Search PubMed⌕ Search

Biomedical subjects

D G Schmidt

Publications and source records attributed to D G Schmidt.

At least 19 recordsLinked to original sources

Residual antigenicity of hypoallergenic infant formulas and the occurrence of milk-specific IgE antibodies in patients with clinical allergy.

BACKGROUND: Milk protein hydrolysates are frequently used in milk substitutes for children with cow's milk allergy. However, cases of hypersensitivity to commercially available hypoallergenic infant formulas based on milk protein hydrolysates have been reported. OBJECTIVE: Our purpose was to determine the immunologic response of milk protein-specific IgE and IgG in the serum of patients allergic to cow's milk against four commercially available hypoallergenic milk protein hydrolysates and eight infant formulas. METHODS: Antibody levels in patients' serum and milk protein-specific residual antigenicity of the hypoallergenic products were determined by indirect and competitive ELISA. RESULTS: Patients allergic to cow's milk had IgE and IgG antibodies to several protein fractions of cow's milk; intraindividual and interindividual variation in the concentrations of these antibodies was considerable. In general, IgE and IgG residual antigenicity of individual milk proteins in the hypoallergenic products was lower compared with that of the intact milk protein, but immunoreactive epitopes could still be detected in all products. Their number varied considerably among the individual milk proteins and also differed among products. CONCLUSIONS: The individual sensitization pattern of the patient allergic to cow's milk and the milk protein-specific residual antigenicity might be considered as possible laboratory predictors of adverse reactions to hypoallergenic products. Their determination could be a useful preclinical screening test for pediatricians to select a formula adapted to the individual patient.

Animals↗

Raising the pH of the pepsin-catalysed hydrolysis of bovine whey proteins increases the antigenicity of the hydrolysates.

BACKGROUND: Hypersensitivity to cow milk protein is frequently observed in infancy. Since the pH in the infant's stomach is relatively high (pH 3-4) compared with adults (pH 2), an incomplete digestion of the milk proteins is expected to occur. OBJECTIVE: The determination of the degree of hydrolysis by pepsin of the four main proteins of bovine whey, i.e. alpha-lactalbumin (alpha La), beta-lactoglobulin (beta Lg), bovine serum albumin (BSA) and bovine immunoglobulin G (B-IgG), in the pH range 2.0-4.0 and of the antigenic properties of the resulting hydrolysates. METHODS: Whey proteins were successively hydrolysed with pepsin at pH values ranging from 2.0 to 4.0 and with pancreatic enzymes at pH 7.5 using a pH-stat. The resulting hydrolysates were characterized by their degree of hydrolysis, and analysed by sodium dodecyl sulfate polyacrylamide gel electrophoresis, gel permeation chromatography and immunologically by competitive enzyme-linked immunosorbent assay. RESULTS: In general, the degree of hydrolysis, the gel electrophoretic patterns, the contents of peptides of molecular mass > 5 kDa and the residual human-immunoglobulin E and G antigenicities of the hydrolysates did not differ much whether the pepsin incubation was done at pH 2.0 or 3.0. Pepsin incubation at pH 4.0, however, resulted in a decreased hydrolysis and enhanced residual antigenicity of alpha La, BSA and B-IgG, but not of beta Lg. CONCLUSION: The poor and slow degradation of the antigenic epitopes of whey proteins when pepsin digestion occurs under conditions that prevail in the stomach of infants could be of much importance for the development of cow milk hypersensitivity. The immature gastrointestinal mucosal barrier of infants allows large antigenic fragments of these proteins to pass into the systemic circulation.

Adult↗

Measurements of the electron dose distribution near inhomogeneities using a plastic scintillation detector.

PURPOSE: Accurate measurement of the electron dose distribution near an inhomogeneity is difficult with traditional dosimeters which themselves perturb the electron field. We tested the performance of a new high resolution, water-equivalent plastic scintillation detector which has ideal properties for this application. METHODS AND MATERIALS: A plastic scintillation detector with a 1 mm diameter, 3 mm long cylindrical sensitive volume was used to measure the dose distributions behind standard benchmark inhomogeneities in water phantoms. The plastic scintillator material is more water equivalent than polystyrene in terms of its mass collision stopping power and mass scattering power. Measurements were performed for beams of electrons having initial energies of 6 and 18 MeV at depths from 0.2-4.2 cm behind the inhomogeneities. RESULTS: The detector reveals hot and cold spots behind heterogeneities at resolutions equivalent to typical film digitizer spot sizes. Plots of the dose distributions behind air, aluminum, lead, and formulations for cortical and inner bone-equivalent materials are presented. CONCLUSION: The plastic scintillation detector is suited for measuring the electron dose distribution near an inhomogeneity.

Electrodes↗

Computer-controlled radiochemical synthesis: a chemistry process control unit for the automated production of radiochemicals.

A computer-controlled general purpose chemistry process control unit (CPCU) suitable for the automated production of radiochemicals has been developed. This valve-and-tubing synthesis system can be user programmed to accommodate a variety of chemical processes. In a practical demonstration of its utility, the CPCU has been configured and programmed to synthesize 2-deoxy-2-[18F]fluoro-D-glucose (2-[18F]FDG) using aqueous [18F]fluoride ion. Using this instrument, the yield of 2-[18F]FDG from [18F]fluoride ion is 54.9% (+/- 11.2%, n = 125) corrected to EOB, after a synthesis time of 50-55 min. The average total activity produced (for runs of 5-10 microA) is 28.1 mCi/microA (+/- 5.03 mCi/microA). Thus, the amount of 2-[18F]FDG produced from a 10 microA for 1 h bombardment was 154.3 mCi (+/- 27.4 mCi). The unit has been similarly configured and programmed to synthesize 2-deoxy-2-[18F]fluoro-D-mannose (48% EOB), 3-(2'-[18F]fluoroethyl)spiperone (29% EOB), and [18F]fluoroacetate (66% EOB) from aqueous [18F]-fluoride ion, and 2-[18F]FDG from gaseous acetyl hypo[18F]fluorite (20% EOB).

Computers↗

On the size of small protein particles determined by electron microscopy of unidirectionally shadowed freeze-etched preparations.

The influence exerted by the thickness of the deposited metal layer and the ionic strength of the solution on the apparent size of particles of bovine serum albumin in unidirectionally shadowed freeze-etch preparations of spray-frozen specimens was investigated. It appeared that the size increase due to shadowing is nearly twice the thickness of the deposited metal layer. Apparent particle size was shown to increase linearly with the inverse square root of the ionic strength of the solution. At ionic strength 0.001 the particles appeared about 30% larger than at infinite ionic strength.

Freeze Etching↗

On the size of monomers and polymers of beta-casein.

The size and number average molecular weight have been determined for beta-casein monomers and polymers from electron micrographs using the freeze-etching procedure with spray-frozen specimens. For the spherical beta-casein monomers we found a mol. wt of 22600 and a diam. about 10 nm, which compared quite well with data obtained from ultracentrifugation, light scattering and viscosity measurements. Polymer sizes were in agreement with molecular weight determinations from ultracentrifugation and light scattering, assuming that the volume and weight of the particles are proportional.

Caseins↗

Properties of artificial casein micelles.

A survey is given of the relationships between various properties of artificial casein micelle systems and their composition with respect to alphas1-, beta and kappa-casein, colloidal phosphate and citrate. Properties investigated were: the amount of colloidal phosphate, the micellar size, and the stability of the micelle towards dialysis, pressure, ethanol and heat.

Caseins↗

A nitrosamide-specific detector for use with high-pressure liquid chromatography.

A highly specific automated method for identification of nitrosamides has been developed for use in conjuction with reversed-phase high-pressure liquid chromatography. The method is based on the well-known Griess reagent, and is capable of sensitivities of 0.5 nmoles of injected nitrosamide in most cases. The method may be used for analysis of nitrite, nitrosamides, nitrosocarbamates, and alkylnitrites.

Alkylation↗