Search PubMed⌕ Search

Biomedical subjects

D G Martin

Publications and source records attributed to D G Martin.

76 records · Page 5Linked to original sources

Review of the carotid artery loop procedure in sheep.

Carotid loop (CL) surgery involves the permanent externalization of a common carotid artery in a skin tube. The CL facilitates repeated access to the systemic arterial system for blood sampling and blood pressure measurement in laboratory sheep. It eliminates the need for arterial cut-downs and chronic indwelling catheters, reduces the risk of sepsis and infection, and adds flexibility to research protocols. The surgical procedure is aseptically performed under general anesthesia and involves isolation of the common carotid artery, creation of a bipedicled skin tube, and permanent envelopment of the artery in the skin tube. The primary complication is ischemic necrosis with sloughing of the middle of the loop and is usually due to failure to adhere to the critical length-to-width ratio (2.5:1). We have performed 150 CL procedures with an overall success rate of 94%. Nine CL ablations were required, due to necrosis with exposure of the artery (7/9) or stricture formation with loss of patency (2/9). Twenty-two CLs developed complications secondary to partial necrosis, but did not require ablation. Results indicate that the CL is a reliable method to ensure repeated access to the systemic arterial system in sheep. A modification of the standard CL procedure in which the artery is surrounded by a skin tunnel rather than enclosed in a skin loop was performed in 10 sheep. Preliminary results indicate significant reduction in the incidence of complications associated with the standard CL.

Animals↗

Automation and computerization of chromogenic LAL assay method for bacterial endotoxin using 96-well microtiter plate.

A high degree of automation was achieved for a chromogenic substrate Limulus amebocyte lysate (LAL) assay method for bacterial endotoxin using a Cetus Pro/Group Liquid Handler and 96-well microtiter plates. A Titertek Multiskan Reader was interfaced with an IBM PC using a LOTUS MEASURE software to capture optical density values of samples in a LOTUS 1-2-3 spreadsheet. A password protected, menu-driven macro programmed in LOTUS 1-2-3 automates the calculation, evaluation of assay parameters, documentation, and generation of a formatted three-page report suitable as a primary record. All assay operations, including testing 19 samples against a four-point standard curve in replicates of four each, the calculation of results, and generation of a report, are completed in less than 40 minutes. The relative standard deviation (RSD) of the assay is approximately 7%, which compares favorably with the robot automated system.

Automation↗