An in vitro biomechanical comparison of two interlocking-nail systems for fixation of ostectomized equine third metacarpal bones.

OBJECTIVE: To compare the mechanical properties of 2 interlocking-nail systems for fixation of ostectomized equine third metacarpi (MC3): (1) a standard interlocking nail with 2 parallel screws proximal and distal to a 1-cm ostectomy; and (2) a modified interlocking nail with 2 screws proximal and distal to a 1-cm ostectomy with the screws offset by 30 degrees. ANIMAL OR SAMPLE POPULATION: Twelve pairs of adult equine forelimbs intact from the midradius distally. METHODS: Twelve pairs of equine MC3 were divided into 2 test groups (6 pairs each): torsion and caudocranial 4-point bending. Standard interlocking nails (6-hole, 13-mm diameter, 230-mm length) were placed in 1 randomly selected bone from each pair. Modified interlocking nails (6-hole, 13-mm, 230-mm length, screw holes offset by 30 degrees) were placed in the contralateral bone from each pair. All bones had 1-cm mid-diaphyseal ostectomies. Six construct pairs were tested in caudocranial 4-point bending to determine stiffness and failure properties. The remaining 6 construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t test within each group. Significance was set at P <.05. RESULTS: Mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite, respectively, in 4-point bending were: composite rigidity, 3,119 +/- 334.5 Nm/rad (newton. meter/radian) and 3,185 +/- 401.2 Nm/rad; yield bending moment, 205.0 +/- 18.46 Nm and 186.7 +/- 6.17 Nm; and failure bending moment, 366.4 +/- 21.82 Nm and 378.1 +/- 20.41 Nm. There were no significant differences in the biomechanical values for bending between the 2 fixation methods. In torsion, mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite were: composite rigidity, 135.5 +/- 7.128 Nm/rad and 112.5 +/- 7.432 Nm/rad; gap stiffness, 207.6 +/- 10.57 Nm/rad and 181.7 +/- 12.89 Nm/rad; and yield load, 123.3 +/- 2.563 Nm and 107.5 +/- 8.353 Nm, respectively. Composite rigidity and gap stiffness for standard interlocking-nail fixations were significantly higher than the modified interlocking-nail fixation technique in torsion. Yield load had a tendency to be higher for the standard interlocking-nail fixation (P =.15). CONCLUSIONS: No significant differences in biomechanical properties were identified between a standard interlocking nail and one with the screw holes offset by 30 degrees in caudocranial 4-point bending. The standard interlocking nail was superior to the modified interlocking nail in torsional gap stiffness and composite rigidity. The torsional yield load also tended to be higher for the standard interlocking nail. CLINICAL RELEVANCE: The standard interlocking nail with parallel screw holes is superior to a modified interlocking nail with the screw holes offset by 30 degrees in ostectomized equine MC3 bones in vitro when tested in torsion.

Animals↗

Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws.

OBJECTIVE: To compare the biomechanical characteristics and mode of failure of 2 parallel-screw techniques for proximal interphalangeal joint arthrodesis in horses. STUDY DESIGN: Randomized block design, blocking for horse (1-5), method of screw fixation (three 4.5-mm vs two 5.5-mm), side (left limb vs right limb), and end (front limb vs hind limb). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. SAMPLE POPULATION: Twenty limbs (10 limb pairs) from 5 equine cadavers. METHODS: A combined aiming device was used to facilitate consistent screw placement. Three parallel 4.5-mm cortical screws were placed in lag fashion in 1 limb of a pair, and 2 parallel 5.5-mm cortical screws were placed in lag fashion in the contralateral limb. Arthrodesis constructs were tested in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials-testing machine. Loading rate was 19 mm/s. Maximal bending moment at failure and composite stiffness were obtained from bending moment-angular deformation curves. Data were analyzed using ANOVA and chi(2) analysis. RESULTS: There were no significant differences in bending moment (P >.05, power = 0.8 @ delta = 19%) or composite stiffness (P >.05, power = 0.8 @ delta = 19%) between the 2 fixation techniques. Higher maximal bending moment was found in front limbs than hind limbs, and front limbs with two 5.5-mm screws than hind limbs with two 5.5-mm screws. In all cases, constructs completely failed. A greater number of 4.5-mm cortical screws failed than 5.5-mm cortical screws. CONCLUSIONS-In pastern arthrodesis constructs loaded in 3-point bending, end (front limb vs hind limb) affected maximal bending moment at failure of constructs. There was no significant effect of horse, treatment, or side on maximal bending moment or stiffness. Two 5.5-mm cortical screws should provide a surgically simpler pastern arthrodesis than three 4.5-mm cortical screws while maintaining similar biomechanical characteristics. CLINICAL RELEVANCE: Three 4.5-mm screws or two 5.5-mm screws will provide similar biomechanical characteristics in bending when performing equine pastern arthrodesis.

Animals↗

A modified parainguinal approach for cryptorchidectomy in horses. An evaluation in 107 horses.

A modified parainguinal approach was used to castrate 119 abdominal cryptorchid horses. The operative time ranged from 10 to 30 minutes. Follow-up information was obtained for 107 horses. Swelling, more severe than that expected in routine castrations, was reported in six horses. An incisional abscess had to be drained in one horse and one horse died of unexplained causes 3 days after the surgery.

Animals↗

Fixation of femoral capital physeal fractures with 7.0 mm cannulated screws in five bulls.

Salter-Harris type I fractures of the femoral capital physis were repaired in five Holstein bulls with three 7.0 mm cannulated screws placed in lag fashion. Radiographically at months 7 to 10, the fractures were healed and there was periarticular bone production on the femoral necks and the dorsal acetabular rims. Four bulls had normal gaits, and one bull had muscle atrophy and barely detectable lameness.

Animals↗

A study of the biomechanical properties of the adult equine linea alba: relationship of tissue bite size and suture material to breaking strength.

The purposes of this study were to mechanically determine the optimal tissue bite size and to evaluate seven suture materials at their largest commercially available size for breaking strength and stiffness using cadaveric adult equine linea alba. Soft tissues were removed from the abdominal fascia of 16 adult horses. Individual test sections were created from the entire linea alba and labeled (1 through 6) starting at the umbilicus and extending craniad. A single biomechanical test was performed on each test section. Tissue bite size (3, 6, 9, 12, 15, 18, and 21 mm) significantly altered breaking strength directly in a logarithmic fashion (P < .0001; R2 = 0.94). Tissue bite size accounted for 44% and linea alba thickness for 24% of the variability in breaking strength of the equine linea alba. The optimal tissue bite size for adult horse was 15 mm from the edge of the linea alba based on lack of significant gain in breaking strength. There were no differences in breaking strength among horses, horses weight, or left and right test sections. Test sections taken from near or at the umbilicus had greater breaking strength (P < .005) and thicker linea alba (P < .001) when compared with more cranial test sections. Linea alba thickness alone accounted for 34% of the variability in breaking strength associated with test section position. There were no differences in linea alba stiffness among tissue bite sizes. All suture loops failed before complete fascial disruption, and 52 of 56 (93%) suture loops failed at the knot.(ABSTRACT TRUNCATED AT 250 WORDS)

Abdominal Muscles↗

Effects of 0.05% chlorhexidine lavage on the tarsocrural joints of horses.

In six horses, a 0.05% solution of chlorhexidine diacetate was used to lavage one tarsocrural joint; the contralateral control joint was lavaged with lactated Ringer's solution. Horses were evaluated daily for lameness. Synovial fluid samples were collected on days 1, 4, and 8 for determination of protein concentration, total and differential leukocyte counts, and mucin clot formation. After death on day 8, synovium and osteochondral samples were collected from the tarsocrural joints for examination of morphology and proteoglycan staining. Lavage with chlorhexidine solution caused lameness that was reduced but still evident at day 8. Synovial protein concentration was significantly increased by chlorhexidine lavage; the greatest increase occurred on day 1. Joint lavage increased synovial leukocyte counts on day 1, primarily by increasing polymorphonuclear (PMN) cell counts. Although total synovial leukocyte counts returned to normal by day 4, PMN cell counts remained elevated through day 8; PMN cell counts for chlorhexidine-lavaged joints were typically twice that of control joints. Chlorhexidine lavage caused synovial ulceration, inflammation, and abundant fibrin accumulation. Consistent differences in proteoglycan staining were not detected between control and chlorhexidine-lavaged joints. Joint lavage with 0.05% chlorhexidine diacetate, the lowest known bactericidal concentration, is not recommended for equine joints.

Animals↗

An evaluation of six synthetic casting materials: strength of cylinders in bending.

Six fiberglass casting tapes were evaluated in bending, using an unstable fracture model. Cylindrical casts were constructed and evaluated in bending at 2, 3, and 24 hours after application. Scotchcast Plus (3M, St. Paul, MN), Vet Cast II (3M), and Zim-Flex (Zimmer, Warsaw, IN) were significantly stronger than other materials at 2 hours; however, by 24 hours, casts constructed from Delta-Lite (Johnson & Johnson Products, New Brunswick, NJ) were strongest. Delta-Lite Conformable casts were significantly weaker at all times.

Casts, Surgical↗

An evaluation of fiberglass cast application techniques.

Cylindrical casts constructed from 2, 3, 4, and 5 inch widths of fiberglass casting material were evaluated for strength in bending using an unstable fracture model. Five-inch casting material produced the strongest casts. The effect of longitudinal splinting with 2-inch fiberglass tape was evaluated in cylindrical casts constructed from 4-inch tape. Casts with splints on the compression side or with splints on both the tension and compression sides were stronger in bending than casts with a single splint on the tension side or casts without splints.

Animals↗

In vitro biomechanical comparison of solid and tubular interlocking nails in neonatal bovine femurs.

This study biomechanically evaluates solid and tubular interlocking nails in bovine neonatal femurs. Paired femurs from 40 neonatal dairy calves were obtained for mechanical testing. Intact femurs and four combinations of experimentally manipulated femurs (intact or ostectomized femurs with either a solid or tubular interlocking nail) were tested in craniocaudal and lateromedial bending, eccentric axial compression, and external torsion to evaluate composite rigidity, local/gap stiffness, and load to failure (compression and torsion only). In torsional composite rigidity, femurs with tubular interlocking nails were more complaint than intact femurs or intact femurs with solid interlocking nails (P < .001). Ostectomized femurs with solid interlocking nails were similar to intact femurs with tubular interlocking nails. Within femurs with tubular interlocking nails, ostectomized femurs were more compliant than intact femurs (P < .0001). In craniocaudal and lateromedial bending rigidity, ostectomized femurs were more complaint than intact femurs, regardless of interlocking nail type (P < .001). Within ostectomized femurs, tubular interlocking nails were more complaint than solid interlocking nails in craniocaudal bending (P < .05) and there was a similar trend in lateromedial bending (P = .06). In eccentric axial compression, local/gap stiffness was significantly greater in intact femurs compared with intact femurs with solid (48% of intact bone) or tubular (45% of intact bone) interlocking nails and ostectomized femurs with solid (18% of intact bone) or tubular (11% of intact bone) interlocking nails (P < .0001). In torsional testing, local/gap stiffness was not significantly different between intact femurs and intact femurs with interlocking nails, but was significantly lower in ostectomized femurs with solid (2% of intact bone) and tubular (0.2% of intact bone) interlocking nails (P < .0001).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Laparoscopic repair of scrotal hernia in two foals.

Nonstrangulating indirect scrotal hernias were corrected in two 4-week-old Percheron foals by a laparoscopic technique. After laparoscopic reduction of herniated nonstrangulated small intestine each testes was retracted through the vaginal ring. The ligament of the tail of the epididymis was transected by electrocautery. The testicular vessels and nerves were isolated by cautery of the mesenteric portion of the mesorchium and then ligated. Staples were used to close the opening of the inguinal canal by apposing the peritoneal edges of the vaginal ring. Resection of umbilical stalk remnants via celiotomy performed in one foal after laparoscopic observation of enlargement of the right umbilical artery and urachus. No complications or recurrence of herniation had occurred 16 weeks after surgery.

Animals↗

Laparoscopic cryptorchid castration in standing horses.

OBJECTIVE: This article describes a new technique for laparoscopic cryptorchid castration in standing horses. STUDY DESIGN: Prospective study. ANIMALS OR SAMPLE POPULATION: Eight horses aged 11 months to 3 years and weighing between 300 and 643 kg. METHODS: Food was withheld for 24 to 36 hours, and then horses were sedated with detomidine HCl (0.02 to 0.03 mg/kg) and butorphanol tartrate (0.02 mg/kg). The paralumbar fossa region was desensitized with 2% mepivacaine in an inverted "L" pattern and caudal epidural anesthesia was administered with either xylazine (0.18 mg/kg diluted to 10 to 15 mL with 0.9% sodium chloride) or a combination of 2% mepivacaine and xylazine (0.18 mg/kg). Initial laparoscopic exploration was performed from the left flank; in three horses, right flank laparoscopy was needed to complete the procedure. The spermatic cord was ligated within the abdomen with one or two sutures of 0 polydioxanone suture, and the testis or testes removed through a flank incision. RESULTS: In five horses with no palpably descended testes, standing laparoscopy was the only procedure performed, whereas in two horses, the abdominal testis was removed laparoscopically, and the descended testis was removed under short acting anesthesia. In one horse, with nonpalpable testes, it was determined by laparoscopic observation that the testes were in the inguinal canal, and castration was performed under general anesthesia. No surgical or postoperative complications were noted. The right side of the abdomen, and especially the right vaginal ring, could be easily observed from the left side by passing the laparoscope through a small perforation in the mesocolon of the descending colon or by elevating the descending colon with an instrument or by use of an arm in the rectum. CONCLUSIONS: The standing laparoscopic approach combined with or without short-acting anesthesia to remove the descended testis is easily performed. CLINICAL RELEVANCE: This approach will provide surgeons with another option to castrate cryptorchid stallions.

Anesthesia, General↗

An in vitro biomechanical comparison of an interlocking nail system and dynamic compression plate fixation of ostectomized equine third metacarpal bones.

OBJECTIVE: To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. METHODS: Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad) and one laterally (10 hole, 4.5-mm broad) were attached to the contralateral bone from each pair. All bones had 1 cm mid-diaphyseal ostectomies. Five construct pairs were tested in caudocranial four-point bending to determine stiffness and failure properties. The remaining five construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite, respectively, in four-point bending were: composite rigidity, 3,454+/-407.6 Nm/rad and 3,831+/-436.5 Nm/rad; yield bending moment, 276.4+/-40.17 Nm and 433.75+/-83.99 Nm; failure bending moment, 526.3+/-105.9 Nm and 636.2+/-27.77 Nm. There was no significant difference in the biomechanical values for bending between the two fixation methods. In torsion, mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite were: composite rigidity, 124.1+/-16.61 Nm/rad and 262.4+/-30.51 Nm/rad; gap stiffness, 222.3+/-47.32 Nm/rad and 1,557+/-320.9 Nm/rad; yield load, 94.77+/-7.822 Nm and 130.66+/-20.27 Nm, respectively. Composite rigidity, gap stiffness, and yield load for double plate fixation were significantly higher compared with interlocking nail fixation in torsion. CONCLUSIONS: No significant differences in biomechanical properties were identified between an interlocking nail and double plating techniques for stabilization of ostectomized equine MC3 in caudocranial four-point bending. Double plating fixation was superior to interlocking nail fixation in torsion.

Animals↗

Fire at sea.

Explore the source record for details and available documents.

Burns↗