Day case permanent pacing.

We have previously reported our preliminary experience of day-case permanent pacing in the United Kingdom. The study has now been extended to 50 patients with follow-up of 22 +/- 4 months. During the study period, all patients referred for permanent pacing, either to the senior author, or as in-hospital transfers, were considered for the study. Forty two percent of patients considered fulfilled inclusion and exclusion criteria, resulting in a total of 50 patients being randomized either to day case or conventional in-patient management. In the first month postimplantation, one patient in each group developed a complication requiring revision of system. Only one further pacing related complication occurred over the follow-up period, percutaneous extrusion of a fixation sleeve with spontaneously healing of the wound. This was in a day-case patient. Mean duration of in-patient stay was 5.7 hours in day-case patients, compared with 70.0 hours in those managed conventionally. Postimplantation local physician consultation rates were equal in both groups. Questionnaires were used to determine the relative acceptability to patients of the two management protocols; on a ten point score of acceptability, the mean score for both groups was 8.8. The difference in cost per patient using day-case management was approximately 430 ($817) pounds. We conclude that day-case permanent pacing in the United Kingdom is feasible, acceptable to patients, and has considerable economic benefits.

Aged↗

Influence of propranolol on the ventricular depolarization gradient.

Sensing of the ventricular depolarization gradient (VDG) has recently been used as the basis of a closed-loop rate responsive pacemaker. Factors influencing this aspect of the evoked response have not been fully evaluated although previous reports have suggested that sympathetic stimulation and circulating catecholamines are primarily responsible for the observed changes during stress and exercise. In five patients (Table I), four males and one female (mean age 60.4 +/- 10.1 years) implanted with the Prism pacemaker, the pacing response to exercise and tilting was assessed before and after the infusion of propranolol. There was an increase in the pacing rate in all patients during the infusion of the drug (mean 27 +/- 12.9 beats/min) suggestive of a direct drug effect on the VDG. The rate control parameter (RCP) of the pacemaker, the numerical equivalent of the VDG, was significantly different after the administration of propranolol (P less than 0.01). However, exercise performance and pacing rate behavior were not different after beta blockade. The pacing rate increase observed when tilting patients to the supine position was not altered by propranolol. Out date suggest that factors other than adrenergic stimulation may be of importance in affecting the ventricular evoked response and accordingly the rate adaptation of the Prism pacemaker.

Adrenergic beta-Antagonists↗

Alcohol ablation of atrioventricular conduction.

Transcoronary ablation of atrioventricular conduction by dehydrated alcohol was attempted in 14 patients with refractory atrial arrhythmias. Alcohol (0.5 or 1.0 ml) was delivered after selective catheterisation of the atrioventricular nodal artery in the 10 patients in whom the artery could be identified by cineangiography. The other four patients underwent electrical ablation when the nodal artery could not be catheterised. Temporary atrioventricular block induced by dilute contrast and cold saline (0.9%) confirmed that the catheter was in the correct position before the alcohol was delivered. In all 10 patients complete atrioventricular block developed after alcohol ablation. The block persisted in all four patients given 1.0 ml alcohol but not in four of the six given 0.5 ml. The mean (SD) creatine kinase (MB fraction) at four to six hours after ablation was 76.5 (49.5) IU after 1.0 ml and 75.5 (43.1) IU after 0.5 ml alcohol (normal less than 20 IU). The overall success rate of alcohol ablation in the whole group on an "intention to treat" basis was 43%. The procedure was a technical success in six of the 10 patients in whom the nodal artery was identified. Transcoronary alcohol ablation of atrioventricular conduction should be considered in patients in whom electrical techniques have been unsuccessful.

Aged↗

Early experience with low speed rotational angioplasty.

OBJECTIVE: Preliminary assessment of the efficacy and safety of the low speed rotational angioplasty catheter system (ROTACS). DESIGN: Open prospective trial. SETTING: Department of cardiology in a teaching hospital. PATIENTS: Eleven patients (10 with chronic stable angina and one with acute coronary occlusion after conventional angioplasty) in whom a coronary angiogram showed occlusion or critical stenosis of the coronary artery (right in seven patients, circumflex in two, and left anterior descending in two). The nature or severity of the lesion ruled out conventional coronary angioplasty. INTERVENTIONS: An attempt was made to cross the lesion with a rotating guide wire with a blunt swelling at its tip. Where necessary progress was assessed by simultaneous injection of contrast into both main coronary arteries. MAIN OUTCOME MEASURES: Progress of the ROTACS through the lesion that allowed a guide wire to pass into the distal vessel was regarded as a device specific success. When a guide wire crossed the lesion aided only by the support of the ROTACS without the use of rotation this was counted as a success that was not device specific. Failure to cross the lesion and any associated complications were noted. RESULTS: The ROTACS crossed only two of the 10 chronic lesions (20% device specific success rate); however, the support it provided enabled a guide wire to cross a further two lesions and allowed subsequent successful angioplasty in four of the 10 patients. One of these four patients presented after five months with recurrent angina requiring bypass grafting. The other three were symptom free at follow up seven months after the procedure. In the one patient with acute coronary occlusion the ROTACS was advanced over the guide wire to allow passage of an angioplasty balloon where this had previously proved impossible. An excellent final result was obtained and this patient remains symptom free. Three of the six patients in whom the ROTACS was unsuccessful had coronary artery dissection without sequelae. Three patients required subsequent elective coronary bypass grafting for control of symptoms while the other three remain well on medical treatment. CONCLUSIONS: The ROTACS may extend the range of patients with coronary artery occlusion or critical stenosis who can be treated non-surgically. The low device specific success rate (20%) achieved in this study indicates that it should be compared with other simpler mechanical devices that may be just as effective.

Angina Pectoris↗

Multivariate analysis to simplify the differential diagnosis of broad complex tachycardia.

Univariate analysis has identified several criteria that aid the differential diagnosis of broad complex tachycardia. In this study of 102 consecutive patients multivariate analysis was performed to identify which of 15 clinical and 11 electrocardiographic variables were independent predictors of ventricular tachycardia. These were shown to be a history of myocardial infarction, the QRS waveforms in leads aVF and V1, and a change in axis from sinus rhythm to tachycardia of more than 40 degrees. If none of the criteria was met, the diagnosis was almost certainly supraventricular tachycardia. If one criterion was met the diagnosis was probably supraventricular tachycardia. If two criteria were met then the diagnosis was probably ventricular tachycardia. If three or four criteria were met, the diagnosis was almost certainly ventricular tachycardia. The predictive accuracy was 93%. This was increased to 95% by including two other criteria--definite independent P wave activity and ventricular extrasystoles with the same QRS configuration as that in tachycardia. These criteria were not included in the multivariate analysis because though they were 100% specific they were seldom seen. These four criteria can be used as simple rules in determining the origin of a broad complex tachycardia.

Diagnosis, Differential↗

Dynamics of ventricular repolarisation in the congenital long QT syndromes.

Patients with congenital QT interval prolongation are at risk of ventricular arrhythmias and sudden death. It has been suggested that the susceptibility to arrhythmias in these syndromes may be related to the abnormal dynamics of ventricular repolarisation. The dynamics of ventricular repolarisation, including assessment of the effect of changing heart rate on the QT interval and the duration of the right ventricular monophasic action potential, were studied in eight patients with congenital long QT syndromes. The effects of altered sympathetic tone on these dynamics were investigated with isoprenaline, propranolol, and left stellate ganglion block. The rate adaptation of the QT interval was abnormal in only a few patients and in some patients this feature may be related to the severity of the condition. These abnormalities may be exaggerated by isoprenaline and lessened by propranolol and left stellate ganglion block. Monophasic action potential dynamics were normal in all patients. The hypothesis that impaired QT rate adaptation may play a role in the genesis of ventricular arrhythmias in these syndromes is not, in general, supported by the present data. However, in patients with impaired adaptation the normalisation of QT dynamics after beta blockade and left stellate ganglion block was consistent with the efficacy of these forms of treatment.

Action Potentials↗

Effects of intravenous adenosine on antegrade refractoriness of accessory atrioventricular connections.

BACKGROUND: Several groups have suggested the use of intravenous adenosine or adenosine triphosphate in the diagnosis of regular broad complex tachycardias. However, the short half-life of these agents has precluded assessment of their effects on refractoriness of accessory connections, and their safety in preexcited arrhythmias has not been demonstrated. METHODS AND RESULTS: We examined the effects of intravenous adenosine on accessory atrioventricular (AV) connections in 30 patients with the Wolff-Parkinson-White syndrome. Intravenous adenosine (12 mg, rapid bolus) was administered to 14 patients (group 1) during continuous atrial pacing at a cycle length 20 msec below that required to cause 2:1 conduction block in the accessory connection (mean pacing cycle length 261 +/- 41 msec). After adenosine, transient 1:1 conduction occurred via the accessory connection in 12 of 14 patients, indicating a shortening of antegrade refractoriness. In three of seven patients, this effect was abolished after intravenous propranolol (0.2 mg/kg). Nineteen patients (group 2) received adenosine (0.17 +/- 0.04 mg/kg) during induced, preexcited atrial arrhythmias. The minimum RR interval during preexcited atrial fibrillation transiently decreased (252 +/- 44 msec to 224 +/- 35 msec, p less than 0.01) after adenosine, but no change in average RR interval was observed (360 +/- 59 msec to 357 +/- 60 msec, NS). The preexcited ventricular response to atrial flutter was transiently accelerated in five of eight patients (415 +/- 21 msec to 360 +/- 49 msec, p less than 0.05) due to shortening of flutter cycle length (207 +/- 10 msec to 180 +/- 24 msec, p less than 0.05). However, 2:1 accessory connection conduction was maintained in all eight patients. All effects were short lived, with the decrease in RR interval during atrial fibrillation occurring for a maximum of two RR intervals only. No patient suffered ventricular arrhythmias or hemodynamic deterioration. CONCLUSIONS: Adenosine shortens antegrade refractoriness of accessory AV connections, and in some patients this action is mediated by beta-adrenergic stimulation. Adenosine may cause acceleration of preexcited atrial arrhythmias, but these effects are transient and should not discourage the use of adenosine as a diagnostic agent in broad complex, regular tachycardias of uncertain origin.

Adenosine↗

Relative efficacy and safety of intravenous drugs for termination of sustained ventricular tachycardia.

The relative safety and efficacy of intravenous administration of adenosine, lignocaine, disopyramide, flecainide, and sotalol for termination of stable, induced ventricular tachycardia was assessed in serial trials. Ventricular tachycardia was terminated by pacing if it persisted 10-15 min after the end of drug administration. 24 patients with recurrent ventricular tachycardia were studied. Ventricular tachycardia was terminated by a drug in 35 of 105 trials. In 6 patients no drug terminated the arrhythmia. Adenosine did not terminate tachycardia or have any serious adverse effect in any patient; both flecainide and disopyramide were significantly more effective than lignocaine, but flecainide had significantly more severe adverse effects than lignocaine. Lignocaine was the safest drug and should continue to be used as first-line drug therapy for stable ventricular tachycardia. Disopyramide should be considered as second-line treatment. DC cardioversion is necessary for unstable ventricular tachycardia, and its availability must be ensured before attempted pharmacological intervention.

Adenosine↗

Use of intravenous adenosine in sinus rhythm as a diagnostic test for latent preexcitation.

In a proportion of patients with left free wall accessory connections, preexcitation is apparent only during atrial arrhythmias or atrial pacing (latent preexcitation). These patients may be at risk of a rapid ventricular response to atrial fibrillation despite the absence of preexcitation in sinus rhythm. The ability of intravenous adenosine to unmask latent preexcitation was evaluated in 22 patients with a history of documented supraventricular tachycardia and a normal electrocardiogram during sinus rhythm. Preexcitation was unmasked in response to adenosine in 4 patients: all 4 were shown to have latent preexcitation at electrophysiologic study. In 12 patients atrioventricular (AV) nodal conduction delay or block was induced without preexcitation after adenosine (first-degree AV block in 8, second-degree block in 4): at subsequent electrophysiologic study none of these patients was found to have latent preexcitation. Five patients had little or no PR prolongation in response to adenosine: of these, 2 were shown to have latent preexcitation at electrophysiologic study. Atrial fibrillation was induced in 1 patient and a narrow complex regular tachycardia in another after intravenous adenosine. Intravenous adenosine during sinus rhythm is capable of producing AV nodal conduction delay or block in 73% of patients with a history of supraventricular tachycardia: in these patients adenosine provides a diagnostic test that is both 100% sensitive and 100% specific for latent preexcitation. In those patients in whom adenosine does not produce AV conduction delay or block, further investigation is required to establish or refute the diagnosis of latent preexcitation.

Adenosine↗

Signal-averaged electrocardiography in hypertrophic cardiomyopathy.

A major goal in the management of patients with hypertrophic cardiomyopathy is the prediction of sudden death. To evaluate the high gain signal-averaged electrocardiogram (ECG) in this setting, 64 patients with hypertrophic cardiomyopathy and 50 age- and gender-matched control subjects were studied. An abnormal signal-averaged ECG was more common in patients than in control subjects: 13 (20%) of 64 patients with hypertrophic cardiomyopathy had abnormalities compared with 2 (4%) of the 50 control subjects (p less than 0.001). There was a significant association between the presence of nonsustained ventricular tachycardia on 48 h ECG Holter monitoring and the presence of an abnormal signal-averaged ECG: 8 (47%) of the 17 patients with nonsustained ventricular tachycardia and 6 (86%) of 7 patients with more than three episodes of nonsustained ventricular tachycardia per 24 h had signal-averaged ECG abnormalities. There was no association between an abnormal signal-averaged ECG and a family history of premature sudden cardiac death, a history of syncope, symptomatic status, maximal left ventricular wall thickness, the presence of systolic anterior motion of the mitral valve or maximal rate of oxygen uptake on exercise. However, of four patients with a history of cardiac arrest, three had an abnormal signal-averaged ECG. Sensitivity was 50%; specificity was 93% and positive predictive accuracy was 77% for the signal-averaged ECG in detecting patients with electrical instability (defined as a history of cardiac arrest or the presence of nonsustained ventricular tachycardia, or both).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Effect of activation sequence on ventricular refractoriness as determined by extrastimuli.

STUDY OBJECTIVE: The aim was to determine by the extrastimulus method the effect on the right and left ventricular effective refractory periods of moving the site of the pacing train away from the site of the extrastimulus. DESIGN: The ventricular effective refractory period was measured at the right and left ventricular apices using pacing trains at two heart rates, delivered to the ipsilateral ventricle, the contralateral ventricle, and the right atrium. SUBJECTS: Seven patients (six male), mean age 52 years (range 26-75 years), with either documented (six) or suspected (one) ventricular tachycardia were studied. Four had ischaemic heart disease and the remaining three had morphologically normal hearts. MEASUREMENTS AND MAIN RESULTS: The pacing train and extrastimulus delivered in the right ventricle produced the shortest effective refractory period at both heart rates: 220.8(SD 19) ms and 207.9(16) ms respectively. As the pacing train was moved to the right atrium, the effective refractory period lengthened to 246.4(22) ms and 219.3(20) ms at the two heart rates. There was further lengthening as the site of the pacing train was moved to the left ventricle, to 269.2(20) ms and 240.7(35) ms respectively. The same pattern was observed in the left ventricular effective refractory periods as the pacing train was moved from left ventricle to right ventricle and to right atrium. CONCLUSIONS: The ventricular effective refractory period lengthens as the site of the pacing train is moved away from the site of the extrastimulus. This may be explained by the effects of the distribution of the pacing energy within the myocardium and by intercellular electrotonic interactions. This has important clinical implications for the arrhythmogenic mechanisms of ventricular tachyarrhythmias.

Adult↗

Endocardial pacing in infants and children 15 kg or less in weight: medium-term follow-up.

Twenty-four children 15 kg or less in weight (range 2.8-15 kg) underwent implantation of a permanent pacemaker using the transvenous technique of lead placement. During a follow-up period of 2 months to 6 years 1 month (median 3 years 6 months) eight children suffered complications, six of which necessitated reoperation. These included: lead fracture in two, infection in two, transient myocardial dysfunction in one, generator migration in one, premature battery depletion in one, and threshold rise in one. A loop of redundant ventricular lead positioned in the atrium at the time of implant is successfully unravelling in all children. One child died during the follow-up period of a pneumonia unrelated to her pacemaker. The other children are growing and developing normally and the cosmetic appearance has proved acceptable in all cases.

Body Weight↗

Atrioventricular Wenckebach point and progression to atrioventricular block in sinoatrial disease.

The value of measurement of the atrioventricular (AV) Wenckebach point at rest as a predictor of progression to AV block was investigated prospectively. Twenty-four patients with sinoatrial disease without evidence of conduction disturbance on 12-lead ECG or 24-hour ambulatory monitoring were paced with Medtronic Activitrax II, Medtronic Legend, or Telectronics Meta MV systems in AAI or AAIR modes. Patients were monitored for symptoms and evidence of AV block on 24-hour tapes. The mean age of the patients was 67 years (range: 42-88). There were 11 males and 13 females. The mean follow-up time was 10.7 +/- 5 months. Four patients required revision of pacing system as a result of development of AV block during follow-up. One other patient manifested intermittent second-degree AV block and remains in AAI. The AV Wenckebach points measured at 1 month postimplantation in the four patients who developed AV block requiring revision of system were 140, 125, 165, and 60 (mean 123 +/- 4). The mean AV Wenckebach point at first assessment in the remaining 20 patients was 153 +/- 24. The mean age of those requiring revision of system was 71 +/- 7 compared with 67 +/- 14 in those who did not. In this small series the frequency of development of significant AV block was 17%. This is markedly higher than in other recently reported series. The study demonstrates that an AV Wenckebach point above 120/min does not confer immunity from progression to AV block.

Adult↗

Major complications of coronary arteriography: the place of cardiac surgery.

The records of the catheter laboratory at St George's Hospital between 1983-1988 were reviewed to determine how often emergency coronary bypass surgery was performed because of a complication arising during elective coronary arteriography. A total of 11,216 cardiac procedures were performed; 5781 were confined to left ventricular angiography and coronary arteriography in patients with suspected coronary artery disease. Fourteen patients, whose investigation had been considered routine, suffered profound circulatory collapse during the procedure. Emergency cardiac surgery was undertaken in 13, with long term survival in 10. This experience suggests that, even in patients considered to be at low risk, there were major complications requiring emergency coronary surgery in at least 2.4 per 1000 coronary arteriograms performed. Survival after emergency cardiac surgery in these patients was 77%. These findings and the access to cardiac surgery should be considered when the development of facilities for cardiac catheterisation is planned.

Adult↗