Search PubMed⌕ Search

Biomedical subjects

D Flanagan

Publications and source records attributed to D Flanagan.

At least 19 recordsLinked to original sources

A survey of measures used for the prevention of postoperative endophthalmitis after cataract surgery in the United Kingdom.

PURPOSE: This study investigates the current practice of United Kingdom (UK) ophthalmologists in perioperative antibiotic and antiseptic use in cataract surgery. MATERIALS AND METHODS: A telephone interview survey was conducted with ophthalmic staff at all ophthalmic training units in the UK in October and November 2005. RESULTS: The practices of a total of 800 consultants were ascertained. Preoperatively, 795 (99.4%) surgeons used povidone-iodine to prepare the skin. In all, 558 (69.8%) instilled 5 or 10% povidone-iodine in the conjunctival sac; 47 (5.9%) gave preoperative antibiotic eyedrops. Intraoperatively, intracameral antibiotics were given either as a bolus [80 (10.0%) intracameral cefuroxime, 29 (3.6%) intracameral vancomycin] or in the irrigating fluid [33 (4.1%) vancomycin]. 48 (6.0%) gave subconjunctival gentamycin only routinely, 531 (66.4%) gave subconjunctival cefuroxime, and 39 (4.9%) gave other subconjunctival antibiotics. A single dose of topical antibiotics was given by 134 (16.8%) surgeons. Postoperatively, 515 (64.4%) used a combination steroid and neomycin eyedrop, and 213 (26.6%) gave a separate steroid and chloramphenicol eyedrop. CONCLUSIONS: This study reveals wide variations in the choice and duration of antibiotics used by UK ophthalmologists. The predominant methods of intraoperative prophylaxis are subconjunctival cefuroxime and intracameral cefuroxime. Most surgeons used a neomycin eyedrop for postoperative prophylaxis.

Anti-Bacterial Agents↗

Defective macrophage function in neonates and its impact on unresponsiveness of neonates to polysaccharide antigens.

Neonates do not respond to thymus-independent (TI) antigens (Ag), making them vulnerable to infection with encapsulated bacteria. The antibody (Ab) response of adult and neonatal B cells to TI Ag requires certain cytokines, which are provided by T cells or macrophages (MPhi). Lipopolysaccharide (LPS) failed to induce neonatal MPhi to produce interleukin (IL)-1beta and tumor necrosis factor alpha (TNF-alpha) mRNA and to secrete IL-1beta, IL-12, and TNF-alpha. However, LPS induced neonates to secrete some IL-6 and three- to fivefold more IL-10 than adults. Accordingly, adding adult but not neonatal MPhi could restore the response of purified adult B cells to trinitrophenol (TNP)-LPS, a TI Ag. Increased IL-10 is causally related to decreased IL-1beta and IL-6 production, as IL-10(-/-) neonatal MPhi responded to LPS by secreting more IL-1beta and IL-6 than wild-type (WT) neonatal MPhi. When cultures were supplemented with a neutralizing Ab to IL-10, WT neonatal MPhi secreted increased amounts of IL-6 and allowed neonatal MPhi to promote adult B cells to mount an Ab response against TNP-LPS. Thus, neonates do not respond to TI Ag as a result of the inability of neonatal MPhi to secrete cytokines, such as IL-1beta and IL-6, probably as a result of an excess production of IL-10. This dysregulated cytokine secretion by neonatal MPhi may be a result of a reduction in expression of Toll-like receptor-2 (TLR-2) and TLR-4 and CD14.

Animals↗

Improvement in the performance of automated spike detection using dipole source features for artefact rejection.

OBJECTIVE: We evaluated the use of an efficient dipole source algorithm to improve performance of automated spike detection by identifying false detections caused by artefacts. METHODS: Automated spike detections were acquired from 26 patients undergoing prolonged electroencephalograph (EEG) monitoring. Data from 6 patients were used to develop the method and data from 20 patients were used to test the method. To provide a standard against which to evaluate the results, an electroencephalographer (EEGer) visually categorized all automated detections before the dipole models were calculated for all events. The event categories (as defined by the EEGer) were then combined with properties of the dipole model and features were identified that differentiated spike and artefact detections. The resulting method was then applied to the testing data set. RESULTS: Residual variance and eccentricity of the dipole models differentiated artefact and spike detections. A separate set of rules defining eye blink artefact was also developed. The combined criteria removed a mean of 53.2% of artefact from the testing data set. Some spike detections (4.3%) were also lost. CONCLUSIONS: The features of the dipole source of a detected event can be used to differentiate artefacts from spikes. This algorithm is computationally light and could be implemented on-line.

Electroencephalography↗

Improving quality measures in the emergency services.

A large and continuing increase in medical emergency admissions has coincided with a reduction in hospital beds, putting the acute medical services under great pressure. Increasing specialization among physicians creates a conflict between the need to cover acute unselected medical emergencies and the pressure to offer specialist care. The shortage of trained nursing staff and changes in the training of junior doctors and the fall in their working hours contribute to the changing role of the consultant physician. The organization of the acute medical service is of paramount importance and requires multi-disciplinary teamwork on an admissions unit with full support services. Excellent bed management is essential. There must be guidelines for all the common medical emergencies and all units must undertake specific audits of the acute medical service. Continuing professional development (CPD) and continuing medical education (CME) should reflect the workload of the physician; that is, it must include time specifically focused on acute medicine and general (internal) medicine, as well as the specialty interest.

Emergency Service, Hospital↗

High and low torque handpieces: cutting dynamics, enamel cracking and tooth temperature.

OBJECTIVE: The aim of these experiments was to compare the cutting dynamics of high-speed high-torque (speed-increasing) and high-speed low-torque (air-turbine) handpieces and evaluate the effect of handpiece torque and bur type on sub-surface enamel cracking. Temperature changes were also recorded in teeth during cavity preparation with high and low torque handpieces with diamond and tungsten carbide (TC) burs. The null hypothesis of this study was that high torque handpieces cause more damage to tooth structure during cutting and lead to a rise in temperature within the pulp-chamber. MATERIALS AND METHODS: Images of the dynamic interactions between burs and enamel were recorded at video rate using a confocal microscope. Central incisors were mounted on a specially made servomotor driven stage for cutting with a type 57 TC bur. The two handpiece types were used with simultaneous recording of cutting load and rate. Sub-surface enamel cracking caused by the use of diamond and TC burs with high and low torque was also examined. Lower third molars were sectioned horizontally to remove the cusp tips and then the two remaining crowns cemented together with cyanoacrylate adhesive, by their flat surfaces. Axial surfaces of the crowns were then prepared with the burs and handpieces. The teeth were then separated and the original sectioned surface examined for any cracks using a confocal microscope. Heat generation was measured using thermocouples placed into the pulp chambers of extracted premolars, with diamond and TC burs/high-low torque handpiece variables, when cutting occlusal and cervical cavities. RESULTS: When lightly loaded the two handpiece types performed similarly. However, marked differences in cutting mechanisms were noted when increased forces were applied to the handpieces with, generally, an increase in cutting rate. The air turbine could not cope with steady heavy loads, tending to stall. 'Rippling' was seen in the interface as this stall developed, coinciding with the bur 'clearing' itself. No differences were noted between different handpieces and burs, in terms of sub-surface enamel cracking. Similarly, no differences were recorded for temperature rise during cavity preparation. CONCLUSIONS: Differences in cutting mechanisms were seen between handpieces with high and low torque, especially when the loads and cutting rates were increased. The speed increasing handpiece was better able to cope with increased loading. Nevertheless, there was no evidence of increased tooth cracking or heating with this type handpiece, indicating that these do not have any deleterious effects on the tooth.

Analysis of Variance↗

What should we do? Papillary thyroid carcinoma in a lymph node but normal thyroid tissue--how should we proceed?

Papillary cell carcinoma of the thyroid is a relatively indolent disease, usually presenting as an asymptomatic mass in the thyroid gland that is either noted by the patient or diagnosed at routine clinical examination. Although the prognosis is generally good there are a number of controversies in the management of this condition. The significance of age at presentation, size of the tumour and the presence of lymph node metastasis are still disputed. We present the unusual case of a woman found to have papillary cell thyroid carcinoma within a lymph node during a cosmetic thyroid lobectomy. The thyroid tissue removed was not found to contain tumour. We describe the evidence behind the decision to proceed to total thyroidectomy and the finding of a tiny focus of papillary cell thyroid carcinoma within the contralateral lobe.

Adult↗

A method for estimating preoperative bone volume for implant surgery.

This is a simple method for estimating preoperatively the underlying bone volume of a proposed edentulous site for dental implant placement. It entails a localized imprint of the ridge, measurement of the depth of the overlying gingival of the site, and correlating the measurements on a tracing of the ridge arch taken from the imprint. The resultant shape shows a slice of the underlying bone, giving the surgeon insight regarding the width of implant the site will accept, angulation, and the need for bone augmentation.

Alveolar Bone Loss↗

An expert system for EEG monitoring in the pediatric intensive care unit.

OBJECTIVES: was to design a warning system for the pediatric intensive care unit (PICU). The system should be able to make statements at regular intervals about the level of abnormality of the EEG. The warnings are aimed at alerting an expert that the EEG may be abnormal and needs to be examined. METHODS: A total of 188 EEG sections lasting 6 h each were obtained from 74 patients in the PICU. Features were extracted from these EEGs, and with the use of fuzzy logic and neural networks, we designed an expert system capable of imitating a trained EEGer in providing an overall judgment of abnormality about the EEG. The 188 sections were used in training and testing the system using the rotation method, thus separating training and testing data. RESULTS: The EEGer and the expert system classified the EEGs in 7 levels of abnormality. There was concordance between the two in 45% of cases. The expert system was within one abnormality level of the EEGer in 91% of cases and within two levels in 97%. CONCLUSIONS: We were therefore able to design a system capable of providing reliably an assessment of the level of abnormality of a 6 h section of EEG. This system was validated with a large data set, and could prove useful as a warning device during long-term ICU monitoring to alert a neurophysiologist that an EEG requires attention.

Algorithms↗

Automatic EEG analysis during long-term monitoring in the ICU.

To assist in the reviewing of prolonged EEGs, we have developed an automatic EEG analysis method that can be used to compress the prolonged EEG into two pages. The proposed approach of Automatic Analysis of Segmented-EEG (AAS-EEG) consists of 4 basic steps: (1) segmentation; (2) feature extraction; (3) classification; and (4) presentation. The idea is to break down the EEG into stationary segments and extract features that can be used to classify the segments into groups of like patterns. The final step involves the presentation of the processed data in a compressed form. This is done by providing the EEGer with a representative sample from each group of EEG patterns and a compressed time profile of the complete EEG. To verify the above approach, 41 6 h EEG records were assessed for normality via the AAS-EEG and conventional EEG approaches. The difference between the overall assessment via compressed and conventional EEG was within one abnormality level 100% of the time, and within one-half level for 73.6% of the records. We demonstrated the feasibility and reliability of automatically segmenting and clustering the EEG, thus allowing the reduction of a 6 h tracing to a few representative segments and their time sequence. This should facilitate review of long recordings during monitoring in the ICU.

Child↗

Outpatient assessment of residual growth hormone secretion in treated acromegaly with overnight urinary growth hormone excretion, random serum growth hormone and insulin like growth factor-1.

OBJECTIVE: To assess the outpatient investigations, overnight urinary growth hormone (uGH) excretion, random serum GH and insulin like growth factor 1 (IGF-1), and GH indices from the oral glucose tolerance test (OGTT) (fasting, nadir and mean GH), as measures of mean GH secretion in treated acromegaly, in comparison with a GH day series, which served as a gold standard. DESIGN: Prospective cross-sectional study, with patients admitted to a metabolic ward for the following investigations: random GH, IGF-1, 6 point GH day series (day 1), 9 h timed overnight uGH excretion, OGTT with GH response (day 2). Agreements between the mean GH during the day series and the other outcome measures, and the diagnostic performance of the latter, for the presence or absence of active acromegaly (mean GH during day series > or = 5 or < 5 mU/l, respectively) were determined. PATIENTS: 26 patients with treated acromegaly (11 with inactive acromegaly off drug therapy). MEASUREMENTS: Serum GH and uGH were measured by immunoradiometric assays and IGF-1 by radioimmunoassay. RESULTS: Agreements with the mean GH during the day series were perfect for the nadir GH during the OGTT with a 2 mU/l cutoff (Cohen's kappa (kappa) = 1, P < 0.00001), almost perfect for the fasting and mean GH throughout the OGTT (both kappa = 0.92, P < 0.0001) and random GH (kappa = 0.85, P < 0.0001), and substantial for the nadir GH with a 5 mU/l cutoff (kappa = 0.77, P < 0.0001), IGF-1 (kappa = 0.62, P < 0.001) and overnight uGH excretion (kappa = 0.61, P = 0.002). Nadir GH with a 2 mU/l cutoff was completely accurate for diagnosing the presence or absence of active acromegaly (positive and negative predictive values (% +/- standard error percentage) 100 +/- 8% and 100 +/- 10%). None of the outpatient tests used alone was an adequate diagnostic test (positive and negative predictive values: overnight uGH excretion -86 +/- 10% and 75 +/- 13%; random GH -100 +/- 11% and 85 +/- 11%; IGF-1 -92 +/- 10% and 71 +/- 13%) and so combinations of tests were assessed. The best was overnight uGH excretion plus random GH (positive and negative predictive values 88 +/- 9% and 100 +/- 12%). Using all three outpatient investigations, the positive predictive value of three raised results was 100 +/- 13%. CONCLUSIONS: In treated acromegaly, residual GH secretion can be reliably assessed with the OGTT, using standard diagnostic criteria. It can also be assessed on an outpatient basis with overnight uGH excretion and random GH, as direct measures, and IGF-1. If these are all normal, active acromegaly is excluded. Three raised results denote active acromegaly, and one or two raised results would need further investigation with a GH day series.

Acromegaly↗

Gin and tonic and reactive hypoglycemia: what is important-the gin, the tonic, or both?

The objectives of this study were to test the hypothesis that alcohol can cause reactive hypoglycemia by attenuating the release of counterregulatory hormones. The subjects were eight healthy volunteers (five men and three women, aged 20-40 yr). Each subject drank, using a randomized, double blind design 1) three large gin with regular tonics (0.5 g/kg alcohol and 60 g carbohydrate, mainly sucrose (G+T); 2) the same amount of alcohol with Slim-line tonic (0.5 g carbohydrate; G alone); and 3) regular tonic without alcohol (T alone). Glucose, insulin, and counterregulatory hormone levels and middle cerebral artery velocity (MCAV), an index of cerebral blood flow, were measured. Alcohol levels averaged 60-70 mg/dL. Peak insulin levels were similar in both studies in which regular tonic was consumed (95% confidence interval for difference, -6 to 22 microU/mL). After the ingestion of G+T, the blood glucose nadir was lower compared to that with T alone (3.35 vs. 3.87 mmol/L; P < 0.02) or G alone (3.35 vs. 3.95 mmol/L; P < 0.01). After drinking gin, subjects reported typical hypoglycemic warning symptoms unrelated to the prevailing glucose level. In both alcohol studies, there was marked blunting of GH release (P < 0.01). Despite a blood glucose nadir of 3.35 mmol/L, plasma epinephrine levels rose only slightly from 267 to 455 pmol/L (P = NS) after G+T. Ingestion of alcohol also caused a transient rise in right MCAV (P < 0.05) followed by a late drop in velocity in both cerebral hemispheres in the G+T study (P < 0.05). In otherwise healthy individuals a combination of gin and regular tonic can induce reactive hypoglycemia. Acute ingestion of alcohol impairs the epinephrine response and markedly suppresses the release of GH in response to a fall in blood glucose levels.

Adult↗

Automatic seizure detection in the newborn: methods and initial evaluation.

Seizures are most common in the newborn period, but at that age seizures can be very difficult to identify by clinical observation. Therefore the EEG plays an even greater role in newborns than in older children and adults. The electrographic features of seizures and EEG background in the newborn are, however, very different to those found in adults. We present a set of methods for the automatic detection of seizures in the newborn. The methods are aimed at detecting a wide range of patterns, including rhythmic paroxysmal discharges at a wide range of frequencies, as well as repetitive spike patterns, even when they are not very rhythmic. The methods were developed using EEGs obtained from 55 newborns, recorded at 3 hospitals that used differing monitoring protocols. A total of 281 h of recordings containing 679 seizures were analyzed. An initial evaluation indicated that 71% of the seizures and 78% of seizure clusters (group of seizures separated by less than 90 s) were detected, with a false detection rate of 1.7/h. The methods were developed so that they can be implemented to operate in real time.

Electroencephalography↗

Evaluation of an automatic seizure detection method for the newborn EEG.

In another publication, we described a set of methods for automatic detection of EEG seizures in the newborn. We describe here the evaluation of these methods using a completely new set of data, which were not used in developing the method. This testing data set consisted of recording from 54 patients, lasting an average of 4.4 h. Recordings had 8-16 channels and were obtained, in approximately equal numbers, from 3 institutions in Canada, the USA and Australia. Recording conditions varied from short recordings fully attended by a technologist to overnight recordings largely unattended. The average seizure detection rate was 69% (77%, 53%, 84% in the 3 institutions). False detections occurred at the average rate of 2.3/h (4.1, 1.0, 2.7 in the 3 institutions), with fluctuations that reflected largely the technical quality and level of supervision of the recordings. The results are similar to those obtained in the commonly used method of epilepsy monitoring in adults and allow us to envisage clinical application.

Electroencephalography↗

Outcome of neonates with electrographically identified seizures, or at risk of seizures.

A prospective study was conducted to investigate survival at 1 month and survival and developmental outcome at 1 year in a cohort of 53 neonates either suspected of or at risk of having seizures. For all patients, presence of seizures, diagnoses, and structural abnormalities were identified. If seizures were present, seizure variables were quantified. Correlations between neonatal parameters and subsequent outcome were investigated. Forty-three patients survived the first month of life. Background EEG was the only significant predictor of survival at 1 month. Three patients died after 1 month, and 2 of the three had extremely depressed interictal EEGs. Development outcome at 1 year was determined for all available surviving patients. Abnormal findings from brain imaging studies and number of independent electrographic seizure foci were correlated with some aspects of outcome at 1 year. No other correlations were identified between neonatal parameters and outcome.

Child Development↗

Caval umbrella causing obstructive uropathy.

A 49-year-old woman had a vena caval filters inserted having suffered multiple pulmonary emboli and a large upper gastrointestinal bleed. She re-presented five years later with loin pain and obstructive uropathy. She was found to have a right pelvi-ureteric obstruction due to inferior vena caval wall perforation from the vena caval filter.

Female↗