Search PubMed⌕ Search

Biomedical subjects

D C Shah

Publications and source records attributed to D C Shah.

At least 55 records · Page 3Linked to original sources

Successful radiofrequency ablation of a slow atrioventricular nodal pathway on the left posterior atrial septum.

RF catheter ablation is highly effective in eliminating atrioventricular nodal reentrant tachycardia by targeting the slow pathway in the posteroinferior part of Koch's triangle in the right atrium. We report here a patient in whom "slow-fast" atrioventricular nodal reentrant tachycardia was eliminated only by ablation of the slow pathway in the left atrial posteroseptal region at the level of the mitral annulus after unsuccessful attempts at the traditional site on the right side.

Adult↗

Pacemaker syndrome induced by the mode switching algorithm of a DDDR pacemaker.

A patient with marked first-degree AV block and a DDDR pacemaker presented with a history of paroxysmal narrow QRS tachycardia, subsequently identified as sinus tachycardia (with a very long PR interval), causing a clinical problem similar to pacemaker syndrome because of loss of AV synchrony. The latter resulted from an excessively long postventricular atrial refractory period (PVARP) that prevented sensing of sinus P waves. The unfavorable hemodynamics caused reflex sinus tachycardia. The long PVARP was mandated by the mode switching algorithm of this particular device and was automatically set according to the selected tachycardia detection rate. The patient became asymptomatic when the mode switching function was turned off and the PVARP shortened.

Algorithms↗

Local electrogram-based criteria of cavotricuspid isthmus block.

INTRODUCTION: The efficacy and outcome of cavotricuspid isthmus ablation guided by local electrogram-based criteria of linear block were prospectively assessed. METHODS AND RESULTS: In 40-consecutive patients (age 65+/-11 years) with typical right atrial (RA) flutter (cycle length = 255+/-31 msec), radiofrequency (RF) energy was delivered at electrograms in the isthmus coinciding with the center of the ECG plateau until termination of flutter, followed by local assessment of isthmus conduction during slow rate low-lateral RA pacing. 'Gaps' in the ablation line were located in the form of single or fractionated potentials centered on the isoelectric intervals of adjacent double potentials and ablated. Complete linear isthmus block was defined by the achievement of a complete corridor of parallel double potentials from the right ventricle to the inferior vena cava edge. Applications of 11+/-7 RF applications were required in all patients to achieve a complete line of double potentials separated by an isoelectric interval of 120+/-26 msec (range 60 to 190). After 6+/-3 RF applications, 6 (15%) patients had evidence of isthmus block using indirect RA activation sequence mapping without a complete line of double potentials. 5+/-5 further RF applications of eliminated local conduction and achieved complete linear block without altering descending septal RA activation. Conduction recovery occurred in 20 (50%) patients--1.85 times per patient-indicated by reversed changes in local electrograms eliminated by further ablation of the recovered gaps. After discharge, two recurrences (5%) occurred during a follow-up of 16+/-2 months. CONCLUSION: Double potential mapping is an effective assessment modality for local isthmus conduction. Slow conduction limited to the ablation line is observed during ablation in 15% of patients.

Adult↗

Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.

BACKGROUND: Atrial fibrillation, the most common sustained cardiac arrhythmia and a major cause of stroke, results from simultaneous reentrant wavelets. Its spontaneous initiation has not been studied. METHODS: We studied 45 patients with frequent episodes of atrial fibrillation (mean [+/-SD] duration, 344+/-326 minutes per 24 hours) refractory to drug therapy. The spontaneous initiation of atrial fibrillation was mapped with the use of multielectrode catheters designed to record the earliest electrical activity preceding the onset of atrial fibrillation and associated atrial ectopic beats. The accuracy of the mapping was confirmed by the abrupt disappearance of triggering atrial ectopic beats after ablation with local radio-frequency energy. RESULTS: A single point of origin of atrial ectopic beats was identified in 29 patients, two points of origin were identified in 9 patients, and three or four points of origin were identified in 7 patients, for a total of 69 ectopic foci. Three foci were in the right atrium, 1 in the posterior left atrium, and 65 (94 percent) in the pulmonary veins (31 in the left superior, 17 in the right superior, 11 in the left inferior, and 6 in the right inferior pulmonary vein). The earliest activation was found to have occurred 2 to 4 cm inside the veins, marked by a local depolarization preceding the atrial ectopic beats on the surface electrocardiogram by 106+/-24 msec. Atrial fibrillation was initiated by a sudden burst of rapid depolarizations (340 per minute). A local depolarization could also be recognized during sinus rhythm and abolished by radiofrequency ablation. During a follow-up period of 8+/-6 months after ablation, 28 patients (62 percent) had no recurrence of atrial fibrillation. CONCLUSIONS: The pulmonary veins are an important source of ectopic beats, initiating frequent paroxysms of atrial fibrillation. These foci respond to treatment with radio-frequency ablation.

Adolescent↗

Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.

BACKGROUND: Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS: Of 170 patients referred for ablation of common atrial flutter, conventional ablation of the cavotricuspid isthmus with >21 applications failed to create a bidirectional block in 13 (7.6%). An irrigated-tip catheter ablation was performed on identified gaps in the ablation line according to a protocol found to be safe in animals: a moderate flow rate of 17 mL/min and temperature-controlled (target, 50 degrees C) RF delivery with a power limit of 50 W. Bidirectional isthmus block was achieved in 12 patients by use of a mean delivered power of 40+/-6 W with a single application in 6 patients and 2 to 6 applications in the other 6. No side effects occurred during or after the procedure. CONCLUSIONS: Irrigated-tip catheter ablation is safe and effective for achieving cavotricuspid isthmus block when conventional RF energy has failed.

Adult↗

Endocardial biventricular pacing.

Simultaneous right and left ventricular pacing was performed in a 73-year-old man with coronary artery disease end-stage congestive heart failure and a DDD pacemaker implanted for sick sinus syndrome. An endocardial LV lead was introduced transseptally after unsuccessful attempts to enter the coronary sinus. This new approach for multisite pacing offers an alternative to epicardial LV from the coronary sinus or by thoracotomy.

Aged↗

Long-term follow-up after right atrial radiofrequency catheter treatment of paroxysmal atrial fibrillation.

UNLABELLED: Catheter ablation of paroxysmal atrial fibrillation using long linear lesions in the right atrium is still under investigation, and its long-term follow-up is unknown. METHODS: Thirty-six men and nine women (aged 51 +/- 12 years) with symptomatic daily episodes of AF for 6 +/- 5 years despite the use of 4.7 +/- 1.5 antiarrhythmic drugs were studied between July 1994 and January 1996. Progressively longer ablation lines were performed in 3 groups of 15 consecutive patients each, using a 14-electrode catheter or a single-electrode dragging technique. Success was defined as atrial fibrillation elimination or recurrence for no longer than 6 hours over 3 months of observation. Patients who had fewer than 6 hours of atrial fibrillation per month were considered "improved." Medium- (11 +/- 4 months) and long-term (26 +/- 5 months) results were assessed clinically from a patient's diary and from Holter recordings. RESULTS: After a follow-up of 11 months, 24 patients had a favorable result of the ablation procedure with or without additional antiarrhythmic drug therapy, representing 53% of the original cohort. After 26 +/- 5 months of follow-up, these successful results were reduced to 17 patients (37%). CONCLUSIONS: After linear atrial ablation, a significant long-term attrition of arrhythmia-free patients was observed. This may be due to a combination of disease progression, incomplete linear block, and ineffective ablation of arrhythmogenic triggers.

Atrial Fibrillation↗

Segment by segment linear ablation with an articulated bilimb catheter: initial experimental results.

Transcatheter radiofrequency (RF) ablation of atrial fibrillation or flutter requires the creation of linear lesions. However, conventional catheters are not predictably effective because of poor endocardial contact, and limited lesion size and penetration. The purpose of the study was to assess in the right atrium, the efficacy and safety of a new catheter designed to create long myocardial tissue lesions using RF energy. The main characteristics of this 8 Fr deflectable RF ablation catheter were: (1) a perpendicularly contacting articulated bilimb electrodes ensuring stable and firm endocardial firm contact; and (2) an irrigated planar interface. Three different electrode prototypes were tested. Fourteen anesthetized sheep weighing 61 +/- 7 kg underwent RF ablation in the right atrium using three incremental power levels (25 to 45, 50, 55 to 75 W) with the aim of creating fully transmural (FT) lesions, defined as continuous and complete epicardial and endocardial lesion imprints. The animals were euthanized 1 hour later for macroscopic and histologic examinations. Forty-three of the 80 right atrial lesions created, in smooth as well as in trabeculated areas, were FT. The percentage of FT lesions increased with the applied power from 37% with 25-45 W, to 49% with 50 W, and up to 86% for 55-75 W. In all but two cases, histologic examination showed no discontinuity between FT lesions produced by both limbs resulting in 19 coalescent linear lesions with an average size of 25 x 6 x 4 mm (length x width x depth). In situ bipolar electrograms after ablation in the FT group showed split potentials and/or a marked decrease in amplitude from 2.85 +/- 1.79 to 0.33 +/- 0.14 mV (P = 0.001) accompanied by near complete disappearance of unipolar electrograms. There was no perforation due to RF ablation. In conclusion, continuous and FT lesions can be achieved in various areas of sheep atria, including the trabecular right atrium, with a perpendicularly contacting bilimb electrode catheter. It represents a promising tool for catheter ablation of atrial fibrillation and flutter.

Animals↗

Specific electrocardiographic features of manifest coronary vein posteroseptal accessory pathways.

INTRODUCTION: Some posteroseptal accessory pathways (APs) can be successfully ablated by radiofrequency current only from inside the coronary sinus (CS) or its branches, because of an absolute or relatively epicardial location. The aim of this study was to identify ECG features of manifest posteroseptal APs requiring ablation in the CS or the middle cardiac veins (MCVs). METHODS AND RESULTS: One hundred seventeen consecutive patients with manifest posteroseptal APs successfully ablated: (1) > or = 1 cm deep inside the MCV (group MCV: n = 13); (2) inside the CS, including the area adjacent to the MCV ostium (group CS: n = 10); (3) at the right (group R: n = 60); or (4) the left posteroseptal endocardial region (group L: n = 34) were included. We reviewed delta wave polarity (initial 40 msec) and QRS morphology during sinus rhythm and atrial pacing as well as electrogram characteristics in these patients. The local target site electrogram in groups MCV and CS was characterized by a longer atrial to ventricular electrogram interval, suggesting a longer course of the pathway and more frequent recording of a presumptive AP potential compared to the group ablated at the right or left endocardium. The most sensitive ECG feature for group CS or group MCV was a negative delta wave in lead II in sinus rhythm (87%), but specificity (79%) and positive predictive value (50%) were relatively low. A steep positive delta wave in aVR during maximal preexcitation possessed the highest specificity and positive predictive value (98% and 88%, sensitivity 61%) which increased to 99% and 91%, respectively, when combined with a deep S wave in V6 (R wave < or = S wave). CONCLUSION: These data suggest that posteroseptal APs ablated inside the coronary venous system have highly specific features, including the combination of a steep positive delta wave in lead aVR and a deep S wave in lead V6 (R wave < or = S wave) during maximal preexcitation. The highest sensitivity is provided by a negative delta wave in lead II. These findings may be helpful for anticipating and planning an epicardial ablation strategy.

Adolescent↗

Three-dimensional mapping of the common atrial flutter circuit in the right atrium.

BACKGROUND: The full circuit of common atrial flutter using conventional methods of sequential or multielectrode activation mapping is not completely understood. METHODS AND RESULTS: We performed three-dimensional right atrial endocardial activation mapping during common counterclockwise atrial flutter in 17 patients (16 men, 1 woman; mean age, 53+/-11 years) by using the Cordis-Biosense EP Navigation system and assessed the distribution of estimated conduction velocities and double and fractionated potentials. ECG flutter wave morphologies were compared with activation patterns. Points (91+/-29) were sequentially acquired covering 88+/-11% of the flutter cycle length of 239+/-22 ms. A wide and variable posterior zone of double and fractionated potentials coincided with blocking and colliding wave fronts and formed the posterior limit of the circuit. A progressively widening septal (sep) wave front ascending from just beyond the coronary sinus ostium, passed cranially as a broad front anterior to the superior vena cava (SVC) in 14 patients, whereas fusion around the SVC formed the superior (sup) limb of the circuit in 3. Bounded anteriorly by the tricuspid valve, the wave front descended down the lateral (lat) aspect of the right atrium before completing the circuit in all cases through the inferior vena cava-tricuspid annulus isthmus. The estimated conduction velocity in the medial isthmus (0.6+/-0.3 m/s) was lower than in the other limbs of the circuit (sup=1+/-0.5 m/s, lat=1+/-0.5 m/s, sep=0.9+/-0.4 m/s, P=.05). Double and fractionated potentials were constant and more prevalent in the posterior right atrium. ECG flutter wave morphology did not correlate with three-dimensional activation maps. CONCLUSIONS: Interindividual variations occur in the right atrial circuit of common atrial flutter, with constant activation through the cavotricuspid isthmus. A variable zone of block forms the posterior limit. Fusion around the SVC can occur, and ascending medial septal activation does not follow a consistent pattern.

Adult↗

Simplified electrophysiologically directed catheter ablation of recurrent common atrial flutter.

BACKGROUND: Despite verification of bidirectional conduction block after radiofrequency (RF) catheter ablation in the inferior vena cava (IVC)-tricuspid annulus (TA) isthmus, recurrence of common atrial flutter is relatively common. Although complete linear reablation is usually performed, we evaluated a simplified electrophysiological strategy selectively targeting recovered conducting isthmus tissue. METHODS AND RESULTS: Twenty-one patients (18 men and 3 women, age, 54+/-10 years) with a recurrence of typical atrial flutter 6+/-7 months after an apparently successful catheter ablation in the IVC-TA isthmus prospectively underwent electrophysiologically targeted reablation during flutter. Sites with narrow electrograms or fractionated electrograms interposed between adjacent sites with double potentials considered to represent gaps were ablated without movement of the catheter. Mapping showed that 18 of 21 patients had a single gap. Successful ablation required a single application in 14 patients and, in the group as a whole, a median of one application (mean, 2+/-2; range, 1 to 11) with resultant bidirectional block in 13 of 16. A single narrow electrogram (duration, 48+/-6 ms; amplitude, 0.1+/-0.05 mV) was noted at the successful site in 11, whereas a fractionated electrogram (97+/-32 ms, 0.05+/-0.04 mV, P<.05) was noted in 9. There were four additional recurrences during a follow-up at 7+/-5 months; three were similarly ablated with a median of one pulse. CONCLUSIONS: Transmural ablation lesions in the isthmus can be recognized during flutter by double potentials separated by an isoelectric interval. Postablation recurrent flutter is usually due to a single discrete recovered gap; this is represented by a single or a fractionated potential spanning the isoelectric interval of adjacent double potentials, which can be selectively targeted to minimize repeat ablation.

Adult↗

A focal source of atrial fibrillation treated by discrete radiofrequency ablation.

BACKGROUND: Atrial fibrillation is usually thought to be due to multiple circulating reentrant wavelets. From previous studies, a focal mechanism is considered to be very unlikely. In this report, focal atrial fibrillation is defined on an ECG pattern of atrial fibrillation and later demonstrated to be due to a focal source. METHODS AND RESULTS: Nine patients (five men and four women, age, 38 +/- 7 years) with paroxysmal focal atrial fibrillation are reported here. All were free of structural heart disease and had frequent episodes of atrial fibrillation despite the use of a mean of 4 +/- 2 antiarrhythmic drugs. Atrial fibrillation was associated with runs of irregular atrial tachycardia or monomorphic extrasystoles. The electrophysiological study demonstrated that all the atrial arrhythmias were due to the same focus firing irregularly and exhibiting a consistent and centrifugal pattern of activation. Three foci were found to be located in the right atrium, two near the sinus node and one in the ostium of the coronary sinus. Six others were located in the left atrium at the ostium of the right pulmonary veins (n = 5) and at the ostium of the left superior pulmonary vein (n = 1). All atrial arrhythmias were successfully treated by use of a mean of 4 +/- 4 radiofrequency pulses. CONCLUSIONS: In some patients, the surface ECG pattern of atrial fibrillation is due to a focal rapidly firing source of activity that can be eliminated by discrete radiofrequency energy applications.

Adult↗

Role of catheter ablation for atrial fibrillation.

Atrial fibrillation, the most common of all sustained cardiac arrhythmias, can be cured using extensive surgical atriotomies. Experimental studies using linear radiofrequency catheter ablation lesions suggest the relative safety and high efficacy of these procedures. However animal models may not be relevant to human pathology because of the small size of atria, different pathophysiologic substrates, and the lack of data pertaining to spontaneous initiation of atrial fibrillation. Preliminary human studies show a higher success rate when linear ablations are performed in the left atrium than in the right atrium and that arrhythmogenic foci play a significant role in atrial fibrillation. However the procedures are prolonged, and it is difficult with current technology to achieve a linear conduction block consistently. The challenge remains to optimize this as yet investigational technique and transform it into a routine procedure.

Atrial Fibrillation↗

Analysis of electrophysiological activity in Koch's triangle relevant to ablation of the slow AV nodal pathway.

Atrioventricular junctional reentrant tachycardia (AVJRT) is the most common form of paroxysmal regular supraventricular tachycardia. In patients with disabling, drug refractory AVJRT, catheter ablation has evolved rapidly from a last-resort treatment in the form of interruption of atrioventricular (AV) conduction to selective modification of AV nodal function as an ideal treatment. This article will focus on the frequently unappreciated electrophysiological activities recordable in man in Koch's triangle during ablation of the so-called slow pathway.

Atrioventricular Node↗

Regional disparities of endocardial atrial activation in paroxysmal atrial fibrillation.

UNLABELLED: Previous experimental data suggest that atrial activity is homogeneously distributed during paroxysmal atrial fibrillation (AFib). Little is known about this in human paroxysmal AFib. METHODS: Twenty-five men and two women (mean age 49 +/- 11 years; five with structural heart disease) with paroxysmal AFib for a mean 5 +/- 6.2 years despite the use of a mean of 3.6 +/- 1.7 antiarrhythmic drugs underwent atrial mapping. The right atrium was divided into four regions: posterior (intercaval), lateral, anterior, and septal. A 14-pole catheter was positioned to assess complex electrical activity defined as the duration of continuous electrical activity or electrograms with FF intervals < 100 ms for 60 seconds (expressed as percentage of time). In addition, the left atrium (divided into three regions: posterior, anterior, and septal) was explored in 12 patients with a multipolar catheter. RESULTS: The complex electrical activity time between all the regions explored was significantly different. In the right atrium, the septal (74% +/- 32%; P = 0.02) and the posterior (63% +/- 32%; P = 0.04) areas were significantly more disorganized than the lateral (22% +/-23%) and anterior (21% +/- 26%) regions. In the left atrium, complex electrical activity was predominant and widely distributed (posterior: 87% +/- 11%; septal: 65% +/- 27%) except in the appendage area (anterior region: 18% +/- 14%). CONCLUSIONS: Quantitative assessment of complex electrical activity in both atria in humans shows heterogeneous temporal and spatial distribution. This may have implications for guiding catheter ablation of AFib.

Anti-Arrhythmia Agents↗