Search PubMed⌕ Search

Biomedical subjects

D Hahn

Publications and source records attributed to D Hahn.

At least 19 recordsLinked to original sources

Optimization of ECG-triggered 3D (23)Na MRI of the human heart.

(23)Na MRI may allow distinction of normal and ischemically injured myocardium. The aim of this study was to optimize (23)Na MRI of the human heart by improvement of spatial resolution and ECG-triggering and to measure the signal/noise of blood and myocardium and the myocardium/blood signal ratios in a volunteer study. A spoiled gradient echo sequence was developed on a 1.5T scanner equipped with a (23)Na heart surface coil. 3D short axis ECG-triggered (23)Na MRI was performed in 10 healthy subjects. The signal/noise of myocardium and blood were 8.2 +/- 0.7 and 18.3 +/- 1.3, respectively, signal ratio myocardium/blood was 0.44 +/- 0.03. This value is in good agreement with the theoretical value of 0.45. ECG gated 3D (23)Na MRI of the human heart is feasible with sufficient spatial resolution and signal/noise ratio. Magn Reson Med 45:164-166, 2001.

Adult↗

Advances in human cardiac 31P-MR spectroscopy: SLOOP and clinical applications.

Phosphorus magnetic resonance spectroscopy (31P-MRS) has revealed a lot about the biochemistry of physiological and pathological processes in the heart. Nevertheless, until today, cardiac 31P-MRS has not had any clinical impact, albeit some pioneering studies demonstrated that 31P-MRS can indeed provide diagnostic information. In this paper, the development of techniques for human cardiac 31P-MRS over the past decade is reviewed, and the requirements for a reliable clinical measurement protocol are discussed. Spatial localization with optimal pointspread function (SLOOP) is a new method to achieve spatial localization and absolute quantitation. Its properties are detailed, and preliminary findings in patients with dilated cardiomyopathy or myocardial infarction are presented.

Heart Diseases↗

[Comparison of 3D power doppler ultrasound, color doppler ultrasound and digital subtraction angiography in carotid stenosis].

PURPOSE: To compare easy-to-perform three-dimensional power Doppler ultrasound (3D PDUS) to color Doppler ultrasound (CDUS) and digital subtraction angiography (DSA) in the assessment of internal carotid artery (ICA) stenoses in patients with severe atherosclerosis. METHODS: 26 ICA's (7 without stenosis, 4 low-, 4 middle-, and 11 high-grade stenoses) in 13 patients were examined with DSA, CDUS, and 3D PDUS. CDUS and 3D PDUS were performed with a 7.5 MHz standard transducer and a Sonoline Elegra ultrasound machine. The three methods were performed and interpreted by different persons who were not aware of the diagnoses. RESULTS: Regarding the degree of stenosis correlations between DSA and 3D PDUS were r = 0.98 (p < 0.001), between DSA and CDUS r = 0.97 (p < 0.001), and between CDUS and 3D PDUS r = 0.95 (p < 0.001). Sensitivity and specificity regarding the detection of a high-degree stenosis was 90% and 100% for 3D PDUS, and 100% and 93.3% for CDUS. CONCLUSION: Even in cases with severe atherosclerosis, both sonographic methods reveal similar results comparable to DSA. 3D PDUS does not result in a diagnostic improvement on CDUS, however, it does give the new opportunity for complete data storage, reconstruction, and survey presentations.

Aged↗

Human N-benzoyl-L-tyrosyl-p-aminobenzoic acid hydrolase (human meprin): genomic structure of the alpha and beta subunits.

N-Benzoyl-L-tyrosyl-p-aminobenzoic acid hydrolase (PPH, human meprin), a zinc-metalloendopeptidase of the astacin family, consists of two similar subunits. As well as in small-intestinal epithelial cells, the enzyme is found in lamina propria leucocytes, human cancer cells and colorectal cancer tissue, making it a potential candidate for a role in tumour formation and cancer progression. To elucidate the mechanisms that control PPH gene expression and to gain more insights into the evolutionary relationship of the two subunits, we analysed the complete exon-intron organization and searched for putative regulatory elements in 3 kb of the upstream region of both genes. The human gene for the alpha subunit is approx. 35 kb in size and contains 14 exons. The gene for the beta subunit is organized in 15 exons and spans approx. 27 kb. A comparison of both genes indicates strong structural similarities. The exons are almost identical in size, except exon 13 in PPHalpha, which codes for an additional I domain not present in PPHbeta. The locations of the respective exon-intron junctions and the intron phases are almost identical; five of them contain conserved split codons. The main variation is in the intron lengths. It can be concluded that PPHalpha and PPHbeta are derived from a common ancestor. Sequence analysis of the 5' flanking DNA with a computer search for promoter elements and different promoter constructs transfected into Caco-2 cells revealed a number of potential regulatory motifs and suggests that each of the two genes is regulated independently.

Amino Acid Sequence↗

Hybrid cardiac imaging with MR-CAT scan: a feasibility study.

We demonstrate the feasibility of a new versatile hybrid imaging concept, the combined acquisition technique (CAT), for cardiac imaging. The cardiac CAT approach, which combines new methodology with existing technology, essentially integrates fast low-angle shot (FLASH) and echoplanar imaging (EPI) modules in a sequential fashion, whereby each acquisition module is employed with independently optimized imaging parameters. One important CAT sequence optimization feature is the ability to use different bandwidths for different acquisition modules. Twelve healthy subjects were imaged using three cardiac CAT acquisition strategies: a) CAT was used to reduce breath-hold duration times while maintaining constant spatial resolution; b) CAT was used to increase spatial resolution in a given breath-hold time; and c) single-heart beat CAT imaging was performed. The results obtained demonstrate the feasibility of cardiac imaging using the CAT approach and the potential of this technique to accelerate the imaging process with almost conserved image quality.

Coronary Vessels↗

Changes in left and right ventricular cardiac function after valve replacement for aortic stenosis determined by cine MR imaging.

The purpose of this study was to determine the changes in function of both the left and the right ventricles (LV, RV) before and after aortic valve replacement (AVR), compared with age-matched healthy volunteers using magnetic resonance (MR) imaging. Fourteen patients with aortic stenosis underwent MR imaging (1.5 T) before and 3 (n = 14) and 12 (n = 9) months after surgical valve replacement. An electrocardiographically triggered two-dimensional cine fast low-angle shot sequence was used for the evaluation of absolute values and indices related to 1 m(2) body surface area for function, mass, and LV wall thickening. Fourteen age-matched healthy volunteers served as controls. Before surgery, all patients showed significant abnormalities of LV mass and function, whereas RV mass and function were not different from those of volunteers and remained mostly unchanged. After surgery, normalization of LV ejection fraction, absolute mass, and end-systolic wall thickness was observed, whereas the LV mass index failed to normalize, and LV volumes remained elevated. Aortic stenosis combined with a significant, but not severe reduction in LV function only affects the LV, whereas the RV remains unaffected at this stage of disease. AVR leads to improved LV function and reduced hypertrophy, but without normalization of LV volumes or the LV mass index within 1 year.

Aged↗

Deep venous thrombosis and consecutive pulmonary embolism as the first sign of an ovarian cancer: MR angiography using an intravascular contrast agent (CLARISCAN).

We describe a case of progressive deep venous thrombosis and chest pain studied by contrast-enhanced magnetic resonance (MR) angiography with the new intravascular contrast medium CLARISCAN (NC100150 Injection). Combined MR venography and angiography demonstrated pelvic vein thrombosis and consecutive pulmonary embolism caused by a large abdominal tumor, diagnosed as an ovarian cancer after surgery. The potential role of an intravascular contrast medium for studying the vascular system in multiple regions of the body within a single examination without the need for bolus timing is discussed. J. Magn. Reson. Imaging 2000;12:497-500.

Clinical Trials, Phase II as Topic↗

MR CAT scan: a modular approach for hybrid imaging.

In this study, a modular concept for NMR hybrid imaging is presented. This concept essentially integrates different imaging modules in a sequential fashion and is therefore called CAT (combined acquisition technique). CAT is not a single specific measurement sequence, but rather a sequence design concept whereby distinct acquisition techniques with varying imaging parameters are employed in rapid succession in order to cover k-space. The power of the CAT approach is that it provides a high flexibility toward the acquisition optimization with respect to the available imaging time and the desired image quality. Important CAT sequence optimization steps include the appropriate choice of the k-space coverage ratio and the application of mixed bandwidth technology. Details of both the CAT methodology and possible CAT acquisition strategies, such as FLASH/EPI-, RARE/EPI- and FLASH/BURST-CAT are provided. Examples from imaging experiments in phantoms and healthy volunteers including mixed bandwidth acquisitions are provided to demonstrate the feasibility of the proposed CAT concept.

Abdomen↗

[Evaluating signal intensity of movement-impaired myocardial segments in MR delayed images after administration of Gd-DTPA. Correlation of regional increase in contraction after revascularization].

PURPOSE: The aim of the study was to correlate delayed contrast enhancement of dysfunctional regions of the myocardium after injection of Gd-DTPA with the improvement of regional contractility 3 months after revascularization. MATERIAL AND METHODS: Eleven patients with coronary artery disease and wall motion abnormalities underwent MR imaging before and 3 months after revascularization therapy (PTCA or CABG). Short-axis images were acquired using a cine gradient echo sequence. After revascularization, a representative slice was analyzed 14 +/- 1 min after injection of 0.1 mmol/kg Gd-DTPA using a T1-weighted turbo fast low-angle shot sequence. Improved systolic wall thickening 3 months after revascularization served as criterion of viability and was correlated with delayed contrast enhancement patterns. RESULTS: After revascularization, 6 patients showed complete recovery of the dysfunctional area, 1 patient partial recovery, and 4 patients remained unchanged. All 4 patients with persisting wall motion abnormalities, 1/6 patients with recovery and the patient with partial recovery revealed a delayed enhancement. CONCLUSIONS: Three months after revascularization, delayed enhancement of dysfunctional myocardium is evident in patients without regional wall motion improvement, while the lack of delayed enhancement correlates with improvement of regional contractility.

Adult↗

[Cardiac energy metabolism in heart valve diseases with 31P MR spectroscopy].

PURPOSE: Heart valve disease combined with left ventricular hypertrophy leads to derangements in cardiac energy metabolism, which can be detected non-invasively by 31P-MR-spectroscopy. The purpose of the present study was to examine whether the derangements in cardiac metabolism are reversible after surgical valve replacement. PATIENTS AND METHODS: 10 healthy volunteers and 10 patients with aortic stenosis (pressure gradients > 60 mmHg) were included. For assessment of energy metabolism, 31P-MR spectra were obtained with a double oblique 3D-CSI technique (voxel size 25 cm3). In 5 of 10 patients, follow-up examination was performed 3 months after surgical valve replacement (SVR). Left ventricular (LV) function was analyzed by cine MRI. RESULTS: Before SVR the myocardial phosphocreatine to adenosinetriphosphate (PCr-ATP) ratio was significantly (p = 0.0002) reduced to 0.80 +/- 0.25 in patients compared to 1.65 +/- 0.21 in volunteers. 3 months after SVR, LV mass had significantly (p = 0.04) decreased from 238 +/- 33 g to 206 +/- 47 g. At the same time a significant (p = 0.04) increase of the PCr-ATP ratio from 0.80 +/- 0.25 to 1.28 +/- 0.22 was observed. A slight, but not significant, reduction of the phosphodiester ATP ratio was observed before SVR, with a trend towards normalization after SVR. CONCLUSIONS: After SVR, the deranged energy metabolism shows a trend towards normalization. Further follow-up is necessary to determine whether complete normalization of the energetic derangement can be observed over longer periods of time following SVR.

Adult↗

[MR tomography of the heart].

The introduction of magnetic resonance (MR) tomography has fundamentally changed radiological diagnosis for many diseases. Invasive digital subtraction angiography has already been widely replaced by noninvasive MR angiography for most of the vascular diseases. The rapid technical development of MR imaging in recent years has opened new functional imaging techniques. MR imaging of the heart allows simultaneous measurement of morphological and functional parameters in a single noninvasive examination without any radiation exposure. Because of the high spatial resolution and the reproducibility cine MR imaging is now the gold standard for functional analysis. With the improvement of myocardial perfusion and viability studies many diseases of the heart can be diagnosed in a single examination. MR spectroscopy is the only method which allows a view of the metabolism of the heart. New examinations for vascular imaging and flow quantification complete the goal of "one-stop-shop" imaging of the heart. MR imaging is the only diagnostic modality which allows a complete evaluation of many diseases of the heart with one technique, basic examination as well as follow-up studies. The very rapid improvement in MRI will overcome most of the limitations in the near future, especially concerning MR coronary angiography.

Cardiomyopathies↗

Hyperglycaemia-induced subcellular redistribution of GLUT1 glucose transporters in cultured human term placental trophoblast cells.

AIMS/HYPOTHESIS: We have recently shown that hyperglycaemia down-regulates the GLUT1 glucose transport system of term placental trophoblast. The reduction in GLUT1 protein alone was, however, not sufficient to explain the decrease in net glucose uptake, suggesting additional mechanisms. Therefore, we hypothesised that hyperglycaemia in vitro leads to a GLUT1 translocation from the trophoblast surface to intracellular sites. METHODS: This was tested in our study by determining the subcellular distribution of GLUT1 in human term placental trophoblast (n = 5 placentas) cultured for 48 h with 5 compared with 25 mmol/l D-glucose in vitro using immunogold labelling. RESULTS: Electron microscopic examination of cell profiles showed that 73% of total GLUT1 molecules reside in the trophoblast plasma membrane under basal conditions. The reduced GLUT1 expression (-20%; p < 0.05) after culture of the cells with 25 mmol/l glucose was accompanied by an internalisation of plasma membrane GLUT1, resulting in a loss of 40% (p < 0.05) in cell surface transporter labelling. Western blotting identified a characteristically broad band between 55-65 kDa, confirming the specificity of the GLUT1 antiserum. CONCLUSION/INTERPRETATION: We postulate that in addition to down-regulating human GLUT1 protein concentrations, glucose exerts its autoregulatory effect on hexose transport in term placental trophoblast by altering GLUT1 partitioning between the plasma membrane and intracellular sites in favour of the latter.

Cell Survival↗

Altered energy metabolism after myocardial infarction assessed by 31P-MR-spectroscopy in humans.

The value of 31P-magnetic resonance spectroscopy (MRS) as a possible tool to distinguish viable from non-viable tissue after myocardial infarction was analysed in humans. Fifteen patients 3 weeks after anterior myocardial infarction were studied with breath-hold cine MRI and 3D-CSI MRS (1.5 T system). 31P-spectra were obtained from infarcted as well as non-infarcted myocardium (voxel size 25 cm3 each). Gold standard for viability was recovery of regional function, as determined by a control MRI 6 months after revascularization. Ten age-matched healthy volunteers served as control group. No significant difference was found between the phosphocreatine to adenosinetriphosphate (PCr/ ATP) ratio of volunteers (SD 1.72+/-0.31) and non-infarcted septal myocardium of patients. Cine MRI demonstrated recovery of regional function in 10 patients, i. e. 10 patients showed viable and 5 non-viable myocardium. In viable myocardium, the PCr/ATP ratio was 1.47+/-0.38 (non-significant vs volunteers; p>0.05). In the 5 patients with akinetic myocardium, PCr peaks could not be detected. Therefore, calculation of PCr/ATP ratios was not possible. However, a significant reduction of the ATP signal-to-noise ratio (SNR) was observed (2.92+/-0.73 vs 6.68+/-0.80; patients vs volunteers; p<0.05). The SNR of ATP of akinetic regions may predict recovery of function after revascularization in patients with myocardial infarction.

Adenosine Triphosphate↗

Computed tomography after lymphangiography in the diagnosis of intestinal lymphangiectasia with protein-losing enteropathy in Noonan's syndrome.

Noonan's syndrome is a rare congenital disorder that may be associated with abnormalities in the lymphatic drainage. In this case of a 21-year-old man CT after bipedal lymphangiography confirmed the diagnosis of intestinal lymphangiectasy causing protein-losing enteropathy in Noonan's syndrome by showing contrast-enhanced abnormal lymphatic vessels in the mesentery and the intestinal wall. Because of the benefit of diet in case of intestinal involvement, we recommend a thorough documentation of the lymphatic drainage with lymphangiography followed by CT, if clinical signs of lymphatic dysplasia, such as pleural effusions, lymphedema, or hypoproteinemia are present.

Adult↗

Technical advances in ultrasound and MR imaging of carpal tunnel syndrome.

The aim of this study was to compare the latest ultrasound-array technology to a conventional "high-resolution" transducer, modified MRI technique, and nerve conduction studies (NCS), in the diagnosis of carpal tunnel syndrome (CTS). In 19 normal wrists and 15 wrists with CTS, US with two different transducers was performed: a conventional linear-array transducer (LA) and a newly developed Multi-D linear-array transducer (MDA) were used. The US images were evaluated determining the swelling and the flattening ratios of the median nerve and correlated to respective findings in MRI (1.5 T) and to NCS. The NCS confirmed CTS in all 15 wrists. Measures of median nerve compression (swelling and flattening ratios) were significantly different in patients with CTS and controls (p < 0.01) with both types of US transducers and MRI. The MDA yielded higher correlation to MRI than the LA. Using critical values of 1.3 for the swelling and 3.4 for the flattening ratio, MRI, and US with the MDA yielded a sensitivity of 100% each. Modern imaging modalities allow for an exact diagnosis of CTS even in cases with only slight median nerve pathology.

Adult↗

Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging.

We examined possible age- and gender-specific differences in the function and mass of left (LV) and right (RV) ventricles in 36 healthy volunteers using cine gradient-recalled echo magnetic resonance imaging. Subjects were divided into four groups (nine men and nine women in each): men aged under 45 years (32 +/- 7), women aged under 45 (27 +/- 6), men aged over 45 (59 +/- 8), and women aged over 45 (57 +/- 9). Functional analysis of cardiac volume and mass and of LV wall motion was performed by manual segmentation of the endocardial and epicardial borders of the end-diastolic and end-systolic frame; both absolute and normalized (per square meter body surface area) values were evaluated. With age there was a significant decrease in both absolute and normalized LV and RV chamber volumes (EDV, ESV), while LV and RV masses remained unchanged. Gender-specific differences were found in cardiac mass and volume (for men and women, respectively: LV mass, 155 +/- 18 and 110 +/- 16 g; LV EDV, 118 +/- 27 and 96 +/- 21 ml; LV ESV, 40 +/- 13 and 29 +/- 9 ml; RV mass, 52 +/- 10 and 39 +/- 5 g; RV EDV, 131 +/- 28 and 100 +/- 23 ml; RV ESV, 53 +/- 17 and 33 +/- 15 ml). Normalization to body surface area eliminated differences in LV volumes but not those in LV mass, RV mass, or RV function. Functional parameters such as cardiac output and LV ejection fraction showed nonsignificant or only slight differences and were thus largely independent of age and gender. Intra- and interobserver variability ranged between 1.4% and 5.9% for all parameters. Cine magnetic resonance imaging thus shows age- and gender-specific differences in cardiac function, and therefore the evaluation of cardiac function in patients should consider age- and gender-matched normative values.

Adult↗