A focal source for atrial fibrillation (AF) may be found in the first few centimeters of the pulmonary veins. Radiofrequency (RF) ablation may be directed at this source using activation mapping, but if the responsible atrial extrasystoles are infrequent or difficult to map, elimination of the source may require complete electrical isolation of the vein with multiple RF lesions. A new three-dimensional mapping system using a 64-pole basket catheter has been developed recently. We report the use of this system for ablation of focal AF in two patients. Mapping identified foci in the left and right superior pulmonary veins. Each focus was eliminated with a single RF ablation.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We developed a temperature-controlled radiofrequency (RF) system which can ablate by delivering energy to up to six 12.5 mm long coil electrodes simultaneously. Temperature feedback was obtained from temperature sensors placed at each end of coil electrodes, in diametrically opposite positions. The coil electrodes were connected in parallel, via a set of electronic switches, to a 150 W 500 kHz temperature-controlled RF generator. Temperatures measured at all user-selected coil electrodes were processed by a microcontroller which sent the maximum value to the temperature input of the generator. The generator adjusted the delivered power to regulate the temperature at its input within a 5 degrees C interval about a user-defined set point. The microcontroller also activated the corresponding electronic switches so that temperatures at all selected electrodes were controlled within a 5 degrees C interval with respect to each other. Physical aspects of tissue heating were first analysed using finite element models and current density measurements. Results from these analyses also constituted design input. The performance of this system was studied in vitro and in vivo. In vitro, at set temperatures of 70 degrees C, 85% of the lesions were contiguous. All lesions created at set temperatures of 80 and 90 degrees C were contiguous. The lesion length increased almost linearly with the number of electrodes. Power requirements to reach a set temperature were larger as more electrodes were driven by the generator. The system impedance decreased as more electrodes were connected in the ablation circuit and reached a low of 45.5 ohms with five coil electrodes in the circuit. In vivo, right atrial lesions were created in eight mongrel canines. The power needed to reach 70 degrees C set temperature varied between 15 and 114 W. The system impedance was 105+/-16 ohms, with one coil electrode in the circuit, and dropped to 75+/-12 ohms when two coil electrodes were simultaneously powered. The length and the width of the lesion set varied between 17.6+/-6.1 and 59.2+/-11.7 mm and 5.9+/-0.7 and 7.1+/-1.2 mm respectively. No sudden impedance rises occurred and 75% of the lesions were contiguous. From the set of contiguous lesions, 90% were potentially therapeutic as they were transmural and extended over the entire target region. The average total procedure and fluoroscopy times were 83.4 and 5.9 min respectively. We concluded that the system can safely perform long and contiguous lesions in canine right atria.
OBJECTIVE AND IMPORTANCE: We describe two patients with symptomatic septum pellucidum cysts managed by endoscopic fenestration. In each case, tissue from the cyst wall was studied to define the origin of the cyst wall and fluid. CLINICAL PRESENTATION: The patients, a 6-year-old boy and a 42-year-old man, each presented with headaches and a syncopal episode. Imaging studies demonstrated large septum pellucidum cysts with obstruction of the foramina of Monro. INTERVENTION: The patients underwent endoscopic transventricular cyst fenestration with a 4-mm steerable fiberscope. The fenestrations were created to allow communication with the right and left lateral ventricles. In one patient, adhesions between the cyst wall and the foramen of Monro were lysed with endoscopic monopolar cautery. Tissue from the cyst walls was removed for examination by electron microscopy. Postoperatively, the headaches and syncopal episodes resolved in both patients. CONCLUSION: Endoscopic fenestration of symptomatic septum pellucidum cysts produces immediate relief of the mass effect of the cyst and resolution of associated symptoms. Cannulation of the lateral ventricle before cyst fenestration prevents inadvertent injury to the fornices, thalamus, internal capsule, caudate nucleus, and septal and thalamostriate veins. The endoscopic approach allows the surgeon to ensure communication within the ventricular system, thus avoiding placement of a shunt. Preliminary ultrastructural analysis indicates that the cyst walls derive from the septum pellucidum rather than the choroid plexus or arachnoid. The cellular machinery necessary for fluid secretion was identified in some specimens.
INTRODUCTION: Linear atrial ablations are thought to be necessary to accomplish successful catheter ablation of atrial fibrillation. In order to investigate the conduction characteristics of atrial myocardium in regions of linear lesion discontinuity (gaps), we performed activation sequence mapping in gap regions during atrial pacing and atrial fibrillation. METHODS AND RESULTS: In seven dogs, a linear epicardial ablation was created on the right atrial free wall with a discontinuous segment (gap) in the mid-portion of the lesion. A plaque electrode was used to measure conduction across the gap. Conduction was assessed during (1) atrial pacing from the edge of the plaque electrode during sinus rhythm, and (2) during atrial fibrillation. After each series of measurements, the lesion gap was decreased by creating additional radiofrequency ablations and repeat conduction maps were obtained. The process was repeated until conduction block was observed during atrial pacing. Gap lengths ranged from 0 to 25 mm. During atrial pacing, gaps as narrow as 2 mm demonstrated normal conduction and gaps as large as 5 mm demonstrated block during pacing. Although conduction block was never present across gaps greater than 5 mm, the ability to predict conduction block as a function of gap width was difficult for lesions < or = 5 mm due to a significant degree of overlap between normal conduction and conduction block in this gap range. During atrial fibrillation, 1/175 (0.6%) mapped wavelets conducted across gaps that demonstrated block during pacing; whereas, 411/600 (68.5%; P < 0.0001) wavelets conducted across gaps that did not demonstrate block during pacing (P = NS compared to preablation measurements). Histologically normal atrial myocytes were observed within gaps exhibiting conduction block. CONCLUSIONS: Visible gaps > 5 mm rarely demonstrate conduction block during atrial pacing and atrial fibrillation; whereas, gaps < or = 5 mm in length may demonstrate block. Lesion gaps that do not demonstrate conduction block during atrial pacing have no higher rate of functional conduction block during atrial fibrillation than fibrillating atria without ablation lesions.
BACKGROUND: Recently, attempts have been made to cure atrial fibrillation by creating multiple linear atrial lesions with radiofrequency energy. Intracardiac echocardiography (ICE) offers imaging of endocardial anatomy and the ablation electrode-tissue interface not available with standard fluoroscopy. This study sought to prospectively compare fluoroscopic with ICE guidance for the creation of linear atrial lesions in a canine model. METHODS AND RESULTS: The creation of 3 linear atrial lesions was attempted in each of 10 dogs, half guided by fluoroscopy alone and half by ICE. Coil-tissue contact was prospectively graded. After ablation, animals were euthanized, and the location and continuity of lesions were evaluated. ICE guidance led to a higher percentage of successful applications (P=0.02) and mean achieved temperature (P=0. 004). The contact scores of excellent, fair, and poor correlated well with successful energy delivery, mean temperature, and efficiency of heating (P<0.0001). In 25% of the blinded energy deliveries, the location, as determined by the ablation operator, differed from that of ICE. Pathological evaluation revealed improved lesion formation in the ICE-guided compared with the ICE-blinded group. Lesions were found outside the target areas in the ICE-blinded but not the ICE-guided group. CONCLUSIONS: Compared with fluoroscopy, ICE guidance improved targeting, energy delivery, and lesion formation in this canine model. This study suggests that ICE guidance improves lesion formation and prevents energy delivery to potentially dangerous sites.
BACKGROUND: To test the hypothesis that susceptibility to sustained atrial fibrillation may be decreased by creation of linear atrial ablations, we established a canine model of chronic atrial fibrillation and used a novel catheter design to create atrial ablations. METHODS AND RESULTS: Chronic atrial fibrillation was induced in 16 dogs by creation of mitral regurgitation and rapid pacing of the atria. Temperature-controlled radiofrequency ablations were attempted along empirically derived, preselected atrial target sites in 11 dogs (ablation group), and a sham procedure was performed in 5 dogs (control group). Follow-up electrophysiology study and pathological examination were conducted 13+/-5 days after the initial procedure. Immediately after ablation, sustained atrial fibrillation could be initiated in 1 of 9 surviving ablation dogs and 5 of 5 controls (P=.004). Four dogs died within 24 hours of the procedure. Permanent pacing was required in 4 dogs. At follow-up, 0 of 7 ablation dogs and 5 of 5 controls had atrial fibrillation (P=.001). Furthermore, 2 of 7 ablation dogs had sustained atrial tachycardias, one of which was successfully ablated. Pathological examination demonstrated frequent incomplete lesion sets and discontinuous lesions. CONCLUSIONS: In this model, a reduction in the susceptibility to sustained atrial fibrillation can be achieved by long linear atrial ablations created with specially designed coil electrode catheters. Complete lesion continuity was not required to achieve a therapeutic effect.