Search PubMed⌕ Search

Biomedical subjects

D J Berry

Publications and source records attributed to D J Berry.

At least 19 recordsLinked to original sources

Decrease in particle-induced osteolysis in obese (ob/ob) mice.

There may be variability in the susceptibility of different individuals to osteolysis from wear debris, and it is not clear whether some individuals may have a genetic predisposition for a more marked osteolytic response. The purpose of this study in mice was to determine whether genetically determined obesity can alter the response to particulate debris. Polyethylene particles were implanted onto the calvaria of seven wild-type mice and seven obese mice (ob/ob). Calvaria from unimplanted wild-type and obese mice served as controls. Calvaria were harvested after 7 days, stained with toluidine blue and for tartrate-specific alkaline phosphatase, and analyzed by histomorphometry. The osteoclast number per mm total bone perimeter was 8.000+/-3.464 in wild-type animals with particles and 2.857+/-1.676 in ob/ob animals with particles (p=0.002; Fisher's PLSD). Bone resorption was 1.895+/-0.713 mm/mm(2) in wild-type animals with particles and 1.265+/-0.494 mm/mm(2) in ob/ob animals with particles (p=0.0438; Fisher's PLSD). Particles induced a diminished osteolytic response in genetically determined obese mice, suggesting that obesity may have a protective role against particle-induced bone resorption-similar to obesity and osteoporosis. These important new findings may help to stimulate clinical studies which may define criteria to better identify patients at risk to develop particle-induced osteolysis.

Animals↗

In vivo evaluation of novel hyaluronan/chitosan microparticulate delivery systems for the nasal delivery of gentamicin in rabbits.

Biodegradable microparticles containing gentamicin were prepared using chitosan hydroglutamate (CH), hyaluronic acid (HA) and a combination of both polymers by a solvent evaporation method. These formulations were administered nasally via an insufflator. Gentamicin was also administered nasally into rabbits as a solution and powder (a physical mixture of gentamicin and lactose), intravenously (IV) and intramuscularly (IM). The resultant serum levels of gentamicin were determined by Fluorescence Polarisation Immunoassay (FPIA). The bioavailability of gentamicin was poor when administered as a nasal solution (1.1%) and dry powder (2.1%) when compared with IV. However, the microparticulate systems composed of CH and HA/CH considerably enhanced the bioavailability of gentamicin (31.4 and 42.9%, respectively,) with HA microparticles inducing a less significant enhancement (23.3%). Previous in vitro dissolution and frog palate studies indicated that these microparticulate formulations were all mucoadhesive and demonstrated prolonged drug release. Such findings were translated into an increase in the bioavailability of gentamicin when compared with a simple nasal solution in vivo. When HA and CH were combined in the HA/CH formulation, the polymers appeared to improve the absorption of incorporated gentamicin synergistically in comparison to the individual polymers, suggesting a promising nasal delivery system.

Adjuvants, Pharmaceutic↗

Epidemiology of instability after total hip replacement.

This article reviews the epidemiology of dislocation after total hip arthroplasty. The overall prevalence, prevalence as a function of time after arthroplasty, and prevalence of recurrent dislocation are reviewed. Risk factors for dislocation are reviewed according to patient characteristics, implant design characteristics, and factors related to surgical technique.

Arthroplasty, Replacement, Hip↗

Primary uncemented total hip arthroplasty in patients <40 years old: 10- to 14-year results using first-generation proximally porous-coated implants.

Eighty-two consecutive primary first-generation uncemented total hip arthroplasties (72 patients) performed in patients <40 years old were reviewed with minimum follow-up of 10 years. Of 82 hips, 24 (29.3%) have been revised to date. The estimated survival free of aseptic revision or radiographic failure was 81.3% at 10 years for the acetabular components. The estimated survival free of aseptic revision or radiographic failure was 84.9% at 10 years for the femoral component. In this exclusively young patient cohort, there was a high failure rate of the acetabular component and the femoral component. The data in this report can serve as a baseline for comparison of newer implants and operative methods.

Adolescent↗

Total knee arthroplasty using cruciate-retaining kinematic condylar prosthesis.

The purpose of the current study was to evaluate the long-term results of the Kinematic I condylar prosthesis with retention of the posterior cruciate ligament. One hundred sixty-eight total knee arthroplasties in 118 patients (mean age, 65.2 years; range, 21-88 years) were inserted with cement, an all-polyethylene patella, metal-backed tibia, and posterior cruciate ligament retention. Sixty-one patients (86 knees) died, one patient had an above-knee amputation, and three patients (five knees) were lost to followup; therefore, 66 knees (excluding revisions) in 50 patients were available for followup at a mean of 15.7 +/- 1.1 years (range, 14-20 years). Of the entire cohort of 168 knees, 13 have been revised: one for medial femoral condyle fracture, one for tibiofemoral instability, one for femoral and two for tibial component aseptic loosening, four for tibial polyethylene wear, and four for patellar component aseptic loosening. The 15-year survivorship free of any component revision excluding infections was 88.7% (confidence interval, 82%-95%). The 15-year survivorship free of radiographic loosening and/or revision of any component was 85.1% (confidence interval, 78%-92%). The current study shows good function and survivorship of the posterior cruciate-sparing Kinematic I condylar prosthesis at a mean of 15.7 +/- 1.1 years.

Adult↗

Surveillance for venous thromboembolic disease after total knee arthroplasty.

The value of deep venous thrombosis screening after total knee arthroplasty is controversial. The purpose of the current study was to examine the value of routine surveillance for venous thrombosis after total knee arthroplasty done with modern operative and perioperative treatment. Computerized search engines were used to identify papers published between 1985 and July 2000 relevant to the purpose of the study. Papers that met the inclusion criteria for review were categorized as follows: the frequency of deep venous thrombosis; the natural history of deep venous thrombosis; the accuracy of screening methods for venous thrombosis; and efficacy of screening in reducing morbidity attributable to venous thromboembolism after total knee arthroplasty. Several studies have shown a low complication rate related to venous thromboembolic disease when compression ultrasound is used for screening as part of a clinical algorithm after knee arthroplasty. However, the only large prospective randomized trial evaluating ultrasound screening failed to show a reduction in morbidity with a surveillance protocol. The benefits of surveillance depend on factors specific to each surgeon's practice including the type and duration of venous prophylaxis, the rate of symptomatic and asymptomatic thromboembolic disease associated with that protocol, and the accuracy of screening tests used for surveillance.

Arthroplasty, Replacement, Knee↗

Methsuximide reduces valproic acid serum levels.

The authors investigated whether methsuximide affects serum levels of valproic acid. Pre-morning-dose serum valproic acid levels were measured in 17 patients (12 male, 5 female; age range, 8-19; mean, 14.5 years) who either started or stopped taking methsuximide but whose dose of valproate and other medication remained unchanged. Four of these patients both started and stopped taking methsuximide. For the whole group the mean valproic acid level (+/- standard error) while not taking methsuximide was 81.9 +/- 5.3 mg/L and while taking methsuximide was 55.7 +/- 4.3 mg/L. The difference between the means was highly significant (paired t test, p < 0.001). The mean valproic acid serum level before taking methsuximide was 85.4 +/- 4.5 mg/L (14 patients), which decreased to 58.2 +/- 4.8 mg/L while taking methsuximide (difference highly significant, p < 0.001). In the eight patients who stopped taking methsuximide the mean serum level increased from 49.8 +/- 7.5 mg/L to 71.7 +/- 8.5 mg/L (difference significant p = 0.025). Because methsuximide reduces valproic acid serum levels, it may be necessary to increase the valproate dose when methsuximide is added or reduce the valproate dose when methsuximide therapy stops, to avoid loss of seizure control or valproate toxicity respectively.

Adolescent↗

Reverse obliquity fractures of the intertrochanteric region of the femur.

BACKGROUND: The reverse obliquity fracture of the proximal part of the femur is a distinct fracture pattern that is mechanically different from most intertrochanteric fractures. The purpose of this retrospective study was to determine the prevalence of these fractures and the results and complications of different types of internal fixation used in their treatment. METHODS: Between 1988 and 1998, 2472 consecutive patients with a hip fracture were treated at our Level-One Trauma Center; 1035 of the fractures were classified as intertrochanteric or subtrochanteric. Clinical and radiographic records were retrospectively reviewed, and fifty-five fractures with a reverse obliquity pattern were identified. Forty-nine patients were followed until the fracture united or a revision operation was performed. The duration of clinical follow-up averaged eighteen months (range, three to sixty-seven months), and the duration of radiographic follow-up averaged fifteen months (range, three to sixty months). Fractures were classified with the Orthopaedic Trauma Association scheme. Results were analyzed according to the fracture pattern, type of implant, quality of the reduction, position of the implant, and use of bone graft at the index operation. Function was assessed on the basis of pain, living situation, need for walking aids, need for analgesics, and walking capacity. RESULTS: Thirty-two (68%) of forty-seven hips treated with internal fixation healed without an additional operation. Fifteen (32%) of the forty-seven failed to heal or had a failure of fixation. The failure rate was nine of sixteen for the sliding hip screws, two of fifteen for the blade-plates, three of ten for the dynamic condylar screws, one of three for the cephalomedullary nails, and zero of three for the intramedullary hip screws. Use of the fixed-angle devices (the blade-plate and the dynamic condylar screw) resulted in fewer failures than did use of the sliding hip screw (p = 0.023). Eleven (46%) of twenty-four nonanatomically reduced fractures and four (17%) of twenty-three anatomically reduced fractures had a failure of treatment (p = 0.060). Eleven (26%) of forty-two fractures with an ideally placed implant and four (80%) of five fractures with a non-ideally placed implant had a failure of treatment (p = 0.023). Of the fifteen fractures that failed to heal or had a failure of fixation, five were treated with revision to a calcar-replacement prosthesis, seven were treated with revision open reduction and internal fixation with bone-grafting, and one was treated with bone-grafting without revision of the fixation. Two patients refused additional surgery because they had limited functional demands. The two-year mortality rate was 33%. Functional results were poor, with many patients requiring walking aids and losing the capacity for independent walking and self-care. CONCLUSIONS: In this series, reverse obliquity fractures accounted for 2% of all hip fractures and 5% of all intertrochanteric and subtrochanteric fractures. Ninety-five-degree fixed-angle internal fixation devices performed significantly better than did sliding hip screws. Results were also worse for fractures with poor reduction and those with a poorly placed implant.

Bone Screws↗

Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty.

BACKGROUND: Extra-large uncemented components provide several advantages for acetabular revision, but limited information is available on the results of their use. The purpose of this study was to evaluate, at a minimum of five years, the results associated with the use of an extra-large uncemented porous-coated component for acetabular revision in the presence of bone loss. METHODS: Eighty-nine extra-large uncemented hemispherical acetabular components were used for revision after aseptic failure of a total hip arthroplasty in forty-six men and forty-three women (mean age at revision, fifty-nine years; range, thirty to eighty-three years). The revision implant (a Harris-Galante-I or II cup fixed with screws) had an outside diameter of > or = 66 mm in men and > or = 62 mm in women. Seventy-nine patients had a segmental or combined segmental and cavitary acetabular bone deficiency before the revision. Particulate bone graft was used in fifty-four hips and bulk bone graft, in nine. RESULTS: One patient died with the acetabular component intact and two patients were lost to follow-up within five years after the operation. At the time of the last follow--up, four acetabular components had been removed or revised again (two for aseptic loosening). All of the remaining patients were followed clinically for at least five years (mean, 7.2 years; range, 5.0 to 11.3 years). In the hips that were not revised again, only two sockets had definite radiographic evidence of loosening. All four of the sockets that loosened were in hips that had had combined cavitary and segmental bone loss preoperatively. In the hips that were not revised again, the mean modified Harris hip score increased from 56 points preoperatively to 83 points at the time of the most recent follow-up. The most frequent complication, dislocation of the hip, occurred in eleven patients. The probability of survival of the acetabular component at eight years was 93% (95% confidence interval, 85% to 100%) with removal for any reason as the end point, 98% (95% confidence interval, 92% to 100%) with revision for aseptic loosening as the end point, and 95% (95% confidence interval, 88% to 100%) with radiographic evidence of loosening or revision for aseptic loosening as the end point. CONCLUSIONS: This study demonstrates that extra-large uncemented components used for acetabular revision in the presence of bone loss perform very well and have a low rate of aseptic loosening at the time of intermediate-term follow-up.

Acetabulum↗

Uncemented acetabular components with bulk femoral head autograft for acetabular reconstruction in developmental dysplasia of the hip: results at five to twelve years.

BACKGROUND: Anterolateral acetabular bone deficiency is one of the technical problems associated with total hip arthroplasty in patients with developmental hip dysplasia. The purpose of this study was to evaluate the results of one method of acetabular reconstruction for hip dysplasia-placement of an uncemented socket in conjunction with a bulk femoral head autograft. METHODS: Forty-four hips in thirty-five patients (twenty-nine female and six male; average age, thirty-nine years) with developmental hip dysplasia were treated with primary total hip arthroplasty with use of an uncemented porous-coated titanium cup fixed with screws and an autogenous bulk femoral head graft. The patients were followed clinically in a prospective fashion for five to 12.3 years (mean, 7.5 years), and radiographs were analyzed retrospectively. RESULTS: Four acetabular components were revised: two, because of severe polyethylene wear and osteolysis; one, because of aseptic loosening; and one, because of fracture of the acetabular shell. The mean Harris hip score for the unrevised hips improved from 51 points preoperatively to 91 points postoperatively. No unrevised socket had definite radiographic evidence of loosening. Forty-three of the forty-four hips had no radiographic evidence of resorption of the graft or had radiographic evidence of resorption limited to the nonstressed area of the graft lateral to the edge of the cup. CONCLUSIONS: This method of reconstruction provided reliable acetabular fixation and appeared to restore acetabular bone stock in patients with developmental hip dysplasia. We use this technique for patients with moderate anterolateral acetabular bone deficiency requiring total hip arthroplasty.

Acetabulum↗

Unstable total hip arthroplasty: detailed overview.

Hip dislocation is one of the most common complications of THA. Good preoperative planning, good postoperative patient education, accurate intraoperative component positioning, rigorous intraoperative testing of hip stability, and good repair of soft tissues during closure all help prevent dislocation. Early postoperative dislocations and first or second dislocations usually are treated with closed reduction and a hip guide brace or hip spica cast, but when dislocation becomes recurrent, surgical treatment usually is needed. When possible, surgical treatment is based on identifying and treating a specific problem leading to the dislocation, such as implant malposition, inadequate soft-tissue tension, or impingement. In selected circumstances, constrained implants or bipolar or tripolar implants provide powerful tools to restore hip stability.

Adult↗

Preparation and evaluation of the in vitro drug release properties and mucoadhesion of novel microspheres of hyaluronic acid and chitosan.

Rapid mucociliary clearance of intranasally administered drugs is often a key factor in determining the bioavailability of such therapeutic agents. The use of mucoadhesive microparticles provide a potential strategy for improving retention of drugs within the nasal cavity, and thereby improve the resultant pharmacokinetic profile. This study describes the comparison of a number of novel, potentially mucoadhesive microspheres, prepared by solvent evaporation, composed of hyaluronic acid (HA), chitosan glutamate (CH) and a combination of the two with microcapsules of HA and gelatin prepared by complex coacervation. The microspheres had a mean particle size of 19.91+/-1.57 microm (HA), 28.60+/-1.34 microm (HA/CH), 29.47+/-3.58 microm (CH). The incorporation of a model drug, gentamicin sulphate (%) was 46.90+/-0.53 (HA), 28.04+/-1.21 (HA/CH) and 13.32+/-1.04 (CH). The in vitro release profiles of microsphere formulations prepared by solvent evaporation were determined. The release of gentamicin from HA and HA/CH was 50% longer than CH and was best modelled as a release from a matrix. The degree of mucoadhesion of each formulation was investigated by determining the mucociliary transport rate (MTR) of the microparticles across an isolated frog palate. Acacia/gelatin microcapsules were used as a positive control. The rank order of mucoadhesion for the microspheres and the microparticles was HA=HA/CH>CH>HA/gelatin>CHins. The entrapment of gentamicin did not affect the mucoadhesive properties (P>0.05, Mann--Whitney U-test). The combination of HA with chitosan may afford additional advantages in combining the mucoadhesive potential of HA with the penetration enhancing effect of chitosan.

Acacia↗

Acute periprosthetic fracture of the acetabulum associated with osteolytic pelvic lesions: a report of 3 cases.

Three cases of acute acetabular fracture around uncemented porous-coated acetabular components associated with osteolytic lesions of the pelvis are reported. In each case, the fracture occurred through an area of severe osteolysis that contributed to the structural failure of the pelvis. None of the fractures were associated with significant trauma, and none of the implants demonstrated evidence of loosening before the fracture. When marked pelvic osteolysis develops around the acetabular component of a total hip arthroplasty, the possibility of pelvic fracture must be considered. Total hip arthroplasty patients with osteolysis should be followed with radiographs at regular and frequent intervals. When osteolysis progresses, early intervention should be strongly considered because appropriate treatment may prevent fracture occurrence.

Acetabulum↗

Long-term survivorship of cemented all-polyethylene acetabular components in patients > 75 years of age.

Between 1974 and 1982, 132 consecutive hips in 112 patients >75 years of age were treated with primary total hip arthroplasty for osteoarthritis using a cemented all-polyethylene T28 socket and cemented T28 or TR28 stem with a 28-mm head size. At the time of review, 94 patients (110 hips [83%]) had died and 18 patients (22 hips [17%]) were still living (mean age at follow-up, 93 years). Five hips (5 patients) were lost to follow-up. Clinical follow-up averaged 8.9 years for the entire group and 14.6 years for patients still living. Only 2 acetabular components have been revised (1 for recurrent dislocation, 1 for infection). No acetabular component has required revision for aseptic loosening. Survivorship free of acetabular revision for aseptic loosening at 10 years was 100%; free of symptomatic acetabular loosening, 97.4% (95% confidence interval, 91.8-100%); and free of acetabular loosening, 95.9% (95% confidence interval, 89.7-100%). The commonest complication was postoperative hip dislocation, which occurred in 11 hips (8.7%) and which required reoperation in 2 hips. Cemented acetabular components implanted in patients >75 years of age with a diagnosis of osteoarthritis showed a high rate of survivorship free of revision and free of symptomatic aseptic loosening.

Acetabulum↗

Bilobed oblong porous coated acetabular components in revision total hip arthroplasty.

Thirty-eight oblong bilobed noncustom uncemented, porous-coated titanium acetabular components were used to reconstruct failed hip arthroplasties with large superior segmental acetabular bone deficiencies. No structural bone grafts were used. All patients were followed up for 2 to 5 years (mean, 3 years) after the operation. One patient (whose socket rested primarily on a structural bone graft from a previous procedure) had revision surgery for acetabular loosening. No other patients have had revision surgery or had another ipsilateral hip operation. At latest followup, 35 patients had no or mild pain and two patients had moderate pain. Two implants migrated more than 2 mm in the first year, then stabilized. On the latest radiographs, two implants had bead shedding, but there was no measurable migration or change in position. For selected patients with large superolateral acetabular bone deficiencies, this implant facilitated a complex reconstruction, provided good clinical results, and showed satisfactory stability at early to midterm followup in most patients.

Acetabulum↗