Testing cholesterol accuracy. Performance of several common laboratory instruments.

The national emphasis on assessing coronary risk by cholesterol testing mandates that analytical determinations be as accurate and precise as is medically necessary. One goal of the National Cholesterol Education Program is to improve the quality of laboratory tests. Currently, 5% limits of imprecision and 5% of bias vs the nationally accepted Abell-Kendall reference method is recommended, with a goal of reducing these limits to 3% by 1992. Clinicians must be aware of how the cholesterol values are obtained, and especially whether the laboratory's method meets the performance goals. We assayed patients' serum samples for cholesterol using several commercially available, routinely used enzymatic methods and by the Abell-Kendall reference method. Precision of these methods was also assessed using serum-based controls. All instruments were operated precisely according to the manufacturers' instructions. Performance was objectively judged based on the National Cholesterol Education Program goals and on medically allowable total error. In all cases, the DuPont aca, the Kodak Ektachem, the Hitachi 737, and the Cobas FARA determined cholesterol levels acceptably. The precision and accuracy goals of 3% are achievable by these methods.

Adult↗

Complications of implanting three-piece C-loop posterior chamber lenses in the anterior chamber.

We have examined a total of four eyes in three patients who had undergone implantation of three-piece C-loop posterior chamber intraocular lenses into the anterior chamber. All four eyes exhibited four or more of the following complications: 1) loop encapsulation by peripheral anterior synechiae; 2) recurrent iritis; 3) central loop displacement with corneal endothelial touch; 4) progressive endothelial cell loss and corneal edema; 5) glaucoma; and 6) cystoid macular edema. Intraocular lens removal was required in all four eyes, and penetrating keratoplasty was performed in one. We believe that these complications are attributable to the inherent fallacies of fixating three-piece open-loop lenses in the anterior chamber angle.

Aged↗

Endophthalmitis following Nd:YAG laser posterior capsulotomy.

We report the development of Propionibacterium acnes endophthalmitis following Nd:YAG laser posterior capsulotomy. The patient previously underwent uncomplicated extracapsular cataract extraction with intraocular lens insertion and was free of inflammation prior to laser capsulotomy. Diagnostic vitrectomy and aqueous tap were performed, and P. acnes was isolated from the aqueous in thiol broth media after nine days of incubation under anaerobic conditions. The patient was managed with topical and systemic antibiotics and steroids. Complete resolution of inflammation with return of vision to 20/25 was achieved without removal of the intraocular lens or lenticular remnants.

Administration, Oral↗

The effect of scleral cautery on corneal astigmatism in cadaver eyes.

We studied the effect of scleral cautery on corneal astigmatism in 20 cadaver eyes using the Zeiss wetfield bipolar cautery either at or 2 mm posterior to the corneoscleral limbus. The chord of cauterized area was set at either 5.5 or 11 mm. Cautery induced net corneal steepening along the meridian of the cauterized area, and induced the greatest astigmatism when applied at the limbus. At each location the 11-mm cautery application induced less astigmatism. The majority of the astigmatic change occurred within the first 5 to 10 seconds of application. We found that scleral cautery at or 2 mm posterior to the limbus can induce extensive corneal astigmatism.

Astigmatism↗

Scleral flap surgery for modification of corneal astigmatism.

We performed resections and recessions of scleral flaps on human cadaver eyes in order to measure the induced change in keratometric astigmatism. We prepared 3-mm scleral flaps that were 3, 5, 7, or 10 mm long and resected or recessed these flaps up to 1 mm in 0.25-mm increments. Scleral flap resection resulted in up to 10.1 D of net corneal steepening along the meridian of the incision. Scleral flap recessions resulted in up to 7.7 D of net corneal flattening along the meridian of the incision; the effect increased with increasing flap length in the recessed eyes. There was a tendency toward mean corneal flattening with resections and mean corneal steepening with recessions.

Astigmatism↗

Concepts in the validation of neurochemical methods: the proper generation and use of statistics.

Nearly every advance made in the study of neurotransmission has resulted from the development of new analytical methods or from the application of such methods to neurochemical problems in new ways. Each investigator places extremely high dependence on the laboratory method from which the data are gathered. It is therefore vital that these methods be proven valid when first selected and when used throughout the experiments being conducted. The process of method validation has flourished and been refined in the field of laboratory medicine. Methods are primarily validated by their accuracy and reproducibility in determining the analyte of interest in the tissue(s) to be studied. It is important that standards of performance be established that will allow objective decisions to be made when methods are tested for these characteristics. Performance standards for several neurotransmitters are suggested. Studies performed to collect method performance data are presented. From these data, statistics can be generated that help to estimate analytical errors. Guidelines for the proper generation and use of these statistics are discussed. Use of these validation approaches should be expanded in the whole of neurochemistry, which should enrich the data gathered within a laboratory and improve the harmonization between laboratories.

Catecholamines↗

Effect of sample preparation and liquid chromatography column choice on selectivity and precision of plasma catecholamine determination.

Research into the role of the catecholamines has often depended on the reliable determination of plasma catecholamine concentrations, which present a challenge since they are normally in the low pg/ml range. Most methods employ liquid chromatography, with variations in sample preparation, the separation mechanism, and detection. We tested a new approach to sample clean-up using boric acid gel instead of alumina. No advantage was found. We also compared cation-exchange separation with ion-pair chromatography. Several improvements are possible with the former, most notably greater precision, better specificity, and increased throughput.

Aluminum Oxide↗

Secondary intraocular lens implantation.

We conducted a retrospective study of our first 75 consecutive patients receiving secondary intraocular lens implants. Ninety-seven percent had postoperative visual acuities of greater than or equal to 20/40; 86%, greater than or equal to 20/25. Four percent of patients lost two or more lines of vision. Complications included retinal detachment (4%), transient cystoid macular edema (3%), transient corneal edema (3%), pupillary block glaucoma (1%), and progression of an epiretinal membrane (1%). Patients requiring anterior vitrectomy had the least favorable outcome, with a 28% incidence of retinal complications. Overall, these data show secondary intraocular lens implantations to be safe and effective. However, greater caution is recommended for patients who will require anterior vitrectomy because of the higher rate of retinal complications.

Adult↗

Glare following posterior chamber intraocular lens implantation.

We performed glare tests on patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens implantation and on noncataractous phakic patients. Three types of lenses were implanted to compare the effect of optic asphericity and ultraviolet filtration on glare. Glare testing was performed using the Miller-Nadler Glare Tester and Baylor Visual Function Tester. The glare scores of the pseudophakic and phakic patients were statistically similar. In the pseudophakic patients, factors associated with decreased glare performance were posterior capsular opacification and increased pupil size; the intraocular lens type did not significantly affect glare scores.

Cataract Extraction↗

Persistent elevation in intraocular pressure after Nd:YAG laser treatment.

A bilaterally pseudophakic patient, who had no previous evidence of glaucoma, underwent Nd:YAG laser posterior capsulotomy and dispersal of vitreous syneresis opacities of his left eye. The eye developed persistent intraocular pressure elevation and visual field loss, requiring medical therapy and argon laser trabeculoplasty. His fellow eye remained normotensive after Nd:YAG laser posterior capsulotomy. Nd:YAG laser treatment can result in chronic intraocular pressure elevation and glaucomatous visual field loss.

Cataract Extraction↗

An evaluation of the Du Pont aca IV: does it meet medical needs?

A new bench-top analyzer from Du Pont, the "aca IV," was evaluated. To do so, we performed 10 different tests during an eight-week test period. The instrument is very precise (CVs less than 2%), results agree well with those obtained with the older acas (II and III), linearity is good in the clinically important ranges, and there is very little drift or carryover. From a medical-needs viewpoint, we found the analyzer satisfactory for all tests except possibly for calcium, for which the medical-needs criteria are so strict that few laboratories can meet them. We reached the latter conclusions by using a statistical model, described here, and from the predictive value of an abnormal test for populations with various prevalences of disease.

Autoanalysis↗

Flexible anterior chamber intraocular lens expulsion.

We report a case of presumed traumatic expulsion of an anterior chamber intraocular lens two weeks postoperatively. The 59-year-old patient presented complaining of foreign-body sensation; we found the intraocular lens in his superior conjunctival fornix.

Anterior Chamber↗

Determination of urinary 3-methoxy-4-hydroxyphenylglycol by liquid chromatography with electrochemical detection.

The increasing popularity of urinary 3-methoxy-4-hydroxyphenylglycol (MHPG) determinations has placed a demand on clinical laboratories to provide these data. Previous methods for MHPG either exhibit unacceptable performance, are too slow, or utilize instrumentation not commonly employed in these laboratories. The liquid chromatography electrochemical detection method described here has several positive features. MHPG is isolated by extraction, separated by liquid chromatography, and quantitated at an amperometric electrode. The precision, simplicity, and relatively low cost makes this new method an ideal choice for the clinical laboratory.

Chromatography, Liquid↗