Search PubMed⌕ Search

Biomedical subjects

D E Ward

Publications and source records attributed to D E Ward.

At least 55 records · Page 3Linked to original sources

Radiological appearances of implantable defibrillator systems.

Implantable defibrillator systems have been used in over 20,000 patients worldwide. Such systems use a variety of different electrodes and the identification of these and the recognition of associated problems with them presents a challenge to the radiologist. The appearance of currently available implantable defibrillation systems and the use of radiological examination in patient follow-up and system troubleshooting is discussed based on our experience with a large population of patients receiving these devices. Radiological examination is excellent for demonstrating displacement of distortion of defibrillation electrodes, but in our experience is ineffective for the identification of lead conductor fractures.

Defibrillators, Implantable↗

Radiofrequency catheter ablation of Mahaim tachycardia by targeting Mahaim potentials at the tricuspid annulus.

BACKGROUND: Reentrant tachycardias associated with Mahaim pathways are rare but potentially troublesome. Various electrophysiological substrates have been postulated and catheter ablation at several sites has been described. OBJECTIVE: To assess the efficacy and feasibility of targeting discrete Mahaim potentials recorded on the tricuspid annulus for the delivery of radiofrequency energy in the treatment of Mahaim tachycardia. PATIENTS: 21 patients out of a consecutive series of 579 patients referred to one of three tertiary centres for catheter ablation of accessory pathways causing tachycardia. All had symptoms and presented with tachycardia of left bundle branch block configuration or had this induced at electrophysiological study. In all cases, the tachycardia was antidromic with anterograde conduction over a Mahaim pathway. RESULTS: 6 patients had additional tachycardia substrates (4 had accessory atrioventricular connections and 2 had dual atrioventricular nodal pathways and atrioventricular nodal reentry). After ablation of the additional pathways, Mahaim potentials were identified in 16 (76%) associated with early activation of the distal right bundle branch and radiofrequency energy at this site on the tricuspid annulus abolished Mahaim conduction in all 16 cases. In 2 patients there was early ventricular activation at the annulus without a Mahaim potential but radiofrequency energy abolished pre-excitation. In the remaining patients no potential could be found (1 patient), no tachycardia could be induced after ablation of an additional pathway (1 patient), or no Mahaim conduction was evident during the study (1 patient). During follow up (1-29 months (median 9 months)) all but 1 patient remained symptom free without medication. CONCLUSIONS: Additional accessory pathways seem to be common in patients with Mahaim tachycardias. The identification of Mahaim potentials at the tricuspid annulus confirms that most of these pathways are in the right free wall and permits their successful ablation and the abolition of associated tachycardia.

Adolescent↗

Risk assessment related to veterinary biologicals: specific issues in developing nations.

The author reviews both technical and socio-economic issues in developing nations, in relation to veterinary biologicals. Health risk assessment is a specific process to estimate the likelihood that animals, humans or ecological systems will be affected adversely by a chemical or physical agent, or biological product, under a specific set of conditions. Some technical issues (quality assurance, good manufacturing practice, education of end-users, field monitoring) apply equally well in developed, industrialised and in developing, pre-industrialised nations. Many regions have documented unique diseases (trypanosomosis, tick diseases, theileriosis) or high disease prevalence which may influence risk assessment results. This emphasises the need for scientifically-valid risk assessment methodologies in developing nations. Developing nations also have various socio-economic concerns, which may not be based on scientific fact but, nonetheless, affect trade in, and use of, veterinary biologicals. These non-scientific but perceived problems and issues are briefly discussed, and possible solutions are presented. The way in which countries deal with such perceived problems and issues in a context of internationally harmonised norms for risk assessment impinges on livestock farmers in developing nations. Finally, the author presents possible ways to correct the potentially widening cost gap between conventional, proven veterinary biologicals and newly-developed products. The results of risk assessment of veterinary biologicals influence risk management in both developed and less-developed nations. It is important to agree upon scientifically-based risk management guidelines which may be applied in all countries. The effect of the agreements of the Uruguay Round of the General Agreement on Tariffs and Trade on trade in veterinary biologicals in developing nations is reviewed.

Animals↗

Localization of accessory pathways from the 12-lead electrocardiogram using a new algorithm.

A new algorithm (St. George's algorithm), based on the polarity and morphology of QRS complexes rather than delta waves, was developed for localizing accessory pathways to 1 of 9 sites on the atrioventricular annuli. This was compared with algorithms previously proposed by Skeberis et al (localizing to 1 of 7 sites) and Milstein et al (localizing to 1 of 4 sites). The preexcited 12-lead electrocardiograms recorded during sinus rhythm in 106 consecutive patients (including 60 retrospectively analyzed patients and 46 prospectively analyzed patients) who underwent successful radiofrequency catheter ablation of a single accessory pathway were analyzed by 3 blinded observers using all 3 algorithms. The results were compared with the actual localization of accessory pathways as derived from endocardial mapping during catheter ablation. In all 106 patients, the accuracy of the 3 algorithms for 4 sites on the atrioventricular annuli (as considered by Milstein's method) was 72%, 79%, and 92% for Milstein's, Skeberis', and St. George's algorithms, respectively. For 7 sites (as considered by Skeberis' method), the accuracy was 65% (Skeberis' algorithm) and 88% (St. George's algorithm), and for 9 sites (as considered by our method) the accuracy was 86% (St. George's algorithm). In 46 prospectively analyzed patients, the accuracy of the 3 algorithms for 4 sites was 70% (Milstein's), 67% (Skeberis'), and 87% (St. George's); for 7 sites the accuracy was 61% (Skeberis') and 85% (St. George's), and for 9 sites the accuracy was 85% (St. George's). The reproducibility of St. George's and Skeberis' methods was better than that of Milstein's method.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Effects of intravenous adenosine on verapamil-sensitive "idiopathic" ventricular tachycardia.

The mechanism of ventricular tachycardia (VT) that occurs in the absence of structural heart disease ("idiopathic" VT) is unknown, but may involve triggered activity or reentry through calcium channel-mediated conduction pathways. It has been suggested that termination of VT by adenosine is specific to ventricular arrhythmias caused by cyclic adenosine monophosphate-mediated triggered activity. The effects of vagotonic maneuvers, and intravenous adenosine (up to 0.25 mg/kg in incremental doses) and verapamil (0.145 mg/kg) administered to 9 patients with "idiopathic" VT were studied during electrophysiologic study. Seven patients had inducible fascicular VT and 2 had incessant right ventricular outflow tract tachycardia. Vagal maneuvers did not have any effect on any VT. Adenosine interrupted both right ventricular outflow tract tachycardias for a period (2 to 15 seconds) that was dependent on the dose of adenosine, but had no effect on VT in any patient with fascicular VT. Verapamil produced stuttering termination of right ventricular outflow tract tachycardia with no preceding change in RR interval in patients with this arrhythmia. Administration of verapamil to patients with fascicular VT was followed by gradual slowing of the arrhythmia (cycle length increased from 397 +/- 45 to 506 +/- 86 ms; p < 0.01) in all 7 patients and by termination of VT in 6. In conclusion, the differential response of fascicular and right ventricular outflow tract tachycardias to both adenosine and verapamil suggests that: (1) These 2 forms of idiopathic VT have different mechanisms. (2) Fascicular VT is unlikely to be due to cyclic adenosine monophosphate-mediated triggered activity.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine↗

Ventricular tachycardias of right ventricular origin: markers of subclinical right ventricular disease.

The diagnosis of subclinical myocardial disease in patients with ventricular tachycardias of right ventricular (RV) origin and no overt cardiac abnormalities is important, inasmuch as the presence of RV cardiomyopathy or arrhythmogenic dysplasia can be associated with a poor prognosis. To this end the relative value of symptoms, ECG features of ventricular tachycardia, signal-averaged ECGs, and RV echocardiograms as compared with endomyocardial biopsy findings was prospectively evaluated. Twenty-seven patients with chronic ventricular tachycardias with a left bundle branch block-like morphology, presumed to be of RV origin, were studied. Clinical examination findings, 12-lead ECGs in sinus rhythm, radiographs of the chest, coronary angiograms, and left ventricular cineangiograms were normal in all patients. RV biopsies were abnormal in 11 patients (41%) with findings suggestive of RV dysplasia or cardiomyopathy. A multivariate analysis showed a significant correlation between an abnormal biopsy and sustained ventricular tachycardia (p < 0.05), tachycardia with a superior frontal plane axis (p < 0.001), an abnormal signal-averaged ECG (p < 0.05), and an abnormal RV echocardiogram (p < 0.001). An abnormal RV echocardiogram was both a sensitive (73%) and a specific (94%) indicator of an abnormal RV biopsy. Sustained tachycardia although sensitive (90%) had a low specificity (56%). In comparison, a superior frontal plane axis of ventricular tachycardia and an abnormal signal-averaged ECG were indicative of high specificity and low sensitivity for abnormal myocardial histologic findings.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Radiofrequency ablation of accessory pathways: implications of accumulated experience and time dedicated to procedures.

Previous reports on radiofrequency ablation of accessory pathways have shown that the experience of the operator is of crucial importance in reducing fluoroscopy time and achieving higher success rates. However, a detailed analysis of this important issue has not been previously attempted. We analysed 71 consecutive ablation procedures undertaken at St George's Hospital by the same electrophysiology group and always with the same first operator. Of all procedures, 66 (91.6%) were successful, as judged by abolition of accessory pathway conduction without recurrence within the next 24 h. Failures included two out of 38 left-sided pathway procedures (5.3%), one out of 11 intermediate septal (9.1%) and four out of 22 right-sided pathway procedures (18.2%). These differences were not statistically significant. Average procedure and screening times for all procedures were 162.9 +/- 86.0 min and 56.8 +/- 48.2 min respectively, whereas the median of the number of discharges was 12, ranging from one to 51. There was no significant difference between pathway groups or between concealed and non-concealed pathways in respect to procedure and screening time or number of discharges. There was a significant tendency towards decreased procedure and screening times with accumulating experience and this was similar for all pathway groups. There was also a tendency towards improved cumulative success rates with time dedicated to procedures. We conclude that a certain amount of ablation experience is required, even by experienced electrophysiologists, before a relatively high success rate without long radiation exposure can be achieved, regardless of the location or the mode of conduction of the pathway.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

QT dispersion: problems of methodology and clinical significance.

QT dispersion is defined as the difference in QT interval between the different leads of the surface 12-lead ECG. This may provide an indirect measure of the underlying inhomogeneity of myocardial repolarization, which is believed to be important in arrhythmogenesis. Methodology for determining QT dispersion varies significantly between studies, and the results of these studies need to be interpreted in light of the methodology used. Although QT dispersion is developing into an important research tool, as yet it has no established role in clinical practice. Once standardization of methodology is achieved a clinical role may emerge, particularly in the assessment of patients before and after intervention aimed at reduction of arrhythmia risk.

Anti-Arrhythmia Agents↗

Exercise induced vasodepressor syncope.

Five cases of exercise induced pure vasodepressor syncope in patients without significant structural heart disease are reported. Hypotension and symptoms of syncope or pre-syncope were induced by treadmill exercise testing and in each case limited exercise performance. Evidence of inappropriate peripheral vasodilation, probably as a consequence of ventricular mechanoreceptor stimulation, was shown in all five patients. Head up tilt testing resulted in hypotension in four patients and isoprenaline infusion in the supine position resulted in hypotension in the fifth. These patients had a new condition of exercise induced neurally mediated (vasodepressor) syncope without appreciable structural cardiac abnormalities.

Adolescent↗

Radiofrequency catheter ablation of septal accessory atrioventricular pathways.

OBJECTIVE: Septal accessory atrioventricular pathways are recognised as being more difficult to ablate than pathways in other locations. This paper describes an experience of 48 consecutive patients with septal accessory pathways who had catheter ablation with radiofrequency current. PATIENTS AND METHODS: There were 28 male and 20 female patients, mean (SD) age 35 (17). 43 patients had a single accessory pathway and 5 patients had multiple accessory pathways. Pre-excitation was present in 37 patients, and 11 patients had concealed accessory pathways. 21 patients had had a previous electrophysiological study. Catheter ablation was undertaken with radiofrequency current delivered by a standard unipolar technique or by delivery of current across the septum (the bipolar technique). RESULTS: The median total procedure time was 167 (83) minutes including a 30-40 minute observation period after the abolition of conduction by the accessory pathway. The median total fluoroscopic time was 56 (30) minutes. 42 (88%) out of 48 patients had successful ablation of the pathway during the first session. In the six patients in whom the procedure failed, five had a midseptal pathway and one had a right anteroseptal pathway. A second attempt at ablation was made in two patients and succeeded in both. In total, 49 accessory pathways were successfully ablated in 44 (92%) out of 48 patients. The bipolar technique was used in 11 patients and succeeded in 10 patients. Standard unipolar current delivery had previously failed in seven of the 11 patients. Complications developed in two patients with a mid septal pathway (one with complete atrioventricular block and the other with a small pericardial effusion). CONCLUSION: Radiofrequency catheter ablation of septal accessory pathways is efficacious and safe. The procedure time can be shortened and success rate can be increased after improvement of the technique--that is, consideration of a bipolar approach for energy delivery in difficult cases.

Adolescent↗