Functional improvement after phacoemulsification cataract surgery.

PURPOSE: To evaluate subjective functional visual improvement after phacoemulsification and intraocular lens (IOL) implantation and identify patient characteristics and treatment features associated with no functional improvement. SETTING: Academic referral practice, Cullen Eye Institute, Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA. METHODS: A retrospective review was performed of the surgical results in 106 consecutive eyes of 102 patients who completed the American Society of Cataract and Refractive Surgery (ASCRS) Cataract Data Collection Form preoperatively and 1 month postoperatively. One surgeon performed all the surgery. The relationship of patient characteristics and treatment features and reported visual function was analyzed using an analysis of variance and the Wilcoxon rank sum and Fisher exact tests. RESULTS: One month postoperatively, all patients demonstrated improved visual acuity. However, 15 patients (14%) reported unimproved or decreased visual function. No statistically significant intergroup difference (P > .05) was detected in mean preoperative, postoperative, and fellow eye best spectacle-corrected visual acuities or refractive errors; reported severity of preoperative symptoms or satisfaction with vision; reported preoperative daily activity functioning or prevalence of hypertension and diabetes; type of anesthesia, lens material, or wound closure used; intraoperative or postoperative complication rates. However, patients reporting unimproved vision tended to be older and less satisfied with their quality of life and medical care than those reporting improved vision (P = .02, .03, .01, respectively). CONCLUSIONS: Self-reported visual function generally improved after phacoemulsification and IOL implantation; however, some older patients less satisfied with their quality of life and medical care reported no functional improvement despite improved visual acuity. These patients might benefit from an extended preoperative discussion of postoperative expectations.

Activities of Daily Living↗

Ocular biocompatibility testing of intraocular lenses: a 1 year study in pseudophakic rabbit eyes.

PURPOSE: To evaluate the appropriate duration for conducting ocular biocompatibility studies with an intraocular lens (IOL) in the pseudophakic rabbit model. SETTING: Alcon Laboratories, Inc., Fort Worth, Texas, USA. METHODS: A single-piece biconvex poly(methyl methacrylate) (PMMA) IOL was implanted in the capsular bag of 18 eyes of New Zealand white rabbits; 8 eyes received sham surgeries. Rabbits were monitored clinically and then sacrificed 6 or 12 months after surgery for histopathological examination of ocular tissues. RESULTS: Biomicroscopic examination revealed mild ocular changes in all surgical eyes during the first 3 months postoperatively. After that, there was a high incidence of posterior synechias, flare, and posterior capsule opacification (PCO) in eyes with PMMA IOLs. Posterior synechias and flare scores remained mild to moderate throughout the study, whereas PCO severity increased over time. Similar findings were observed in sham eyes. In addition, several eyes with PMMA IOLs developed IOL dislocation, hyphema, iris bombe, and a fibrous membrane covering the IOL. No discernible differences in biomicroscopic scores were observed in eyes at 6 or 12 months. Intraocular pressures and morphology of the corneal endothelium were normal in both groups. Results from histopathological analysis of the ocular tissues were consistent with observations from the biomicroscopic examinations. CONCLUSION: The results suggest that IOL implantation studies in the pseudophakic rabbit eye should be conducted for 3 or fewer months. Regulatory guidelines requiring longer ocular implantation studies should be revised to reflect the inherently rapid and extensive ocular response in the rabbit model.

Animals↗

Pediatric cataracts.

There have been major changes over the past 5 to 10 years in our understanding of both the chemical basis for and the surgical treatment of cataract in infants and children. Important questions that remain to be answered include the appropriate power and design selection criteria for intraocular lens implantation, as well as management of the posterior capsule and long-term refractive sequelae. In the past 10 years, there have been radical changes in the management of visually significant cataract in the infant and child. Whereas lens removal, subtotal posterior capsulectomy, vitrectomy, and aphakia were once the standard of care, many physicians now feel that small incisions, phacoemulsification technology, and intraocular lenses (IOLs) are best for these patients. Work is continuing to accumulate a significant body of evidence to evaluate results of these changes in technique and to develop optimal IOL designs and selection criteria for these specialized cataract patients.

Adolescent↗

Corneal topographic changes induced by excision of perilimbal lesions.

BACKGROUND AND OBJECTIVES: To evaluate corneal topographic changes induced by excision of two pterygia and a perilimbal dermoid. MATERIAL AND METHODS: Using the EyeSys Corneal Analysis System, we retrospectively analyzed the changes in astigmatism, mean central corneal power, and other topographic parameters of three corneas before and after surgical removal of two pterygia and a perilimbal dermoid. RESULTS: Marked corneal steepening occurred along the preoperative flat meridian after the excision of the pterygia and dermoid cyst. For each patient, surgery increased the mean central corneal curvature and decreased total astigmatism. CONCLUSION: Surgical excision can ameliorate abnormal corneal topographic changes produced by limbal lesions.

Adult↗

Experimental and clinical evaluation of incision size and shape following forceps and injector implantation of a three-piece high-refractive-index silicone intraocular lens.

BACKGROUND: Previous studies have demonstrated that incision sizes required for insertion of various foldable intraocular lenses (IOLs) vary according to the IOL/inserter combination. The purpose of this study was to compare incision sizes and wound shape for both forceps and injector implantation of high-refractive-index silicone IOLs. METHODS: In fresh human cadaver eyes, limbal corneal tunnel incisions were created, and 12 foldable high-refractive-index silicone (dimethyldiphenylsiloxane) IOLs were inserted in a randomized fashion using either a forceps or an injector. Using incision calipers, internal and external measurements of the tunnel incisions were obtained before and after IOL insertion. Scanning electron microscopy (SEM) was performed on selected corneas following IOL insertion. Additionally, in 12 cataract procedures, the incision sizes following forceps or injector implantation were evaluated intraoperatively. RESULTS: In the experimental setting, the external and internal tunnel widths (in mm) before insertion were 3.05 mm (+/-0.07) and 3.02 mm (+/-0.03), respectively, with the forceps and 3.06 mm (+/-0.04) and 3.01 mm (+/-0.04) with the injector. Following IOL implantation, the external and internal incision sizes were 3.33 mm (+/-0.07) and 3.33 mm (+/-0.04) with the forceps and 3.32 mm (+/-0.08) and 3.33 mm (+/-0.07) with the injector. SEM showed tearing of corneal structures after implantation through the smallest possible incisions with both devices. In the clinical study, the incision sizes before and after implantation were 3.23 mm (+/-0.10) and 3.36 mm (+/-0.06) with the forceps and 3.11 mm (+/-0.08) and 3.21 mm (+/-0.10) with the injector. CONCLUSIONS: This study confirms that high-refractive-index silicone IOLs provide one of the smallest currently achievable incisions before and after IOL implantation. In clinical use, the new injector reduces the mean incision size required by approximately 0.1 mm.

Aged↗

Axial, instantaneous, and refractive formulas in computerized videokeratography of normal corneas.

PURPOSE: To compare the values for corneal power determined by the axial, instantaneous and refractive formulas when imaging normal human corneas using computerized videokeratography. SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. METHODS: This prospective clinical trial involved 60 corneas of 30 normal volunteers. Computerized videokeratography was performed to determine corneal power at the center and the 1, 3, 5, and 7 mm zones using the 3 formulas. RESULTS: Mean central corneal power was 42.86 diopters (D) with each of the formulas. The mean corneal powers for the axial, instantaneous, and refractive formulas were 43.09, 43.21, and 42.98 D at the 1 mm zone; 43.10, 42.92, and 43.46 D at the 3 mm zone; 42.75, 41.63, and 44.02 at the 5 mm zone; 42.21, 40.30, and 44.79 D at the 7 mm zone, respectively. The differences among powers for the 3 formulas at the 3, 5, and 7 mm zones were statistically significant (P < .01). CONCLUSION: In normal corneas, clinically significant differences exist in the corneal power values calculated by the axial, instantaneous, and refractive formulas.

Adolescent↗

Radial and staggered treatment patterns to correct hyperopia using noncontact holmium:YAG laser thermal keratoplasty.

PURPOSE: To compare the effects of two treatment patterns in the correction of hyperopia by noncontact holmium:YAG laser thermal keratoplasty (LTK). SETTING: Divisione Oculistica, Ospedale S. Gerardo, Monza, Italy. METHODS: Using two treatment patterns, we performed noncontact LTK in one session in 16 eyes of 8 patients with isometropic hyperopic refractive errors; mean preoperative subjective cycloplegic refraction was +4.90 diopters (D) +/- 1.17 (SD). The treatment consisted of 24 spots in three concentric rings of eight spots each; ring diameters were 6.0, 7.0, and 8.0 mm, respectively. Each spot received seven pulses of laser energy at 30 mJ/pulse. We treated one eye of each patient with a radial pattern (the spots of the three rings aligned on the eight semimeridians) and the fellow eye with a staggered pattern (the spots of the contiguous rings at 22.5 degrees from each other). Follow-up at 1, 15, 30, 90, 180, and 360 days included subjective cycloplegic refraction, uncorrected (UCVA) and spectacle-corrected visual acuity (SCVA), computerized videokeratography (CVK), and Scheimpflug camera examination. RESULTS: One year postoperatively, the mean subjective cycloplegic refraction was +2.75 +/- 1.6 D in the eyes treated with the radial pattern and +3.40 +/- 1.6 D in those treated with the staggered pattern; the mean change in subjective cycloplegic refraction was 2.15 and 1.50 D, respectively. Mean UCVA improved by five lines in the radial group and by four lines in the staggered group. Mean SCVA returned to preoperative levels by day 15 in the radial group and at 1 year in the staggered group; at 1 year, SCVA improved by one line in the radial group and remained unchanged in the staggered group. No eye lost one or more lines of SCVA. Refractive astigmatism was essentially unchanged in both groups. Scheimpflug photography and CVK indicated larger and more uniform corrected zones in the radial group. CONCLUSIONS: Radial and staggered patterns effectively corrected low hyperopia, although both were subject to a certain amount of regression. The radial pattern produced faster postoperative recovery of SCVA and demonstrated greater refractive stability.

Adult↗

Evaluating and reporting astigmatism for individual and aggregate data.

PURPOSE: To demonstrate the proper method for evaluating and reporting astigmatism for individual and aggregate data. SETTING: University of Texas Medical School and Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. METHODS: The surgically induced refractive change (SIRC) was determined for three data sets of patients who have had keratorefractive (photorefractive keratectomy) or cataract surgery. To make changes in refraction comparable, vertex distances for the refractions and keratometric index of refraction were considered. Doubledangle plots and single-angle plots were then used to display the data. Polar values (cylinder and axis) were converted to a Cartesian (x and y) coordinate system to determine the mean value of the induced astigmatism for each data set. RESULTS: Doubled-angle plots clearly demonstrated the trends of induced astigmatism for each data set, and the mean value for induced astigmatism agreed exactly with the intuitive appearance of the plot. CONCLUSIONS: Converting astigmatism data to a Cartesian coordinate system allowed the correct computation of descriptive statistics such as mean values, standard deviations, and correlation coefficients. Using doubled-angle plots to display the data provides the investigator with the best method of recognizing trends in the data.

Astigmatism↗

Peripheral radial incisions to treat inferior contact lens edge lift after penetrating keratoplasty for keratoconus.

A patient with marked corneal astigmatism and inferior contact edge lift after penetrating keratoplasty for keratoconus had corneal relaxing incisions (CRIs) on the donor button and radial incisions on the host cornea. Results were evaluated by computerized videokeratography and by refitting the contact lens. Two pairs of CRIs decreased astigmatism from 11.00 to 4.25 diopters but did not alleviate the contact lens edge lift, which was caused by excessive steepness in the keratoconic host cornea. After 6 radial incisions were made to flatten the inferior host cornea, the peripheral cornea flattened and the patient was successfully refitted with a contact lens.

Astigmatism↗

Effect of heparin in irrigating solution on inflammation following small incision cataract surgery.

PURPOSE: To study the effect of heparin-sodium added to the irrigating solution on postoperative inflammation in patients having cataract surgery. SETTING: Department of Ophthalmology, University of Giessen, Giessen, Germany. METHODS: Seventy-two patients having phacoemulsification with posterior chamber intraocular lens (IOL) implantation were randomly assigned to receive regular irrigating solution or solution with heparin-sodium (final diluted concentration 10 IU/mL). In half the patients, poly(methyl methacrylate) (PMMA) IOLs were implanted and in half, foldable silicone IOLs. The patients were examined preoperatively, on days 1 and 3, and 1 year postoperatively. Postoperative inflammation was objectively evaluated by measurement of flare and cells using laser flare-cell photometry. RESULTS: The mean postoperative flare values were significantly lower in the groups with additional heparin-sodium at days 1 and 3 (P < . 01). Flare values were not significantly different 1 year postoperatively. Cell values for the heparin-treated groups were lower, but the difference did not reach statistical significance. Flare and cells values for the two IOL materials were not significantly different during the entire follow-up. CONCLUSION: Heparin-sodium added to the infusion solution during small incision cataract surgery reduced inflammation in the early postoperative period.

Aged↗

Dehiscence of a radial keratotomy incision during clear corneal cataract surgery.

We report a case of dehiscence of a radial keratotomy (RK) incision caused by clear corneal cataract surgery. The patient had eight-incision RK in both eyes 9 months previously with enhancement surgery in the left eye 1 month later. Cataract surgery through a clear corneal incision was performed in the right eye and 1 month later, in the left. Surgery in the right eye was uneventful. However, during surgery in the left eye, dehiscence of one radial incision occurred. The wound dehiscence was closed with interrupted sutures, and the patient achieved 20/20, uncorrected visual acuity 1 week after surgery.

Cornea↗

Limbal relaxing incisions with cataract surgery.

PURPOSE: To evaluate the effectiveness of limbal relaxing incisions (LRIs) for correcting corneal astigmatism during cataract surgery. SETTING: Cullen Eye Institute, Houston, Texas, USA. METHODS: In 12 eyes of 11 patients, cataract surgery was combined with LRIs. The LRIs were made according to a modified Gills nomogram and were based on preoperative corneal astigmatism determined with standard keratometry and computerized videokeratography (EyeSys Corneal Analysis System Version 3.2). RESULTS: The mean preoperative keratometric cylinder was 2.46 +/- 0.81 diopters (D). At 1 month postoperatively, mean arithmetic reduction in keratometric cylinder was 1.12 +/- 0.74 D, and the with-the-wound (WTW) change (calculated by Holladay, Cravy, Koch vector analysis formula) was -0.70 +/- 0.44. From 1 day to 1 month postoperatively, there was 0.55 D of WTW regression with minimal change in the mean cylindrical axis. There were no overcorrections. CONCLUSION: Limbal relaxing incisions are a practical, simple, and forgiving approach to the correction of astigmatism during cataract surgery.

Adult↗

Wide variation in serum anion gap measurements by chemistry analyzers.

The traditional anion gap [AG = Na-Cl-(total CO2)] mean value of 12 mEq/L was established during the 1970s with analyzer methods that are no longer used widely. No studies have systematically compared mean AG values from analyzers in current use. We used data from healthy subjects obtained from 27 clinical laboratories, 5 manufacturers, and 8 publications to compute mean AG values from 1970s analyzers and 8 current analyzers. We also compared mean AG values by evaluating Na, Cl, and total CO2 data from the College of American Pathologists Chemistry Surveys (1990-1996). Data from healthy subjects showed that overall mean AG values of the 9 analyzers ranged from 5.9 to 12.4 mEq/L. The pooled (i.e., average) AG SD was 2.3 mEq/L. We then used the data of the Surveys and the mean value from 1 analyzer to compute predicted mean values for the other 7 current analyzers. Almost all mean AG values predicted from the Surveys agreed (within 1.5 mEq/L) with mean values from healthy subjects. These results show that mean values of analyzers vary widely, indicating that analytic bias strongly influences the AG. The results should be a useful guide for the AG measurements that can be expected from different analyzers.

Acid-Base Equilibrium↗

Pediatric cataracts.

Over the past year, major advances have occurred in our understanding of the surgical management of pediatric cataracts. New insights concerning the response of the pediatric eye to intraocular lens implantation coupled with improved surgical techniques are expanding the indications and reducing the complications of intraocular lens implantation in children. Additionally, new progress has been made in identifying the risk factors for the development of pediatric cataracts and the etiologies of associated complications.

Adolescent↗