficient x-ray tube use, and longer anatomic coverage. These factors substantially increase the diagnostic accuracy of the examination. The multisection CT technique has enabled faster and superior evaluation of patients across a wide spectrum of clinical indications. These include isotropic viewing, musculoskeletal applications, use of multiplanar reformation in special situations, CT myelography, long coverage and multiphase studies, CT angiography, cardiac scoring, evaluation of brain perfusion, imaging of large patients, evaluation of acute chest pain or dyspnea, virtual endoscopy, and thin-section scanning with retrospective image fusing. Multisection CT is superior to single-section helical CT for nearly all clinical applications.

Equipment Design↗

Normal and abnormal temporomandibular joints as demonstrated by magnetic resonance imaging.

Magnetic resonance imaging of the temporomandibular joint (TMJ) was performed on two normal volunteer subjects and two symptomatic subjects using a 0.15 T resistive magnet. A spin echo pulse sequence with a TE of 38 ms and a TR of 500 ms was employed. The TMJ meniscus is a low signal structure, and the bilaminar zone behind it is a relatively high signal structure. In normal closed mouths, the demarcation between meniscus and bilaminar zone is located at the vertex position above the mandibular condyle. When the condyle translates, the posterior portion of the meniscus bulges into the joint space. Dislocated meniscus can be identified by a gray mass anterior to the condylar head. The joint space is filled with the higher signal of the bilaminar zone. In non-reducible dislocations, the meniscus remains anterior to the condylar head with opening of the mouth. Reduced dislocations appear similar to normal joints in the open mouth.

Cartilage, Articular↗

Comparative ultrastructure of needle aspiration biopsy and surgical resection specimens of lung tumors.

Ultrastructural examination affords conclusive evidence for classification of lung tumors. Tissue properly fixed for electron microscopy is not available in many cases, however. Ultrastructural diagnosis of resected specimens obviously follows, rather than directs, the surgical treatment. Fine-needle aspiration (FNA) of lung masses is recommended as a means to obtain lung tumor tissue for electron microscopy. Nevertheless, no comparison has been made between ultrastructural information gained from aspiration specimens and resected specimens. Electron microscopy was performed on transthoracic FNA specimens of 10 lung tumors for which surgical resection was subsequently performed. Glutaraldehyde-fixed specimens from FNA and surgical resection were prepared for electron microscopy according to routine procedures. Fixation of the FNA specimens was equivalent or superior to that of the resected specimens in 9 of the cases. Three of the FNA specimens contained necrotic as well as viable tissue. Features essential for diagnosis such as desmosomes, junctions, neurosecretory granules, intermediate filaments, glycogen, lipid, mucin, and microvilli were identifiable in both FNA and resected specimens. FNA specimens therefore yield a representative sample of the ultrastructural features of lung tumors when adequate cellular material is obtained. Use of a coaxial needle sampling technique with immediate microscopic assessment reduces the likelihood of retrieving only blood or necrotic tissue in the electron microscopy specimens.

Adult↗