Search PubMed⌕ Search

Biomedical subjects

D Hoppensteadt

Publications and source records attributed to D Hoppensteadt.

At least 91 records · Page 5Linked to original sources

Comparative antithrombotic and hemorrhagic effects of dermatan sulfate, heparan sulfate and heparin.

Dermatan sulfate and heparan sulfate are currently under development as potential antithrombotic drugs. In our studies we have evaluated the relative antithrombotic and bleeding effects of these two agents in comparison to heparin, the commonly used anticoagulant. In a rabbit model of stasis thrombosis, a 500 micrograms/kg IV dose of dermatan or heparan produced 50-60% inhibition of induced in vivo thrombosis. At 750 micrograms/kg, both agents produced greater than 75% inhibition of thrombosis. Ex vivo measurement of plasma samples obtained from these animals demonstrated variable clotting effects at the lower dose and a proportional increase in the clotting activity at the higher dose. No anti-Xa or anti-IIa activity was observed in any sample. In contrast, animals treated with only 100 micrograms/kg heparin showed complete inhibition of induced thrombosis with significant anti-Xa and anti-IIa activities as well as prolongation of the clotting assays (APTT, TT and HeptestR). In the hemorrhagic studies utilizing a rabbit ear blood loss model, a 5.0 mg/kg IV dose of dermatan or heparan produced much less blood loss than heparin. On a gravimetric basis, dermatan and heparan were 10 fold less hemorrhagic than heparin. These results indicate that the relative contribution of plasmatic and cellular sites to the mediation of the antithrombotic action of heparin, dermatan and heparan differ. Although the antithrombotic dosages of dermatan and heparan are higher than heparin, due to the different mechanisms of action of each agent, a better safety index may be provided by dermatan and heparan than heparin.

Animals↗

Oligosaccharide mapping of low molecular weight heparins: structure and activity differences.

Low molecular weight heparins from a variety of commercial sources were examined. These had been prepared by several methods including peroxidative cleavage, nitrous acid cleavage, chemical beta-elimination, enzymatic beta-elimination, and chromatographic fractionation. The molecular weight and polydispersity of these low molecular weight heparins showed greater differences than were observed for typical commercial heparin preparations. Considerable differences were also observed in the antithrombin III mediated anti factor Xa activity, the heparin cofactor II mediated antifactor IIa activity, and the USP activity of these low molecular weight heparins. An oligosaccharide-mapping technique (comparable to the peptide mapping of proteins) was applied to these low molecular weight heparins in an effort to understand the structural features responsible for their activity differences. Heparin lyase from Flavobacterium heparinum was first used to depolymerize the low molecular weight heparin into its constituent oligosaccharides. The oligosaccharides present in the resultant mixture were identified and quantitated by using standard oligosaccharides of defined structure on gradient polyacrylamide gel electrophoresis and strong anion exchange high pressure liquid chromatography. Six of the oligosaccharide products have been identified and represent nearly 90 wt % of heparin's mass. Even though all the low molecular weight heparins showed these six oligosaccharide components, their content in each varied greatly, accounting for 20 to over 90% of their mass. The antithrombin III mediated anti factor Xa activities of the low molecular weight heparins correlated only poorly to the concentration of a hexasaccharide containing a portion of heparin's antithrombin III binding site. The heparin cofactor II mediated antifactor IIa activity, however, could not be correlated to these six oligosaccharides of known structure nor to the molecular weight or charge density of these low molecular weight heparins. The low molecular weight heparins prepared by different methods each showed a new distinctive oligosaccharide in their maps. Their isolation and structural characterization, which included two-dimensional NMR and fast atom bombardment mass spectrometry, indicated that these unusual oligosaccharides result from end-sugar modification during chemical depolymerization. Both gel electrophoresis and high-pressure liquid chromatography mapping techniques showed a greater structural diversity between low molecular weight heparins than had previously been observed between similarly analyzed commercial heparins.

Factor Xa Inhibitors↗

Pharmacologic profile of a low molecular weight heparin (enoxaparin): experimental and clinical validation of the prophylactic antithrombotic effects.

Some 10 low molecular weight heparin products are currently available for commercial use. Enoxaparin and fraxiparin appear to be the most developed low molecular weight heparins. Many well-designed clinical trials have been carried out for different clinical indications with both of these products. As shown in both experimental and clinical settings, the prophylactic antithrombotic efficacy of enoxaparin is distinct from other low molecular weight heparins. Enoxaparin has provided consistently impressive clinical results. Moreover, at comparable dosages, other products have exhibited safety/efficacy profiles different from that of enoxaparin. The clinical performance of each low molecular weight heparin is characteristic of only that particular agent. Besides the commercially available low molecular weight heparin preparations, some 14 other agents are under development at this time. Although each product has similar basic characteristics, their biological actions should be studied carefully. Apart from differences in the physicochemical properties, the pharmacologic actions of these agents may differ significantly. Only results from valid clinical trials will show similarities or differences between the low molecular weight heparins. Other manufacturers should follow the lead of enoxaparin and conduct their own clinical trials on each of their products.

Animals↗

Biochemical and pharmacologic inequivalence of low molecular weight heparins.

LMW heparin fractions obtained from various sources must not be considered as bioequivalent in both the in vitro and in vivo responses. Because of compositional variations, these agents exhibit individual behavior and should be considered as distinct drugs whose safety and efficacy profile must be determined separately. Currently, there is no valid LMW heparin standard available, however, different LMW heparins can be profiled in identical test systems. It is erroneous to assume that most LMW heparins will behave in a similar fashion in terms of safety and efficacy. The need for defined tests to characterized these agents is evident and efforts to profile their actions should be made at both the basic and applied levels. Needless to say, the true efficacy of LMW heparins can only be validated in well-designed randomized clinical trials. Optimization of LMW heparins in preclinical pharmacologic studies, as reported here, is a crucial factor in the development of these agents. The superior clinical efficacy/safety performance of some of the LMW heparins in contrast to other LMW heparins is a result of extensive preclinical pharmacologic investigations undertaken to optimize the therapeutic index of these agents. Such optimization studies have not been conducted during the development of many LMW heparins, resulting in decreased efficacy and undue complications.

Animals↗

Comparative study on the in vitro and in vivo activities of seven low-molecular-weight heparins.

Different low-molecular-weight (LMW) heparins are produced by fractionation, enzymatic and chemical methods. Although the manufacturer's assigned molecular weights of these agents are similar (around 5,000 daltons), they exhibit considerable molecular structural heterogeneity due to the variations in the manufacturing process. In vitro standardization of these LMW heparins produces highly variable results due to the variability of assay specificity. In a comparative study with seven LMW heparins, differences were found in molecular weight distribution, antifactor Xa activity, antifactor IIa activity, Heptest activity, USP potency, platelet interactions, protamine and platelet factor 4 neutralization and charge density ratios. Relative antithrombotic actions varied between the seven agents and the ratio of the intravenous:subcutaneous effects were inconsistent with expected results based on in vitro properties or observed ex vivo effects. These products were not bioequivalent in equigravimetric or equipharmacopeial dosages (antifactor Xa, USP). Although the intravenous bioavailability was proportional to the potency for an individual agent, the subcutaneous bioavailability of the same agent showed differences from that of the intravenous regimen. In addition, significant differences between the bleeding profiles of these agents were noted in both intravenous and subcutaneous routes. The bleeding profiles did not correlate well with the relative proportion of the antifactor Xa component. However, some relationship to the bleeding effect was observed with the antifactor IIa and activated-partial-thromboplastin-time activities. These LMW heparins produced different effects on platelets as studied in the heparin-induced thrombocytopenia and platelet activation systems. These observations suggest that the individual composition of each LMW heparin determines its in vivo behavior which may account for the different safety/efficacy ratios observed in clinical trials.

Animals↗

Validity of the newly established low-molecular-weight heparin standard in cross-referencing low-molecular-weight heparins.

Four low-molecular-weight-heparin (LMWH) preparations have recently become available for clinical usage. Some ten preparations are currently under preclinical development. The safety/efficacy profile of each of these LMWHs is now known to be quite distinct from one and other. In order to minimize the variations in the pharmacologic responses and to cross-reference different products on a common scale, the WHO has recently introduced a LMWH standard. This standard is a nitrous-acid-depolymerized product provided by KabiVitrum (Stockholm, Sweden) with a specific physiochemical and biological profile. Although the in vitro characteristics of this standard are comparable to other LMWH, the in vivo behavior of this reference and the parent product, Fragmin, are quite different in comparison to other products. In a well-defined uniform biochemical and pharmacologic screening, seven LMWH were compared at WHO reference-adjusted potency using pharmacologically valid dose-response curves. Cross-referencing of various LMWHs against the WHO standard in terms of anti-Xa activity resulted in a marked elevation of the anti-IIa component of some of the LMWHs. Establishment of this WHO standard stipulated that the clinical performance of cross-referenced LMWHs would be equivalent to one another and variation in potency could be minimized. Our data suggest that utilizing the WHO, standard individual potency (anti-Xa)-adjusted LMWHs exhibit distinct safety/efficacy profiles which were not related in their observed in vitro potency. Each LMWH has distinct multiparametric molecular and biochemical characteristics which determine the pharmacologic activities of individual agents. Thus cross-referencing of LMWHs by one in vitro assay is of questionable value as it may result in serious dosimetric errors, resulting in serious thrombotic and bleeding complications.

Animals↗

Protein C antigen deficiency and warfarin necrosis.

Recent reports have suggested a correlation between congenital protein C deficiency and tissue necrosis complicating oral anticoagulants (warfarin necrosis). The authors studied blood samples of 13 patients, obtained two weeks to more than six months after warfarin necrosis. Protein C antigen levels were assayed by an enzyme-linked immunosorbent assay method (Diagnostica Stago, France). Factors II, VII, IX, and X were assayed by functional methods, and IX and X additionally by immunologic methods. The results show that 11 of 13 patients with a history of tissue necrosis had low protein C levels, ranging from 23 to 69%, with the normal range being 70-140%. These results confirm that low protein C antigen levels are implicated in the pathogenesis of warfarin necrosis.

Administration, Oral↗

In vitro evaluation of heparin fractions: old vs. new methods.

Conventionally, heparin has been evaluated for its anticoagulant effect by various nonspecific, poorly standardized coagulant methods such as the U.S. Pharmacopeial and other global (APTT) tests. However, these assays are relatively insensitive to heparin fractions and fragments, and give varying with the newer modes of heparin administration. It has become necessary, therefore, to develop other methods able to detect a proper therapeutic/prophylactic level and to evaluate a standard potency for these agents. Newer amidolytic assays utilizing synthetic substrates provide for specific anti-factor Xa or anti-factor IIa evaluation. Although these factors are believed to reflect the antithrombotic effect of heparin and its fractions/fragments, conclusive clinical studies are not available at this time. Interactions with non-AT-III-mediated pathways, the contact, kallikrein-kinin, and fibrinolytic system, other coagulant factors, endothelium, and eicosanoid system all can contribute to the overall antithrombotic response of heparin. Some of these actions are not measurable by current in vitro test methods. Amidolytic, immunochemical, and physical assays using various activators to generate endogenous factor Xa, as well as assays for the detection of metabolic or release products of each of these systems, may be more relevant to in vivo conditions. Specific low molecular weight markers such as fibrinopeptide A, which provide the earliest detection of hemostatic activation, can be measured directly, or an in vitro system can be developed to quantitate the relative generation of these markers. These methods can then be modified to assay the in vitro potency of heparin preparations. With proper consideration of reagent specificity and concentration, molecular interactions, reaction time and temperature, ionic type and concentration, reliable accurate methods for a true in vitro representation of in vivo events may be developed. Clinical assays must measure an endogenous response to therapy and not merely an absolute circulating level of drug. However, a standardized pure enzyme system may be ideal to evaluate the potency of these agents. The development of heparin derivatives necessitates a reassessment of currently practiced laboratory technology. Furthermore, well-defined biochemical methods are required for a standardized evaluation of potency and clinical monitoring of these agents.

Blood Coagulation↗

Comparative study of protease inhibitors on coagulation abnormalities in canine pancreatitis.

Coagulation abnormalities induced by pancreatitis were studied in 36 dogs. The 12 dogs in group I underwent a duodenotomy alone. The six dogs in groups II, III, IV, and V had pancreatitis induced by bile injection (1 cc/kg) into the pancreatic duct. Twenty minutes after bile-induced pancreatitis, group III was given 1.0 mg/kg aprotinin (trasylol), group IV was given 10 mg/kg S-2441, a new synthetic protease inhibitor, and group V was given 0.5 mg/kg alpha 2-antitrypsin by intravenous infusion over 10 min. Blood was drawn for amylase, protime (PT), partial thromboplastin time (PTT), fibrinogen, and platelets, in addition to markers of hypercoagulation, fibrinopeptide A, and antithrombin III, and markers of fibrinolysis, B beta 15-42 immunoreactive peptide (IP), and alpha 2-antiplasmin at baseline, 1/2, 1, 3, 6, 24, 48, and 72 hr after duodenotomy or bile injection. There was no significant difference in PT, platelets, antithrombin III, and fibrinopeptide A among the five groups. With the induction of pancreatitis (group II), serum amylase was significantly elevated but fibrinogen only became elevated at 24 hr and PTT at 48 hr. The increase in B beta 15-42 IP seen 30 min after induction of pancreatitis and the decrease in alpha 2-antiplasmin were blunted by aprotinin, alpha 1-antitrypsin, and S-2441, but inhibition of the rise in amylase and B beta 15-42 IP only reached significance with S-2441 (P less than 0.05). Pancreatitis-induced fibrinolysis was inhibited by S-2441 suggesting that synthetic protease inhibitors may play a therapeutic role in pancreatitis.

Acute Disease↗

Performance characteristics of a simple radioimmunoassay for fibrinopeptide A.

FPA, although identified 15 years ago, is now becoming an increasingly important diagnostic tool in the evaluation of the hemostatic process. Since this peptide is generated in very small amounts, only very sensitive methods, such as RIA, are useful for its quantitation. Measurement of this peptide allows for a most precise and reliable monitor of any ongoing thrombotic event in which thrombin is generated. Commercial kits have become available for fast and simple clinical evaluations of FPA. The Mallinckrodt RIA Quanti FPA kit has proved its reliability in precision, accuracy, fast turnaround time, and applicability to a routine laboratory setting. This assay kit was evaluated in our laboratory in various aspects. The following points summarize our finding: FPA is a useful diagnostic parameter to evaluate the activation of coagulation pathways in various pathologic states. A study of 170 normal plasma samples resulted in 1.7 +/- 0.5 ng/ml. No significant difference between males and females was noted. FPA levels are evaluated in patients with hypercoagulable states, DIC, and related thrombotic states. Our studies have shown that FPA levels are also elevated in certain cancers, postsurgical states, and certain other conditions in which the coagulation process is activated. During therapeutic heparinization, FPA levels are reduced; thus this form of therapy can be monitored using FPA levels. High-risk population (thrombotic) can be easily screened using FPA measurement. We propose that a multicenter study on FPA levels be conducted to prove its clinical relevance to other diseases.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Coagulation Tests↗

Molecular markers of contrast media-induced adverse reactions.

Currently used routine laboratory screening methods are not reliable in the prediction of contrast media-related adverse reactions. Cost-effective laboratory methods for various molecular markers of pathophysiologic activation have now become available. In vitro activation tests in high-risk patients may prove to be useful in the prediction of contrast-induced activation of various adverse reactions. If prior clinical evaluation of a patient suggests an ongoing pathologic process, profiling of the following molecular markers may prove to be useful and helpful in avoiding contrast-induced adverse reactions: Fibrinopeptide A, platelet factor 4, thromboxane B2, 5-HETE, physiologic inhibitors of proteases, B beta 15-42 related peptides, bradykinin/kininogen, and anaphylactozins. In patients suspected of reacting to contrast agents, a small dose of 1 to 5 ml can be injected as a bolus and molecular marker profiling on blood drawn after the infusion may prove to be useful screening tests. Additional clinical studies are needed to prove this. However, this screening test should be performed with extreme caution, since some of the patients are known to react to as little as 1 ml dose. The safety of newly developed nonionic contrast agents can be readily assessed by profiling various molecular markers of adverse reactions, which provide a more reliable and quantitative assessment of contrast-induced adverse reactions. Based on molecular marker profiling, various prophylactic agents can be given to high-risk patients to avoid contrast-induced adverse reactions.

Angiocardiography↗

Effects of protease inhibitors on coagulation abnormalities in acute canine pancreatitis.

Coagulation abnormalities associated with severe pancreatitis were studied in 24 dogs. Group I consists of six control subjects who had duodenotomy alone. Group II consists of six dogs with pancreatitis induced by bile injection ( lcm3 /kg) into the pancreatic duct. The six dogs in Group III and the six in Group IV were given aprotinin (trasylol) 1.0 mg/kg and S-2441 (10mg/kg), a new synthetic protease inhibitor, respectively. These were given over 10 minutes by intravenous infusion, 20 minutes after bile induced pancreatitis. Blood was drawn for amylase, prothrombin time (PT), partial thromboplastin time (PTT), fibrinogen, and platelets, in addition to markers for hypercoagulation, fibrinopeptide A, antithrombin III, and markers for fibrinolysis, B beta 15-42 immunoreactive peptides and alpha 2 antiplasmin at baseline, 30 minutes, 1 hour, 3 hours, 6 hours, and daily for 3 days after injection of bile or duodenotomy. There was no significant difference in PT, platelets, antithrombin III, and fibrinopeptide A among the four groups. Fibrinogen levels and PTT were minimally elevated in animals with bile induced pancreatitis, but these changes reached significance only at 24 hours and 48 hours, respectively (P less than 0.05). Immunoreactive B beta 15-42 became elevated at 30 minutes indicating fibrinolysis in animals with pancreatitis, and these changes were significant compared with Group I control subjects (P less than 0.05) throughout the study. Levels of alpha 2 antiplasmin were decreased in Group II animals with pancreatitis, which also suggests fibrinolysis. Amylase was elevated in Group II animals with pancreatitis (P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗