Antiarrhythmic anesthetic action. II. The effect of methoxyflurane on ventricular automaticity.

During the course of surgical anesthesia, the majority of patients experience some arrhythmias, virtually all of which can be attributed to changes in cardiac pacemaker automaticity and/or alterations in cardiac conduction velocity. Therefore, a better understanding of these mechansims is of importance to anesthesiologists. Cardiac automaticity in the intact heart of dogs under methoxyflurane anesthesia was assessed by measuring changes in ventricular escape time (VET) and ventricular escape rate (VER). A slight shortening of VET was noted, while there was virtually no change from control in VER. Unexpectedly, however, a nonsinus supraventricular escape focus became prominent in many animals at a low anesthetic dose and in all animals at a higher anesthetic concentration. This effect was shown to be preventable by pretreatment with reserpine or a beta-blocking agent. It is concluded that methoxyflurane increases the automaticity of parts of the atrial conducting system, other than the sinus, either by a direct effect or by increasing the sensitivity to prevailing background adrenergic levels.

Anesthesia, Inhalation↗

Laboratory evaluation of pressure transducer domes containing a diaphragm.

Pressure transducers are being used with increasing frequency in patient care. The recent availability of sterile transducer domes containing a diaphragm provides a means for reducing the risk of bacteremia when using these devices. The present studies measured the effect of diaphragm domes on the accuracy of pressure measurement. The sensitivity and frequency responses of 5 pressure transducers utilizing diaphragm and nondiaphragm domes were compared. The results indicate that the type of dome utilized and the method of dome application can significantly modify pressure transducer performance. The data are useful in providing optimal accuracy and reliability of pressure measurments when using a diaphragm dome, pressure transducer combination.

Blood Pressure Determination↗

A reevaluation of the association between instrument delivery and epidural analgesia.

BACKGROUND AND OBJECTIVES: Over 100 papers in the medical literature suggest pro or con that epidural analgesia is associated with an increase in the incidence of instrument delivery. This two-component study was performed to evaluate the influence of epidural labor analgesia on the incidence of instrument delivery. METHODS: Component 1 was a retrospective analysis of the medical records of 14,804 mothers having a vaginal delivery before and after implementation of an active epidural service. Component 2 was a case control study designed to determine factors, in addition to epidural analgesia, associated with an increase in instrument delivery. In component 2 11 factors describing maternal, fetal, anesthetic, and obstetric factors were analyzed for each of 609 consecutive patients having an instrument delivery and 246 controls having a spontaneous vaginal delivery. RESULTS: In component 1, despite a tenfold increase in the use of epidural analgesia, there was a similar association between epidural use and instrument delivery in both time periods. Additionally, the epidural-forceps association was twice as strong for parous patients as for nulliparous patients (odds-ratios 9.74 and 4.52, respectively). In component 2, five factors were significantly (P > .0001) associated with instrument delivery conclusions. CONCLUSIONS: While epidural analgesia was one factor, the others were gestational age > 41 weeks, a second stage of labor > 2 hours, an occiput posterior or transverse fetal position, and previous cesarean section. These four factors are individually and independently associated with an increase in the incidence of instrument delivery independent of epidural use.

Adolescent↗