Search PubMed⌕ Search

Biomedical subjects

D J Callans

Publications and source records attributed to D J Callans.

At least 55 records · Page 3Linked to original sources

The results of atrial flutter ablation in patients with and without a history of atrial fibrillation.

To determine the impact of atrial flutter radiofrequency catheter ablation on recurrence of atrial flutter and atrial fibrillation, 32 patients with atrial flutter (18 with a history of atrial fibrillation) were followed for a mean of 8.6 months; atrial flutter has not recurred after 1 (26 patients) or 2 (5 patients) successful ablation procedures. Atrial flutter did not appear proarrhythmic for atrial fibrillation, with only 1 of 15 patients without a history of atrial fibrillation developing the arrythmia in the absence of an alcohol binge or cocaine use.

Atrial Fibrillation↗

The variable contribution of functional and anatomic barriers in human ventricular tachycardia: an analysis with resetting from two sites.

OBJECTIVES: This study sought to investigate the influence of stimulation site on the properties of the circuit in ventricular tachycardia. BACKGROUND: A fully excitable gap can be demonstrated in most human ventricular tachycardias. This requires the presence of an arc of block so that the entire circuit can recover from refractoriness within the period of the cycle length. Resetting characterizes the conduction properties of the tissue within the ventricular tachycardia circuit. Previous studies have not investigated the possibility of site-dependent differences in the resetting response. METHODS: Resetting was performed from the right ventricular apex and outflow tract in 23 patients. Two characteristics of the resetting response were analyzed: 1) the total duration of the flat portion, and 2) the slope of the increasing portion. RESULTS: A flat portion of the resetting response was observed in 18 tachycardias; in 8 of the 18, there was a significant site-dependent difference (> or = 40 ms) in the duration of the flat portion. A significant site-dependent difference in the slope of the increasing portion of the resetting curve was seen in 6 of 22 tachycardias. In all, a stimulation site-dependent change in at least one characteristic of the resetting response was seen in 12 (52%) of the 23 tachycardias. CONCLUSIONS: A stimulation site-dependent change in the flat portion of the resetting response is compatible with an arc of block that is at least partially functional in nature. A change in the slope of the increasing portion is compatible with either partially functional circuit barriers or variation in properties of conduction and refractoriness at different locations within the circuit, or both. These observations suggest that a spectrum of circuit properties may exist in humans, with a variable contribution of anatomic and functional characteristics.

Adult↗

Factors associated with successful implantation of nonthoracotomy defibrillation lead systems.

Two hundred forty-three consecutive patients underwent attempted implantation of nonthoracotomy defibrillation lead (NTL) systems. The importance of clinical and lead-related factors were analyzed regarding their relation with implantation failure caused by an unacceptably high defibrillation threshold (DFT). Overall, 33 (14%) of 243 patients failed NTL implantation. Patients undergoing attempted implantation of NTL systems with monophasic shock waveforms (monophasic group, n = 145) had an incidence of failed implantation of 22% (n = 32) versus an incidence of 1% (n = 1) among patients undergoing attempted implantation by using biphasic shock waveforms (biphasic group, n = 98; odds ratio, 26.9; p < 0.001). The incidence of success and simplicity of implantation of NTL systems was markedly improved in patients undergoing NTL implantation by using biphasic shock waveforms. Clinical factors could be used to stratify patients in the monophasic group for their risk of implantation failure. In the biphasic group, no clinical factor could be correlated with a low DFT with a fully endovascular system.

Aged↗

Idiopathic right ventricular outflow tract tachycardia: narrowing the anatomic location for successful ablation.

Pace mapping used to locate the site for ablation of idiopathic right ventricular outflow tract (RVOT) ventricular tachycardia remains difficult and time-consuming. A method to facilitate pace mapping and the most common site of ablation of this tachycardia are reported. In 18 consecutive patients with RVOT ventricular tachycardia, electrocardiographic criteria based on the QRS orientation in lead 1 and the R wave progression in the precordial leads were used to find pace maps matching the arrhythmia. Identical pace maps were obtained on the septum of the RVOT in 16 patients and resulted in successful ablations. These sites were concentrated in the anterior superior aspect of the RVOT determined by fluoroscopic imaging. In the remaining two cases identical pace maps could not be found in this area. The results of this study narrow the anatomic location for radiofrequency ablation of idiopathic RVOT ventricular tachycardia. This is the first description of an electrocardiography-guided approach to finding an identical pace map in the RVOT.

Adult↗

Effect of bundle branch block on local electrogram morphologic features: implications for arrhythmia diagnosis by stored electrogram analysis.

Analysis of stored local ventricular electrogram recordings is a useful diagnostic tool in the evaluation of patients with implantable cardioverter defibrillators. Visual analysis of local electrogram morphologic features has been demonstrated to be useful in distinguishing ventricular tachycardia from supraventricular rhythm. The effect of bundle branch block (BBB) aberration during supraventricular tachycardia on local electrogram morphologic features is not entirely clear. Erroneous diagnoses resulting from a change in electrogram morphologic features with BBB may occur. To determine whether the development of BBB can produce a change in local electrogram morphologic features and whether this change is dependent on the site of recording, we retrospectively reviewed local electrogram recordings from 23 patients who had intermittent BBB during electrophysiologic evaluation of documented or suspected supraventricular tachycardia. Local electrogram recordings from catheters placed in the right ventricular apex and coronary sinus during supraventricular tachycardia with BBB aberrancy were compared with recordings during narrow complex supraventricular tachycardia or normal sinus rhythm. Bipolar recordings were made with a 5 mm interelectrode distance with filter settings at 40 to 400 Hz. Three independent blinded observers defined the paired electrograms as the same or distinctly different. During right BBB a change in electrogram morphologic features was demonstrated in 11 (85%) of 13 recordings from the right ventricular apex and in only 1 (8%) of 12 recordings from the coronary sinus. In contrast, during left BBB a change in electrogram morphologic features was seen in 6 (100%) of 6 recordings from the coronary sinus and in only 1 (8%) of 13 recordings from the right ventricular apex. These results demonstrate that when the described recording techniques are used, a change in local ventricular electrogram morphologic features BBB is predominantly manifest in recording sites ipsilateral to the BBB, whereas recording sites contralateral to the BBB are relatively unaffected. This information may have implications regarding interpretation of stored electrograms when an attempt is made to establish a rhythm diagnosis leading to implantable cardioverter defibrillator therapy.

Adolescent↗

Radiofrequency catheter ablation of atrial tachycardia with unusual left atrial sites of origin: report of two cases.

Two cases of successful radiofrequency catheter ablation of adult-onset atrial tachycardia originating from the left atrium adjacent to the mitral annulus are presented. Endocardial catheter activation mapping performed by retrograde or atrial transseptal approach revealed presystolic activation at the successful ablation site in both patients, and fractionation during sinus rhythm and tachycardia in one. The 12-lead electrocardiographic P wave appearance was suggestive of a left atrial tachycardia origin in both cases.

Catheter Ablation↗

Bundle branch reentry ventricular tachycardia: an investigation of the circuit with resetting.

We describe a patient with bundle branch reentry ventricular tachycardia with 1:1 VA conduction in whom resetting was performed while obtaining simultaneous recordings from the right ventricular apex (V) and His-bundle electrogram. Both the tachycardia return cycle and the V-His interval demonstrated an increasing reset response, while the His-V interval demonstrated a flat reset response. These reset responses are consistent with a partially excitable gap localizing to the V-His portion of the bundle branch reentry circuit.

Adult↗

Effect of coronary perfusion of heptanol on conduction and ventricular arrhythmias in infarcted canine myocardium.

INTRODUCTION: Abnormal cellular coupling is a major constituent of the slow, dissociated conduction that supports ventricular tachycardia (VT) following myocardial infarction. Agents that modulate cellular coupling may exert either proarrhythmic or antiarrhythmic effects. METHODS AND RESULTS: The effects of modulating cellular coupling on conduction and susceptibility to inducible VT were studied in 11 dogs with healed left anterior descending (LAD) infarction. The LAD circulation was isolated and supplied with arterial blood via a constant-flow bypass system. Localized intracoronary infusion of heptanol, an agent with relatively specific effects on intracellular coupling, was performed using this bypass system. Heptanol produced dose-dependent changes in cardiac conduction, assessed by delayed local activation times in sinus rhythm (0.5 mM: 11.9% +/- 11.0% change, P = 0.005; 1.0 mM: 45.8% +/- 25.5% change, P = 0.0004) and slowed conduction velocity both transverse and longitudinal to fiber orientation. Sustained VT was not induced in any of the control animals. During infusion of 0.5 mM heptanol, uniform sustained VT was inducible in 4 of 11 animals (P = 0.027). During infusion of 1.0 mM heptanol, sustained VT was induced in only 1 of 9 animals. CONCLUSIONS: In the canine model of healed myocardial infarction, heptanol had a bimodal effect on susceptibility to inducible VT. Low-dose heptanol facilitated the induction of sustained VT, and high-dose heptanol had an antiarrhythmic effect. This suggests that agents that modulate coupling may significantly modify susceptibility to VT following myocardial infarction.

Alcohols↗

Effects of high and low shock energies on sinus electrograms recorded via integrated and true bipolar nonthoracotomy lead systems.

INTRODUCTION: The purpose of this investigation was to prospectively evaluate the voltage- and time-dependent characteristics of a biphasic defibrillator discharge on the amplitude of the rate sensing electrogram recorded from two "integrated" and one true bipolar nonthoracotomy lead system. Prolongation of redetection time has been noted after a failed first shock with nonthoracotomy lead systems. However, a prospective evaluation of the time- and voltage-dependent effects of biphasic shocks on electrogram amplitude with clinically utilized lead systems has not been systematically performed. METHODS AND RESULTS: Five- then 30-J R wave synchronous biphasic discharges were delivered during the supraventricular rhythm through three nonthoracotomy lead systems (Medtronic Transvene, Ventritex TVL, and CPI Endotak C 60 Series). The R wave amplitude was measured immediately postshock and for up to 1 minute. Amplitude changes were compared with preshock baseline value. A 5-J discharge had minimal effect on the R wave amplitude recorded from the three lead systems; however, 30 J resulted in significant diminution in R wave amplitude recorded from the integrated bipolar leads (in the Endotak lead to a greater extent than the TVL lead) with minimal effects on the Transvene lead. Following a 30-J discharge, the time constant for R wave recovery was 4.2, 14.9, and 15.3 seconds for Transvene, TVL, and Endotak 60 leads, respectively. CONCLUSION: There are voltage- and time-dependent reductions in postshock R wave amplitude. Integrated bipolar systems appear more affected than the "true" bipolar lead evaluated. This may be due, in part, to lead design, distance of distal defibrillating surface from rate sensing cathode, and the incorporation of the defibrillating surface as the rate sensing anode. The influence of post-shock R wave diminution on subsequent redetection remains speculative but may have implications for subsequent lead development.

Adult↗

Early postoperative rise in defibrillation threshold in patients with nonthoracotomy defibrillation lead systems: attenuation with biphasic shock waveforms.

INTRODUCTION: In patients with non-thoracotomy defibrillation lead (NTL) systems coupled with monophasic shock waveforms, the defibrillation threshold (DFT) rises early after implantation. There is little information regarding features predictive of the DFT rise, or DFT changes early after implantation of NTL systems coupled with biphasic shock waveforms. METHODS AND RESULTS: DFT measurements were performed serially at implantation, prior to hospital discharge (mean 4 +/- 3 days), and at follow-up (mean 49 +/- 22 days) in 146 patients with an NTL system. Factors were assessed for association with a "clinically important" early postimplantation DFT rise, defined as a rise of > or = 2 energy steps (2 to 4 J per step; > or = 5 J total). A clinically important early postimplantation DFT rise occurred in 48 patients (33%). Univariate predictors of the rise included the monophasic shock waveform, the Medtronic Transvene lead system, the presence of a subcutaneous defibrillation patch, and the number of shocks delivered during the implantation procedure. However, the only independent predictor of a clinically important DFT rise was the monophasic shock waveform (F = 18, P < 0.001). For the monophasic patient group (n = 79), the incidence of a DFT rise was 53% (n = 42). For the biphasic patient group (n = 67), the incidence of a DFT rise was 9% (n = 6). The clinical characteristics of the monophasic and biphasic groups were not significantly different, nor were their DFTs at implantation. Among a subgroup of 18 consecutive patients who underwent serial DFT testing utilizing both monophasic and biphasic waveforms, the incidence of a clinically important DFT rise with monophasic (n = 9,50%) was higher than with biphasic shocks (n = 3,17%; P = 0.05). CONCLUSION: NTL systems coupled with biphasic shock waveforms have an attenuated incidence of a clinically important DFT rise early after implantation, relative to patients with NTL systems coupled to monophasic waveforms.

Analysis of Variance↗

Serial defibrillation lead impedance in patients with epicardial and nonthoracotomy lead systems.

INTRODUCTION: The stability of implantable cardiac defibrillation lead impedance subsequent to implantation has not been reported and may have important clinical implications. The objective was to characterize the incidence and degree of impedance changes occurring after implantation of defibrillation lead systems. METHODS AND RESULTS: The study cohort consisted of patients who received epicardial or nonthoracotomy lead systems. Defibrillation impedance was recorded at implantation, prior to hospital discharge (predischarge), and during follow-up. For each individual the magnitude of the impedance change relative to implantation was characterized. Among patients with an epicardial system, a significant decrease in impedance was observed at predischarge (mean 9.3 omega). The magnitude of the decrease was large in 39% and moderate in 31% of individuals. Subsequently, a gradual rise in mean impedance was apparent. At 18-21 months postimplantation, impedance was significantly increased relative to implantation (mean 6.8 omega). At this time, the magnitude of the increase was large in 46% and moderate in 23% of patients. Among patients with a nonthoracotomy lead system including a subcutaneous patch, a significant decrease in mean impedance was observed at predischarge (mean 3.5 omega). The magnitude of the decrease was large in 8% and moderate in 50% of individuals. Subsequently, a gradual rise in impedance was apparent. At 5-6 months, it was significantly increased relative to implantation (mean 2.3 omega). The magnitude of the increase was large in 10% and moderate in 33% of patients. Among the group of patients whose nonthoracotomy lead system did not include a subcutaneous patch, there was no significant change in mean impedance at predischarge relative to implantation. In subsequent intervals, a gradual rise was apparent. At 5-6 months, impedance was significantly increased relative to implantation (mean 4.3 omega). The magnitude of the increase was large in 16% and moderate in 47% of individuals. CONCLUSION: Significant changes in defibrillation lead impedance occur after implantation of epicardial and nonthoracotomy defibrillation lead systems. These data may serve as a standard for identifying the anticipated maximum change in lead impedance and thus may be useful as a tool for recognizing problems with defibrillation lead integrity.

Defibrillators, Implantable↗

Insights into the electrophysiology of accessory pathway-mediated arrhythmias provided by the catheter ablation experience: "learning while burning, part III".

The success of catheter ablation has greatly improved the care of patients with paroxysmal tachycardias and has caused a revolution in the practice of electrophysiology. Some investigators have expressed that concern over procedural success in an increasingly interventional specialty threatens to eclipse attempts to understand the physiology of arrhythmia syndromes. Alternatively, due to the precise and directed nature of the lesions created with radiofrequency energy, catheter ablation procedures have allowed investigation to continue at a more focused level. In this article, the insights provided by the catheter ablation experience into the physiology of arrhythmias mediated by accessory AV pathways will be reviewed. Although the learning process was sometimes delayed by the nearly immediate success of radiofrequency catheter ablation, difficult situations have continued to renew efforts for understanding at a deeper level. Conscious attempts at "learning while burning" will provide the opportunity to investigate aspects of bypass tract physiology that remain incompletely characterized, such as partial response to therapy and late recurrence.

Animals↗

Ventricular tachycardia: progress in acute and chronic patient care.

Patients with ventricular tachycardia (VT) typically have significant structural heart disease and therefore benefit from all advances made in the past 50 years in cardiovascular care. Once sinus rhythm is restored, subsequent treatment goals include detecting the primary causes of VT and treating acute recurrences, determining the extent of structural heart disease and assessing the need for treatment of heart failure and ischemia, and prescribing chronic antiarrhythmic therapy. Implantable-device therapy has revolutionized the treatment of patients with VT.

Acute Disease↗

Circadian variation of ventricular arrhythmia recurrences after cardioverter-defibrillator implantation in patients with healed myocardial infarcts.

Past studies using Holter monitoring and retrospective reviews of death certificates have documented peak occurrence of sudden death and nonsustained ventricular tachycardia (VT) in the morning hours. We used the Ventritex Cadence device (Ventritex, Sunnyvale, California) which documents the date and time of all stored arrhythmias leading to device therapy to evaluate the circadian pattern of sustained ventricular arrhythmia recurrence. Mean follow-up after defibrillator implantation was 628 +/- 285 days. All 390 patients had at least 1 episode (range 1 to 43) of sustained VT documented from analysis of the stored electrograms associated with an arrhythmia event. Stored electrograms were available for review and analysis in 3,041 device detections; 349 stored events were excluded because they did not fulfill the diagnostic criteria for VT or failed to document the onset of the ventricular arrhythmia at the beginning of the recorded event of the arrhythmia episode. Criteria for the diagnosis of VT or ventricular fibrillation were met in 2,692 arrhythmia episodes occurring in 390 patients. There was circadian variation for ventricular arrhythmia recurrence for the whole patient group with the data fit to the sinusoidal density function: f(t) = 126 - 51 x cos (-57 + 2 pi t/24) - 25 x sin (63 + 2 pi t/12) (p < 0.0001). Ventricular arrhythmia occurrence rate was lowest between 2:00 and 3:00 A.M., and highest between 10:00 and 11:00 A.M. In addition, the same circadian pattern was demonstrated regardless of patient age, gender, left ventricular ejection fraction (< 35% or > or = 35%), and VT cycle length (< 300 or > or = 300 ms).(ABSTRACT TRUNCATED AT 250 WORDS)

Age Factors↗

Characterization of return cycle responses predictive of successful pacing-mediated termination of ventricular tachycardia.

OBJECTIVES: The purpose of this study was to characterize response patterns during overdrive pacing that predict successful termination of ventricular tachycardia. BACKGROUND: Overdrive pacing during ventricular tachycardia typically results in entrainment at slow pacing rates and in termination or acceleration at faster rates. The factors that determine the critical paced cycle length that results in tachycardia termination have not been extensively studied. METHODS: Ventricular tachycardias in 14 patients with coronary artery disease were studied with overdrive pacing at several cycle lengths. Return cycles were measured after each additional paced beat at each paced cycle length. The return cycle responses during pacing trials that resulted in tachycardia termination and those that resulted in entrainment were compared. RESULTS: Three return cycle responses were identified: flat, plateau and increasing. Twenty trials of overdrive pacing resulted in tachycardia termination; all were characterized by an increase in the return cycle with the delivery of each successive beat in the pacing drive until the tachycardia terminated (increasing response). Thirty-four pacing trials resulted in entrainment and not termination; these were characterized either by a constant return cycle (flat response) or an initial increase in return cycle followed by a longer, constant return cycle (plateau response) with the delivery of additional paced beats. The longest paced cycle length that resulted in tachycardia termination correlated with the relative refractory period of the circuit, defined as the tachycardia cycle length minus the fully excitable gap (r2 = 0.764, p = 0.0001). Tachycardia termination was not observed unless the paced cycle length was shorter than the relative refractory period of the circuit. CONCLUSIONS: The critical paced cycle length that causes termination of ventricular tachycardia depends on the relative refractory period of the circuit because this factor determines whether the nth + 1 beat of the pacing drive will encounter partially recovered tissue. These data provide insights into the mechanism of pacing-mediated tachycardia termination and entrainment and are applicable to the development of improved antitachycardia pacing algorithms.

Aged↗

Comparison of initial detection and redetection of ventricular fibrillation in a transvenous defibrillator system with automatic gain control.

OBJECTIVES: The purpose of this study was to prospectively evaluate postshock redetection of ventricular fibrillation by a system that coupled an implantable cardioverter-defibrillator with an automatic gain control sense amplifier and a transvenous lead system. BACKGROUND: Redetection of ventricular fibrillation after an unsuccessful first shock has not been systematically evaluated. Previous studies have suggested that sensing performance of some lead systems may be adversely affected by the delivery of subthreshold shocks. METHODS: The time required for both initial detection and redetection of ventricular fibrillation was compared in 22 patients. These times were estimated by subtracting the capacitor charge time from the total event time. RESULTS: A total of 113 successful and 57 unsuccessful initial shocks were delivered during induced ventricular fibrillation. The mean +/- SD initial time to detection of ventricular fibrillation was 5.5 +/- 1.7 s (range 2.4 to 10.8); the time to redetection ranged from 1.5 to 18.5 s (mean 4.5 +/- 2.8, p = NS vs. detection time). Abnormal redetection episodes, defined as a redetection time > 10.2 s (i.e., > 2 SD above the mean redetection time), were observed in 4 (18%) of 22 patients. CONCLUSIONS: Redetection of ventricular fibrillation after a subthreshold first shock may be delayed. Device testing with intentional delivery of subthreshold shocks to verify successful postshock redetection of ventricular fibrillation should be performed routinely in all patients.

Algorithms↗