Close encounters--an artist shows that size affects shape.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D G Pelli.
Explore the source record for details and available documents.
Measuring the dependence of visual sensitivity on parameters of the visual stimulus is a mainstay of vision science. However, it is not widely appreciated that visual sensitivity is a product of two factors that are each invariant with respect to many properties of the stimulus and task. By estimating these two factors, one can isolate visual processes more easily than by using sensitivity measures alone. The underlying idea is that noise limits all forms of communication, including vision. As an empirical matter, it is often useful to measure the human observer's threshold with and without a noise background added to the display, to disentangle the observer's ability from the observer's intrinsic noise. And when we know how much noise there is, it is often useful to calculate ideal performance of the task at hand, as a benchmark for human performance. This strips away the intrinsic difficulty of the task to reveal a pure measure of human ability. Here we show how to do the factoring of sensitivity into efficiency and equivalent noise, and we document the invariances of the two factors.
A binocular pair of fiberscopes relays high-resolution images of CRT displays from an adjacent room to an observer lying in a scanner in functional Magnetic Resonance Imaging (fMRI) studies of visual function. We review the problems that must be overcome by any visual display for use in fMRI, present the specific solution we developed, and discuss its merits. Together, the fiberscope and CRT conveniently display accurately controlled high- and low-contrast wide-field images to an observer in an fMRI scanner.
The standard working assumption of careful CRT imaging is that each pixel is imaged independently, through a point nonlinearity (the monitor's gamma function, relating screen luminance to input voltage), and then blurred by the point-spread function of the beam spot on the phosphor. Unfortunately most monitors have inadequate video bandwidth, DC restoration, and high-voltage regulation to live up to this ideal model. Two tests are recommended for assessing a CRT's deviation from the pixel-independence model.
The VideoToolbox is a free collection of two hundred C subroutines for Macintosh computers that calibrates and controls the computer-display interface to create accurately specified visual stimuli. High-level platform-independent languages like MATLAB are best for creating the numbers that describe the desired images. Low-level, computer-specific VideoToolbox routines control the hardware that transforms those numbers into a movie. Transcending the particular computer and language, we discuss the nature of the computer-display interface, and how to calibrate and control it.
We hear periodic sounds, or tones, by means of parallel auditory filters, each tuned to a band of temporal frequency, and we see periodic patterns, or gratings, by means of parallel visual filters, each tuned to a band of spatial frequency. Beyond helping us to see gratings, do these visual filters participate in everyday tasks such as reading and object recognition? After all, grafting visibility only requires the distinguishing of pattern from blank, whereas object recognition, for example letter identification, requires classification by the observer into one of many learned categories. Here we make use of results from hearing research, applying to vision a noise-masking paradigm that reveals the filter(s) mediating any threshold task. We find that letter-identification and grating-detection filters are identical, showing that the recognition of these objects at one size is mediated and constrained by a single visual filter, or 'channel'.
Observers were asked to locate a target in a brief, two-scale display. Accuracy of locating the target was measured as a function of the ratio between the two scales. At each scale ratio, the probability of locating the target as a function of the number of elements is well fit by the idea that the observer accurately monitors only a "critical" number of elements. The dependence of critical number on scale ratio is well accounted for by a model that assumes that the observer's decision is based on an evenly spaced array of samples. The sample spacing is under attentional control, but is always uniform.
Evidence from several sources suggests that visual attention is tuned to stimulus scale. This tuning impairs performance when the observer must attend to more than one scale at a time. In experiments originally designed to measure the bandwidth of attention to stimulus scale, we have found tasks in which observers show no attentional tuning for scale. In separate blocks, observers located or identified targets in arrays of elements, either numbers in arrays of letters or static squares in arrays of flashing squares. Each display contained two arrays, either of the same scale or of different scales. The accuracy of locating the target element was lower in mixed-scale than in single-scale displays, but the accuracy of identifying the target was unaffected by a mixing of scales within the same display. This holds for both high-level discriminations--numbers vs letters--and low-level discriminations--static vs flashing. Thus, at least for identifying, one can attend to large and small at the same time. The difference in bandwidth between "what" and "where" implies that stimulus identification is not dependent on prior localization.
Is visual attention mediated by a general-purpose processor with a small data capacity? Such an attentive processor could perform a wide range of transformations upon a small amount of image data. We suggest that this limited capacity corresponds to a fixed amount of information, measured in bits. We measure how much information an observer's attention can handle by measuring how much we can restrict display information without impairing the observer's performance. The attentive visual tasks we study are the detection of a stationary dot in a field of moving dots, and the detection of a static square in a field of flashing squares. Performance of these tasks is perfect up to a critical number of elements (the span of attention) and then falls as the number of elements increases beyond this critical number. The display information required for unimpaired performance in each of these tasks is low; the results indicate that visual attention processes only 30 to 60 bits of display information.
Vibrotactile thresholds for detecting a 300-Hz signal in the presence of both a 300-Hz sinusoidal pedestal and a background noise were measured as a function of the amplitudes of the pedestal and noise. Threshold increased monotonically as a function of the amplitude of the noise, but was a nonmonotonic function of the amplitude of the sinusoidal pedestal. Negative masking, in which the pedestal facilitated detection of the test stimulus, was observed in the absence of background noise and in the presence of subthreshold background noise when the pedestal was near or below threshold. Negative masking disappeared when the experiment was conducted in the presence of moderately intense to intense background noise. The results are consistent with a peripheral high-energy threshold for taction.
Off-the-shelf microcomputers can now display arbitrary 8-bit images, but accurate control of these images requires dealing with several undesirable properties of real digital to analog converters (DACs) and analog video monitors. The limitations of DACs and video monitors are presented in the form of a model for their calibration and use in vision experiments. Low contrasts can be accurately rendered by summing a small accurate a.c. signal and a large less-accurate d.c. signal (Watson et al., 1986; Behavior Research, Method, Instrument and Computers, 18, 587-594). Exploiting that idea, this note presents an easy-to-build passive resistor network, a video attenuator, that combines the outputs of three 8-bit DACs to render low contrasts with 12-bit accuracy at the display. Measurements confirm the 12-bit accuracy.
The eye of the 'eyeless' shrimp Rimicaris exoculata is unusual in having no image-forming optics and a high concentration of rhodopsin. The shrimps swarm around 350 degrees C hydrothermal 'black smoker' vents in the Mid-Atlantic Ridge. There is no other known source of visible light in the shrimp's environment. The spectral sensitivity of rhodopsin is well matched to typical spectra of bioluminescence of organisms found at lesser depths, but other animals detect such emissions without the unusual features of the R. exoculata eye. These two features are most easily understood as an adaptation for the detection of extremely faint sources of light. Physical calculations presented here indicate that the shrimp could see the black-body radiation of the 350 degrees C vents, even though these sources are practically invisible to the human eye. This would be useful to the shrimp as it feeds on sulphide-loving bacteria very near to the vents but must avoid the lethal 350 degrees C vents themselves.
Explore the source record for details and available documents.
Summation refers to the small reduction of threshold contrast as a signal is extended in space or time, or when multiple signals are presented simultaneously. Facilitation refers to the large reduction in the threshold contrast increment when it is superimposed on a near-threshold pedestal contrast. Separate hypotheses relate each of these effects to distinct measures of the log-log steepness of the psychometric function. This note shows that for 2-alternative forced-choice (2afc) proportion correct, the Weibull function P(c) = 1-(1-gamma) exp[-(c/alpha) beta] and the d' power law d'(c) = (c/c0.76)b are practically indistinguishable. Furthermore, their steepness parameters are proportional to each other, beta = 1.247 b. This implies a simple relation between 2afc summation and facilitation which can be tested without measuring the psychometric function.
A tactile stimulator array constructed from 88 piezoelectric ceramic plates is described. The array can produce sinusoidal traveling waves with arbitrary temporal frequency, spatial wavelength, and amplitude. Detection thresholds were measured for five temporal frequencies (1, 4, 16, 64, and 256 Hz) and five spatial wavelengths (1.81, 3.62, 7.23, 14.5, and infinity mm), and were plotted as a three-dimensional, spatiotemporal threshold surface. Detection thresholds were also measured using a conventional vibrator and a large circular contactor simulating the infinite wavelength stimulus produced by the array. The results describe the spatial and temporal frequency sensitivity of the P and NP I cutaneous receptor populations.
An important goal of auditory physiology is to relate the coding of signals in the auditory nerve to behavioral sensitivity. A useful step towards that goal is to measure physiological thresholds for the detection of tones in the neural spike train that are comparable to psychophysical thresholds. Detectability depends on the variability as well as the mean value of the response. A two-interval forced-choice task provides a criterion-free measure of detectability. On each trial of our experiments a probe tone was taken to be correctly detected if the number of spikes in response to the tone exceeded the number of spikes in an otherwise identical interval that did not contain the probe tone. (Analysis of the pulse-number distributions also allowed construction of ROC curves directly comparable to psychophysical ROC curves.) The proportion of trials that yielded correct detections was measured as a function of stimulus intensity to form a neurometric function, directly comparable to a psychophysical psychometric function. Threshold was defined as the intensity that produced a given proportion correct. The threshold intensity was also measured by an up-down procedure. Agreement between the two measures of threshold was excellent. Using the up-down procedure we could measure threshold in about 1 min, making it practical to measure the thresholds of a single neuron for many conditions. Comparisons of physiological and psychophysical ROC curves and neurometric and psychometric functions show systematic differences indicating that the animal makes its decisions inefficiently, perhaps by basing its decision on the maximum response among many neurons, rather than just the activity of the single most sensitive neuron.
This paper is about the visual requirements for reading with normal vision. It is the first in a series devoted to the psychophysics of reading with normal and low vision. We have measured reading rates for text scanned across the face of a TV monitor while varying parameters that are important in current theories of pattern vision. Our results provide estimates of the stimulus parameters required for optimal reading of scanned text. We have found that maximum reading rates are achieved for characters subtending 0.3 degree to 2 degrees. Contrast polarity (black-on-white vs white-on-black text) has no effect. Reading rate increases with field size, but only up to 4 characters, independent of character size. When text is low-pass spatial-frequency filtered, reading rate increases with bandwidth, but only up to two cycles/character, independent of character size. When text is matrix sampled, reading rate increases with sample density, but only up to a critical sample density which depends on character size. The critical sample density increases from about 4 X 4 samples/character for 0.1 degree characters to more than 20 X 20 samples/character for 24 degrees characters. We suggest that one spatial-frequency channel suffices for reading.
Very little is known about the effects of visual impairment on reading. We used psychophysical methods to study reading by 16 low-vision observers. Reading rates were measured for text scanned across the face of a TV monitor while varying parameters that are likely to be important in low vision: angular character size, number of characters in the field, number of dots composing each character, contrast polarity (white-on-black vs black-on-white text), and character spacing. Despite diverse pathologies and degrees of vision loss in our sample, several major generalizations emerged. There is a wide variation in peak reading rates among low-vision observers, but 64% of the variance can be accounted for by two major distinctions: intact central fields vs central-field loss and cloudy vs clear ocular media. Peak reading rates for observers with central-field loss were very low (median 25 words/minute), while peak reading rates for observers with intact central fields were at least 90 words/minute (median 130 words/minute). Most low-vision readers require magnification to obtain characters of optimal size. Sloan M acuity was a better predictor of optimal character size than Snellen acuity, accounting for 72% of the variance. Low-vision reading is similar to normal reading in several respects. For example, both show the same dependence on the number of characters in the field. Our results provide estimates of the best reading performance to be expected from low-vision observers with characteristic forms of vision loss, and the stimulus parameters necessary for optimal performance. These results will be useful in the development of clinical tests of low vision, and in the design of low-vision reading aids.