Search PubMed⌕ Search

Biomedical subjects

D Guimaraens

Publications and source records attributed to D Guimaraens.

At least 19 recordsLinked to original sources

Occupational allergic contact dermatitis from cyanoacrylate.

Cyanoacrylates are widely used in adhesive techniques. Cyanoacrylate adhesives differ physically for the different needs of application, and chemically in function of the size of ester molecules. A 40-year-old man employed at the National Mint and Stamp factory presented with hyperkeratotic lesions on the fingers of the right hand. His job consisted of fixing microchips to plastic phone cards with Loctite Series 414. Patch testing confirmed sensitivity to cyanoacrylates. After the diagnosis of allergic contact dermatitis was established, the patient, to be cured of the dermatitis, changed his workplace 2 months later.

Adhesives↗

Fixed exanthema induced by ultraviolet radiation.

An unusual cutaneous eruption of the feet and lower limbs induced by ultraviolet radiation in a 30-year-old caucasian man is presented. Previous reports in the literature and the present case indicate that sunlight and UV radiation may provoke fixed eruptions themselves without drug exposure.

Adult↗

Occupational allergic contact dermatitis in construction workers.

We report the patch test results of 449 construction workers who came as patients to the Occupational Dermatology Service of the Instituto Nacional de Medicina y Seguridad del Trabajo in Madrid between 1989 and 1993. 90.8% of them were patch tested, because they had cutaneous lesions or a clinical history suggestive of occupational dermatitis. 65.5% (268) of those patch tested showed one or more reactions connected with their work. Chromate at 42.1% was the main allergen, followed by cobalt, 20.5%, nickel, 10%, and epoxy resin, 7.5%. 25.9% (106) of patients showed sensitization to rubber components, the majority at 23.7% to thiuram mix, with TETD being the main allergen.

Adolescent↗

Sensitization to epoxy resin systems in special flooring workers.

The use of new products in building and public works is increasing, among them being special floor coverings containing epoxy resins and derivatives. These are used principally in heavily frequented areas, such as shopping precincts, hospitals, civic centres, etc., due to their high resistance to wear and tear, environmental factors, etc. In the last 2 years, we have studied 15 cases of men sensitized to epoxy resin, or derivatives, who worked with special floorings. Speed of sensitization, severity of lesions, and localization to the hands, face and legs were characteristic.

Adult↗

Type IV allergy to rubber additives: a 10-year study of 686 cases.

BACKGROUND: Rubber additives, mainly vulcanizers and antioxidants, are increasingly a cause of contact dermatitis. OBJECTIVE: The aim of the present study was to determine the frequency of type IV allergy to rubber additives. METHODS: Seven thousand patients seen during a 10-year period were evaluated. Of them, 4680 were patch tested with the standard series recommended by the Spanish Group for Research of Contact Dermatitis (GEIDC) and a series of individual rubber additives. RESULTS: A total of 686 patients (14.7% of those patch tested) had one or more positive reactions to rubber additives. Of these, 582 (84.8%) were men and 104 (15.2%) were women. The incidence of rubber sensitization was especially high among construction workers (47.0%). CONCLUSION: Rubber additives are a common cause of occupational contact dermatitis, particularly in construction workers. We postulate that rubber gloves and boots (utilized to avoid contact with sensitizing substances) themselves may be a common cause of contact dermatitis. The high incidence of allergy to some rubber additives, such as thiurams and carbas, indicates that their replacement by other less sensitizing vulcanizers is advisable.

Adolescent↗

Patch test sensitivity to the preservative Kathon CG in Spain.

Kathon CG is a very well studied preservative used in cosmetics and toiletries. It is effective in low concentrations (3 to 15 ppm active ingredients) and exhibits outstanding antimicrobial activity against gram-negative and gram-positive bacteria, yeasts and fungi. Although this biocide is not considered to pose a toxicological hazard at recommended use levels, the sensitizing potential of Kathon CG has been established. From November 1988 to June 1989, we patch tested 626 unselected contact dermatitis patients with Kathon CG solution containing 200 ppm active ingredients and obtained 22 (3.5%) positive reactions. Relevance was established in 7 of the 22 patients. Women were predominantly sensitized, the principal source of sensitization being cosmetics.

Adolescent↗