Radioactive lung scanning in the diagnosis and management of pulmonary disorders.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D C Sabiston.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Right ventricular assist devices are becoming increasingly used as both a bridge to heart transplantation and as a means of temporary support after cardiopulmonary bypass. There has also been a resurgence of interest in pulsatile devices fueled by anecdotal, clinical reports. However, a load-independent analysis of biventricular function after right ventricular assistance comparing a pulsatile versus a continuous-flow right ventricular assist device has not been performed, and we hypothesize that a pulsatile device is less detrimental to cardiac function than a conventional, nonpulsatile pump. METHODS: Sixteen dogs (20 to 25 kg) were instrumented through a median sternotomy for placement of left ventricular and right ventricular epicardial dimension transducers in the major, minor, and septal-free wall axes. Intracavitary micromanometers were placed in both ventricles as well. Baseline pressure-dimension data were collected, and the right atrium and pulmonary artery were cannulated. Right ventricular bypass with the use of a pneumatically driven pulsatile right ventricular assist device (SV = 60 ml; n = 7) or a conventional continuous-flow centrifugal right ventricular assist device (n = 9) was instituted for a 4-hour duration. Animals were then weaned from right ventricular support and decannulated. After bypass, biventricular function data were then collected. The load-insensitive stroke work-end diastolic volume relationship known as preload recruitable stroke work was derived and expressed as a fraction of baseline function along with conventional hemodynamic indexes, cardiac output, and pulmonary vascular resistance. RESULTS: Results of this analysis show no significant benefit to either right ventricular or left ventricular function (right ventricular preload recruitable stroke work index: 0.863 +/- 0.3 [pulsatile] versus 0.849 +/- 0.2 [continuous], left ventricular preload recruitable stroke work index: 0.880 +/- 0.4 [pulsatile] versus 0.821 +/- 0.3 [continuous] after pulsatile right ventricular support. Likewise, cardiac output (1.4 +/- 0.1 [pulsatile] versus 1.5 +/- 0.2 [continuous] L/min) and pulmonary vascular resistance (4.8 +/- 1.0 [pulsatile] versus 3.2 +/- 1.1 [continuous] Wood Units) were not significantly different in either study group. CONCLUSIONS: We conclude from these data that pneumatically driven pulsatile right ventricular assist devices provide no additional benefit to myocardial performance beyond that of conventional, nonpulsatile pumps. Further studies investigating a speculative benefit from pulsatile circulatory support are necessary to further define a potential role for these novel devices.
Previous studies have documented decreases in serum-free triiodothyronine (T3) after brain death and improved hemodynamics with its replacement, suggesting its controversial, but promising, clinical utility for managing potential organ donors. Vasopressin is also commonly used clinically as a pressor agent after brain death. A load-independent analysis of cardiac function and an assessment of myocardial blood flow (MBF) with these agents have not been reported, however. Eighteen pigs were instrumented with left ventricular epicardial dimension transducers and a left ventricular micromanometer. MBF was assessed by standard microsphere techniques. Baseline left ventricular pressure-dimension data were collected, and brain death was induced by ligating the innominate and left subclavian arteries. Left ventricular function data were collected every 30 minutes after brain death to 6 hours or until the animal died. Microsphere injections were performed before brain death and hourly thereafter to 4 hours. At 90 minutes after brain death, animals were assigned to a vasopressin (2 units/hr, intravenously, n = 6), T3 (0.05 microgram/kg/hr, intravenously, n = 6), or control (n = 6) treatment group. Preload recruitable stroke work (PRSW), a load-independent index of left ventricular function, was derived from the pressure-dimension data. MBF was calculated by conventional methods. At 4 hours after brain death, PRSW and MBF decreased significantly in the control, vasopressin, and T3 groups relative to the baseline, pre-brain dead state (PRSW: -36% +/- 12%, -48 +/- 7%, -52% +/- 5%; MBF: -27% +/- 15%, -38% +/- 5%, -78% +/- 2%, respectively). Neither vasopressin nor T3, however, showed any advantage over the control group in terms of preserving left ventricular function or prolonging survival. Furthermore, these data show a marked decrease in MBF in the T3 group (p < 0.01 versus control and vasopressin groups) without a significant change in cardiac function. Analysis of endocardial to epicardial flow ratios disclosed no significant differences between groups at any time. In summary, animals treated with T3 had a greater decline in MBF than the control group at 4 hours, without any benefit to cardiac function. Further studies examining the mechanism responsible for the deterioration of MBF and cardiac dysfunction will be necessary to optimally manage the brain dead patient before organ harvest, especially regarding the precise role of T3.
Explore the source record for details and available documents.