Performance of industrial mist collectors over time.

Effective, economical control of metalworking fluid mists at the source is important, because exposure to these mists may cause adverse health effects. This study investigated performance changes over time for industrial collectors that removed metalworking fluid mist in the laboratory and in a transmission plant. Aerosizers were used to measure the efficiency of each stage in several multistage collectors as a function of mist droplet diameter, for up to one year of continuous operation. Metal-mesh, first-stage filters operated at low pressure drops and were effective at removing droplets larger than 3 to 5 microns in diameter. Some second-stage filters worked better than others. Both "65 percent" and "95 percent" cartridge filters failed after only a few weeks; their efficiencies decreased substantially over that time. Pocket filters and cylindrical cartridges used as second-stage filters also decreased in efficiency for submicron droplets. Whereas filters for solid particles load continuously to form a dust cake that increases efficiency, mist filters form no cake and load only to the point where collection equals drainage. As a mist filter loads, the interstitial gas velocity increases, so that efficiency decreases for small droplets that collect by diffusion. Although a third-stage 95 percent DOP filter showed important decreases in efficiency over time for submicron droplets, third-stage HEPA filters operated with efficiencies that consistently approaches 100 percent for droplets of all sizes, even after one year of operation. These results suggest that the performance of second-stage filters can be improved if they can be made to drain collected liquid more effectively. For high efficiency, mist collectors should use a HEPA filter as a final stage.

Aerosols↗

Comparison of metalworking fluid mist exposures from machining with different levels of machine enclosure.

This research investigated the efficacy of machine enclosures in reducing employee exposures to metalworking fluid mist. Four hundred fifty-five personal samples from automotive machining and grinding operations collected over six years were divided into three groups based on the type and extent of enclosure and local exhaust ventilation. The sample groups were (1) machining equipment with original equipment manufacturer (OEM) total enclosures and local exhaust ventilation, (2) machining equipment with partial or retrofit enclosures and local exhaust ventilation, and (3) machining equipment with little or no enclosure. The results of the Mann Whitney U test of the three data sets indicated that the employees operating equipment with OEM enclosures had significantly lower exposures than employees operating equipment that had either of the other two control methods. There was no difference between the exposures of operators of equipment with retrofit enclosures compared to operators of equipment without enclosures. The median exposure for operators of equipment with OEM enclosures was 0.21 mg/m3, about half that found with the other two control methods. Each of the data sets was compared to exposure criteria; 100% of the exposures associated with OEM enclosures were below 1.0 mg/m3, and 90% of the exposures were below 0.5 mg/m3. The other two methods were not as effective as OEM in reducing exposure to below these criteria. These results indicate that OEM enclosures provide the most effective control of metalworking fluid mist exposure.

Aerosols↗

IHF study tour: a lesson in Swedish.

The International Health Federation paid its first visit to Sweden in June. The study tour, which involved 35 people from 15 countries, spent ten days studying Swedish health care with the particular brief--'Co-ordinating health services within a region". Here David Hands, assistant director, Kings Fund Centre, describes the tour which was organised by the Swedish Hospital Association and the Swedish Planning and Rationalisation Institute in conjunction with the National Board for Health and Welfare, and the Federation of Swedish County Councils.

Continuity of Patient Care↗

Live and let die?

Explore the source record for details and available documents.