Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system.

Nimbus Inc. (Rancho Cordova, CA) and the University of Pittsburgh have completed the second year of development of a totally implanted axial flow blood pump under the National Institutes of Health Innovative Ventricular Assist System Program. The focus this year has been on completing pump hydraulic development and addressing the development of the other key system components. Having demonstrated satisfactory pump hydraulic and biocompatibility performance, pump development has focused on design features that improve pump manufacturability. A controller featuring full redundancy has been designed and is in the breadboard test phase. Initial printed circuit layout of this circuit has shown it to be appropriately sized at 5 x 6 cm to be compatible with implantation. A completely implantable system requires the use of a transcutaneous energy transformer system (TETS) and a diagnostic telemetry system. The TETS power circuitry has been redesigned incorporating an improved, more reliable operating topography. A telemetry circuit is undergoing characterization testing. Closed loop speed control algorithms are being tested in vitro and in vivo with good success. Eleven in vivo tests were conducted with durations from 1 to 195 days. Endurance pumps have passed the 6 month interval with minimal bearing wear. All aspects of the program continue to function under formal quality assurance.

Heart-Assist Devices↗

Chronic animal health assessment during axial ventricular assistance: importance of hemorheologic parameters.

Chronic testing of the Nimbus/UOP Axial Flow Pump was performed on 22 calves for periods of implantation ranging from 27 to 226 days (average, 74 days). The following parameters were measured: plasma free hemoglobin, blood and plasma viscosity, erythrocyte deformability and mechanical fragility, oxygen delivery index (ODI), blood cell counts, hematocrit, hemoglobin, blood urea nitrogen, creatinine, bilirubin, total protein, fibrinogen, and plasma osmolality. Most of the above parameters were stable during the full course of support. Compared with baseline, statistically significant differences during the entire period of implantation were only found in: hematocrit (p<0.001), hemoglobin (p<0.005), red blood cell (RBC) count (p<0.001), and whole blood viscosity (p<0.01). Plasma viscosity and ODI were mostly stable during the period of implantation. In some animals, an acute increase in fibrinogen concentration, plasma and blood viscosity, and a decrease in ODI were found to be early signs of the onset of infection. A small (10%) decrease in deformability of RBCs was found during the first 2 weeks after implantation. This alteration in RBC deformability was highly correlated (r = 0.793) with changes in total plasma protein concentration that fell more than 15% (p<0.001) during the same period. Mechanical fragility of RBCs was found to be slightly increased after implantation. Plasma free hemoglobin remained close to baseline level (p>0.2). After the first 2 weeks of the postoperative period, pump performing parameters for all animals were consistent and stable. In general, the Nimbus/UOP Axial Flow Pump demonstrated basic reliability and biocompatibility and did not produce significant alterations in the mechanical properties of blood or animal health status. The pump provided adequate hemodynamics and was well tolerated by the experimental animal for periods as long as 7.5 months. Monitoring rheologic parameters of blood is very helpful for evaluation of health during heart-assist device application.

Animals↗

Fluid dynamic characterization of operating conditions for continuous flow blood pumps.

As continuous flow pumps become more prominent as long-term ventricular assist devices, the wide range of conditions under which they must be operated has become evident. Designed to operate at a single, best-efficiency, operating point, continuous flow pumps are required to perform at off-design conditions quite frequently. The present study investigated the internal fluid dynamics within two representative rotary fluid pumps to characterize the quality of the flow field over a full range of operating conditions. A Nimbus/UoP axial flow blood pump and a small centrifugal pump were used as the study models. Full field visualization of flow features in the two pumps was conducted using a laser based fluorescent particle imaging technique. Experiments were performed under steady flow conditions. Flow patterns at inlet and outlet sections were visualized over a series of operating points. Flow features specific to each pump design were observed to exist under all operating conditions. At off-design conditions, an annular region of reverse flow was commonly observed within the inlet of the axial pump, while a small annulus of backflow in the inlet duct and a strong disturbed flow at the outlet tongue were observed for the centrifugal pump. These observations were correlated to a critical nondimensional flow coefficient. The creation of a "map" of flow behavior provides an additional, important criterion for determining favorable operating speed for rotary blood pumps. Many unfavorable flow features may be avoided by maintaining the flow coefficient above a characteristic critical coefficient for a particular pump, whereas the intrinsic deleterious flow features can only be minimized by design improvement. Broadening the operating range by raising the band between the critical flow coefficient and the designed flow coefficient, is also a worthy goal for design improvement.

Centrifugation↗

Continuing development of the Cleveland Clinic-Nimbus total artificial heart.

A completely implanted total artificial heart (TAH) is under development by Nimbus, Inc., and the Cleveland Clinic Foundation (CCF). Key features of the system include an electrohydraulic energy converter, an automatic control system that produces a Frank-Starling response, and dual ventricles composed of graphite-epoxy and titanium with gelatin blood contacting surfaces. The system is controlled by a single substrate, hybridized microcircuit (the hybrid). Fabrication of the TAH control hybrid has recently been completed and testing begun. Its design emphasizes simplicity, reliability, and efficiency. Particular attention was given to optimizing thermal management. Externally controlled TAH systems have been used in eight in vivo experiments of up to 120 days' duration. In the last two of these experiments, a variable volume device was also implanted with excellent results. In vivo use of the system has demonstrated the Frank-Starling pump response, but the systems quickly reach maximum output with the bovine animal models. Human fitting studies, including adult patients undergoing heart transplantation, demonstrated satisfactory fit of the pump within the pericardium without compression of the vascular structures or chest wall. Measurements of chest circumference, plain chest films, and transesophageal echocardiograms should provide reliable predictions of pump fit in the majority of patients.

Animals↗

In vivo evaluation of an extracorporeal pediatric centrifugal blood pump.

This paper summarizes the authors' in vivo experience in evaluating a miniature centrifugal blood pump designed for pediatric/neonatal ventricular support. Left ventricular bypass was accomplished in two adult sheep and five juvenile lambs (5.5-80.0 kg) via either central (left ventricle to carotid artery) or peripheral (jugular vein to carotid artery) cannulation. Animals were weaned from mechanical ventilation and continuously monitored. Hemodynamic parameters remained within a normal range over the duration of the bypass. Two of five lambs were electively killed at 8, and 76 hours; the remaining three lambs died from respiratory complications at 33, 44, and 156 hours. There were no mechanical complications, and blood seal integrity was confirmed beyond 6 days. The pump speed was maintained at 3,000-4,500 rpm with pump flow rates between 0.4-1.5 L/min. Average plasma free hemoglobin was below 20 mg/dl in the five lamb experiments. Renal, hepatic, and hematologic indices also remained within physiologic ranges. Histopathologic analyses of major organs revealed renal cortical infarctions in two of five lambs. Examination of the pump surfaces after explant indicated small areas of thrombus in the housing adjacent to the outflow ports in two experiments. These encouraging results support further testing and refinement of this miniature centrifugal pump.

Animals↗

Survival for up to six months in calves supported with an implantable axial flow ventricular assist device.

This paper summarizes the authors' in vivo experience to date with an implantable axial flow blood pump designed for long-term ventricular support. This small, valveless pump with blood-lubricated bearings has been implanted in six calves (83 +/- 6 kg) as a left ventricular assist device (LVAS). The left ventricle and descending thoracic aorta were cannulated by left thoracotomy, and the pump was placed in a subcutaneous pocket below the costal margin. Animals remained hemodynamically stable throughout the course of support during partial left ventricular bypass. Five animals were killed after 15, 27, 52, 57, and 181 days. The longest survivor (181 days) demonstrated normal pump function at the time death. Pump speed was maintained at 10,100 +/- 100 rpm, with an average pump flow rate of 4.9 +/- 0.5 L/min under resting physiologic conditions. Average plasma free hemoglobin was 17.4 +/- 7.5 mg/dl. Renal, hepatic, and hematologic indices remained within physiologic range in all of these animals, except during the immediate postoperative period. Histopathologic analyses of major organs after death revealed small renal cortical infarcts in five of six animals; the remaining organs were normal. These animal studies support the feasibility of this small implanted axial flow pump for long-term ventricular assistance.

Animals↗

Continued development of the Nimbus/University of Pittsburgh (UOP) axial flow left ventricular assist system.

Nimbus and the University of Pittsburgh (UOP) have continued the development of a totally implanted axial flow blood pump under the National Institutes of Health (NIH) Innovative Ventricular Assist System (IVAS) program. This 62 cc device has an overall length of 84 mm and an outer diameter of 34.5 mm. The inner diameter of the blood pump is 12 mm. It is being designed to be a totally implanted permanent device. A key achievement during the past year was the completion of the Model 2 pump design. Ten of these pumps have been fabricated and are being used to conduct in vitro and in vivo experiments to evaluate the performance of different materials and hydraulic components. Efforts for optimizing the closed loop speed control have continued using mathematical modeling, computer simulations, and in vitro and in vivo testing. New hydraulic blade designs have been tested using computational fluid dynamics (CFD) and flow visualization. A second generation motor was designed with improved efficiency. To support the new motor, a new motor controller fabricated as a surface mount PC board has been completed. The program is now operating under a formal QA system.

Animals↗