Deposits on the optical surfaces of Hydroview intraocular lenses.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D J Apple.
Explore the source record for details and available documents.
PURPOSE: To evaluate fibronectin, vitronectin, laminin, and collagen type IV adhesion to poly(methyl methacrylate) (PMMA), silicone, hydrophobic soft acrylate, and hydrogel intraocular lenses (IOLs) in human pseudophakic autopsy eyes. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Thirty-two autopsy eyes containing PMMA, silicone, soft acrylate, or hydrogel IOLs were assessed. The IOLs were explanted from the capsular bag, and both sides of the IOLs were immunohistochemically stained for fibronectin, vitronectin, laminin, or collagen type IV. The number of cells on the IOL surfaces was counted. The capsular bag from 1 eye containing a soft acrylate IOL was examined for fibronectin and vitronectin. RESULTS: Hydrophobic soft acrylate IOLs had significantly more fibronectin adhering to their surfaces than PMMA (P <.01) or silicone (P <.01) IOLs, as well as more vitronectin. Silicone IOLs had more collagen type IV adhesion than the other IOLs (P <.05-.06). Collective protein adhesion differed significantly between soft acrylate IOLs and PMMA and silicone IOLs, but not between PMMA and silicone IOLs. CONCLUSIONS: The greater amount of protein on the hydrophobic soft acrylate (AcrySof(R)) IOLs seems to support an adhesive mechanism for their attachment to the capsular bag. Fibronectin and vitronectin have functional domains to bind them to lens epithelial cells and the collagenous capsule. This kind of attachment could be a true bioactive bond and may be 1 reason the PCO and neodymium:YAG capsulotomy rates are lower in eyes with a soft acrylate IOL.
PURPOSE: To evaluate fibronectin, vitronectin, laminin, and collagen type IV adhesion to poly(methyl methacrylate) (PMMA), silicone, hydrophobic soft acrylate, and hydrogel intraocular lenses (IOLs) in pseudophakic human autopsy eyes. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Thirty-eight autopsy eyes containing PMMA, silicone, hydrophobic acrylate, or hydrogel IOLs were assessed. Histological sections were prepared from each eye, and immunohistochemical analyses were performed for fibronectin, vitronectin, laminin, and collagen type IV. One hundred fifty-two specimens were analyzed. RESULTS: A sandwich-like structure (anterior or posterior capsule/fibronectin/1 cell layer/fibronectin/IOL surface) was seen in 12 of 14 autopsy eyes with soft acrylate IOLs, 3 of 10 with a PMMA IOL (P =.0094), 1 of 10 with a silicone IOL (P =.0022), and 0 of 4 with a hydrogel IOL (P =. 0041). The thicker fibrocellular tissue on the inner surface of the anterior or posterior capsule that was in contact with silicone IOLs was lined with collagen type IV. Vitronectin and laminin were not found at the fibrocellular tissue-IOL interface in any specimen. CONCLUSIONS: This study seems to confirm the sandwich theory of posterior capsule opacification in eyes with an IOL and suggests that fibronectin may be the major extracellular protein responsible for the attachment of hydrophobic soft acrylate (AcrySof(R)) IOLs to the capsular bag. This may represent a true bioactive bond between the IOL and lens epithelial cells or between the IOL and the capsular bag and may be one reason the PCO and neodymium:YAG capsulotomy rates are lower in eyes with a soft acrylate IOL.
PURPOSE: To emphasize an important aspect of preventing posterior capsule opacification (PCO), the barrier effect established by the optic of a posterior chamber intraocular lens (PC IOL), and present a new classification regarding capsular bag status after extra-capsular cataract extraction, including phacoemulsification. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: This analysis included 150 consecutive eyes obtained postmortem with United States-manufactured PC IOLs including (1) poly(methyl methacrylate), (2) silicone, and (3) hydrophobic acrylic designs that were accessioned in the Center from September 1995 to January 1, 1998. Gross photographs from behind (Miyake-Apple views) were taken and serial histologic sections prepared. RESULTS: Microscopic analysis of the 150 eyes showed that the morphologic appearance of the capsular bag could be grouped into 2 categories: (1) those with little or no evidence of retained cortical material and cells, and (2) those with retained cortical material and cells in which a Soemmering's ring formed. With the latter, when a distinct barricade to cellular migration created by the IOL optic was noted, 2 discrete configurations occurred, depending on the different geometries of the optic components. With a classic biconvex optic with a curved and tapered edge, in many instances some ingrowth of cells proceeded posteriorly around the edge of the IOL optic in the direction of the central axis. With a lens optic that had a squared, truncated, and relatively thick edge, there was often abrupt termination of cells at the peripheral edge of the optic. The posterior capsule subtending the entire optic zone was therefore relatively or totally cell free. CONCLUSIONS: The barrier effect of the IOL optic appears to be of critical importance in retarding ingrowth of cells, functioning as a second line of defense when cortical cleanup is incomplete. Analysis of PC IOLs obtained postmortem showed that a square, truncated optic edge seemed to provide the maximum impediment to cell growth behind the IOL optic.
PURPOSE: To evaluate over almost 2 decades the success of a component of cataract surgery that represents a critical step in reducing the incidence of posterior capsule opacification (PCO); namely, the efficacy of cortical cleanup. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Accessioned from the early 1980s to 1997, 3320 eyes obtained postmortem with posterior chamber intraocular lenses were analyzed with respect to formation of a postoperative Soemmering's ring. This anatomic lesion, the precursor of clinical PCO, represents an important and measurable indication of the quality of cortical cleanup. Its formation was documented using Miyake-Apple posterior photographic analysis. RESULTS: The quality and thoroughness of cortical cleanup and overall effectiveness in eliminating retained and/or regenerating cortical cells, as measured by scoring of Soemmering's rings, showed virtually no net change since the early 1980s. The intensity of Soemmering's ring was higher in the most recent specimens than in those in the early 1980s. CONCLUSION: The results indicate that renewed attention to cortical cleanup in cataract surgery is warranted for significant reduction in incidence or the elimination of PCO. More attention to the hydrodissection (cortical cleaving hydrodissection) step of the procedure is likely a practical, immediately implementable, and inexpensive remedy.
PURPOSE: To experimentally analyze the role and efficacy of hydrodissection in achieving maximal cortical cleanup. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Phacoemulsification and irrigation/aspiration were performed in 10 pairs of human eyes (20 eyes) obtained postmortem. Ten eyes had previous hydrodissection and 10 eyes, no hydrodissection. The time (seconds) required for complete lens substance removal in each procedure was measured. In addition, a qualitative evaluation of difficulty of surgery was noted. RESULTS: Phacoemulsification required 28.6% less time in eyes with previous hydrodissection than in those without. Irrigation/aspiration time was reduced by 50.9% when hydrodissection was performed. The total time of each procedure required for complete evacuation of the capsular bag was reduced by an average of 37.7% in eyes with hydrodissection. Furthermore, qualitatively the procedure was far easier, less stressful, and caused less posterior capsule stress or rupture when copious hydrodissection was performed. CONCLUSIONS: Hydrodissection enhances the general safety and efficiency of cortical cleanup, especially at 12 o'clock. Hydrodissection is the best available, practical, immediately implementable, and inexpensive means to help remove equatorial E-cells and thus alleviate the incidence of posterior capsule opacification.
We describe a method to harden the nucleus of crystalline lenses in postmortem human globes by intralenticular injection of a mixture of paraformaldehyde and glutaraldehyde (Karnovsky's solution). Evaluation of the nuclear manipulations, using the Miyake-Apple posterior video/photographic technique, shows that the method provides suitable specimens for practicing extracapsular cataract extraction and phacoemulsification.
PURPOSE: To present a clinicopathological correlation of 2 pairs of piggyback posterior chamber intraocular lenses (PC IOLs) explanted because of opacification between the lens optics. SETTING: Gayton Health Center, Eyesight Associates of Middle Georgia, Warner Robins, Georgia, and Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Two pairs of piggyback AcrySof lenses were explanted from 2 patients with significant visual loss related to opacification between the optics. They were submitted for pathological analysis. Gross and histopathological examinations were performed, and photomicroscopy was used to document the results. RESULTS: Gross examination showed accumulation of a membrane-like white material between the lenses. Histopathological examination revealed that the tissue consisted of retained/proliferative lens epithelial cells (bladder cells or pearls) mixed with lens cortical material. CONCLUSION: Piggyback PC IOLs were explanted in 2 cases because of a newly described complication, interlenticular opacification. Three surgical means may help prevent this complication: meticulous cortical cleanup, especially in the equatorial region; creation of a relatively large continuous curvilinear capsulorhexis to sequester retained cells peripheral to the IOL optic within the equatorial fornix; insertion of the posterior IOL in the capsular bag and the anterior IOL in the ciliary sulcus to isolate retained cells from the interlenticular space.
PURPOSE: To evaluate the influence of intraocular lens (IOL) material and design on the outcome of postoperative lens epithelial cell proliferation within the capsular bag after cataract surgery. METHODS: A total of 5,079 human globes containing rigid and foldable posterior chamber IOL styles commonly implanted in the United States (n = 8) were analyzed in this study. Each globe, fixated in 10% formalin, was sectioned at the equator and analyzed using the Miyake-Apple posterior technique. The study consisted of 3 parts: First, to evaluate posterior capsule opacification (PCO); the Nd:YAG laser posterior capsulotomy rate (%) was documented and plotted on a monthly basis, creating a computerized trend line for each IOL style. Second, to evaluate anterior capsule opacification (ACO); 460 globes were processed for histologic examination. Anterior capsule fibrosis was scored from 0 to III, according to the thickness of proliferative tissue/cells on the inner surface of the anterior capsule at the capsulorhexis margin. Third, interlenticular opacification (ILO) was studied by analysis of 3 pairs of acrylic piggyback lenses that had been explanted because of opacification between their optics. Each IOL pair was processed for histologic examination, and scanning electron microscopy was performed on 1 of the lenses. RESULTS: In the first study, relatively higher Nd:YAG laser posterior capsulotomy rates (19.1% to 32.8%) were noted with the 4 oldest IOL designs in this study (2 foldable lenses, 1 3-piece polymethyl methacrylate [PMMA] design, and 1 single-piece all-PMMA design). Four modern lenses, 1 acrylic lens, and 3 silicone foldable IOL designs had Nd:YAG rates ranging from 1.3% to 14.6% (P < .0001). In the second study, mean ACO scores were highest with silicone-plate lenses (1.77 +/- 0.86 and 1.28 +/- 0.77). The lowest mean score was observed with the acrylic lens (0.51 +/- 0.52; P < .0001). In study 3, the analyses of the 3 pairs of explanted acrylic piggyback lenses showed that the opacification between them (ILO) may have different forms. CONCLUSIONS: Control of postoperative intracapsular cellular proliferation is important in avoiding 3 significant clinical complications. Postoperative lens epithelial cell proliferation is involved in the pathogenesis of PCO, ACO, and ILO, the latter being a newly described form of opacification within the capsular bag related to piggyback IOL implantation. IOL material and design are important factors influencing the outcome of these complications.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: Realizing that precise posterior chamber intraocular lens (PC-IOL) centration is needed to consistently achieve good optical results and visual rehabilitation after modern cataract surgery, the authors assessed the status and success rate of lens haptic fixation and its correlation with lens optic centration-decentration in a large series of eyes with PC-IOLs obtained postmortem. DESIGN: Prospective analysis of pseudophakic eyes obtained postmortem. PARTICIPANTS: A total of 3493 human eyes obtained postmortem, the largest database of such specimens available to date. METHODS: Miyake-Apple posterior photographic technique. MAIN OUTCOME MEASURES: The amount of decentration of rigid PC-IOLs and small-incision foldable PC-IOLs was analyzed, and the results were correlated with the type of fixation that had been achieved in each case. RESULTS: Determination of mean values revealed that capsular bag fixation was achieved in 52.05% of eyes, asymmetric bag-sulcus fixation in 34.21 % of eyes, and sulcus-sulcus fixation in 13.74% of eyes. Asymmetrically fixed lenses consistently showed significant decentration. During the past 5 years (1993-98), the overall rate of in-the-bag fixation increased to 59.2%; by 1998 it had increased to 64%. Most significantly, success in achieving bag-bag fixation of foldable IOLs implanted in association with modern capsular surgery with small incisions has surged to 90% over the past 4 years. CONCLUSIONS: The authors found a direct correlation of decentration in eyes with asymmetric fixation, and the results underscore the need for careful in-the-bag haptic placement. Although few surgeons today would dispute the goal to implanting haptics in the capsular bag, these findings show that the overall success rate over the years has, while improving, remained surprisingly low. The overall success rate of about 60% seen with all lens designs is probably as good as can be expected with classic large-incision extracapsular techniques. However, and most important and encouraging, the success rate of haptic fixation in cases with foldable lenses has improved dramatically during the past 4 years (up to the 90% range). This coincides with the present emphasis on modern capsular surgery and small-incision techniques used to insert these lenses.
PURPOSE: Posterior capsule opacification (PCO) is one of the most common complications of cataract surgery, and there is an urgent need to reduce its incidence. Its main treatment, neodymium:YAG (Nd:YAG) laser posterior capsulotomy, may be associated with significant morbidity and is expensive. In this study, the authors ascertain the effect of posterior chamber intraocular lens (PC-IOL) fixation and various IOL designs (rigid polymethyl methacrylate [PMMA] optic and small-incision foldable designs) on the pathogenesis of PCO. DESIGN: Prospective analysis of pseudophakic eyes obtained postmortem. PARTICIPANTS: A total of 3493 eyes with PC-IOLs obtained postmortem and received between 1984 and 1998. METHODS: Miyake-Apple posterior photographic technique. MAIN OUTCOME MEASURES: Peripheral Soemmering's ring, central PCO in the visual axis, and eyes that have had Nd:YAG laser posterior capsulotomy were analyzed and scored, and these findings were correlated with the type of fixation and IOL design. RESULTS: The degree of formation of peripheral Soemmering's ring was not influenced by IOL fixation. The acrylic design revealed relatively low Soemmering's ring scores. In contrast, central PCO and Nd:YAG laser capsulotomy scores were consistently influenced by fixation. The scores were significantly lower in eyes with in-the-bag fixation. The bag-bag fixated acrylic-PMMA design and the three modern silicone IOL designs analyzed in this study had less central PCO and lower posterior capsulotomy scores than did the PMMA IOLs. CONCLUSIONS: The formation of peripheral PCO (the Soemmering's ring), the precursor of clinically significant, vision-threatening PCO, is not significantly influenced by the haptic fixation pattern. It is much more dependent on the quality and thoroughness of surgical cortical cleanup. Reduction of Soemmering's ring is an important goal because the retained regenerative cortical cells within this lesion are the cells of origin of PCO. The acrylic IOL design was associated with a lessor amount of peripheral Soemmering's ring as compared with all other designs. In sharp contrast to peripheral PCO, fixation of the IOL was a highly significant factor affecting the formation and quantity of central PCO-the clinically significant opacity behind the IOL optic, measured in this series either by scoring an intact retro-optical membrane or by documenting the presence of a Nd:YAG laser posterior capsulotomy orifice. The quantity of central PCO was consistently much lower in eyes with in-the-bag fixated IOLs compared with lenses with one or both haptics out of the bag. This is best explained by the fact that secure in-the-bag fixation positions the IOL optic in the best possible position to create a barrier effect. The lowest PCO rates were generally noted with the acrylic and modern silicone IOL designs.
Explore the source record for details and available documents.
PURPOSE: To evaluate the visual results and postoperative complications of capsular bag and ciliary sulcus fixation of posterior chamber intraocular lenses (IOLs) for traumatic cataracts in children. SETTING: Department of Ophthalmology, Postgraduate Institute of Medical Education and Research, Chandigarh, India. METHODS: Twenty children (20 eyes) with traumatic cataracts had extracapsular cataract extraction (ECCE) and posterior chamber IOL implantation. They were randomly divided into 2 groups. Capsular bag fixation was performed in 10 children (Group A) and ciliary sulcus fixation in the other 10 (Group B). Traumatic cataracts associated with large corneal lacerations (10.0 mm or more), hyphema, angle recession, or posterior segment involvement were excluded. The best corrected visual acuity (BCVA) as well as early and delayed postoperative complications were prospectively evaluated in both groups. RESULTS: The BCVA was 6/12 or better in 9 eyes (90%) in Group A and 8 eyes (80%) in Group B at the end of the mean follow-up (24.6 months +/- 10.6 [SD]). Amblyopia (1 eye in Group A) and corneal scar and commotio retinae (1 eye each in Group B) accounted for a visual acuity of worse than 6/12. The residual refractive error did not exceed 3.50 diopters in either group. The incidences of fibrinous anterior uveitis and pupillary capture were significantly higher in Group B (P < .05, Fisher exact test). CONCLUSION: Capsular bag fixation of posterior chamber IOLs provided visual results similar to those with ciliary sulcus fixation but was associated with fewer postoperative complications, particularly uveitis and pupillary capture. This represents another important reason to attempt in-the-bag fixation in cases of traumatic cataract.
PURPOSE: To compare neodymium:YAG (Nd:YAG) laser effects on acrylic, silicone, and poly(methyl methacrylate) (PMMA) intraocular lens (IOL) polymers. METHODS: Ten Nd:YAG laser exposures were produced in each of 6 implantation-quality acrylic (Alcon MA60BM), silicone (Staar AQ1016), and PMMA (Alcon MC60BM) IOLs under identical conditions. Each polymer type was irradiated at 6 power settings (0.3, 0.5, 1.0, 1.5, 2.0, and 3.0 mJ) and at 2 focal points (midpoint of lens optic and on the posterior surface to which a cellophane membrane was affixed). The linear extent of the damage was measured using light microscopy. Specimens exposed to 1.0 mJ were processed for scanning electron microscopy. RESULTS: The damage threshold (> or = 5 microns depth) was 0.3 mJ for silicone and 1.0 mJ for acrylic and PMMA IOLs. At the clinically relevant power levels, 1.0 to 2.0 mJ, the depth of damage in the acrylic polymer was 11.9 to 30.5 times less than the depth in the silicone polymer. Similarly, the depth of damage in the PMMA polymer was 5.4 to 52.6 times less than the depth in the silicone polymer. The morphologic pattern of damage in the silicone IOL showed a deep, irregularly configured trough with meandering tendrils. Acrylic IOL damage morphology consisted of an ameboid-shaped entry site without radiating fractures and mild posterior penetration. Poly(methyl methacrylate) IOL damage consisted of a shallow focal trough with radiating fractures. CONCLUSIONS: The silicone IOL polymer had the lowest threshold for laser-induced damage and greater linear extension of damage than the PMMA and acrylic IOL polymers. Poly(methyl methacrylate) and silicone polymers exhibited collateral damage or ejected particulates adjacent to the entry site, whereas the acrylic polymer showed a discrete locus of damage.
PURPOSE: To compare the tear resistance of anterior capsulotomies using manual continuous curvilinear capsulorhexis (CCC) and vitrector-cut capsulotomy (vitrectorhexis) techniques in an animal model of the pediatric eye and in 2 pairs of human infant eyes. SETTING: Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Continuous curvilinear capsulorhexis and automated vitrectorhexis capsulotomy techniques were performed in 20 pig eyes, 10 with each technique. The capsules were then stretched until they ruptured. The forces required for rupture after each technique were compared. The forces required for rupture of the pig eye lens capsule were also compared with those required for the human infant eye lens capsule. Scanning electron microscopy was performed in each group following intraocular lens (IOL) insertion. RESULTS: All capsules stretched adequately for IOL insertion. The percentage of stretch prior to rupture was higher in the capsulorhexis group (mean 157%, range 147% to 169%) than in the vitrectorhexis group (mean 135%, range 124% to 147%) (P < .001). The percentage of stretch in the human infant eyes was not statistically different from that in the porcine eyes (P > .05). CONCLUSIONS: The manual CCC offered greater resistance to capsule tearing than the vitrectorhexis and also revealed a more smooth, regular edge. It therefore remains the gold standard. However, the vitrectorhexis displayed more than adequate resistance to unwanted anterior capsule tears when used for IOL insertion through capsulotomy sizes currently used in clinical practice.