Bioassay screening for toxicants in oil samples from the toxic-oil syndrome outbreak in Spain.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D D Bayse.
Explore the source record for details and available documents.
Standardization of lipid and lipoprotein measurements is of concern to laboratories that serve pediatric as well as adult populations, since preventive measures taken during pediatric years can help control atherosclerotic cardiovascular problems that can arise during adult years. Multiple analytical and physiologic problems that exist inherently in the lipids and lipoproteins and in application of measurements to the pediatric population must be controlled to gain standardization and produce highly precise and accurate results. Reference values from well-described, observed pediatric populations have been published for use in interpreting analytical results. In collaboration with NHLBI, the CDC has offered lipid and lipoprotein standardization services for the United States since 1957 and, on an international scale, has cooperated with WHO since 1962. Standardization activities have been primarily concerned with total and HDL cholesterol and triglyceride determinations for cardiovascular epidemiologic and clinical trial investigations.
Three fatalities from the accidental ingestion of methomyl, a carbamate pesticide, are reported. The methomyl had been stored in an unlabeled tin can and was accidentally used in preparing "roti," an Indian dish. The identification of the source of the poison through animal tests and further chemical identification is described. The lethal dose of methomyl was estimated to have been between 12 and 15 mg/kg body weight.
Eight different pools of purified human mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase were prepared, to examine the effects of the following matrix variables: the matrix support material (bovine serum albumin and polyvinylpyrrolidone), endogenous pyridoxal concentration, and azide as an antimicrobial preservation. Storage temperatures of 25 and 37 degrees C were used as a rapid and convenient means of accelerating the degradation process. Activity of the enzyme was measured with and without pyridoxal in the reaction solution. We found that the mitochondrial isoenzyme was consistently more labile than the cytoplasmic isoenzyme under identical storage conditions. Both isoenzymes were more stable in matrixes containing bovine serum albumin than in those containing polyvinylpyrrolidone. No apparent difference in the stability of either isoenzyme was observed at matrix pyridoxal concentrations of 15 micromol/L and 150 micromol/L. Only the mitochondrial isoenzyme in matrixes containing bovine serum albumin and 15 micromol of pyridoxal per liter had increased activity (about 9%) when pyridoxal was added to the enzymatic reagent. The amount of activity in reconstituted specimens did not apparently change after 72 h at 4 degrees C.
The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared and characterized and then distributed to 293 laboratories for aspartate aminotransferase measurements. The specimens included one human serum; four catalytic concentrations of the cytoplasmic isoenzyme, two purified from human erythrocytes, and two from porcine heart; and one matrix bovine serum albumin (30 g/liter) blank. The purified isoenzymes were prepared in the matrix. We present data on Michaelis parameters (Km and Vmax), Arrhenius plots, activation with pyridoxal 5-phosphate, vial-to-vial variability, and stability on reconstitution. The 281 responses showed that most of the laboratories used NADH-detection methods (91.1%), monitored at 340 nm (79.4%), and reported results in U/liter (89.4%). The percentage of laboratories reporting use of reaction temperatures of 30 and 37 degrees C was evenly divided, i.e., 42.7 and 42%, respectively. Analytical values reported by participating laboratories were categorized by reporting temperature, instrument, and method. Results were most consistent for a selected group of laboratories that supplemented optimized reaction solutions with pyridoxal 5-phosphate.
A gas chromatographic-electron capture detection method for determining the concentration of polychlorinated biphenyls (PCBs) as Aroclor 1254 (AR 1254) in serum was evaluated through a 2-phase collaborative study. In Phase I, each collaborator's lot of Woelm silica gel (70-150 mesh) was evaluated for elution and recovery of AR 1254, which had been added in vitro at 25 ng/mL to a serum extract. In Phase II, each collaborator analyzed a series of bovine serum samples that contained the following: (1) in vitro-spiked AR 1254; (2) in vivo AR 1254 and 8 in vitro-spiked chlorinated hydrocarbons; (3) in vivo AR 1254 only; (4) 8 in vitro-spiked chlorinated hydrocarbons only; and (5) neither AR 1254 nor chlorinated hydrocarbons above the detection limit of the method. In Phase I, the average recovery of AR 1254 from silica gel for the 6 collaborators was 87.9 +/- 15.44% (mean +/- 1 SD; N = 18; range = 52.3-105.8%). In Phase II, the analysis of in vitro spikes of AR 1254 in serum at 8.58, 16.8, 41.8, and 84.3 ppb gave mean (means) interlaboratory recoveries of 89.0, 83.3, 79.4, and 76.9%, respectively, with within-laboratory (repeatability) relative standard deviations (RSDr) of 18.8, 20.5, 10.2, and 14.1%, respectively, and among-laboratory (reproducibility) relative standard deviations (RSDR) of 21.5, 21.1, 14.6, and 20.8%, respectively. The determination of in vivo AR 1254 in samples containing approximately 10, 25, 50, and 100 ng/mL of AR 1254 resulted in interlaboratory means of 10, 22, 39, and 79 ng/mL, respectively, with RSDr = 6.7, 9.7, 6.4, and 5.8%, respectively, and RSDR = 20.6, 16.0, 10.9, and 10.3%, respectively. The precision of the method for incurred AR 1254 showed a maximum RSDr of less than 10% and a maximum RSDR of less than 21% for a concentration range of 10-100 ng/mL. The accuracy of the method as demonstrated by the mean recovery of in vitro-spiked AR 1254 over a concentration range of 8.58-843 ng/mL was 82.2%. The method has been approved interim official first action.
Explore the source record for details and available documents.