Search PubMed⌕ Search

Biomedical subjects

D H Schmidt

Publications and source records attributed to D H Schmidt.

At least 37 records · Page 2Linked to original sources

Evaluation of transient mitral regurgitation in coronary artery disease.

The pathoanatomy and factors associated with transient mitral regurgitation (MR) induced by myocardial ischemic stress are unknown. Changes in valvular and ventricular parameters during transient, stress-induced MR in patients with coronary artery disease were investigated, and the clinical characteristics of these patients were identified. Color flow Doppler echocardiography was used to quantify the MR color area, the coaptation point of the mitral leaflets, the mitral valve anulus diameter, and left ventricular volumes and wall motion in 42 patients before and immediately after exercise echocardiography (group 1, n = 27), or before and during percutaneous transluminal coronary angioplasty (PTCA) (group 2, n = 15). Of the 27 patients with exercise echocardiography, 4 developed new, transient MR (group 1B) and 9 had MR both at rest and during exercise (group 1C). Of the 15 patients with PTCA, 7 developed new MR (group 2B). New MR (groups 1B and 2B) was associated with more severe stress-induced ventricular dyskinesia (p less than 0.05) than was seen in patients with chronic MR (group 1C) or in patients without MR, and occurred predominantly in patients with left anterior descending or right coronary artery stenoses. Stress-induced MR was not associated with changes in blood pressure or in mitral valve anulus diameter, nor with the development of mitral valve prolapse. It was associated with apical displacement of the mitral leaflets in patients in group 1B and C (p less than 0.05). New MR flow areas were significantly smaller than those in patients with chronic MR (p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗

Technically suboptimal first-pass radionuclide angiographic studies.

First-pass radionuclide angiography (FPRNA) has proven to correctly assess left ventricular function, however, technical difficulties do occur. One hundred and thirty one patients had contrast angiography and resting radionuclide angiography within 24 h. Of the 131 patients, 86 (66%) had adequate studies and 45 (34%) were technically suboptimal studies. In the latter group, low counts affected the quality of the images but did not change the left ventricular ejection fraction (LVEF) or regional wall motion (RWM) scores. Patients with high background activity showed overestimation of LVEF, however, by using a formula that was derived from the linear regression the LVEF could be calculated accurately in most cases. Multiple technical problems were noted in 14 patients in whom the best correlation was between contrast LVEF and background uncorrected LVEF from FPRNA (r = 0.87). In the latter group, FPRNA showed overestimation of RWM in 8 patients (57%), mainly in the inferior wall. We conclude that for most technically compromised first-pass radionuclide angiographic data, accurate LVEF values can be achieved but errors in regional wall motion interpretation will occur, especially when multiple technical problems exist.

Female↗

Mitral regurgitation: parameters that affect the correlation between Doppler echocardiography and contrast ventriculography.

The correlation between Doppler and contrast angiographic estimation of severity of mitral regurgitation was assessed retrospectively in 60 patients with native mitral valve disease. Results showed r = 0.82. Among 15 parameters (demographic, clinical, echocardiographic and hemodynamic) 3 were found to be associated with overestimation of the severity by Doppler: low left ventricular ejection fraction, low cardiac output, and high mean pulmonary artery capillary wedge pressure. On the other hand, a large left atrium was associated with underestimation of mitral regurgitation by Doppler. Based on that data, Doppler results were adjusted in a prospective group of 30 patients with native mitral valve disease. The correlation between contrast ventriculography and uncorrected Doppler results showed r = 0.83, while the corrected Doppler results showed r = 0.91. The study implies that although a good correlation is found between the two modalities for estimation of mitral regurgitation, a better correlation can be achieved by adjusting the Doppler results according to the above-mentioned parameters.

Contrast Media↗

Regional myocardial blood flow with a reperfusion catheter and an autoperfusion balloon catheter during total coronary occlusion.

We investigated the ability of two new coronary perfusion catheters to maintain regional myocardial blood flow throughout a 90-minute period of occlusion. In 21 dogs (group I = total occlusion control; group II = reperfusion catheter; group III = autoperfusion balloon catheter) we studied regional blood flow, distal coronary perfusion pressure, infarct size, and red blood cell hemolysis after placement of either catheter into the left anterior descending coronary artery. Regional (microsphere) blood flow showed a reduction in transmural blood flow during occlusion in comparison to baseline values (1.07 +/- 0.12 to 0.81 +/- 0.11 and 1.01 +/- 0.16 to 0.73 +/- 0.08 ml/min subendocardial perfusion for groups II and III, respectively). Comparable changes in blood flow were observed in the subepicardial and midmyocardial regions. Distal coronary perfusion pressures were reduced by 26% and 28% for groups II and III, respectively. Both catheters prevented significant infarction and maintained adequate regional myocardial blood flow throughout the 90-minute period of occlusion without significant complications of clotting or destruction of erythrocytes.

Angioplasty, Balloon, Coronary↗

Left ventricular volume calculation using a count-based ratio method applied to multigated radionuclide angiography.

The purpose of this study was to investigate the accuracy of a new count-proportional method for the measurement of left ventricular volume when applied to gated equilibrium blood-pool imaging. An equation is developed that relates total chamber volume, Vt, to the area of a pixel (M) and the ratio (R) of total counts within the chamber to the counts within the hottest pixel in the chamber such that Vt = 1.38 M3R3/2. The value of M is a constant for the particular scintillation camera-collimator system and R is obtained from observed count rates. All calculated volumes were compared to volumes measured using biplane contrast ventriculography. In 25 patients, the method for ventricular volumes gave an r of 0.95 and an s.e.e. of 23 ml [Volume (nuclear) = 0.94 Volume (cath) + 1.3]. Endsystolic volume was best calculated from end-diastolic volume and ejection fraction. Manual regions of interest were more accurate than automated regions of interest. This method appears to be as accurate as more complex approaches and has the advantage of not requiring attenuation correction or blood sampling.

Angiography↗

Inadequate subendocardial oxygen delivery during perfluorocarbon perfusion in a canine model of ischemia.

Perfusion of the coronary artery distal to an occlusion was performed in 16 canine preparations to compare the mechanical perfusion of autologous blood to the perfluorocarbon fluosol DA, 20% emulsion (FDA-20). Both substances were perfused under similar conditions (30, 60, and 80 ml/min) and regional electrograms, contractility, and coronary perfusion were measured relative to native coronary perfusion. Autologous blood (60 and 80 ml/min) produced a significant increase in regional (epicardial, midmyocardial, and endocardial) and transmural flow, but not in the endocardial/epicardial perfusion ratio. No other significant changes were observed during autologous blood perfusion. In contrast, FDA-20 perfusion resulted in significant ST depression (-1.8 +/- 0.2, -1.7 +/- 0.2, and -1.3 +/- 0.3 mm) at 30, 60, and 80 ml/min, respectively. FDA-20 also induced a significant decrease in distal diastolic coronary pressure and resistance, a significant decrease in the endocardial/epicardial perfusion ratio at all three perfusion rates, and a significant reduction in delivery of O2 to the subendocardium. These results indicate that autologous blood perfusion of the distal coronary artery during occlusion preserves myocardial function to a better degree than does FDA-20.

Animals↗

Effect of age and training on aerobic capacity and body composition of master athletes.

Maximum oxygen uptake (VO2max) and body composition have been shown to deteriorate with age. How much of the decline is attributable to aging and how much is affected by reduced physical activity is not known. The purpose of this investigation was to determine the aerobic capacity and body composition of 24 master track athletes and to evaluate the relationship to age and maintenance of training over a 10-yr period. The subjects (50-82 yr of age) were retested after a 10.1-yr follow-up (T2). All continued their aerobic training, but only 11 were still highly competitive (COMP) and continued to train at the same intensity. The other 13 athletes studied became noncompetitive (post-COMP) and reduced their training intensity. The results showed the COMP group to maintain its VO2max and maximum O2 pulse while the post-COMP group showed a significant decline (54.2-53.3 vs. 52.5-45.9 ml X kg-1 X min-1; 20.7-20.8 vs. 22.4-20.0 ml/beat from test one (T1) to T2 for the COMP vs. post-COMP groups, respectively). Maximum heart rate declined 7 beats/min for both groups. Body composition showed no difference between groups from T1 to T2. For both groups body weight declined slightly (70.0-68.9 kg), percent fat increased significantly (13.1-15.1%), and fat-free weight decreased significantly (61.0-59.0 kg). Thus, when training was maintained, aerobic capacity remained unchanged over the follow-up period. Body composition changed for both groups and may have been related to aging and/or the type of training performed.

Aged↗

Functional translation of exercise responses from graded exercise testing to exercise training.

This study attempts to develop a quantitative approach to the prescription of absolute exercise intensity during level ground ambulation (min/mile) or cycle ergometry (kpm) from responses observed during GXT. A total of 345 subjects performed GXT and exercise training sessions with either the Bruce treadmill protocol and level ground ambulation (N = 154) or cycle ergometry (N = 191). Responses from 90% of each group were used to generate equations for predicting training pace (or power output) from the time (or power output) during the GXT when target HR was achieved. FAI was also included in the prediction of training pace (or power output). The remaining 10% of subjects in each group were used to cross-validate the prediction equations. The correlation between the time (or power output) during GXT when the training HR was observed and the pace of ambulation (or power output) was 0.70 for treadmill walking and 0.88 for cycle-cycle. Correlations were increased by the addition of FAI to the prediction equation. The results of this investigation suggest that the absolute intensity of exercise for training can be predicted accurately from GXT results.

Cardiac Rehabilitation↗

High count rate first-pass radionuclide angiography using a digital gamma camera.

In this study, first-pass radionuclide angiography (FPRNA) was performed using a digital single-crystal gamma camera. Twenty-nine men and six women (ages 43-80, mean 61 yr) underwent FPRNA in the supine position immediately prior to cardiac catheterization. Total counts/sec in the whole field-of-view in the right ventricular phase were 150,352 +/- 26,006. Background uncorrected counts in the representative cycle were 7,651 +/- 2,527 at end-diastolie and 4,904 +/- 2,314 at end-systolie. A linear correlation between FPRNA left ventricular (LV) ejection fraction and contrast LV ejection fraction gave an r = 0.95 with an s.e.e. of 0.05. Analyses of intra- and interobserver variability gave r = 0.99 and 0.98 and an s.e.e. of 0.02 and 0.03, respectively. Spearman-Rank correlation coefficients between FPRNA and contrast angiographic wall-motion scores were greater than 0.8 for all walls, while sensitivity/specificity were 0.86/0.90, 0.76/1.00, 0.76/1.00 for anterior, apical, and inferior wall-motion abnormalities, respectively. We conclude that satisfactory counting statistics for FPRNA can be obtained with a digital gamma camera, and that accurate and reproducible measurements of global and regional left ventricular function can be obtained with this technique.

Adult↗

Background correction in first-pass radionuclide angiography: comparison of several approaches.

This study was designed to test the comparative accuracy of several commonly used background correction techniques in first-pass radionuclide angiography (FPRNA). Thirty patients underwent FPRNA and single plane contrast angiography (CA) within 1 hr of each other. The left ventricular ejection fractions (LVEF) calculated from the different background subtraction approaches to FPRNA were compared to the CA LVEF. When applied to a representative cycle, a horseshoe-shaped background region of interest (BKROI) underestimated LVEF (p less than 0.005, r = 0.91, s.e.e. = 0.06) while a ring shaped BKROI adjusted at end-systole for aortic valve motion insignificantly overestimated LVEF (p = NS, r = 0.91, s.e.e. = 0.07). A lung background approach applied to a representative cycle gave the best correlation with CA (p = NS, r = 0.96, s.e.e. = 0.04). Without using a representative cycle, time-activity curves from a horseshoe-shaped BKROI and the LV ROI were created and the LV curve was normalized to the peak counts in the BKROI curve. LVEF calculated from the normalized curve correlated favorably with CA LVEF (p = NS, r = 0.91, s.e.e. = 0.08). The influence of some recently described improvements in representative cycle generation are also documented.

Aged↗

Assessment of single vessel coronary artery disease: results of exercise electrocardiography, thallium-201 myocardial perfusion imaging and radionuclide angiography.

The sensitivity of the commonly used stress tests for the diagnosis of coronary artery disease was analyzed in 46 patients with significant occlusion (greater than or equal to 70% luminal diameter obstruction) of only one major coronary artery and no prior myocardial infarction. In all patients, thallium-201 perfusion imaging (both planar and seven-pinhole tomographic) and 12 lead electrocardiography were performed during the same graded treadmill exercise test and radionuclide angiography was performed during upright bicycle exercise. Exercise rate-pressure (double) product was 22,307 +/- 6,750 on the treadmill compared with 22,995 +/- 5,622 on the bicycle (p = NS). Exercise electrocardiograms were unequivocally abnormal in 24 patients (52%). Qualitative planar thallium images were abnormal in 42 patients (91%). Quantitative analysis of the tomographic thallium images were abnormal in 41 patients (89%). An exercise ejection fraction of less than 0.56 or a new wall motion abnormality was seen in 30 patients (65%). Results were similar for the right (n = 11) and left anterior descending (n = 28) coronary arteries while all tests but the planar thallium imaging showed a lower sensitivity for isolated circumflex artery disease (n = 7). The specificity of the tests was 72, 83, 89 and 72% for electrocardiography, planar thallium imaging, tomographic thallium imaging and radionuclide angiography, respectively. The results suggest that exercise thallium-201 perfusion imaging is the most sensitive noninvasive stress test for the diagnosis of single vessel coronary artery disease.

Adult↗

Myocardial perfusion after aortocoronary bypass surgery: measurements at rest and after administration of isoproterenol.

This study examined quantitative regional myocardial perfusion (RMP) measured by the washout of 133Xe at rest and after an isoproterenol challenge in 50 patients (group I) studied 8 to 14 days after they underwent saphenous vein bypass grafting to the left coronary artery, and compared this with RMP measured in the native left coronary artery in 14 patients (group II) with significant coronary artery disease and in 12 normal subjects (group III). The double product of the heart rate and aortic systolic pressure was used as an indicator of demand. The statistical significance of group comparisons was analyzed with Dunn's multiple comparisons among means test. Analysis of the data showed no significant difference among the groups with respect to aortic systolic pressure. In subjects at rest, heart rate was lower in groups II and III than in group I, and double product was lower in group II than in group I. After isoproterenol, both heart rate and double product were lower in group II compared with groups I and III, but there was no significant difference between groups I and III with respect to heart rate or double product. Mean resting RMP in group II was lower than in group I; however, results of other group comparisons were insignificant for resting parameters. After isoproterenol, mean flow (ml/100 g/min) in group I was similar to flow in group III (130 +/- 24 vs 139 +/- 26). In contrast, the average flow response after isoproterenol was significantly less in group II when compared with that in group I (105 +/- 20 vs 130 +/- 24) and with that in group III (105 +/- 20 vs 139 +/- 26). Because of differences in levels of demand with isoproterenol, the change in flow was normalized to the percent increase in double product. These data showed results similar to those above, i.e., normalized RMP in patients with coronary artery disease was significantly lower than that in normal subjects (82 +/- 41 vs 119 +/- 57) and in revascularized patients (82 +/- 41 vs 105 +/- 54). However, there was no significant difference between normal subjects and patients who had undergone surgery. To further evaluate the relationship of flow response to demand parameters, we plotted RMP/double product vs resistance. The data revealed a significant correlation between these variables in all groups both in subjects at rest and after isoproterenol.(ABSTRACT TRUNCATED AT 400 WORDS)

Coronary Artery Bypass↗

Sequential internal mammary artery grafts. Expanded utilization of an ideal conduit.

The internal mammary artery, when used as a conduit for coronary artery bypass, offers a better long-term patency rate and survival rate than the saphenous vein; however, its utility has been limited. Among other factors, the availability of only two internal mammary arteries for anastomosis has been a major limitation. In an attempt to overcome this limitation, we constructed sequential internal mammary artery grafts in 87 patients. In 49 patients (Group I), only one internal mammary artery was used for sequential anastomosis. In another 31 patients (Group II), one internal mammary artery was used for sequential anastomosis and the other was used for single end-to-side anastomosis. Both internal mammary arteries were used in seven patients (Group III) for the construction of sequential anastomoses. Postoperatively, 64 patients were evaluated by exercise stress tests. None of these patients had a positive stress test although seven patients (11%) had electrocardiographic changes that were considered equivocal. Coronary angiography was performed in 35 of the 87 patients, with 92 vein grafts and 90 internal mammary artery anastomotic sites evaluated within 1 year of operation. A total of 83 vein grafts and 84 internal mammary artery anastomotic sites evaluated within 1 year of operation. A total of 83 vein grafts and 84 internal mammary artery anastomoses were found to be patent. Thus the patency rate for vein grafts was 90% and for internal mammary artery grafts, 93%. During the follow-up period (8 to 52 months), three patients died and one was lost to follow-up. Among the remaining patients, 79 had complete relief from symptoms, three had minimal symptoms, and one patient obtained no relief from symptoms. Based on these results, we have concluded that the extended use of internal mammary artery, constructing sequential anastomoses, is technically feasible and provides adequate perfusion to the area of myocardium supplied by such grafts.

Adult↗

Peak exercise and immediate postexercise imaging for the detection of left ventricular functional abnormalities in coronary artery disease.

Eleven patients without significant coronary artery disease (CAD) (group A), 22 patients with significant CAD and no prior myocardial infarction (MI) (group B), and 10 patients with CAD and a previous MI (group C) were imaged at rest, at peak exercise and immediately after exercise by first-pass radionuclide angiography. At peak exercise, mean left ventricular (LV) ejection fraction (EF) did not change significantly in group A or C and decreased significantly in group B. However, in all groups mean LVEF increased significantly immediately after exercise. Examination of potential criteria for an abnormal LVEF response showed that changes from rest to peak exercise were sensitive for detection of CAD but were not specific. Postexercise criteria were more specific but relatively insensitive: 15 of 32 patients (47%) with CAD showed a normal (greater than 5% increase over rest) response after exercise. Similarly, a regional abnormality at peak exercise was 100% sensitive, compared with a sensitivity of 78% after exercise for the whole group, and only 68% in patients without prior MI. Seven patients would have been misclassified as normal if postexercise imaging alone had been performed. The likelihood of an abnormal postexercise EF response was related to the extent of CAD: No patient with 1-vessel, 8 of 17 with 2-vessel and 9 of 12 with 3-vessel CAD showed such a response. Peak exercise imaging is necessary to achieve maximal sensitivity for the detection of CAD, and a high false-negative rate will be obtained if postexercise imaging only is used. The combination of peak exercise and postexercise imaging may be of value in assessing the severity of CAD.

Adult↗

Effects of intraaortic balloon counterpulsation on myocardial blood flow in patients with severe coronary artery disease.

The purpose of this study was to test the hypothesis that myocardial blood flow distal to a critical stenosis would increase during intraaortic balloon counterpulsation. Accordingly, 13 patients with severe coronary artery disease were studied at the time of elective preoperative insertion of an intraaortic balloon catheter. Hemodynamic measurements and measurements of myocardial blood flow were made before and during counterpulsation. Myocardial blood flow was measured with a xenon-133 washout technique. Compared with control measurements, the heart rate decreased from 87.8 +/- 18.8 to 82.8 +/- 13.4 beats/min (p = 0.02) and systolic arterial pressure decreased from 112.1 +/- 17.9 to 97.8 +/- 14.8 mm Hg (p = 0.004) during counterpulsation. Diastolic arterial pressure increased from 72.2 +/- 10.1 to 120.2 +/- 21.4 mm Hg (p = 0.00002) during counterpulsation. Myocardial blood flow for the entire group decreased from 48.8 +/- 14.1 to 42.6 +/- 11.0 ml/100 g per min (p = 0.008). Regional flows in the left anterior descending and circumflex distributions also decreased. Left anterior descending artery blood flow decreased insignificantly from 51.5 +/- 14.4 to 47.4 +/- 11.7 ml/100 g per min (p = not significant), while circumflex flow decreased from 50.7 +/- 12.2 to 41.1 +/- 8.9 ml/100 g per min (p = 0.008). When normalized for the rate-pressure product, myocardial blood flow was 53 +/- 16 X 10(-4) at rest and 55 +/- 12 X 10(-4) (p = not significant) during counterpulsation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

First-pass radionuclide angiography via pulmonary arterial catheters. A critical analysis of background components.

Residual background activity following first-pass radionuclide angiography was assessed in 44 patients after eliminating activity in the right heart, left lung, and most of the right lung. The ejection fraction (EF) was calculated in two ways: (a) assuming background activity was present only in the right heart and lungs, and (b) correcting for scattered radiation by placing a circular region of interest around the left ventricle. With the first method, contrast EF was significantly underestimated in both AP and RAO views. With the second method, correlation was close in both views and absolute values agreed well with contrast EF. These results indicate that there is a substantial and measurable background component, due mainly to Compton scatter, even when activity from the right heart and lungs is eliminated.

Adult↗